• 제목/요약/키워드: Lateral anchor

검색결과 71건 처리시간 0.02초

Delayed Lateral Row Anchor Failure in Suture Bridge Rotator Cuff Repair: A Report of 3 Cases

  • Jeong, Jae-Jung;Ji, Jong-Hun;Park, Seok-Jae
    • Clinics in Shoulder and Elbow
    • /
    • 제21권4호
    • /
    • pp.246-251
    • /
    • 2018
  • Compared to single row repair, use of lateral row anchors in suture bridge rotator cuff repair enhances repair strength and increases footprint contact area. If a lateral knotless anchor (push-in design) is inserted into osteoporotic bone, pull-out of the lateral row anchor can developed. However, failures of lateral row anchors have been reported at several months after surgery. In our cases, even though complete cuff healing occurred, delayed pull-out of the lateral row anchor in the suture bridge repair occurred. In comparison to a conventional medial anchor, further biomechanical evaluation of the pull-out force, design, and insertion angle of the lateral anchor is needed in future studies. We report three cases with delayed pull-out of lateral row anchor in suture bridge rotator cuff repair with a literature review.

Magnetic resonance imaging analysis of screw in-type lateral anchor pull-out in large to massive rotator cuff repair in patients older than 60 years

  • Lee, Sang-Yoon;Noh, Young-Min
    • Clinics in Shoulder and Elbow
    • /
    • 제25권1호
    • /
    • pp.15-21
    • /
    • 2022
  • Background: This study was performed to identify the incidence of screw in-type lateral anchor pull-out in patients older than 60 years who underwent rotator cuff repair for large to massive rotator cuff tear (RCT). Methods: We reviewed 25 patients over 60 who were diagnosed with large to massive RCT and underwent arthroscopic rotator cuff repair in our hospital from March 2017 to February 2021. Preoperative tear size (anterior to posterior, medial to lateral) was measured via preoperative magnetic resonance imaging (MRI). All 25 patients underwent MRI scanning on postoperative day 1 and at 3 months after surgery. The change of anchor position was measured in axial views on MRI images postoperative day 1 and 3 months after surgery. And it was statistically compared according to bone mineral density (BMD), sex, and number of lateral anchors. Results: Two MRIs (postoperative day 1 and 3 months) in 25 patients were compared. Anchor pull-out occurred in six patients during 3 months (6.7%), and the mean pull-out length difference was 1.56 mm (range, 0.16-2.58 mm). There was no significant difference in the number of pull-out anchors, degree of pull-out difference by comparing BMD (A, BMD≤-2.5; B, BMD>-2.5), sex, or number of anchors used in each surgery (C, two anchors; D, three anchors) (p>0.05). Conclusions: Pull-out of screw in-type anchors was rarely observed and the mean pull-out length difference was negligibly small in our study. The screw in-type lateral anchor seems to be a decent option without concern of anchor pull-out even in elderly patients.

Revision of a Pull-out Suture Anchor in the Lateral Row During the Suture-bridge Technique

  • Kim, Kyung-Cheon;Rhee, Kwang-Jin;Shin, Hyun-Dae;Byun, Ki-Yong;Yang, Jae-Hoon;Kim, Dong-Kyu;Kim, Bo-Kun
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 2009년도 제17차 학술대회
    • /
    • pp.159-159
    • /
    • 2009
  • Repeated pulling-out of a suture anchor in the lateral row despite repeated attempts at insertion during a rotator cuff repair is not uncommon with the suture-bridge technique, especially in patients with osteoporosis. We describe a simple procedure for dealing with the pull-out of a PushLock anchor in the lateral row using a suture anchor with a suture eyelet during rotator cuff repair applying the suture-bridge technique.

  • PDF

봉합 나사를 이용한 변형 Br$\ddot{o}$strom 술식 및 관절경 검사를 이용한 족관절 외측 불안정성의 치료 (Treatment of Chronic Ankle Lateral Instability using Modified Br$\ddot{o}$strom Procedure with Anchor suture & Arthroscopy)

  • 이진영;김갑래;이은수;박현진
    • 대한족부족관절학회지
    • /
    • 제13권2호
    • /
    • pp.175-178
    • /
    • 2009
  • Purpose: To evaluate the result of modified Br$\ddot{o}$strom procedure with anchor suture and explore associate lesion under arthroscopy for chronic lateral instability. Materials and Methods: From May 2005 to March 2009, Retrospective analysis of 126 patients with chronic lateral instability who underwent modified Br$\ddot{o}$strom procedure with anchor suture and arthroscopic procedure was done. Mean follow-up period was 13 months. Results: Chronic lateral instability of the ankle almost had local synovitis by arthroscopic examination. There were osteochondral lesion of talus on the anteromedial aspect in 63 cases, on the anterolateral aspect in 25 cases, osteochondral lesion of tibia side in 8 cases, fat hypertrophy of tibiofibular space in 120 cases, anterior fat impingement in 26 cases, intra-articular loose body in 13 cases. Mean Karlsson scoring scale was improve from 53 preoperatively to 91 postoperatively, There were 70 cases excellent, 27 cases good, 26 cases fair, 3 cases poor result according to the Sefton procedure. Conclusion: Modified Br$\ddot{o}$strom procedure with anchor suture and arthroscopic procedure are reliable treatment method for chronic ankle lateral instability which has intraarticular pathology.

