• Title/Summary/Keyword: Lateral Load System

Search Result 400, Processing Time 0.031 seconds

A Study on the Structural Behaviour of Staggered Truss System by the Shape of Truss (트러스 형태에 따른 스태거드트러스 골조시스템의 구조특성에 관한 연구)

  • Rha, Chang-Soon;Hong, Yoon-Soo;Yu, Eun-Jong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.3
    • /
    • pp.199-206
    • /
    • 2017
  • This paper analyzed structural behaviors of the staggered truss system, typically used in low seismicity regions, resisting the lateral loads such as wind and seismic load. A comparative study of cost and efficiency was carried out by analysing and designing the 10- and 20-story buildings with various types of truss, including pratt, howe, warren, K-, and vierendeel, which may typically be used in staggered truss system. In design, column and truss members are selected in group, and the efficiency of the member design was judged by average demand capacity ratio of the all members in same group. And economic analysis of the system was investigated by the quantity of the structural members. As a result, staggered truss system with the pratt truss and warren truss showed the most economical and efficient performance for 10-story building, and 20-story building, respectively.

Structural Design of Coupled RC Structural Wall Considering Plastic Behavior (소성거동을 고려한 병렬 RC 구조벽체시스템의 설계)

  • Yu, Seung-Yoon;Eom, Tae-Sung;Kang, Su-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.4
    • /
    • pp.351-361
    • /
    • 2017
  • Reinforced concrete(RC) structural walls are major lateral load-resisting structural member in building structures. Generally these RC structural walls are coupled with each other by the coupling beams and slabs, and therefore they behave as RC coupled structural wall system. In the design of these coupled structural wall systems, member forces are calculated using elastic structural analysis. These elastic analysis methodologies for the design of coupled structural wall system was not reasonable because it can not consider their ultimate behavior and assure economic feasibility. Performance based design and moment redistribution method to solve these problems is regarded as a reasonable alternative design method for RC coupled structural wall system. However, it is not verified under various design parameters. In this study, nonlinear analysis of RC coupled structural wall system was performed according to various design parameters such as reinforcement ratio, ultimate concrete strain and wall height. Based on analysis results, design considerations for coupled RC structural wall system was proposed.

Structural Design And Analysis of Haeundae Doosan We've The Zenith (해운대 두산 위브 더 제니스 구조설계)

  • Park, Ki-Hong;Park, Suk-Jin
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.93-98
    • /
    • 2008
  • Haeundae Doosan We've The Zenith project is adjacent to Suyoung-bay, now it is in the process of excavation and foundation work. The main use of the tower is residence which height is 300m and 80 floor, the highest residential reinforced concrete building through the Orient. It is comprised of 3 high- rised buildings and 1 low-rised building, the basement is 230m wide and 200m length sized mass structure. The lateral resistance system is acted effectively against the lateral load and satisfactorily against the wind vibration by the 4 direction extension of the center core wall($700{\sim}800mm$ thickness) and reinforced concrete column set around the slab. Flat-plate slab system(250mm thickness) is adjusted for the slab system and it enables effective work process and shortening the working term by minimizing the ceiling height and not needing to install perimeter beam and drop panel. The strength and serviceability of the structure is able to be monitored and estimated constantly through the health monitoring system during the construction and after the construction.

  • PDF

Seismic Capacity Evaluation of Existing Medium-and low-rise R/C Frame Retrofitted by H-section Steel Frame with Elastic Pad Based on Pseudo-dynamic testing (유사동적실험에 의한 탄성패드 접합 H형 철골프레임공법으로 보강 된 기존 중·저층 R/C 골조의 내진성능 평가)

