• Title/Summary/Keyword: Laser safety

Search Result 342, Processing Time 0.029 seconds

Development of Safety Monitoring System for Operating Railway Tunnel (운용중인 철도터널의 안전관리 시스템 시범구축)

  • Lee, Su-Hyung;Shin, Min-Ho;Kim, Hyun-Ki
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.73-78
    • /
    • 2008
  • There has been need for safety monitoring systems for the social infrastructures. These infrastructures are subject to degradation over time, reduced functionality, and loss of functionality as a result of factors such as a wide variety of installation environments, natural disasters, and nearby work. Therefore, it is necessary to perform appropriate inspections, repairs, and renovations to ensure safe and efficient maintenance and operation. This paper introduces the example of the development of the safety monitoring system for operating railway tunnel. Tunnel profile measuring system using laser beam, crack gauges, accelerometer and a pluviometer were implemented to monitor the safety of a deteriorated tunnel. The measured data were transferred through wireless network and analyzed in real time. The safety criteria for tunnel stabilities and train operations are also discussed.

  • PDF

Evaluation of the Alternative Safety Signs for the Hazard of Nano Materials (나노 물질 안전보건 표지 대안들에 대한 평가)

  • Park, Jae-Hee;Yoo, Hyun-Seung;Smith-Jackson, Tonya
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.1
    • /
    • pp.79-86
    • /
    • 2010
  • Although nano materials are used a lot in industries, there has not been any standard nano hazard graphic symbol. An experiment was conducted to know the comprehension ratio of newly designed eight nano graphic symbols. To compare the symbols with existing safety graphic symbols, other sixteen symbols were also included. 54 subjects evaluated the difficulties of graphic symbols on seven point Likert scale and answered the meaning for each symbol. The all eight nano safety symbols marked under 30% comprehension ratio. However, one of them didn't show any statistically significant difference with other existing safety symbols as like bio hazard, radiation, and laser. Therefore the nano symbol tested in the best could be adopted as the nano safety graphic symbol if it is sufficiently exposed in training period and used with warning label. The workers in industries using nano materials can be alerted and protect themselves where the sign is attached.

Laser-assisted Delivery of a Combined Antioxidant Formulation Enhances the Clinical Efficacy of Fractional Microneedle Radiofrequency Treatment: A Pilot Study

  • Kim, Jihee;Kim, Soo Min;Jung, Bok Ki;Oh, Sang Ho;Kim, Young-Koo;Lee, Ju Hee
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.161-169
    • /
    • 2021
  • Background and Objectives Fractional microneedle radiofrequency systems are popular options to increase elasticity in aging skin. Laser-assisted drug delivery is a promising method for the epidermal injection of topically applied drugs and cosmetic ingredients. This study assesses the safety and efficacy of topical delivery of L-ascorbic acid, vitamin E, and ferulic acid after fractional microneedle radiofrequency treatment for reducing photodamage. Materials and Methods In this prospective, single-center, split-face, controlled pilot study, six women (mean age, 48.0 years; range, 35-57 years; Fitzpatrick skin types III and IV) exhibiting mild to moderate photodamage, underwent a single session of fractional microneedle radiofrequency treatment. The patients were instructed to apply the antioxidant formulation to only one side of the face. Patients were evaluated 3 days, 7 days, and 4 weeks thereafter, using three-dimensional imaging and ultrasound. Ex vivo, the full-thickness human skin was used for molecular and histological evaluation. Statistical analysis was achieved by applying t-tests, Mann-Whitney U tests, and one-way analyses of variance. Results Compared to the untreated side, the antioxidant-treated side exhibited a significant increase in dermal thickness (10.32% vs. 17.54%, p < 0.05), but not in skin elasticity (4.76% vs. 4.69%, p > 0.05). The difference in erythema between the sides was statistically not significant (p > 0.05). In the ex vivo model, expression of FGF2 in the skin was significantly increased after application of the antioxidant formulation, as compared to results obtained subsequent to fractional microneedle radiofrequency treatment only (p < 0.01). Conclusion This study demonstrates that for the treatment of photodamaged skin, laser-assisted delivery of the antioxidant formulation is a safe and effective adjuvant modality following fractional microneedle radiofrequency.

