• Title/Summary/Keyword: Laser Scanning

Search Result 1,398, Processing Time 0.028 seconds

Repairing of a Defective Metallic Line using Laser CVD Deposited Tungsten Film in TFT LCD (레이저 CVD 텅스텐막 증착을 통한 TFT LCD 불량배선 수리)

  • Kim, Sukoon-Koon;Son, Jeong-Seok;Lee, Gi-Sun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.10
    • /
    • pp.1114-1119
    • /
    • 2004
  • The photodepositioned tungsten film by laser CVD has been carried out the taping test with scotch tape over 10 times. As a result, it exhibited strong adhesion to the under-film such as ITO and SiNx patterned on the LCD substrate. However, it was seriously attacked by alkaline solution used for removing polyimide. And a thickness of laser CVD tungsten film had a close relation to a speed of laser scanning. Also we have improved the success rate of a laser CVD repair with making two pairs of contact hole structure and decreasing laser scanning speed.

An Experimental Study on the Effect of Laser to Bond Strength between Composite Resin and Bovine Teeth (우치치질에 레이저조사시 레진과의 결합강도에 관한 연구)

  • Cho, Ju-On;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.155-172
    • /
    • 1989
  • The purpose of this study is to measure the bonding strength at the enamel and dentin of extracted bovine incisors when they are irradiated by W Nd: YAG, EoQ Nd: YAG, and CW $CO_2$ laser, etched and then attached by composite resin. The laser-irradiated surface, the etched surface after the laser-irradiation and the interface of the treated surface and resin are observed by using scanning electron microscope. The NP Nd:YAG laser is used at the peam power of 207 KW. The EOQ Nd: YAG laser is used at the peak power of 1.15Mk. The CW $CO_2$ laser is used at the energy output of 5W and 10W in enamel; in dentin, at the energy output of 2W. The obtained results were as follows: 1. The shear bond strength of enamel decreased in the following order: EOQ Nd:YAG laser group, NP Nd:YAG laser group, CW $CO_2$ laser groups, unlased group. The unlased group showed a significant difference from EOQ Nd:YAG laser group (P<0.01), NP Nd:YAG laser group (P<0.05), but no significant difference from CW $CO_2$ laser group (P>0.05). 2. The shear bond strength of dentin decreased in the following order: CW $CO_2$ laser group, NP Nd:YAG laser group, unlased group, EOQ Nd:YAG laser group. The unlased group showed a significant difference from CW $CO_2$ laser group (P<0.01), but no significant difference from Nd:YAG laser groups (P>0.05). 3. The scanning electron microscope of enamel revealed irregular microcrack and pore at the surface in the NP Nd:YAG laser group and CW $CO_2$ laser group, but the crackless flat surface in the EOQ Nd:YAG laser group. 4. The scanning electron microscope of dentin revealed obstruction of in most of dentinal tubule and decrease of diameter. 5. The scanning electron microscope of the interface of resin and enamel revealed prominent penetration of resin tag in the EOQ Nd:YAG laser group.

  • PDF

STL mesh based laser scan planning system for complex freeform surfaces (STL 메쉬를 이용한 자유곡면의 레이저 측정경로 생성 연구)

  • 손석배;김승만;이관행
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.595-598
    • /
    • 2002
  • Laser scanners are getting used more and more in reverse engineering and inspection. For CNC-driven laser scanners, it is important to automate the scanning operations to improve the accuracy of capture point data and to reduce scanning time in industry. However, there are few research works on laser scan planning system. In addition, it is difficult to directly analyze multi-patched freeform models. In this paper, we propose an STL (Stereolithography) mesh based laser scan planning system for complex freeform surfaces. The scan planning system consists of three steps and it is assumed that the CAD model of the part exists. Firstly, the surface model is approximated into STL meshes. From the mesh model, normal vector of each node point is estimated. Second, scan directions and regions are determined through the region growing method. Also, scan paths are generated by calculating the minimum-bounding rectangle of points that can be scanned in each scan direction. Finally, the generated scan directions and paths are validated by checking optical constraints and the collision between the laser probe and the part to be scanned.

