• Title/Summary/Keyword: Laser safety

Search Result 335, Processing Time 0.024 seconds

Study on Safety Control of The Laser Equipment (레이저 기기의 국제표준 평가 방법 및 안전 관리 방안 연구)

  • Park, Chan-keun;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.419-422
    • /
    • 2016
  • Recently, there are a lot of report about the safety accident in laser equipment for example laser pointer, laser level, laser distance meter, temperature measurement equipment and so on. But most of people doesn't care of the safety, and some of the people were damaged by laser in the retina and skin. So in this reaserch So in this thesis, research the safety control rules in global and domestic regulations and international standard IEC 60825-1. From the above research, develop the safety control rules to improve the consumer safety.

  • PDF

May Low Level Laser Therapy be the Candidate of First Choice for the Acute Stroke? (중풍 급성기에 있어서 레이저치료에 대한 최신지견 고찰 : 임상 논문을 중심으로)

  • Yang, Chang-Sop;Jang, In-Soo;Sun, Seung-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.31 no.3
    • /
    • pp.612-619
    • /
    • 2010
  • Background : Low level laser therapy may be an effective method to protect tissue damage in acute stroke. Recently, series of clinical studies on the basis of animal experiments report efficacy and safety of laser therapy at early stages of acute stroke. Laser promotes mitochondrial ATP synthesis to reduce cell death by ischemic infarction. Objectives : To report possibility of non-invasive laser therapy for acute stroke by reviewing literature about its effectiveness, safety and mechanism. Methods : We searched papers using PubMed and 'Web of Knowledge' of Thomson ISI, using the keywords "Laser Therapy, Low-Level" and "Stroke". Limitations were last 10 years of publications and only in English. Search range includes RCTs, clinical reports, reviews and animal experiments. Papers not matched with inclusion criteria were excluded. Results : A total 223 studies were found, 203 excluded during title and extract screening. After scanning 20 papers the final 2 serial RCTs were selected and analyzed. They reported that transcranial laser therapy led in neuroprotective effect for acute stroke patents. Clinical evaluation factors showed favorable trend and initial safety. Conclusions : Non-invasive laser secured safety of clinical application. It may be a favorable choice for the acute stage of stroke.

Study on the Role and Adoption of Medical Laser Safety Officer (MLSO) (의료레이저안전관리자의 역할과 국내 적용 방안 연구)

  • Heo, Jin-Wook;Park, Hyung-Jae;Lee, Young-Woo;Chon, Kwon-Soo;Cho, Woon-Kap;Kim, Yong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.115-120
    • /
    • 2012
  • According to the development of laser technology, applications of laser in medical area, and the resulting risks are increasing. To ensure the safe use of laser, it is necessary to assign a person who has the knowledge of laser safety as MLSO(medical laser safety officer). In many countries, the system of laser safety officer management is operating. MLSO has the responsibilities and duties of the operation of the laser safety program, training, and education. In this study, we analyzed the adoption of MLSO through the investigation of the MLSO management status in United States.

Efficacy and Safety of Laser Surgery and Transurethral Resection of the Prostate for Treating Benign Prostate Hyperplasia: a Network Meta-analysis

  • Wang, Li;Yu, Qiu-Yan;Liu, Yan;Zhu, Zhen-Li;Huang, Yuan-Wei;Li, Ke
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4281-4288
    • /
    • 2016
  • Background: Traditional meta-analyses or systematic reviews of randomized controlled trials (RCTs) have been used to compare laser surgeries and transurethral resection of the prostate (TURP) for benign prostate hyperplasia (BHP), but they cannot provide a hierarchy regarding efficacy and safety of treatment. Objective: We therefore performed a network meta-analysis (NMA) to compare and create hierarchies for efficacy and safety of TUPR and laser surgeries for BPH. Materials and Methods: We searched for reports of RCTs published up to April 25, 2015. After methodological quality assessment and data extraction, we performed an NMA to compare TURP and laser surgeries for BPH. Results: We ranked the treatments of TURP and laser surgeries for BPH. For IPSS at 6 months, holmium laser resection of the prostate (HoLRP) ranked the first-best and at 12 months, holmium laser enucleation of the prostate (HoLEP). For Qmax at 6 and 12 months, HoLEP ranked the first-best; for operative time it was TURP; for cathedral removal time, diode laser enucleation of the prostate (DiLEP) ranked the first-best. Conclusions: Although TURP is considered the gold standard for treating BPH, it is not better in terms of efficacy and safety compared with the laser surgery. Our NMA created hierarchies for the 9 types of surgery in terms of efficacy and safety, which should help clinicians choose the best approach for the individual patient.

A Study on Safety, Performance and Clinical effectiveness Test Guideline of Versatile Ophthalmic Laser System (다목적 안과용 레이저 시스템 안전성 성능평가 및 임상적 유효성평가 가이드라인 수립을 위한 연구)

  • Kim, You Rim;Yu, Woo Jin;Park, Ho Joon;Jang, Won Seuk
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.250-259
    • /
    • 2019
  • Ophthalmic Laser System is widely used in Selective Laser Trabeculoplasty of Open Angle Glaucoma and Ocular Hypertension. Versatile ophthalmic laser system is a medical device with technology that checks the condition of the treatment area by irradiating a continuous laser pulse on the treatment area, and monitoring the microbubble reaction caused by the temperature increase of the melanosome through the ultrasonic signal and the optical signal sensor. It performs selective laser treatment without damaging the photoreceptor by controlling the wavelength of the laser when microbubbles are detected. This study aims to suggest a guideline for evaluating safety, performance and clinical effectiveness of Versatile Ophthalmic Laser System in accordance with the growing technology. International Standards, Regulations, and Clinical Trial Protocols were investigated and analyzed for this study. As a result of this study, the safety, performance and clinical effectiveness test guideline for Versatile Ophthalmic Laser System were proposed. This guideline will ensure the safety and efficacy of Medical device, and furthermore it is expected to be able to promote the development of technology development by supporting a clinical trial plan.

