• 제목/요약/키워드: Laser induced fluorescence

검색결과 248건 처리시간 0.028초

하이퍼 스펙트랄 반사광 및 형광 산란을 이용한 사과 품질 측정 (Apple Quality Measurement Using Hyperspectral Reflectance and Fluorescence Scattering)

  • 노현권
    • Journal of Biosystems Engineering
    • /
    • 제34권1호
    • /
    • pp.37-43
    • /
    • 2009
  • Hyperspectral reflectance and fluorescence scattering have been researched recently for measuring fruit post-harvest quality and condition. And they are promising for nondestructive detection of fruit quality. The objective of this research was to develop a model, which measure the quality of apple by using hyperspectral reflectance and fluorescence. A violet laser (408 nm) and a quartz tungsten halogen light were used as light sources for generating laser induced fluorescence and reflectance scattering in apples, respectively. The laser induced fluorescence and reflectance of 'Golden Delicious' apples were measured by using a hyperspectral imaging system. Fruit firmness, soluble solids and acid content were measured using standard destructive methods. Principal component analyses were performed to extract critical information from both hyperspectral reflectance and fluorescence data and this information was then related to fruit quality indexes. The fluorescence models had poorer predictions of the three quality indexes than the reflectance models. However, the prediction models of integrating fluorescence and reflectance performed consistently better than the individual models of either reflectance or fluorescence. The correlation coefficient for fruit firmness, soluble solid content, and tillable acidity from the integrated model was 0.86, 0.75, and 0.66 respectively. Also the standard errors were 6.97 N, 1.05%, and 0.07% respectively.

Excimer 형광법을 이용한 연료증기 농도측정법에 대한 연구 (Measurement of Fuel Vapor Concentration by Excimer Fluorescence Method)

  • 황승민
    • 한국환경과학회지
    • /
    • 제27권6호
    • /
    • pp.437-445
    • /
    • 2018
  • Laser induced-exciplex-fluorescence (EXCIPLEX) proposed by Melton is used to visualize fuel vapor in spray combustion. However, in the EXCIPLEX method based on TMPD/naphthalene system, the TMPD : naphthalene ratio is strictly restricted to 1 : 9. In addition, fluorescence intensity due to the vapor phase is extremely weak. To overcome these drawbacks, we propose a new laser-induced-excimer fluorescence (EXCIMER) method to visualize the liquid and vapor phases simultaneously. The spatial distributions of liquid and vapor in fuel spray suspended by ultrasonic waves are compared using the EXCIPLEX and EXCIMER methods. The correlation between fuel vapor concentration and fluorescence intensity is experimentally investigated by measuring the fluorescence intensity of saturated vapor formed over liquid fuel at a controlled temperature. These experimental results indicate that the EXCIMER method is effective for evaluating fuel vapor visualization in spray combustion. Furthermore, the quantitative distribution of fuel vapor concentration can be correctly estimated by the EXCIMER method.

The optical analysis of discharge lamp by Laser

  • Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.570-571
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1\rightarrow6^3P_2$) were larger than 404.8nm ($6^3S_1\rightarrow6^3P_1$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the L1F signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

형광, 산란광 동시 촬열법을 이용한 가솔린 분무의 거동에 관한 연구 (Visualization of Gasoline Sprays Via a Simultaneous Inaging of Fluorescence and Scattering Lights)

  • 원영호
    • 한국자동차공학회논문집
    • /
    • 제5권6호
    • /
    • pp.167-174
    • /
    • 1997
  • The penetration depth and the size distribution of the droplets of fuel sprays are important in the operation of spark-ignition MPI engines. A fluorescence/scattering image technique for droplet sizing was applied to measure th edroplet size distribution in non-evaporating gasoline sprays. The fluorescence and scattering lights were imaged simultaneously by the two-dimensional visualization system composed of a laser sheet, a doubling prism, optical filters, and a CCD camera. Quantitative droplet size distributions were extracted from evaluating the ratio of the two light densities. The mean droplet size measured by the fluorescence/scattering technique was compared with the result obtained by the enlarged photographs of droplets. The fluorescence/scattering image technique also gives the useful information of the characteristics of droplet impingement in a inclined wall.

