• Title/Summary/Keyword: Laser imager

Search Result 23, Processing Time 0.022 seconds

Baseline Design and Performance Analysis of Laser Altimeter for Korean Lunar Orbiter

  • Lim, Hyung-Chul;Neumann, Gregory A.;Choi, Myeong-Hwan;Yu, Sung-Yeol;Bang, Seong-Cheol;Ka, Neung-Hyun;Park, Jong-Uk;Choi, Man-Soo;Park, Eunseo
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.211-219
    • /
    • 2016
  • Korea's lunar exploration project includes the launching of an orbiter, a lander (including a rover), and an experimental orbiter (referred to as a lunar pathfinder). Laser altimeters have played an important scientific role in lunar, planetary, and asteroid exploration missions since their first use in 1971 onboard the Apollo 15 mission to the Moon. In this study, a laser altimeter was proposed as a scientific instrument for the Korean lunar orbiter, which will be launched by 2020, to study the global topography of the surface of the Moon and its gravitational field and to support other payloads such as a terrain mapping camera or spectral imager. This study presents the baseline design and performance model for the proposed laser altimeter. Additionally, the study discusses the expected performance based on numerical simulation results. The simulation results indicate that the design of system parameters satisfies performance requirements with respect to detection probability and range error even under unfavorable conditions.

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.

Laser Doppler Analysis of the Effects of Electrocupuncture on Local Blood Flow on Skin Flap: A Case Report (국소 피부 이식 환자에 대한 전침치료가 이식 부위 말초혈류 변화에 미치는 영향의 레이저 도플러 분석: 증례 보고)

  • Kim, Kun-Hyung;Noh, Seung-Hee;Yang, Gi-Young;Kim, Jae-Kyu;Kim, Yu-Ri;Lee, Byung-Ryul
    • Journal of Acupuncture Research
    • /
    • v.29 no.4
    • /
    • pp.105-111
    • /
    • 2012
  • Objectives : An objective measurement for the effects of acupuncture therapy had been regarded as one of the important agendas in the research of acupuncture. This case report aimed to measure the changes of blood flow on the skin flap after one session of electroacupuncture treatment. Methods : A 27-year-old male patient was treated with ipsilateral or contralateral electroacupuncture on the $LI_{11}$, $LU_{10}$, $LI_{10}$, $TE_5$, $SI_3$ and Ex- $UE_9$(Palsa) in the arm with the skin flap on dorsal region of the hand. Changes of blood perfusion on the skin flap and opposite dorsum of hand were measured with laser Doppler blood perfusion imager(LDPI). Results : Immediate post-treatment relative changes of the blood perfusion on the skin flap and opposite hand after one session of ipsilateral electroacupuncture was 21% and 18% higher than values from pre-treatment assessment, respectively. On the contrary, when needled contralaterally, relative changes of the blood perfusion on the affected and unaffected hand was 7% lower and 22% higher than values from pre-treatment assessment, respectively. Mean differences of the blood perfusion between on the skin flap and on control hand remained similar after the ipsilateral acupuncture treatment but substantially increased(44.58 of perfusion units). Conclusions : Electroacupuncture may alter the local blood flow on the skin flap. More study is needed to investigate the effects of acupuncture on the blood flow and microcirculation on the skin tissue by well-designed clinical and experimental studies.

Simulation Based Design of Intelligent Surveillance Robot for Mobility (모바일화를 위한 지능형 경계로봇의 시뮬레이션기반 설계)

  • Hwang, Ki-Sang;Kim, Do-Hyun;Park, Kyu-Jin;Park, Sung-Ho;Kim, Sung-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.4
    • /
    • pp.340-346
    • /
    • 2008
  • An unmanned surveillance robot consists of a machine gun, a laser receiver, a thermal imager, a color CCD camera, and a laser illuminator. It has two axis control systems for elevation and azimuth. Because the current robot system is mounded at a fixed post to take care of surveillance tasks, it is necessary to modify such a surveillance robot to be installed on an UGV (Unmanned Ground Vehicle) system in order to watch blind areas. Thus, it is required to have a stabilization system to compensate the disturbance from the UGV. In this paper, a simulation based design scheme has been adopted to develop a mobile surveillance robot. The 3D CAD geometry model has first been produced by using Pro-Engineer. The required pan and tilt motor capacities have been analyzed using ADAMS inverse dynamics analysis. A target tracking and stabilization control algorithm of the mobile surveillance robot has been developed in order to compensate the motion of the vehicle which will experience the rough terrain. To test the performance of the stabilization control system of the robot, ADAMS/simulink co-simulations has been carried out.

Simulation based Design of a Mobile Surveillance Robot (모바일 경계로봇의 시뮬레이션 기반 설계)

  • Hwang, Ki-Sang;Park, Kyu-Jin;Kim, Do-Hyun;Kim, Sung-Soo;Park, Sung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1179-1184
    • /
    • 2007
  • An unmaned surveillance robot consists of rifle, laser receiver, thermal imager, color CCD camera, and laser illuminator. A human guard can be replaced with such a robot to take care dangerous surveillance tasks. Currently most of surveillance robots are mounded at a fixed post to take care of surveillance tasks. In order to watch blind areas, it is necessary to modify such a surveillance robot to become a mobile robot. In this paper, simulation based design procedure of mobile surveillance robot has been introduced. 3D CAD geometry model has been produced using Pro-Engineer. Required pen and tilt motor capacities have been analyzed using ADAMS inverse dynamics analysis. A target tracking and stabilization control algorithm of the mobile surveillance robot has been developed in order to stabilize the system from the motion of the vehicle which experiences the rough terrain. ADAMS-Matlab co-simulation has been also carried out to validate the proposed target tracking and stabilization algorithm.