A Study on Safety of 830 nm, 905 nm Laser Used for Laser Acupuncture Therapy (레이저침에 활용되는 830 nm, 905 nm 레이저의 안전성 연구)

  • Yoo, Pyung-Sik;Kim, Young-Sun;Moon, Young-Min;Lee, Suk-Hee;Jeong, Sung-Ho;Youn, Dae-Hwan;Choi, Chan-Hern;Na, Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.29 no.3
    • /
    • pp.441-452
    • /
    • 2012
  • Objectives : As the attempts to make good uses of laser acupuncture in korean medicine have been steadily carried on, to ensure the safety is needed to increase the use of laser acupuncture. The aim of this study was to examine the safety of using laser acupuncture therapy irradiated with 830 nm laser and 905 nm laser. Methods : Fifteen rats were randomly divided into three experimental groups - Intact ; no therapy group. LAT830 ; laser acupuncture therapy(830 nm) group at GB34 GB39. LAT905 ; laser acupuncture therapy(905 nm) group at GB34 GB39. During eight weeks of treatment, LAT830, LAT905 were treated 2 times weekly, frequency 20 Hz, intensity 20 mW. Test items were mortality, body weight, food consumptions, hematological values, blood chemical values, urinalysis values, absolute organ weights and relative organ weights. Results : Statistically significant differences were not found among 3 groups. The values measured in LAT830, LAT905 and Intact(no therapy) group have shown similar results and it indicated that LAT830, LAT905 had no abnormal influence on the reaction of living bodies. There was little difference on the liver weight of relative organ weight test between laser-treated groups(LAT830, LAT905) and Intact group. Conclusions : In conclusion, laser acupuncture therapies irradiated with 830 nm laser and 905 nm laser caused no abnormal reaction of living bodies. More studies are needed to further establish the safety of many other laser acupuncture therapies.

Laser Safety in Laryngeal Microsurgery Using $CO_2$Laser (후두미세수술에서 탄산가스 레이저를 이용한 레이저 수술의 안전성)

  • 이정구;정필상;정필섭
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.2
    • /
    • pp.159-164
    • /
    • 1998
  • The developmental and subsequent addition of laser technology to existing surgical techniques offered new and exciting Possibilities for improving traditional endoscopic operations and expanding the scope of the specialty of otolaryngology-head and neck surgery. Lasers were found to be Precise, but potentially dangerous, surgical instruments whose use was associated with certain distinct and unprecedented advantages, but also with many unique and potentially serious, and sometimes catastrophic complications. The Purpose of this study was to evaluate the of elation technique of $CO_2$laser, kinds of anesthesia, equipments of operating room, and education of medical staff. Four hundreds 4 cases of $CO_2$laser laryngeal microsurgery were reviewed for the safety of $CO_2$laser in laryngeal microsurgery. Vocal polyp (46,3%) was the most common pathology in our cases. The others were vocal nodule, Reinke`s edema, epiglottic cyst, laryngeal granuloma, laryngeal papilloma, intracordal cysts, laryngeal tuberculosis, laryngeal web, laryngotracheal stenosis, and laryngeal cancer. Following complete equipment controls, treatment area controls, maintenance, service and procedural controls, personel protective equipment, and warning signs, no complications were found in our cases. In conclusion, laryngeal microsurgery with $CO_2$laser could be done safely without complication if complete preoperative preparation and education of medical staff preceded.

  • PDF

Safe Use of Medical Lasers

  • Woo, Seung Hoon;Chung, Phil-Sang;Lee, Sang Joon
    • Medical Lasers
    • /
    • v.10 no.2
    • /
    • pp.68-75
    • /
    • 2021
  • Medical lasers have been widely used for various diseases. Despite the notable benefits, lasers could cause several complications such as skin burn, eye injury, airway fire, and so on. These accidents may occur not only with patients, users of the laser, or laser handlers but also to people passing in front of the laser treatment room. Although there is a risk associated with the laser, most of them can be prevented through good training, use of proper protection equipment, and ensuring the safe operation of the laser at all times. Due to the increasing use of lasers and the growing interest in their use, medical institutions should particularly emphasize the safe use of lasers and introduce systems for laser safety.

A Mechanic Structure Safety Evaluation Using Laser-Based Ultrasonics Application (기계 구조물의 안정성 평가를 위한 레이저 초음파법 적용)

  • 김재열;송경석;김창현;고명수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.174-179
    • /
    • 2003
  • Non-destructive test on the size and depth of cracks has been required for the safety evaluation of structures. Ultrasonic method based on laser techniques is one of the most popular non-destructive methods which overwhelm PZT based tests. In the present paper, ultrasonic was generated by high powered Q switching Nd:YAG pulse laser. Experiments were carried out using Fabry-Perot interferometer which was intensively discussed in the present study.

  • PDF

Laser Application and Nursing in the Field of Gynecology

  • Kim, Kyunghee
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.201-206
    • /
    • 2021
  • The recent development of new surgical techniques using lasers has increased the opportunities for open surgery involving minimal manipulation and faster and more accurate removal of lesions. The increasing use of laser technology requires nurses to play an extensive role. As assistants, nurses play an important role in maintaining the efficacy and safety of the laser device. In addition, they are also responsible for providing pre-and post-operative care to patients. Therefore, nurses should be aware of how to proceed with operative laser treatment for all surgical procedures and the steps for maintaining safety prior to, during, and after laser treatment. This review provides in-depth knowledge for nurses undertaking continuing education on lasers and patient care in the field of gynecology.