• Title/Summary/Keyword: Later pressure

Search Result 284, Processing Time 0.032 seconds

The Depressive effect of Sa-Am Acupuncture(膀胱正格) treatment in Stroke Patients (뇌졸중 환자에서 사암침의 혈압강하에 대한 고찰)

  • Park, Young-soo;Kim, Eun-mi;Kim, Young-il;Hong, Kwon-eui;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.21 no.4
    • /
    • pp.217-223
    • /
    • 2004
  • Objective: The aim of this research was to investigate the depressive effect of Sa-am Acupuncture(膀胱正格) in stroke patients. Methods: We measured the blood pressure of the patients who were admitted in the Oriental Medical hospital of Dae-Jeon University from June. 2003. to September. 2003. If systolic blood pressure was over 160mmHg or diastolic blood pressure was over 100 mmHg, 40 patients were treated by Sa-am Acupuncture(膀胱正格) and the other 20 patients were taken a rest in bed. Then 30 minutes and 60 minutes later, systolic, diastolic blood pressure were measured. Results: After 30 minute treatment, Sa-am Acupuncture(膀胱正格) significantly depressed the systolic and diastolic blood pressure, but bedrest can't do it. After 60 minute treatment, both Sa-am Acupuncture(膀胱正格) and bedrest significantly depressed the systolic and diastolic bood pressure. Conclusion: These results suggest that Sa-am Acupuncture(膀胱正格) is effective in depressing the systolic and diastolic blood pressure.

  • PDF

Hypertension in children and adolescents (소아 청소년기에서 고혈압)

  • Jung, Jo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.7
    • /
    • pp.745-751
    • /
    • 2009
  • Hypertension is a major risk factor for myocardial infarction, stroke, and cardiovascular mortality in adults; its treatment reduces the risk of cardiovascular events. In recent times, attention is being paid to monitoring of blood pressure from childhood to adulthood. Childhood hypertension is associated with hypertension in later life, and early intervention is important. In the Korean socioeconomic background, a rapid increase is observed in the number of obesity cases and the rate of increase in the incidence of obesity is more in childhood. The strong association of high blood pressure with obesity and the marked increase in the incidence of childhood obesity indicate that both hypertension and prehypertension are becoming significant health issues. In this comprehensive review, we acquaint the clinician with the available literature on childhood hypertension to provide recommendations for the diagnosis, evaluation, and treatment of hypertension based on the available evidence and consensus in Korean clinical conditions.

Effect of fuel octane number on knock characteristics in a spark-ignition engine (연료의 옥탄가 변화에 따른 스파크 점화기관의 노킹특성의 변화)

  • 이홍철;전광민
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.5
    • /
    • pp.61-68
    • /
    • 1992
  • Knock phenomenon is an abnormal combustion originated from autoignition of unburned gas in the end-gas region during the later stage of combustion process and it accompanys a high pitched metallic noise. Engine Knock is accompanied with a vibration of engine cylinder and when it is severe, it can cause major engine demage. Engine Knock is characterized in terms of knock crank angle, knock pressure, pressure jump and knock intensity. In this study, a 4-cylinder spark ignition engine was used for experiment and eighty consecutive cycles were analyzed statistically. The purpose of this study is to characterize spark ignition engine knock as a function of ignition timing and fuel research octane number. The result of this study can be summerized as follows. Knock occurrence angle approached TDC as ignition timing is advanced. Pressure and knock intensity gradually increased as spark timing is advanced. Mean knock occurence angle gradually approached TDC as fuel research octane number is decreased for identical spark timing. Knock intensity increased linearly as RON is decreased.

  • PDF

The Development of UV Blocking Type Pressure-Sensitive Adhesive Sheet for Window (자외선이 차단되는 창문용 점착시트 개발에 관한 연구)

  • Kim, Sung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.559-564
    • /
    • 2011
  • The UV blocking type pressure-sensitive adhesive sheet was developed by mixing UV blocking reagent with adhesive material, instead of conventional method in which the reagent was mixed with PVC substrate. The blocking performance of the sheet was evaluated by measuring the absorbance in 280-400 nm region. Both organic and inorganic type blocking reagents were examined. The blocking ability of the former is better than that of the later. Only 1% addition of blocking reagents is effective to block UV light without affecting to visibility and tackiness of adhesive tapes.

