• Title/Summary/Keyword: Lateral arm

Search Result 154, Processing Time 0.021 seconds

Study on the Usefulness about Molecular Breast Imaging In Dense Breast (치밀형 유방에서 Molecular Breast Imaging 검사의 유용성에 관한 고찰)

  • Baek, Song Ee;Kang, Chun Goo;Lee, Han Wool;Park, Min Soo;Choi, Young Sook;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.42-46
    • /
    • 2016
  • Purpose Mammography is the most widely used scan for the early diagnosis since it is possible to observe the anatomy of the breast. however, The sensitivity is markedly reduced in high-risk patients with dense breast. Molecular Breast Imaging (MBI) sacn is possible to get the high resolution functional imaging, and This new neclear medicine technique get the more improved diagnostic information through It is useful for confirmation of tumor's location in dense breast. The purpose of this study is to evaluate the usefulness of MBI for tumor diagnosis in patients with dense breast. Materials and Methods We investigated 10 patients female breast cancer with dense breast type who had visited the hospital from September 1st to Octorber 10th, 2015. The patients underwent both MBI and Mammography. MBI (Discovery 750B; General Electric Healthcare, USA) scan was 99mTc-MIBI injected with 20 mCi on the opposite side of the arm with the lesions, after 20 minutes, gained bilateral breast CC (CranioCaudal), MLO (Medio Lateral Oblique) View. Mammography was also conducted in the same posture. MBI and Mammography images were compared to evaluate the sensitivity and specificity of each case utilizing both image and two images in blind tests. Results The results of the blind test for breast cancer showed that the sensitivity of Mammography, MBI scan was 63%, 89%, respectively, and that their specificity was 38%, 87%, respectively. Using both the Mammography and MBI scan was Sensitivity 92%, specificity 90%. Conclusion This research has found that, The tumor of dense tissue that can not easily distinguishable in Mammography is possible to more accurate diagnosis since It is easy to visually evaluation. But MBI sacn has difficulty imaging microcalcificatons, If used in conjunction with mammography it is thought to give provide more diagnostic information.

  • PDF

Breast Conserving Operation and Radiation Therapy in Early Breast Cancer : Interim Analysis (초기유방암에서 유방보존수술 후 방사선치료 : 중간분석)

  • Kim, Jin-Hee;Kim, Ok-Bae;Kim, You-Sah
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2001
  • Purpose : To evaluate interim results in terms of failure, cosmetic results and survival after breast conserving operation and radiation therapy in early breast cancer. Material and Methods : From January 1992 through December 1997, seventy two patients with early stage 0, I and II breast cancer were treated with conservative surgery plus radiotherapy at Keimyung University Dongsan Medical Center. Age distribution was 25 to 77 years old with median age of 43. According to TNM stage, five patients had stage 0, thirty three were stage I, twenty five were IIa, and nine were IIb. Most patients underwent excision of all gross tumor and ipsilateral axillary dissection. Breast was irradiated through medial and lateral tangential fields of 6 MV photons to 50.4 Gy in 28 fractions over 5.5 weeks. We delivered a boost irradiation dose of 10 to 16 Gy in 1 to 2 weeks to excision site. Adjuvant chemotherapy was administered in forty one patients with CMF (cyclophosphamide, methotrexate, 5-fluorouracil) regimens of 6 cycles concurrently or before radiation. Cosmetic results were assessed by questionnaire to patients grading of excellent, good, fair, poor. Follow-up periods were 22 to 91 months with median 40 months. Results : Five year disease free survival rate (5YDFS) was $95.8\%$. According to stage, 5YDFS was $100\%,\;96.9\%,\;96\%\;and\;88.9\%$ in stage 0, I, IIa and IIb, respectively. Two patients had distant metastasis and one had local and distant failure. One patient with distant failure had bone and liver metastasis at 14 months after treatment and the other had lung and both supraclavicular metastasis at 21 months after treatment. Patient with local and distant failure had local recurrence on other quadrant in same breast and then salvaged with total mastectomy and chemotherapy but she died due to brain metastasis at 55 months. Complications were radiation pneumonitis in five patients (four patients of asymptomatic, one patients of symptomatic) and hand or arm edema(4 patients). Fifty nine patients answered our cosmetic result questionnaire and cosmetic results were good to excellent in fifty one patients $(86\%)$. Conclusion : We considered that conservative surgery and radiation for the treatment of early stage invasive breast cancer was safe and had excellent survival and cosmetic results. We need to assess about prognostic factors with longer follow up and with large number of patients.

  • PDF

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • Hong, Dong-Ki;Lee, Woo-Seok;Kwon, Kyung-Tae;Park, Kwang-Ho;Kim, Chung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.43-61
    • /
    • 2004
  • Purpose : For qualify improvement in radiotherapy, it is important to set up and evaluate equipment (linac) accurately. In addition, technicians are needed to be fully aware of the equipment's detailed quality and its manual. Therefore, the result of ATP is evaluated and introduced, in order that the technicians are skilled by participating in quality assurance (QA) and understanding the quality of the equipment before clinical use. Method and Material : QA for LINAC 21EX (Varian, US) was done with suppliers its procedure was divided into radiation survey, mechanical test, radiation isocenter test, bean performance, dosimetry, and enhanced dynamic wedge and using X-omat film (Kodak), multidata, densitometer, and electrometer. QA of MLC (Millennium, 120 leaf) attached to LINAC and EPID (Portal vision) were done separately. Result : The leakage dose by survey meter was below the tolerance. In mechanical test, collimater, gantry, and couch rotation were less than 1mm, and the angles were ${\pm}0.1^{\circ}$ for digital and ${\pm}0.5^{\circ}$ for mechanical. The alignment test of the light field and crosshair were evaluated less than 1mm. The (a)symmetrical jaw field was less than ${\pm}0.5mm$. The radiation isocenter test using X-mat film was less than 1mm. The consistency of light field and radiation field was less than ${\pm}0.1mm$. PDD for photon energy was less than ${\pm}1\%$ and for electron energy of $90\%,\;80\%,\;50\%,\;and\;30\%$ were evaluated within the tolerance. Flatness for photon and electron energy was evaluated $2.3\%$ (tolerance $3\%$) and $3\%$ (tolerance $4.5\%$), respectively, and symmetry was $0.45\%$ (tolerance $2\%$) and $0.3\%$ (tolerance $2\%$), respectively. Dosimetry test for short term, MU setting, rep rate, and dose rate accuracy of photon and electron energy was within the tolerance depending on energy, MU, and gantry angle. Conclusion : Accuracy and safety for clinical use of Clinac 21EX was verified through customer acceptance procedure and the quality of the equipment was found out. These can reduce the difficulties in using the equipment. Furthermore, it is useful for clinically treatment of patients by technicians' active participations.

  • PDF