• Title/Summary/Keyword: Laser types

Search Result 391, Processing Time 0.028 seconds

Solidification Cracking Behavior in Austenitic Stainless Steel Laser Welds (Part 1) - Evaluation of Solidification Cracking Susceptibility by Laser Beam Welding Varestraint Test - (오스테나이트계 스테인리스강 레이저 용접부의 응고균열 거동 (Part 1) - 레이저 용접용 Varestraint 시험 시스템을 이용한 응고균열 민감도 평가 -)

  • Chun, Eun-Joon;Lee, Su-Jin;Suh, Jeong;Kang, Namhyun;Saida, Kazuyoshi
    • Journal of Welding and Joining
    • /
    • v.34 no.5
    • /
    • pp.54-60
    • /
    • 2016
  • In order to quantitatively evaluate the solidification cracking susceptibility in laser welds of three types of austenitic stainless steels (type 310: A mode, type 316-A: AF mode, type 316-B: FA mode solidifications), the laser beam welding (LBW) transverse-Varestraint tests consisted of multi-mode fiber laser, welding robot and hydraulic pressure system were performed. As the welding speed increased from 1.67 to 40.0 mm/s, the solidification brittle temperature range (BTR) of laser welds for type 316 stainless steels enlarged (316-A: from 37 to 46 K, 316-B: from 14 to 40 K), while the BTR for type 310 stainless steel reduced from 146 to 120 K. In other words, it founds that solidification cracking susceptibility could not be simply mitigated through application of LBW process, and the BTR variation behavior is quite different upon solidification mode of austenitic stainless steels.

Optimization of selective laser sintering process parameter for Fe-Ni-Cr coating fabrication (Fe-Ni-Cr 코팅층 형성을 위한 SLS 공정변수의 최적화)

  • Joo, B.D.;Jang, J.H.;Yim, H.S.;Son, Y.M.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.278-281
    • /
    • 2009
  • Selective laser sintering(SLS), a kind of rapid prototyping technology, can provide a process to form many types of coatings. Coated layers by selective laser melting are highly influenced by substrate, powder and laser parameters such as laser power, scan rate, fill spacing and layer thickness. Therefore an attempt to fabricate Fe-Ni-Cr coating on AISI H13 tool steel has been performed by selective laser sintering. In this study, Fe-Ni-Cr coating was produced by experimental facilities consisting of a 200W fiber laser which can be focused to 0.08mm and atmospheric chamber which can control atmospheric pressure with Ar. With power increase or energy density decrease, line width was decreased and line surface quality was improved with energy density increase. Surface quality of coating layer was improved with fill spacing optimization or layer thickness decrease.

  • PDF

Laser Doppler Vibrometer with Self Vibration Compensation (자체 진동 보상기능을 가진 레이저 도플러 진동측정계에 관한 연구)

  • Lee, Young-Jin;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.53-55
    • /
    • 2001
  • A dual probe laser Doppler vibrometer (LDV) that has one laser source and provides two independent object beams has been developed for the first time. An electronic circuit that converts light signal to electronic signal has been also developed using phase locked loop(PLL). It was found that this types of dual probe LDV can be used in differential mode and self-vibration compensation mode.

  • PDF

Laser Doppler Vibrometer with self vibration compensation (자체 진동 보상기능을 가진 레이저 도플러 진동측정계에 관한 연구)

  • Lee, Young-Jin;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1838-1840
    • /
    • 2001
  • A dual probe laser Doppler vibrometer (LDV) that has one laser source and provides two independent object beams has been developed for the first time. An electronic circuit that converts light signal to electronic signal has been also developed using digital phase locked loop(DPLL). It was found that this types of dual probe LDV can be used in differential mode and self-vibration compensation mode.

  • PDF

Fundamentals and Research Trend of Laser Acupuncture (레이저침의 원리와 연구동향 분석)

  • Kim, Hyun-Ho;Nam, Dong-Woo;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.26 no.6
    • /
    • pp.21-30
    • /
    • 2009
  • Objectives : Being introduced in the 1980s, laser acupuncture studies have been steadily carried on such as its thermal effects on human body. However, the mechanisms of effect are not yet clearly explained. Generally, laser acupuncture could be favorable for pediatric patients or people under special conditions (hemophilia, needle-phobia, pathogen-carriers, etc.) because of lower risk of infection, bleeding, pain or fainting. But there are still problems for using laser acupuncture equivalently as the traditional metal needle. The goal of this study is to review the fundamentals, history and present trend of laser acupuncture study, and to suggest how to develop laser acupuncture as an oriental medical device. Method : We performed literature search using PubMed(http://www.ncbi.nlm.nih.gov/pubmed) and Scopus(http://www.scopus.com). Search conditions are laser acupuncture, laser needle, LLLT(as title or abstract) or Litscher G(as author). Main target studies are physical fundamentals, clinical trials, physiological results and device proposals. Results : Many research have shown the similarities of laser acupuncture and traditional metal acupuncture and have reported clinical and physiological effects of laser acupuncture. But, still laser acupuncture is not widely used in Korea due to high-cost of equipments and the lack of clear understanding of laser devices. Additionally, there are still challenges in standardization and device development. Conclusions : Frequencies, laser modes, waveguides, adaptor types, polarization and signal modulations are suggested as future study subjects on laser acupuncture. More various studies and efforts for device development have to be performed to provide oriental medical doctors with evidence based confidence about usage of laser acupuncture.