On the $NO_x$ in Direct Injection diesel engine (직접분사식 디이젤의$NO_x$에 관하여)

  • 안수길
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 1976
  • To investigate the relation of $NO_x$ emission and consumption rate in a direct injection diesel engine with a multihole nozzle under same fuel consumption and rpm, a naphthyl ethylenediaming method on NO, emission and Tektronix oscilloscop on the indicator diagrams have been used. Comparisons of the $NO_x$ emission and fuel consumption rate made on various conditions have led to the fllowing results. 1. The higher the injection pressure in the later injection time the lower $NO_x$ emission and the fuel consumption rate have been attained. 2. By the change of nozzle hole diameter under the same injection pressure, the $NO_x$ emission was much more lowered in the small diameter than large one, but fuel consumption rate was in inverse proption to the $NO_x$ emission. 3. The effect of injection spray angle, $\frac{1_n}{d_n}$ on $NO_x$ emission, fuel consumption rate under same injection time and injection pressure was neglectable.

  • PDF

EXPERIMENTS ON THE PERFORMANCE SENSITIVITY OF THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN ADVANCED INTEGRAL TYPE REACTOR

  • Park, Hyun-Sik;Choi, Ki-Yong;Choi, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.53-62
    • /
    • 2009
  • A set of experiments has been conducted on the performance sensitivity of the passive residual heat removal system (PRHRS) for an advanced integral type reactor, SMART, by using a high temperature and high pressure thermal-hydraulic test facility, the VISTA facility. In this paper the effects of the opening delay of the PRHRS bypass valves and the closing delay of the secondary system isolation valves, and the initial water level and the initial pressure of the compensating tank (CT) are investigated. During the reference test a stable flow occurs in a natural circulation loop that is composed of a steam generator secondary side, a secondary system, and a PRHRS; this is ascertained by a repetition test. When the PRHRS bypass valves are operated 10 seconds later than the secondary system isolation valves, the primary system is not properly cooled. When the secondary system isolation valves are operated 10 or 30 seconds later than the PRHRS bypass valves, the primary system is effectively cooled but the inventory of the PRHRS CT is drained earlier. As the initial water level of the CT is lowered to 16% of the full water level, the water is quickly drained and then nitrogen gas is introduced into the PRHRS, resulting in the deterioration of the PRHRS performance. When the initial pressure of the PRHRS is at 0.1MPa, the natural circulation is not performed properly. When the initial pressures of the PRHRS are 2.5 or 3.5 MPa, they show better performance than did the reference test.

Postlaminectomy Arteriovenous Fistula -Report of a case- (요추궁 절제술후 발생한 동정맥루 -1례 보고-)

  • 이정호
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.130-133
    • /
    • 1980
  • Since the first report of an operation for prolapsed intervertebral disk by Mixter and Barr[1934], many thousands of operations have been successfully performed without incident. Linton and White in 1945 reported the vascular complication, but perforation of large vessels is rare complication of operation for prolapsed disk. A medical student, aged 22 years, was performed to a disk operation [L4-5, Rt. on May 1977.] From postoperative 10th day, palpitation, generalized edema and substernal pain were noted, and 2 months later, wide pulse pressure [70-80 mmHg], continuous bruit and thrill on the Rt. low abdomen were followed. Aortography revealed arteriovenous fistula between just proximal to abdominal aortic bifurcation and inferior vena cava. So, fistulectomy [Resection of proximal 2 cm of C.I.A., Rt, including fistula opening and end to end anastomosis] was performed on July, 77. During follow up study, remained fistula between Rt. internal lilac artery and lilac vein was found 2 months later. Re-operation [Double ligation of the Rt. internal lilac artery] was don on January 1978. Postop. results were excellent, except impossible to ejaculation.