GEO-KOMPSAT-2 Laser Ranging Time Slot Analysis (정지궤도복합위성 레이저 레인징 가능 시간대 해석)

  • Park, Bongkyu;Choi, Jaedong;Lee, Sang-Ryool
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.1
    • /
    • pp.10-16
    • /
    • 2018
  • In 2018 and 2019, GEO-KOMPSAT-2A and GEO-KOMPSAT-2B will be launched in order to succeed the COMS mission. The two satellites will be collocated in $128.25{\pm}0.05$ degrees East. For precise ranging and orbit determination, the GEO-KOMPSAT-2B will be equipped with LRA (Laser Retroreflector Assembly) and SLR (Satellite Laser Ranging) systems will be utilized. This systems are located in Geochang. In this case, the laser beam emitted from the SLR station can cause problems in terms of safety of optical payloads and image quality. As a solution of this possibility, the laser ranging will be done during the night time when the shutters of the optical payloads remain closed. Still, the optical payload of the GEO-KOMPSAT-2A is not safe from the laser beam because its optical payload shall continue its mission for 24 hours a day. In order to handle this problem, the laser ranging shall be limited to time slots when the angular distance between two satellites observed from the Geochang SLR station is large enough. In this paper, through orbit simulations, the characteristics of variation of the angular distance between the two satellites is analyzed to figure out the time slots when laser ranging is allowed.

A deep neural network to automatically calculate the safety grade of a deteriorating building

  • Seungho Kim;Jae-Min Lee;Moonyoung Choi;Sangyong Kim
    • Smart Structures and Systems
    • /
    • v.33 no.4
    • /
    • pp.313-323
    • /
    • 2024
  • Deterioration of buildings is one of the biggest problems in modern society, and the importance of a safety diagnosis for old buildings is increasing. Therefore, most countries have legal maintenance and safety diagnosis regulations. However, the reliability of the existing safety diagnostic processes is reduced because they involve subjective judgments in the data collection. In addition, unstructured tasks increase rework rates, which are time-consuming and not cost-effective. Therefore, This paper proposed the method that can calculate the safety grade of deterioration automatically. For this, a DNN structure is generated by using existing precision inspection data and precision safety diagnostic data, and an objective building safety grade is calculated by applying status evaluation data obtained with a UAV, a laser scanner, and reverse engineering 3D models. This automated process is applied to 20 old buildings, taking about 40% less time than needed for a safety diagnosis from the existing manual operation based on the same building area. Subsequently, this study compares the resulting value for the safety grade with the already existing value to verify the accuracy of the grade calculation process, constructing the DNN with high accuracy at about 90%. This is expected to improve the reliability of aging buildings in the future, saving money and time compared to existing technologies, improving economic efficiency.

The Study on an Automated Generation Method of Road Drawings using Road Survey Vehicle (도로교통안전점검차량을 이용한 도로의 자동도면화 생성 연구)

  • Lee, Jun Seok;Yun, Duk Geun;Park, Jae Hong
    • International Journal of Highway Engineering
    • /
    • v.16 no.5
    • /
    • pp.91-98
    • /
    • 2014
  • PURPOSES : This study is to develop a automate road mapping system using ARASEO(Automated Road Analysis and Safety Evaluation TOol) for road management. METHODS : The road survey van named ARASEO(Automated Road Analysis and Safety Evaluation TOol) was used to generate highway drawings for Korea National Road number 37 automatically. In order to generate the highway drawings for purpose of road management, it is required to acquired the information for highway alignment, road width and road facilities such as safety barrier and road sign. Therefore the survey van acquired and analyzed the road width, median and guardrail data using rear side laser sensor of ARASEO and recognized the traffic control sign and chevron sign using foreside camera images. Also the highway alignment which is the basic information for highway drawing can be analyzed by acquisition the every 1m positional and attitude data using GPU and IMU sensor and developed algorithm. Finally, in this research the CAD based drawing software was developed to draw highway drawing using the analysis result from ARASEO. RESULTS : This study showed the comparison result of the surveyed road width and drawing data. To make the drawing of the road, we made the Autocad ARX program witch run in CAD menu interface. CONCLUSIONS : Using this program we can create the road center line, every 500m horizontal and vertical ground plan drawing automatically.