  • PDF

레이저를 이용한 용액중의 미량 우라늄 분석 (Trace Analysis of Uranium in Aqueous Samples by Laser-induced Fluorescence Spectroscopy)

  • Jung, Kwang-Woo;Kim, Jeong-Moog;Kim, Cheol-Jung;Lee, Jong-Min
    • Nuclear Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.242-248
    • /
    • 1987
  • 레이저를 이용한 형광분석 방법과 형광의 세기를 증대시켜주는 'Fluran' 용액을 가함으로써 용액속에 존재하는 미량의 우라늄을 정착하고 신속하게 분석할 수 있는 새로운 장치를 개발하였다. 표준용액의 첨가 방법을 이용하여 시료의 조성 변화에 따른 형광의 방해효과를 보정할 수 있었고 5%이내의 정밀도를 갖는 0.1ppb의 측정 하한치를 얻을 수 있었다. 또한 여러 종류의 시료에 대하여 레이저를 이용한 형광분석 방법의 결과와 다른 측정 방법에 의한 결과를 상호 비교, 분석하였다.

  • PDF

N-propyl-N,N-dimethylethanolamine의 Phantom에서 Laser Induced Fluorescence의 스펙트라에 관한 연구 (A Study on Spectra of Laser Induced Flourescence in Phantom of N-propyl-N,N-dimethylethanolamine)

  • 김기준;이주호;이주엽;성완모
    • 한국응용과학기술학회지
    • /
    • 제32권2호
    • /
    • pp.330-338
    • /
    • 2015
  • N-propyl-N,N-dimethylethanolamine의 산란혼탁매질에서 형광, 산란과 응집의 영향은 파장 과 산란된 형광세기로 나타내는데, laser induced fluorescence(LIF) 분광학에 의한 분자특성으로 나타난다. 산란매질에서 광학적 효과는 광학적 파라미터들(${\mu}_s$, ${\mu}_a$, ${\mu}_t$)에 의해 표현되고 응집은 고-액상 분리 공정에서 중요하게 활용되고 있다. 따라서 입자가 서로 접근될 때 콜로이드 입자들의 상호작용을 LIF와 응집효과로 분석하였다. Monte Carlo simuation과 실험으로 레이저 광원에서 검출기까지 거리의 함수에 의해 농도가 묽어짐에 따라 산란세기가 기하급수적으로 감소함을 알 수 있었다. 이는 유지화학, 생의학, 레이저 의학, 의공학 분야적용에 LIF와 입자이동 현상은 아주 적합한 모델 연구에 큰 도움이 될 것이다.

Study on Argon Metastable and 4p State Neutral Atoms in Magnetized ICP and Helicon Plasmas Measured by Laser Induced Fluorescence and Plasma Emission

  • 서병훈;유신재;김정형;성대진;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.579-579
    • /
    • 2013
  • We study on Argon metastable and 4p state neutral atom density in magnetized ICP Helicon plasmas by Laser Induced Fluorescence and plasma emission. The results show that metastable density is too low at the center of chamber due to significant neutral depletion. Otherwise, 4p state is high at the center of chamber because electron density is very high. Power and pressure dependence of metastable and 4p state neutral atom have been spatially measured in the radial direction of cylindrical chamber.

  • PDF

LIF를 이용한 Hg-Ar 플라즈마 특성 평가 (Evaluation of Plasma Characteristics for Hg-Ar Using LIF)

  • 문종대
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.79-83
    • /
    • 2008
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely. This highlights the importance of measuring density distribution in plasma electric discharge mechanism study. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength. change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1{\to}6^3P_2$) were larger than 404.8nm ($6^3S_1{\to}6^3P_2$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

L-Aspartic Acid의 무질서하게 분포된 매질에서 파동전개와 변동에 관한 연구 (Studies on the Wave Propagation and Fluctuation in Randomly Ditribution Media of L-Aspartic Acid)

  • 김기준;이주엽
    • 한국응용과학기술학회지
    • /
    • 제29권1호
    • /
    • pp.122-128
    • /
    • 2012
  • L-arpartic acid의 산란혼탁매질에서 형광, 산란과 응집의 영향은 파장과 산란된 형광세기로 나타내는데, laser induced fluorescence(LIF) 분광학에 의한 분자특성으로 나타난다. 산란매질에서 광학적 효과는 광학적 파라미터들(${\mu}_s$, ${\mu}_a$, ${\mu}_t$)에 의해 표현되고 응집은 고-액상 분리공정에서 중요하게 활용되고 있다. 따라서 입자가 서로 접근될 때 콜로이드 입자들의 상호작용을 LIF와 응집효과로 분석하였다. 레이저 광원에서 검출기까지 농도의 함수에 의해 농도가 묽어짐에 따라 산란세기가 기하급수적으로 감소함을 알 수 있다. 이는 유지화학, 생의학 생성물, 레이저 의학, 의공학 분야적용에 LIF와 입자이동 현상은 아주 적합한 모델 연구에 큰 도움이 될 것이다.