  • PDF

Development of Pressure Sensor for Identifying Guinea Pig's Large Intestinal Motility Caused by Drug (약물 투여에 따른 기니피그 대장 운동 측정을 위한 압력센서 개발)

  • Park, Jae-Soon;Park, Jung-Ho;Kim, Eung-Bo;Cho, Sung-Hwan;Jang, Su-Jeong;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.1
    • /
    • pp.23-29
    • /
    • 2016
  • In this paper, in order to quantify the peristalsis occurrence in a guinea pig's large intestine, a miniaturized air-gap capacitive pressure sensor was fabricated through micro-electro-mechanical system (MEMS). The proposed pressure sensor is a two-layered biocompatible polyimide substrate consisting of an air-gap capacitive plates between the substrates. The proposed pressure sensor was designed with a careful consideration of the structure and motility mechanism of the guinea pig's large intestine. Artificial pellets were mounted on a prototype pressure sensor to provide some redundancies in the form of size and shape of the guinea pig feces. Capacitance of a prototype sensor was recorded to be 2.5 ~ 3 pF. This capacitance value was later converted to count value using a lab fabricated data conversion system. Sensitivity of the pressure sensor was recorded to be below 1 mmHg per atmospheric pressure. During in vivo testing, artificial peristalsis caused by drug injection was measured by inserting the prototype pressure sensor into the guinea pig's large intestine and pressure data obtained due to artificial peristalsis was graphed using a labview program. The proposed pressure sensor could measure the pressure changes in the proximal, medial, and distal parts of the large intestine. The results of the experiment confirmed that pressure changes of guinea pig's large intestine was proportional to the degree of drug injection.

Quantitative Estimation of Radiation Damage in Reactor Pressure Vessel Steels by Using Multiscale Modeling (멀티스케일 모델링을 이용한 압력용기강의 조사손상 정량예측)

  • Lee, Gyeong-Geun;Kwon, Junhyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.113-121
    • /
    • 2014
  • In this work, an integrated model including molecular dynamics and chemical rate theory was implemented to calculate the growth of point defect clusters(PDC) and copper-rich precipitates(CRP) which could change the mechanical properties of reactor pressure vessel(RPV) steels in a nuclear power plant. A number of time-dependent differential equations were established and numerically integrated to estimate the evolution of irradiation defects. The calculation showed that the concentration of the vacancies was higher than that of the self-interstitial atoms. The higher concentration of vacancies induced a formation of the CRPs in the later stage. The size of the CRPs was used to estimate the mechanical property changes in RPV steels, as is the same case with the PDCs. The calculation results were compared with the measured values of yield strength change and Charpy V-notch transition temperature shift, which were obtained from the surveillance test data of Korean light water reactors(LWRs). The estimated values were in fair agreement with the experimental results in spite of the uncertainty of the modeling parameters.

Process Diagnosis of Reactive Deposition of MgO by ICP Sputtering System (유도결합 플라즈마 스퍼터링 장치에서 MgO의 반응성 증착 시 공정 진단)

  • Joo, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.5
    • /
    • pp.206-211
    • /
    • 2012
  • Process analysis was carried out during deposition of MgO by inductively coupled plasma assisted reactive magnetron sputtering in Ar and $O_2$ ambient. At the initiation of Mg sputtering with bipolar pulsed dc power in Ar ambient, total pressure showed sharp increase and then slow fall. To analyse partial pressure change, QMS was used in downstream region, where the total pressure was maintained as low as $10^{-5}$ Torr during plasma processing, good for ion source and quadrupole operation. At base pressure, the major impurity was $H_2O$ and the second major impurity was $CO/N_2$ about 10%. During sputtering of Mg in Ar, $H_2$ soared up to 10.7% of Ar and remained as the major impurity during all the later process time. When $O_2$ was mixed with Ar, the partial pressure of Ar decreased in proportion to $O_2$ flow rate and that of $H_2$ dropped down to 2%. It was understood as Mg target surface was oxidized to stop $H_2$ emission by Ar ion sputtering. With ICP turned on, the major impurity $H_2$ was converted into $H_2O$ consuming $O_2$ and C was also oxidized to evolve CO and $CO_2$.