• Title/Summary/Keyword: Laser output

Search Result 774, Processing Time 0.022 seconds

Characterization of amplified spontaneous emission light source from an $Er^{3+}$/$Tm^{3+}$co-doped silica fiber ($Er^{3+}$$Tm^{3+}$이 복합 첨가된 실리카 광섬유의 ASE 광원에 대한 특성 평가)

  • Jeong, Hoon;Oh, K.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.96-97
    • /
    • 2000
  • Incoherent broadband optical sources have been applied in various areas such as a light source for optical device characterization, fiber-optic gyroscopes$^{(1)}$ , and spectrum sliced light source in wavelength division multiplexing (WDM) system$^{(2)}$ . To utilize the inherent low loss in silica optical fibers, various types of incoherent light sources are being developed. Among the light sources, the amplified spontaneous emission (ASE) from a rare earth doped fiber has benefits in temperature stability, high output power, low polarization dependence over semiconductor diodes$^{(3)}$ . Recently erbium doped fibers (EDF) have been intensively researched for ASE sources as well as optical amplifiers$^{(4)}$ . The spectrum of ASE from an EDF, however, is limited in the 1520~1560 nm range in conventional configurations. In this letter we described a new broadband ASE source which included both the conventional ASE band of Er$^{3+}$ ion, 1520nm~1560nm and ASE band from Tm$^{3+}$ ions that extends the bandwidth further. For the first time, to the best knowledge of authors, a fiber ASE source based on the energy transfer between Er$^{3+}$ and Tm$^{3+}$ ions in the range of 1460~1550 nm, has been demonstrated using a single 980nm pump laser diode. (omitted)omitted)

  • PDF

Regenerative Er-doped Fiber Amplifier System for High-repetition-rate Optical Pulses

  • Liu, Yan;Wu, Kan;Li, Nanxi;Lan, Lanling;Yoo, Seongwoo;Wu, Xuan;Shum, Perry Ping;Zeng, Shuguang;Tan, Xinyu
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.357-361
    • /
    • 2013
  • A regenerative Er-doped fiber amplifier system for a high-repetition-rate optical pulse train is investigated for the first time. A signal pulse train with a wavelength tuning range of 18 nm is produced by a passive mode-locked fiber laser based on a nonlinear polarization rotation technique. In order to realize the amplification, an optical delay-line is used to achieve time match between the pulses' interval and the period of pulse running through the regenerative amplifier. The 16 dB gain is obtained for an input pulse train with a launching power of -30.4 dBm, a center wavelength of 1563.4 nm and a repetition rate of 15.3 MHz. The output properties of signal pulses with different center wavelengths are also discussed. The pulse amplification is found to be different from the regenerative amplification system for CW signals.

Development of Ultra-precision Positioning Technology Using High-resolution Interpolation Algorithm (고체배 알고리즘을 이용한 초정밀 위치즉정기술 개발)

  • 이종혁;배준영;이상룡
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.117-124
    • /
    • 2004
  • Recently, nano-methodology is increasingly important as the ruler for measuring nano-technology, and we applied the linear encoder to nano-methodology. The quadrature output in the linear encoder has an effect on increasing the resolution in some techniques. Already, various interpolation techniques based on the quadrature signal have applied to the precision servo system. In this paper, we propose a new interpolation algorithm for ultra-precision positioning in the low speed with simulation by MATLAB SIMULINK. This method modified previous methods and was properly designed for some given control system. To verify, we first fulfilled the encoder signal test to find main parameters fer the signal transformation, then we proved the proposed interpolation algorithm by experiments, which show that the result of the interpolation algorithm corresponds with the measurement of the laser interferometer in 100 nm unit approximately. In addition, we can get more precise measurement by more accurate and noise-free signal. So we need to compensate imperfections in the encoder signal. After that, we will apply this algorithm to nano positioning system.