  • PDF

Cement Augmentation for Lateral Row Fixation in Rotator Cuff Repair: A Case Report

  • Kim, Jin Hwan;Koh, Kyoung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • 제20권1호
    • /
    • pp.42-45
    • /
    • 2017
  • One of the most important factors leading to a successful healing of rotator cuff tear is good bone quality to secure the suture anchor in the bone for a stable fixation. However, rotator cuff tear are commonly found in elderly patients, and their proximal humerus often shows osteoporosis or cystic lesions. Especially when the transosseous repair prevails for a torn rotator cuff, a weak metaphyseal cancellous bone is often the case, which associated with difficulty in stable fixation of the lateral row suture anchor. In this situation, we were able to augment the lateral row fixation with polymethylmethacrylate bone cement. Although there is a concern of disturbance in the blood flow and healing potential, our case showed good clinical results with respect to healing. If we suspect a weak fixation of the lateral row suture anchor, bone cement seems to be a good option for augmentation.

철근콘크리트 교량의 충격전달장치 앵커시스템의 전단파괴거동 (Shear Fracture Behavior of Anchor Systems for Shock Transmission Unit in RC Bridge)

  • 김태상;송하원;변근주;안창모
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1097-1102
    • /
    • 2001
  • Seismic safety of continuous span concrete bridge can be enhanced by distributing a large seismic lateral load to each supporting pier. A new viscoelastic device called Shock Transmission Unit(STU), which is a simple cylinder-piston assembly packed with a so-called silicone putty compound, enables the lateral seismic load to be transmitted to the pier by installation of the device to movable bearings of the bridge. The seismic safety of concrete bridges having the STU depends on not only safety of the bridges globally but also safety of anchor systems which anchors the STU to concrete pier. An experimental investigation is performed to study the behavior of cast-in-place anchor and post-installed anchor subjected to shear load statically and cyclically according to different edge distance, embedment length, and anchor spacing. Finally, the experimental results are compared with results by design methods of ACI and CCD, and results by FEM analysis.

  • PDF

Shear behavior of exposed column base connections

  • Cui, Yao
    • Steel and Composite Structures
    • /
    • 제21권2호
    • /
    • pp.357-371
    • /
    • 2016
  • Column base connections are critical components in steel structures because they transfer axial forces, shear forces and moments to the foundation. Exposed column bases are quite commonly used in low- to medium-rise buildings. To investigate shear transfer in exposed column base plates, four large scale specimens were subjected to a combination of axial load (compression or tension) and lateral shear deformations. The main parameters examined experimentally include the number of anchor rod, arrangement of anchor rod, type of lateral loading, and axial force ratio. It is observed that the shear resisting mechanism of exposed column base changed as the axial force changed. When the axial force is in compression, the resisting mechanism is rotation type, and the shear force will be resisted by friction force between base plate and mortar layer. The specimens could sustain inelastic deformation with minimal strength deterioration up to column rotation angle of 3%. The moment resistance and energy dissipation will be increased as the number of anchor rods increased. Moreover, moment resistance could be further increased if the anchor rods were arranged in details. When the axial force is in tension, the resisting mechanism is slip type, and the shear force will be resisted by the anchor rods. And the shear resistance was reduced significantly when the axial force was changed from compression to tension. The test results indicated that the current design approach could estimate the moment resistance within reasonable acceptance, but overestimate the shear resistance of exposed column base.