  • PDF

Measuring and Characterizing the Apparent Thickness and its Irregularity of Fine Wire Bundle by Using a Laser Scanning Method (Laser Scanning을 이용한 극세선 집속체의 겉보기 굵기 측정과 불균제 특성)

  • Huh, Y.;Kim, J.S.;Baik, Y.N.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1573-1576
    • /
    • 2003
  • The quality of bundles is closely related with the apparent thickness. Especially the variation of apparent thickness of bundle determines the qualify of the plane structure made or the bundle such as surface evenness, pore size, and the shape of air-gap, etc.,. This study is dealing with the development of a new measuring system of the thickness of bundle or cross-section by determining the size of the shadow of the object covered by a laser slit beam. Also the measured signal is characterized in terms of the correlogram, the irregularity in wavelength. The correlogram for the irregularity of several sample types could be represented by a sinusoidal function with exponentially decaying amplitude. Moreover, influence of the measuring speed on the signal and the characteristic differences according to the different types of bundle are investigated.

  • PDF

Effects of Low Incident Energy Levels of Infrared Laser Irradiation on the Proliferation of Candida Albicans Part I : A Long Term Study according to Pulse Type

  • Sam-Kun Kim;Phil-Yeon Lee;Ki-Suk Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.1
    • /
    • pp.9-15
    • /
    • 1994
  • This experiment was performed to confirm the hypothesis that LLLT had biostimulation effect for all kinds of cells and there would be differences in the growth of cells among different types of pulsed laser. 360 samples were used in this study. The samples were randomly divided in 6 groups according to the pulse type : quasi continuous type (CW), pulse 1(P1), pulse 7(P7), pulse 9(P9), pulse 15(P15) and shame-irradiated control(Co) groups. Energy fluences of all experimental groups, P1, P7, P9, P15 and CW were 2.12, 2.12, 6.37, 57.32 and 31.85 mj/cm2 respectively. All samples were irradiated for every 1 minute at 0, 12, 24, 36, 48 and 60 hours. Ten samples of each group were sacrificed at 0 and every 12 hours and then the optical density of all samples was measured with the spectrophotometer. As a result, some types of pulses showed significant differences among groups. The increase of cells were markedly stimulated with laser irradiation in P7 and P9 groups, while inhibited in CW, P1, and P15 groups compared with control group. It is therefore, suggested that specific laser pulse should be recommanded to have the biostimulation effects on the specific tissue or cells, although the biostimulation effect is does dependant.

  • PDF

Low-threshold Photonic Crystal Lasers from InGaAsP Free-standing Slab Structures

  • Ryu, Han-Youl;Kim, Se-Heom;Kwon, Soon-Hong;Park, Hong-Gyu;Lee, Yong-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.6 no.3
    • /
    • pp.59-71
    • /
    • 2002
  • Photonic band gap structures have a high potential for nearly zero-threshold lasers. This paper describes new-types of low-threshold photonic crystal lasers fabricated in InGaAsP slab waveguides free-standing in air. Two-types of photonic crystal lasers are studied. One is a single-cell nano-cavity laser formed in a square array of air holes. This photonic band gap laser operates in the smallest possible whispering gallery mode with a theoretical Q >30000 and exhibits low threshold pump power of 0.8 mW at room temperature. The nther laser does not have any cavity structure and the lasing operation originates from the enhanced optical density of states near photonic band edges. A very low threshold of 35 $\mu$W (incident pump power) is achieved from this laser at 80 K, one of the lowest values ever reported. This low threshold is benefited from low optical losses as well as enhanced material gain at low temperature.

The treatment of peri-implantitis using various types of lasers (다양한 Laser를 이용한 Peri-Implantitis의 치료)

  • You, Jae-Seek;Kim, Su-Gwan;Ahn, Jong-Mo
    • The Journal of the Korean dental association
    • /
    • v.53 no.12
    • /
    • pp.906-909
    • /
    • 2015
  • Peri-implantitis is the inflammatory process, such as edema, bleeding, pus, of the mucosa surrounding dental implants. As the symptoms become severe, the surrounding bone is absorbed causing the implant surface to be exposed. Clinicians treat periimplantitis in various ways since a gold standard for the treatment of peri-implantitis has not been established. Various treatment methods include mechanical, chemical surface treatment and surgical excision, and recently decontamination of the implant surface using various types of lasers has been proposed. Thus, this study reviews the types of lasers and its effects that can be used for the treatment of peri-implantitis.

Surface Transformation Hardening for Rod-shaped Carbon Steels by High Power Diode Laser (고출력 다이오드 레이저(HPDL)를 이용한 탄소강 환봉의 표면변태경화)

  • Kim, Jong-Do;Kil, Byung-Lea;Kang, Woon-Ju
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.961-969
    • /
    • 2007
  • The laser material processing has replaced a conventional material processing such as a welding, cutting, drilling and surface modification and so on. LTH(Laser Transformation Hardening) is one branch of the laser surface modification process. A lot of energy is needed for the LTH process to elevate workpiece surface to temperature of the austenite transformation($A_3$), which results from utilizing a beam with a larger size and lower power intensity comparatively. The absorptivity of the laser energy with respect to material depends on the wave length of a beam. This study is related to the surface hardening for the rod-shaped carbon steel by the high power diode laser(HPDL) whose beam absorptivity is better than conventional types of lasers such as $CO_2$ or Nd:YAG laser. Because a beam proceeds on the rotating specimen the pretreated hardened-phase can be tempered and softened by the overlapping between hardened tracks. Accordingly, the longitudinal hardness measurement and observation of the micro structure was carried out for an assessment of the hardening characteristics. In addition, a hardening characteristics as a hardenability of materials was compared in the point of view of the hardness distribution and hardening depth and width.