Two-dimensional Numerical Simulation of a Pulsed Heat Source High Temperature Inert Gas Plasma MHD Electrical Power Generator

  • Matsumoto, Masaharu;Murakami, Tomoyuki;Okuno, Yoshihiro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.589-596
    • /
    • 2008
  • Performance of a pulsed heat source high temperature inert gas plasma MHD electrical power generator, which can be one of the candidates of space-based laser-to-electrical power converter, is examined by a time dependent two dimensional numerical simulation. In the present MHD generator, the inert gas is assumed to be ideally heated to about $10^4K$ pulsed-likely within short time(${\sim}1{\mu}s$) in a stagnant energy input volume, and the energy of high temperature inert gas is converted to the electricity with the medium of pure inert gas plasma without seeding. The numerical simulation results show that an enthalpy extraction ratio(=electrical output energy/pulsed heat energy) of several tens of % can be achieved, which is the same level as the conventional seeded non-equilibrium plasma MHD generator. Although there still exist many phenomena to be clarified and many problems to be overcome in order to realize the system, the pulsed heat source high temperature inert gas MHD generator is surely worth examining in more detail.

  • PDF

Non-Invasive HbA1c Measurement Using Two-Wavelength Raman Scattering (2 파장 라만 산란을 이용한 비침습적 HbA1c 측정)

  • Yang, Jooran;Kim, Hyungpyo
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.305-310
    • /
    • 2019
  • The purpose of this study is to classify the concentration of HbA1c (glycosylated hemoglobin), which is an indicator in the management of accurate blood glucose level in diabetic patients, using a non-invasive optical property measurement method. To measure the optical properties of HbA1c, the optical source uses LEDs and laser diodes of 400 nm in the visible region and 1450 nm in the nearinfrared region using thermopile to detect the Raman scattering intensity. An HbA1c control solution was used. As a result, the optical properties of 5% (normal) and 9% (abnormal) HbA1c control solutions showed specificity in which the output values were reversed at 850 nm and 950 nm, respectively. This property was applied to distinguish between normal and abnormal values in diabetes. In addition, considering tissue penetration depths for non-invasive measurements, two wavelengths were determined to be effective in distinguishing the concentrations of HbA1c control solutions at 5%, 7%, and 9%.

A Deep Convolutional Neural Network Based 6-DOF Relocalization with Sensor Fusion System (센서 융합 시스템을 이용한 심층 컨벌루션 신경망 기반 6자유도 위치 재인식)

  • Jo, HyungGi;Cho, Hae Min;Lee, Seongwon;Kim, Euntai
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.2
    • /
    • pp.87-93
    • /
    • 2019
  • This paper presents a 6-DOF relocalization using a 3D laser scanner and a monocular camera. A relocalization problem in robotics is to estimate pose of sensor when a robot revisits the area. A deep convolutional neural network (CNN) is designed to regress 6-DOF sensor pose and trained using both RGB image and 3D point cloud information in end-to-end manner. We generate the new input that consists of RGB and range information. After training step, the relocalization system results in the pose of the sensor corresponding to each input when a new input is received. However, most of cases, mobile robot navigation system has successive sensor measurements. In order to improve the localization performance, the output of CNN is used for measurements of the particle filter that smooth the trajectory. We evaluate our relocalization method on real world datasets using a mobile robot platform.

Development of Hybrid Prototype Dual Load Cell Structure (하이브리드 프로토타입 듀얼 로드 셀 구조 개발)

  • Ham, Juh-Hyeok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.6
    • /
    • pp.373-380
    • /
    • 2020
  • We have developed the hybrid prototype load cell structures. These developed load cell structures may increase the reliability of the load sensing by deriving the load values through the double sensing method through the vertical maximum deflection and bending stress of the simple beams. For this purpose, the structure design was performed so that the load value, the deflection and stress value could be output to the same value through the optimal structure design. The structurally designed dimensions reaffirmed the accuracy of the design through the structural analysis program and the matching of the load value and the deflection value. Based on the designed structural dimension, the prototype form was constructed through laser cutting and production using hot rolled steel materials. The developed prototype load cell structure can be used as good educational material in various subjects such as material mechanics, steel structure design, measurement engineering, and mechatronics engineering. It is also believed that the measurement system ideas can inform the occurrence of errors in the event of a problem, and if a major accident caused by a sensing error is predicted, it will show good utilization to prevent accidents.

