• 제목/요약/키워드: Latent Heat

검색결과 641건 처리시간 0.03초

PCM을 이용한 온돌패널의 실험 및 특성연구 (Experiment and Property Study of Ondol Panel Based on Phase Change Material)

  • 윤두한;최봉수;홍희기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.122-125
    • /
    • 2006
  • This paper deals with the Ondol, Korean under-floor heating system using latent heat storage materials. It has been recognized that the heating system using the latent heat storage materials are economically efficient and comfortable. For the comparison and analysis to the data of the existing experiment, a repetitive experiment makes sure the ability of Ondol panel.

  • PDF

고온 축열 시스템의 개발에 관한 연구 (A System Development of Thermal Energy Storage at High Temperatures)

  • 홍성안;박원훈;최형준
    • 태양에너지
    • /
    • 제8권1호
    • /
    • pp.13-21
    • /
    • 1988
  • Heat transfer phenomena in a high-temperature heat storage unit were investigated using molten salts. Carbonate salt, an equimolar mixture of $Li_2CO_3$ and $K_2CO_3$, which melts at $505^{\circ}C$ with a latent heat of 82 cal/g, was selected as the most promising latent heat storage material based on its low cost and excellent thermophysical properties at moderately high temperatures. It was also found that nitrate salts were good candidates of sensible heat storage materials. For the carbonate salt to be utilized commercially, however, several means of enhancing thermal recovery must be explored by promoting heat conduction through the solid salt formed during the heat discharge period. These would be achieved by the additions of aluminum screens and wool, and stainless fins. Finally, experimental results of moving boundary of phase change were well compared with predictied values obtained from the approximate solution.

  • PDF

PCM의 잠열측정을 위한 T-history법에 대한 고찰 (Consideration on the T-history Method for Measuring Heat of Fusion of Phase Change Materials)

  • 박창현;최주환;홍희기
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1223-1229
    • /
    • 2001
  • Though conventional calorimetry methods such as differential scanning calorimetry (DSC) and differential thermal analysis (DTA) are used generally in measuring heat of fusion, T-history method has the advantages of a simple experimental apparatus and no requirements of sampling process, which is particularly useful for measuring thermal properties of inhomogeneous phase change materials (PCMs) in sealed tubes. However, random criteria (a degree of supercooling) used in selecting the range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion. In the present study, it was shown that a 40% discrepancy exists between the original T-history and the present methods when analyzing the same experimental data. As a result, a reasonable modification to the original T-history method is proposed.

  • PDF

해안 대기 표층의 난류와 해안 대기 경계층의 구조 (Turbulence of the Coastal Atmospheric Surface Layer and Structure of the Coastal Atmospheric Boundary Layer)

  • 권병혁
    • 수산해양교육연구
    • /
    • 제17권3호
    • /
    • pp.404-412
    • /
    • 2005
  • The surface energy budget depends on many factors, such as the type of surface, the soil moisture and the vegetation canopy, the geographical location, daily, monthly and seasonal variations, and weather conditions. In the coastal region, the surface is not homogeneous at various scales for instance water, sand, mud, tall grass, and crops. The energy balance over the vegetation canopy was analyzed with the optical energy balance measuring system. The latent heat flux was more intensive than the sensible heat flux. The sensible heat flux was very small in summer due to the canopy effect and higher in spring and autumn. In summer the development of the atmospheric boundary depended on rather the vertical shear of wind than the sensible heat flux.

Improvement of the T-history Method to Measure Heat of Fusion for Phase Change Materials

  • Hong, Hi-Ki;Park, Chang-Hyun;Choi, Ju-Hwan;Peek, Jong-Hyeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권1호
    • /
    • pp.32-39
    • /
    • 2003
  • Though conventional calorimetry methods such as differential scanning calorimetry and differential thermal analysis are used generally in measuring heat of fusion, T-history method has advantages of a simple experimental apparatus and no requirements of sampling process, which is particularly useful for measuring thermophyical properties of in-homogeneous phase change materials in sealed tubes. However, the degree of supercooling used in selecting a range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion. In the present study, it was shown that a 40% discrepancy exists between the original T-history and the present methods when analyzing the same experimental data. As a result, a reasonable modification to the original T-history method is proposed.