  • Kim, Jin-Seon;Lee, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.83-91
    • /
    • 2021
  • In this study, to improve the connection performance between the existing reinforced concrete (R/C) frame and the strengthening member, we proposed a new H-section steel frame with elastic pad (HSFEP) system for seismic rehabilitation of existing medium-to-low-rise reinforced concrete (R/C) buildings. This HSFEP strengthening system exhibits an excellent connection performance because an elastic pad is installed between the existing structure and reinforcing frame. The method shows a strength design approach implemented via retrofitting, to easily increase the ultimate lateral load capacity of R/C buildings lacking seismic data, which exhibit shear failure mechanism. Two full-size two-story R/C frame specimens were designed based on an existing R/C building in Korea lacking seismic data, and then strengthened using the HSFEP system; thus, one control specimen and one specimen strengthened with the HSFEP system were used. Pseudodynamic tests were conducted to verify the effects of seismic retrofitting, and the earthquake response behavior with use of the proposed method, in terms of the maximum response strength, response displacement, and degree of earthquake damage compared with the control R/C frame. Test results revealed that the proposed HSFEP strengthening method, internally applied to the R/C frame, effectively increased the lateral ultimate strength, resulting in reduced response displacement of R/C structures under large scale earthquake conditions.

Vibration Reduction Effect and Structural Behavior Analysis for Column Member Reinforced with Vibration Non-transmissible Material (진동절연재로 보강된 기둥부재의 진동저감효과 및 구조적 거동분석)

  • Kim, Jin-Ho;Yi, Na-Hyun;Hur, Jin-Ho;Kim, Hee-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.94-103
    • /
    • 2016
  • For elevated railway station on which track is connected with superstructure of station, structural vibration level and structure-borne-noise level has exceeded the reference level due to structural characteristics which transmits vibration directly. Therefore, existing elevated railway station is in need of economical and effective vibration reduction method which enable train service without interruption. In this study, structural vibration non-transmissible system which is applied to vibroisolating material for column member is developed to reduce vibration. That system is cut covering material of the column section using water-jet method and is installed with vibroisolating material on cut section. To verify vibration reduction effect and structural performance for structural vibration non-transmissible system, impact hammer test and cyclic lateral load test are performed for 1/4 scale test specimens. It is observed that natural period which means vibration response characteristics is shifted, and damping ratio is increased about 15~30% which means that system is effective to reduce structural vibration through vibration test. Also load-displacement relation and stiffness change rate of the columns are examined, and it is shown that ductility and energy dissipation capacity is increased. From test results, it is found that vibration non-transmissible system which is applied to column member enable to maintains structural function.

Numerical Study on Interior Flat Plate-Column Connections Subjected to Unbalanced Moment (불균등 휨모멘트를 받는 플랫 플레이트-기둥 접합부에 대한 해석연구)

  • 최경규;황영현;박홍근
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.949-960
    • /
    • 2002
  • Flat plate structures under lateral load are susceptible to punching shear failure of the slab-column connection. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, due to complexity in the behavior and difficulty in simulating the actual load and boundary conditions of the flat plate system, it is not easy to obtain reliable data regarding to the strength and ductility from the previous experimental studies. In the present study, a numerical study was performed for interior connections of continuous flat plate. For the purpose, a computer program for nonlinear FE analyses was developed, and the validity was verified by comparisons with the existing experimental results. Through the parametric studies, the variations of bending moment, shear, and torsional moment around the connection were investigated. Based on the findings of the numerical studies, the aspects which need to be improved in current design methods were discussed. The results of the present study will be used for developing a design method for the flat plate-column connection in the companion paper.

Analysis of CFT Column-RC Flat Plate Interior Connections under Lateral Load (횡하중을 받는 CFT기둥-RC무량판 접합부의 해석연구)

  • Song, Jin-Kyu;Song, Ho-Bum;Oh, Sang-Won;Kim, Byung-Jo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.867-870
    • /
    • 2008
  • Flat plate system has many advantages, story height reduction, a term of works shortening and changeableness of space, etc. However structures become a tendency of higher stories and when we use RC column, the size of column grow larger. For this reason the use of CFT column is increasing more and more. Accordingly, this study carried out the nonlinear finite element analysis. As a result of analysis moment strength of the connection increased but ductility decreased as the top reinforcement ratio in th effective width increased. And moment strength and ductility of the connection decreased as gravity load ratio decreased. In the case that shearhead length is not more than 0.27m, the effectiveness of shearhead length on the moment strength and ductility of the connection were small relatively to other variables. Initial stiffness and moment strength of connection increased as slab thickness increased