Fabrication of Hydrophobic Surfaces with Stereolithography (SLA을 이용한 소수성 표면 제작)

  • Hong, Sung-Ho
    • Tribology and Lubricants
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • This paper presents the experimental results of hydrophobic surfaces developed using a stereolithography-based additive-manufacturing technique. The additive manufacturing technique can be used to manufacture objects with complex geometries from computer-aided design data. Several additive manufacturing methods, such as selective laser sintering, fused deposition modeling, stereolithography apparatus (SLA), and inkjet-based system, have been developed. The SLA is a form of three-dimensional printing technology used to create prototypes, patterns, and production parts in successive layers through photochemical processes. Light causes chemical monomers and oligomers to cross-link together to form objects composed of polymers. Moreover, this method is economical for fabricating surfaces with high output resolution and quality. Here, we fabricate various surfaces using different shapes using an SLA. The surfaces with micro-patterns are fabricated for 10 cases, including the biomimetic surface. The fabricated surfaces with various micro-patterns are evaluated for hydrophobicity performance based on the static contact angle. The contact angle is measured three times for each case, and the averaged value is used. The results indicate that the arrangements in a staggered structure have a larger contact angle than those in a line when the same micro-pattern is applied. Moreover, the mimetic surfaces exhibit more hydrophobic characteristics than those of artificial micro-patterns.

Fiber Bragg Grating Temperature Sensor by the Wavelength Tuning Using the Temperature Dependence of VCSEL (빅셀(VCSEL)의 온도 의존성을 이용한 파장 가변 형 광섬유 격자 온도센서)

  • Lee, Chung-Ki;Kim, Sung-Moon
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.6
    • /
    • pp.241-246
    • /
    • 2018
  • In this paper, a low-cost optical temperature sensor is implemented, using a fiber Bragg grating (FBG) as the temperature probe and a low-cost VCSEL with temperature-dependent output wavelength as the light source. To analyze the wavelength of the reflected light from the FBG, an interrogation was applied using a method of referring to the internal temperature according to the output wavelength of the VCSEL. When the temperature of the VCSEL was adjusted from 14 to $52.2^{\circ}C$, the output wavelength varied from 1519.90 to 1524.25 nm. The degree of wavelength tuning according to temperature was $0.114nm/^{\circ}C$. The variable wavelength repeatability error according to temperature was ${\pm}0.003nm$, and the temperature measurement error was ${\pm}0.18^{\circ}C$. As a result of measuring the temperatures from 22.3 to $194.2^{\circ}C$, the value of the internal temperature change of the light source according to the applied temperature ${\Delta}T$ was $0.146^{\circ}C/{\Delta}T$, the change in reflected wavelength of the temperature probe according to applied temperature ${\Delta}T$ was measured at $16.64pm/^{\circ}C$. and the temperature measurement error of the sensor was ${\pm}1^{\circ}C$.

A Comparative Study of Initial Healing Process in White Rats after Gingivectomy using $CO_2$ Laser of different watts (($CO_2$)레이저를 이용한 백서의 치은절제술시 출력에 따른 초기 치유과정의 비교)

  • Cho, Kyoo-Sung;Hong, Sung-Jae;Choi, Seong-Ho;Chai, Jung-Kiu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.603-619
    • /
    • 1997
  • The use of laser in the treatment of soft tissue minimizes hemorrhage, provides better view of the operating field, and thereby minimizes operating time. Also, there will be far less post-operative swelling, pain and scar formation, and sterilizing effect are shown in some portions of the wound site. All these advantages of laser therapy contribute to its widespread use in the field of medicine and dentistry. Regarding such facts, we used CO2 laser of different watts in gingivectomy for white rats to compare initial healing process. For the control group, the least amount of output in performing gingivectomy(4watts) was offered, and for the experimental group, 6watts was given. Animals were sacrificed on the second, third days, 1 weeks, 2 weeks, and 3 weeks after operation, and their specimens were histologically analyzed. The following results were obtained: 1. Blood clot of small size was observed in both the control and experimental groups after two days, and no more thereafter. 2. In both the control and experimental groups, the inflammation zone size was the greatest after two days, and it decreased gradually to become almost invisble by the second week. The experimental group showed larger size of inflammation zone during second and third days: however, there was no difference after one week. 3. Granulation tissue in both the control and experimental groups showed gradual maturation with time, and by the second week, it was almost replaced by normal connective tissue. By the third week, complete healing pattern was observed. The experimental group showed larger granulation tissue than the control group until the third day, but there was no significant difference after one week. 4. In both the control and experimental groups, gingival epithelialization began on the second day. After one week, regeneration of rete peg and partial formation of junctional epithelium were observed: by the second week, keratinization of oral sulcular epithelium began, and it was completed by the third week.

  • PDF