반도체 식각 공정용 냉각 시스템 구축을 위한 AMESim 모델 개발 (A Study on the Development of AMESim Model for Construction of Cooling System for Semiconductor Etching Process)

  • 김대현;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제16권3호
    • /
    • pp.106-110
    • /
    • 2017
  • Due to the plasma applied from the outside, which acts as an etchant during the etching process, considerable heat is transferred to the wafer and a separate cooling process is performed to effectively remove the heat after the process. In this case, a direct cooling method using a refrigerant is suitable for cooling through effective heat exchange. The direct cooling method using the refrigerant using the latent heat exchange is superior to the cooling method using the sensible heat exchange. Therefore, in this paper, AMESim is used to design a direct refrigerant cooling system using latent heat exchange simulator was built.The constructed simulator is reliable compared with the actual experimental results. It is expected that this simulator will help to design and search for optimal process conditions.

  • PDF

식각 공정용 냉각시스템에서의 직접 냉각 방식과 간접 냉각 방식에 관한 연구 (A Study on Direct Cooling and Indirect Cooling in Etching Process Cooling System)

  • 장경민;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제17권3호
    • /
    • pp.100-103
    • /
    • 2018
  • Due to the plasma applied from the outside, which acts as an etchant during the etching process, considerable heat is transferred to the wafer and a separate cooling process is performed to effectively remove the heat after the process. In this case, a direct cooling method using a refrigerant is suitable for cooling through effective heat exchange. The direct cooling method using the refrigerant using the latent heat exchange is superior to the cooling method using the sensible heat exchange. Therefore, in this paper, AMESim is used to design a direct refrigerant cooling system using latent heat exchange simulator was built.The constructed simulator is reliable compared with the actual experimental results. It is expected that this simulator will help to design and search for optimal process conditions.

수증기의 잠열을 이용한 메탄올 수증기 개질기의 특성 연구 (Study on the Characteristics of Methanol Steam Reformer Using Latent Heat of Steam)

  • 천욱래;안강섭;신현길
    • 한국수소및신에너지학회논문집
    • /
    • 제29권1호
    • /
    • pp.19-24
    • /
    • 2018
  • Fuel cells are used to generate electricity with a reformer. In particular, methanol has various advantages among the fuels for reformer. Methanol steam reformer devices can efficiently supply hydrogen to PEM fuel cell. This study investigated the optimal operation conditions of a methanol steam reforming process. For this purpose, aspen HYSYS was used for the optimization of reforming process. The optimal operating condition could be designed by setting independent variables such as temperature, pressure and steam to carbon ratio (SCR). The optimal temperature and steam to carbon ratio were $250-270^{\circ}C$ and 1.3-1.5, respectively. It is advantageous to operate at a pressure of 15-20 barg, considering the performance of the hydrogen purifier. In addition, a heat exchange network was designed to supply heat constantly to reformer through the latent heat of steam.

Analysis of Time Variations in Relative Humidity around a Water Area Using Bowen Ratio

  • Kim, Ki-Young;Kim, Kyu-Rang;Kim, Hae-Dong
    • 한국환경과학회지
    • /
    • 제23권10호
    • /
    • pp.1731-1743
    • /
    • 2014
  • The time variations in relative humidity observed at the Gangjeong (Goryeong) Reservoir in the Nakdong River over a one-year period (September 2012-August 2013) were analyzed with the Bowen ratio. The thermal vertical scale of the reservoir was also evaluated following Yamamoto's method. The study's results showed that the relative humidity at the reservoir was higher than that of the Daegu Meteorological Observatory (inland) all year round. The difference was slightly larger at nighttime (17-20 %) than at daytime (13-15 %) in all seasons except summer. The quantitative order of latent heat flux was summer, spring, autumn, and winter. This finding signifies that the thermal vertical scale of the reservoir corresponds to that of a shallow lake. The Bowen ratio was smallest at midday of the summer season. In other words, the net radiation energy was converted more as latent heat flux than sensible heat flux during a higher temperature period.