  • PDF

Effects of Design Conditions in Five Pad Tilting Pad Bearing on the Lateral Vibration Characteristics of Small Gas Turbine (5패드 틸팅 패드 베어링의 설계 조건 변화가 소형 가스터빈의 횡진동 특성에 미치는 영향)

  • Ha, Jin-Woong;Myung, Ji-Ho;Suk, Jhin-Ik;Lee, An-Sung;Kim, Young-Cheol
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.8
    • /
    • pp.752-760
    • /
    • 2011
  • In tilting pad bearing design process, the selection of the proper configuration type of either a load-between-pad(LBP) or load-on-pad(LOP) as well as preload and pivot offset conditions is to be carefully considered. Also the bearing needs to be designed in order to be suited for the rotor-bearing system and operating condition. In this paper, it is observed that the dynamic characteristics in a five pad tilting pad bearing for the LBP and the LOP configurations are influenced by the variation of preload and pivot offset. In this context, rotor dynamic analysis of the 5 MW industrial gas turbine supported by the tilting pad bearing at the front and roller bearing at the rear is carried out based on the dynamic coefficients of the tilting pad bearing investigated. The result shows that two rigid body critical modes experience various changes according to the influence of the tilting pad bearing uniquely applied to one side of this machine. Mainly, the second critical speed, the rigid body mode of conical shape with high whirling in the tilting pad bearing, is significantly changed by preload and pivot offset regardless of the LBP and LOP configurations. And, the first critical mode, the rigid body mode of conical shape with high whirling in the roller bearing, is sensitively affected by preload applied to the LOP configuration and by its asymmetric dynamic properties.

Effects of Design Conditions in Five Pad Tilting Pad Bearing on the Lateral Vibration Characteristics of Small Gas Turbine (5패드 틸팅 패드 베어링의 설계 조건 변화가 소형 가스터빈의 횡진동 특성에 미치는 영향)

  • Ha, Jin-Woong;Myung, Ji-Ho;Suk, Jhin-Ik;Lee, An-Sung;Kim, Young-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.425-432
    • /
    • 2011
  • In tilting pad bearing design process, the selection of the proper configuration type of either a Load-Between-Pad (LBP) or Load-On-Pad (LOP) as well as preload and pivot offset conditions is to be carefully considered. Also the bearing needs to be designed in order to be suited for the rotor-bearing system and operating condition. In this paper, it is observed that the dynamic characteristics in a 5 pad tilting pad bearing for the LBP and the LOP configurations are influenced by the variation of preload and pivot offset. In this context, rotor dynamic analysis of the 5MW industrial gas turbine supported by the tilting pad bearing at the front and roller bearing at the rear is carried out based on the dynamic coefficients of the tilting pad bearing investigated. The result shows that two rigid body critical modes experience various changes according to the influence of the tilting pad bearing uniquely applied to one side of this machine. Mainly, the second critical speed, the rigid body mode of conical shape with high whirling in the tilting pad bearing, is significantly changed by preload and pivot offset regardless of the LBP and LOP configurations. And, the first critical mode, the rigid body mode of conical shape with high whirling in the roller bearing, is sensitively affected by preload applied to the LOP configuration and by the its asymmetric dynamic properties.

  • PDF

A Study on the Behaviors of Column-to-Footing Connections for Concrete Filled Tube(CFT) System (콘크리트 충전 각형강관 주각부의 내력 및 변형에 관한 연구)

  • Kim, Cheol-Hwan;Kim, Seong-Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.3
    • /
    • pp.253-260
    • /
    • 2010
  • The purpose of this paper is to investigate the behavior of concrete-filled tube columns for footing connections. Eight specimens were tested to investigate such structural behavior according to the column base type. The specimens consisted of concrete-filled steel tube columns (or bare steel tube columns), reinforced concrete footings, and base plates (or stud connectors). The specimens were subjected to lateral cyclic load. The cyclic load was applied according to a predetermined strength sequence. The results of the experiment indicated that the flexural strength of the stud-connector- type column base is higher than that of the base-plate-type column base. The structural behavior of the concrete-filled tube column base was similar to that of the bare steel column base.