  • PDF

Optical Design of an Image-space Telecentric Two-mirror System for Wide-field Line Imaging

  • Lee, Jong-Ung;Kim, Youngsoo;Kim, Seo Hyun;Kim, Yeonsoo;Kim, Hyunsook
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.344-350
    • /
    • 2017
  • We present a new design approach and an example design for an image-space telecentric two-mirror system that has a fast f-number and a wide-field line image. The initial design of the telecentric mirror system is a conventional axially symmetric system, consisting of a flat primary mirror with fourth-order aspheric deformation and an oblate ellipsoidal secondary mirror to correct spherical aberration, coma, and field curvature. Even though in the optimized design the primary mirror is tilted, to avoid ray obstruction by the secondary mirror, the image-space telecentric two-mirror system shows quite good imaging performance, for a line imager.

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

Can Daily-use Lipstick Make Lips More Fresh and Healthy\ulcorner - A New Lipstick Containing $\alpha$-Glucosyl-hesperidin Can Remove the Dull-color from Lips

  • Iwai, I.;Yamashita, T.;Ochiai, N.;Masuda, Y.;Hosokawa, K.;Kohno, Y.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09a
    • /
    • pp.162-177
    • /
    • 2003
  • It has been known that the color of skin reflects the blood flow within. In lips, the capillaries close to the skin surface are numerous; hence lips are redder than the rest of face. However, dermatological research on lips is not as advanced as research on facial or body skin, and little was known about the relationship between relatively dull-colored lips and skin blood flow. The physiological differences between colorful and dull-colored lips were studied by a two-dimensional laser Doppler blood flow analyzer, a spectrometer for the measurement of the degree of oxygen saturation, and a confocal microscope for observing inside lips non-invasively. Dull-colored lips and the corner of lips (dull-colored compared to the center) showed relatively poor blood flow and lower oxygenated hemoglobin. It was found that colorful lips (generally the young) had a blood flow that tended to run straight in parallel with the skin surface. This unique blood-capillary structure can express clear red blood. Those with dull-colored lips had lost this unique structure. Their blood ran perpendicularly from the deep of the skin and down back again into the deep part as like the blood circulation patterns of facial skin. Therefore, the lips of the latter group had fewer blood capillaries near skin surface in the lips than that of the colorful-lips group. A lipstick containing a-glucosyl-hesperidin, which is derived from certain citrus fruits and can enhance blood circulation, was applied for evaluating its effects. Blood flow was increased 30 min after the application. After two weeks of daily application, the lips' condition became noticeably less dull. These findings suggest that the decrease of blood flow in dull-colored lips is caused by the loss of the unique capillary structure and the use of the lipstick to increase blood flow can give a vivid color to lips.

  • PDF

Correlation between Subjective and Objective Measurement of Climacteric Women's Hot Flashes (갱년기 여성 안면홍조의 주관적 측정과 객관적 측정의 상관성)

  • Kim, Hyung-Jun;Leem, Kang-Hyun;Kim, Myoung-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.6
    • /
    • pp.765-774
    • /
    • 2010
  • Purpose: The purposes of this study were to explain the phenomena of hot flashes in climacteric women by using Mexameter, Skin Thermometer, Corneometer, and Laser Doppler Perfusion Imager (LDPI) objectively and to identify the interrelation between the subjective and objective measurements of hot flashes by comparing the two as reported in retrospective questionnaires. Methods: The participants were one hundred women (45-60 yr) who were not currently on hormone therapy, and had reached hot flash scores of 10 or higher. Hot flashes were measured in a temperature and humidity controlled room for 7 hr from 10 am to 5 pm. Hot flashes were measured subjectively and recorded via the Hot Flash Diary Report. When participants felt the hot flashes, they were measured objectively by Mexameter, Skin Thermometer, Corneometer, and LDPI. Results: The frequency of hot flashes in participants ranged from 1 to 7 times. When hot flashes occurred in participants, the erythema, skin temperature, skin hydration, and blood perfusion showed statistically significant changes in all measurements. But, the subjective and objective measurements of hot flashes showed only weak correlations. Conclusion: Results indicate a need for future research with subjective and objective measuring instruments chosen depending variations identified for the study.

A Study on the Availability of the On-Board Imager(OBI) and Cone-Beam CT(CBCT) in the Verification of Patient Set-up (온보드 영상장치(On-Board Imager) 및 콘빔CT(CBCT)를 이용한 환자 자세 검증의 유용성에 대한 연구)

  • Bak, Jino;Park, Sung-Ho;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.118-125
    • /
    • 2008
  • Purpose: On-line image guided radiation therapy(on-line IGRT) and(kV X-ray images or cone beam CT images) were obtained by an on-board imager(OBI) and cone beam CT(CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images(kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. Materials and Methods: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. Results: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within $0.06^{\circ}$ for rotation only, 1.8 mm for translation only, and 2.1 mm and $0.3^{\circ}$ for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within $0.03^{\circ}$ for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and $0.0^{\circ}$ for rotation, respectively, was possible. Conclusion: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.