유기잠열재, $C_{28}H_{58}$과 무기잠열재, $CH_3COONa{\cdot}3H_2O$의 잠열특성연구 (Study on the Latent Heat Characteristics of the Organic Compound, $C_{28}H_{58}$ and the Inorganic Compound, $CH_3COONa{\cdot}3H_2O$)

  • 송현갑;유영선
    • 태양에너지
    • /
    • 제11권3호
    • /
    • pp.53-61
    • /
    • 1991
  • 본 연구에서는 심야전력 및 폐열의 회수이용을 위한 잠열축열재를 개발하기 위하여, 상변화 온도가 $50{\sim}80^{\circ}C$의 범위에 있는 상변화 물질중 잠열량이 크고, 물성안정이 비교적 용이한 Octacosane($C_{28}H_{58}$)과 Sodium Acetate Trihydrate($CH_3COONa{\cdot}3H_2O$)를 선택하여 상변화 온도의 변화특성과 물성안정방법 그리고 잠열특성을 분석하여 다음과 같은 결과를 얻었다. 1. 공업용 수준 Octacosane과 Sodium Acetate Trihydrate의 상변화 온도는 각각 $60.7^{\circ}C,\;57.4^{\circ}C$로서 시약용 수준에 비하여 Octacosane은 $1.1^{\circ}C$, Sodium Acetate Trihydrate는 $0.6^{\circ}C$ 낮았으며, 잠열량에 있어서는 Octacosane은 60.6kcal/kg으로 시약용 수준과 비슷한 값을 보였으나, Sodium Acetate Trihydrate는 51.1kcal/kg으로 시약용 수준에 비하여 5.4% 작은 값을 나타내었다. 2. Octacosane의 상변화 사이를 증가에 따른 잠열량을 분석한 결과, 초기에는 60.6kcal/kg이었으나, 시약용의 증가와 더불어 점차로 감소하여 200cycle에서 47.2kcal/kg이 되었고, 그 이후에는 거의 일정한 값을 유지하고 있는 것으로 보아 더 이상의 잠열량 감소는 없을 것으로 판단된다. 3. Sodium Acetate Trihydrate의 과냉현상을 제어하기 위한 조핵제로서 SPD(Sodium Pyrophosphate Decahydrate)를 3wt 이상 첨가하여 $25.7^{\circ}C$의 과냉도를 $1^{\circ}C$ 미만으로 줄였고, 증점제로서 CMC-Na를 3wt% 이상 첨가하여 상분리 현상을 해결하였으며, 안전성을 고려한 조핵제 및 중점제의 적정 첨가량은 4wt%였다. 4. UREA($NH_2CONH_2$)를 첨가하여 Sodium Acetate Trihydrate($CH_3COONa{\cdot}3H_2O$)의 상변화 온도를 $57.4^{\circ}C$에서 $46.2^{\circ}C$까지 다양하게 변화시켜 이용온도 수준에 적합한 잠열축열재를 선택할 수 있도록 하였으며, UREA 함량에 따른 잠열량을 분석한 결과 UREA의 함량이 증가함에 따라 잠열량이 점차로 감소하여 10wt%의 UREA를 첨가하였을 경우에는 38.3kcal/kg였으며, UREA의 함량이 20wt%까지 증가하는 동안 더 이상의 잠열량 감소는 없었다. 5. $30^{\circ}C$에서 $90^{\circ}C$까지의 가열과정에서 현열재인 물, 그리고 돌(화강암)과 잠열축열재의 축열량을 비교 분석한 결과, Octacosane은 상변화 온도 $60{\sim}70^{\circ}C$에서의 축열량이 물의 2.45배, 돌의 12.5배였으며, S.A.T.(Sodium Acetate Trihydrate)는 상변화 온도 $57.4^{\circ}C$에서의 축열량이 물보다 2.53배, 돌보다는 12.91배 큰 것으로 나타났다.

  • PDF