발목관절 외측 불안정성에서 단일 봉합나사와 이중 봉합나사를 이용한 변형 Brostrom 술식간의 임상결과 비교 (A comparison between the modified Brostrom procedure using single and double suture anchor for chronic lateral ankle instability)

  • 손현철;조병기;김용민;김동수;최의성;박경진;박지강
    • 대한정형외과스포츠의학회지
    • /
    • 제10권2호
    • /
    • pp.69-77
    • /
    • 2011
  • 목적: 만성 발목관절 외측 불안정성 환자에 대한 변형 Brostrom 술식에서 단일 봉합나사와 이중 봉합나사를 이용한 기법간의 임상 결과를 후향적으로 비교하고자 하였다. 대상 및 방법: 본원에서 봉합나사를 이용한 변형 Brostrom 술식을 시행받은 환자들 중 최소 1년 이상 추시가 가능하였던 37례를 대상으로 하였다. 모든 수술은 동일한 술자에 의해 이루어졌으며 단일 봉합나사를 이용한 경우가 17예, 이중 봉합나사를 이용한 경우가 20예 였다. 임상적 결과의 평가는 Karlsson 점수 및 Sefton의 평가법을 이용하였고, 발목관절의 기계적인 안정성에 대한 방사선학적 평가로 Telos 기기를 이용한 전방 전위 및 내반 스트레스 검사가 이용되었다. 결과: Karlsson 점수는 단일 봉합나사군이 술 전 평균 45.2점에서 술 후 89.4점으로, 이중 봉합나사군이 술 전 평균 46.4점에서 90.5점으로 각각 호전되었다. Sefton 평가법상 단일 봉합나사군은 우수가 7예, 양호가 8예, 보통이 2예 였고, 이중 봉합나사군은 우수 8예, 양호 10예, 보통 2예로 나타나 각각 15례(88.2%), 18례(90%)에서 만족스러운 결과를 보였다. 스트레스 방사선검사 상 거골 경사각과 거골 전방전위는 단일 봉합나사군이 술 전 평균 13.6도, 8.6 mm에서 술 후 최종 추시시 5.4도, 4.1 mm로, 이중 봉합나사군이 술 전 평균 14.1도, 8.4 mm에서 술 후 3.9도, 4 mm로 각각 호전되었으며 두 기법간에 술 후 거골 경사각의 유의한 차이를 보였다(p<0.05). 결론: 만성 발목관절 외측 불안정성에 대한 변형 Brostrom 술식에서 단일 봉합나사와 이중 봉합나사를 이용한 기법간에 술 후 임상 결과의 유의한 차이는 없었으나, 발목관절의 기계적인 안정성은 이중 봉합나사군에서 더 우수하였다. 단일 봉합나사와 이중 봉합나사를 이용한 변형 Brostrom 술식 모두 효과적인 치료 방법이라고 생각되며, 향후 운동 선수들을 대상으로 한 치료결과 및 생역학적 분석이 필요할 것으로 생각한다.

  • PDF

외측 족관절 불안정성 환자에서 봉합 나사와 PushLock Anchor를 이용한 변형 Brostrom 술식 (Modified Brostrom Procedure with Suture Anchor & PushLock Anchor in Lateral Ankle Instability)

  • 신성일;김갑래;조주성;이효범;권재우
    • 대한족부족관절학회지
    • /
    • 제16권4호
    • /
    • pp.241-246
    • /
    • 2012
  • Purpose: The purpose of our study was to perform a comparison of the outcomes of the modified Brostrom procedure using only a suture anchor compared with using a suture anchor with a pushlock anchor. Materials and Methods: This was a retrospective study of chronic lateral ankle instability that underwent a modified Brostrom procedure using a bioabsorbable suture anchor & a pushlock anchor, performed by a single surgeon. A total of 88 patients were enrolled in the study. The function of the patient's ankles were scored using the American Orthopaedic Foot and Ankle Society (AOFAS), visual analogue scale (VAS) both preoperatively and postoperatively. Results: The difference in the overall means between the group A and group B was not statistically significant. But, the patient's satisfaction was better in the group B, and there were more complications in the group A. Conclusion: The technique presented here uses the modified Brostrom procedure with pushlock anchors to prevent the problems associated with subcutaneous knot irritation.

Suture anchor를 이용한 외측 반월판 연골 전방 뿌리 파열의 관절경적 치료 -증례 및 술기 보고- (Arthroscopic Repair of Anterior Root Injury in Lateral Meniscus Using Suture Anchor - Case Report and Technical Note -)

  • 김도영;유연식;이상수;정운섭;서은민;박승재
    • 대한정형외과스포츠의학회지
    • /
    • 제10권1호
    • /
    • pp.41-45
    • /
    • 2011
  • 반월상 연골판의 뿌리파열의 심각성이 인식되면서 이에 대한 적극적인 봉합이 필요하게 되었다. 특히 후각부 뿌리 파열에 대한 봉합 방법과 결과가 최근에 많이 보고되고 있다. 그러나 전각부 뿌리 파열에 대한보고는 아직 보고된 바 없으며 이에 저자들은 과거에 시행했던 원판형 연골의 부분 절제 후 발생한 의인성 뿌리 파열과 이로 인한 아탈구를 경험하였고 이를 봉합나사를 이용하여 정복하여 좋은 결과를 얻었기에 보고하는 바이다.

  • PDF