CT-Guided Percutaneous Transthoracic Needle Biopsy Using the Additional Laser Guidance System by a Pulmonologist with 2 Years of Experience in CT-Guided Percutaneous Transthoracic Needle Biopsy

  • Jeon, Min-Cheol;Kim, Ju Ock;Jung, Sung Soo;Park, Hee Sun;Lee, Jeong Eun;Moon, Jae Young;Chung, Chae Uk;Kang, Da Hyun;Park, Dong Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.4
    • /
    • pp.330-338
    • /
    • 2018
  • Background: We developed an additional laser guidance system to improve the efficacy and safety of conventional computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB), and we conducted this study to evaluate the efficacy and safety of our system. Methods: We retrospectively analyzed the medical records of 244 patients who underwent CT-guided PTNB using our additional laser guidance system from July 1, 2015, to January 20, 2016. Results: There were nine false-negative results among the 238 total cases. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of our system for diagnosing malignancy were 94.4% (152/161), 100% (77/77), 100% (152/152), 89.5% (77/86), and 96.2% (229/238), respectively. The results of univariate analysis showed that the risk factors for a false-negative result were male sex (p=0.029), a final diagnosis of malignancy (p=0.033), a lesion in the lower lobe (p=0.035), shorter distance from the skin to the target lesion (p=0.003), and shorter distance from the pleura to the target lesion (p=0.006). The overall complication rate was 30.5% (74/243). Pneumothorax, hemoptysis, and hemothorax occurred in 21.8% (53/243), 9.1% (22/243), and 1.6% (4/243) of cases, respectively. Conclusion: The additional laser guidance system might be a highly economical and efficient method to improve the diagnostic efficacy and safety of conventional CT-guided PTNB even if performed by inexperienced pulmonologists.

365 nm LED laser treatment on beagle for gingival whitening without gum dermabrasion (잇몸 박피술 없는 치은 미백을 위한 비글에서 365 nm LED 레이저 치료)

  • Lee, Sung-Ho;Kim, Ryun Kyung;Seo, Na-Ri;Lim, Ho-Kyung;Byun, Soo-Hwan;Lim, Young-Joon;Kim, Soung-Min;Lee, Jong-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.2
    • /
    • pp.117-122
    • /
    • 2016
  • Purpose: Gingival whitening is one of dental treatment purposes which is close to treating aesthetic disorders. Initial gingival whitening treatment was done by dermabrasion using a high power Diode Laser. However, this treatment method cannot be free from any infection or pain after the treatment. Therefore, we have decided to progress gingival whitening treatment using a low power LED laser. Materials and Methods: The laser was irradiated on pork meat then the safety of output power, temperature change and skin denaturalization was measured. Bison 365 nm LED laser was irradiated on oral mucosal pigment of a 15 - 20 kg beagle for 15 min for 1 - 2 weeks, one or two times each. Any pigment loss was checked through Hematoxyline-Eosin staining. Results: The melanin pigments at the area of 365 nm LED Laser irradiation were decreased. Conclusion: The 365 nm LED Laser proposed in this study is considered to compensate the bleaching effect achieved by either using Diode laser or surgical methods.

Extinguishment of n-heptane Pool Fire by Water Mist Containing Alkali Metal Agent (알칼리 금속염을 함유한 미분무수의 헵탄 Pool Fire 소화)

  • Park, Jae-Man;Shin, Chang-Sub
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.105-111
    • /
    • 2005
  • An experimental study is performed for extinguishing of n-heptane pool fire by water mist containing potassium acetate as a fire suppression additive. Water mist was generated by a single pressure nozzle in a small-scale chamber. The drop size distribution of water mist was measured using laser diffraction(Malvern particle sizer). The flame temperature, oxygen concentration and carbon monoxide concentration were measured. In case of using additives, the fire extinguishing time was shorter than that of pure water at a given discharge pressure and it was because the momentum of a water droplet containing additives was increased. And also dissociated metal atoms, potassium, were reacted as a scavenger of the major radical species OH, H which were generated for combustion process. Moreover, at a high pressure of 4MPa, the fire was extinguished through blowing effect as well as primary extinguishing mechanisms.