  • PDF

Laser Forming of Sheet Metal by Geometrical Information (기하학적 정보를 이용한 이중곡률 형상의 레이저 성형)

  • Kim, Ji-Tae;Na, Seok-Ju
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.91-93
    • /
    • 2005
  • Forming sheet metal by laser-induced thermal stresses (laser forming) has been extensively studied, and the research has focused on two-dimensional geometries using a multi-pass straight line scan. Recently there came out some useful studies or three-dimensional laser forming which is applied to doubly curved shapes. The task of 3D laser forming sheet metal is to determine a set of process parameters such as laser scanning paths, laser power and scanning speed that will make a given shape. New method for laser forming of a doubly curved surface by using geometrical information was proposed and verified by experiments. This method shows good performance in the sense of calculation time and accuracy compared to the inherent strain method.

  • PDF

Design of 3D Laser Radar Based on Laser Triangulation

  • Yang, Yang;Zhang, Yuchen;Wang, Yuehai;Liu, Danian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.5
    • /
    • pp.2414-2433
    • /
    • 2019
  • The aim of this paper is to design a 3D laser radar prototype based on laser triangulation. The mathematical model of distance sensitivity is deduced; a pixel-distance conversion formula is discussed and used to complete 3D scanning. The center position extraction algorithm of the spot is proposed, and the error of the linear laser, camera distortion and installation are corrected by using the proposed weighted average algorithm. Finally, the three-dimensional analytic computational algorithm is given to transform the measured distance into point cloud data. The experimental results show that this 3D laser radar can accomplish the 3D object scanning and the environment 3D reconstruction task. In addition, the experiment result proves that the product of the camera focal length and the baseline length is the key factor to influence measurement accuracy.

Development of Ftheta Lens for Laser Scanning Unit (Laser Scanning Unit용 FΘ 렌즈 개발)

  • Jeong, In-Sook;Ban, Min-Sung;Son, Kwang-Eun;Lee, Byoung-Bag
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.13-19
    • /
    • 2013
  • Ftheta Lens, whose image height is proportional to its field view angle, is one of the most important parts in Laser Scanning Unit(LSU). In this paper $f{\theta}$ lens design, mold production and modification method of lens design and mold are introduced. Lens design was carried out with Zemax and Special Toric surfaces were applied for lens surfaces to minimize distortion both in main and sub scanning directions. And a high precision machine with 1nm resolution was used to fabricate lens mold cores. After injection the lens was evaluated and the difference from design was examined. This difference was compensated by modifying lens design and new lens mold cores were made according to modified lens design to obtain the quality of original design.

Extracting Ground Information from Airborne Laser Scanning Data based on Mean Filtering Method (평균필터기반 항공레이저측량 자료의 지면정보 추출기법)

  • Choi, Yun-Woong;Lee, Geun-Sang;Chae, Hyo-Sok;Cho, Gi-Sung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.4
    • /
    • pp.61-70
    • /
    • 2005
  • Airborne laser scanning system needs preprocessing which removes some objects such as buildings from the raw DSM data to construct DEM in building area because the laser pulse can't penetrate into the buildings. This study applied the mean filtering method which has various size filter to the DSM data constructed by airborne laser scanning system and decided the optimal filter size as $39{\times}39$ by analyzing the standard deviation change ratio. Also, this study could get the ${\pm}0.065m$ standard error by comparing the optimal filtering DEM and DSM raw data of airborne laser scanning. Therefore, it could know that the mean filtering method, which is presented in this study, is very effective to extract DEM in the urban area which has a low relief.

  • PDF

Low-Complexity Handheld 3-D Scanner Using a Laser Pointer (단일 레이저 포인터를 이용한 저복잡도 휴대형 3D 스캐너)

  • Lee, Kyungme;Lee, Yeonkyung;Park, Doyoung;Yoo, Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.458-464
    • /
    • 2015
  • This paper proposes a portable 3-D scanning technique using a laser pointer. 3-D scanning is a process that acquires surface information from an 3-D object. There have been many studies on 3-D scanning. The methods of 3-D scanning are summarized into some methods based on multiple cameras, line lasers, and light pattern recognition. However, those methods has major disadvantages of their high cost and big size for portable appliances such as smartphones and digital cameras. In this paper, a 3-D scanning system using a low-cost and small-sized laser pointer are introduced to solve the problems. To do so, we propose a 3-D localization technique for a laser point. The proposed method consists of two main parts; one is a fast recognition of input images to obtain 2-D information of a point laser and the other is calibration based on the least-squares technique to calculate the 3-D information overall. To verified our method, we carry out experiments. It is proved that the proposed method provides 3-D surface information although the system is constructed by extremely low-cost parts such a chip laser pointer, compared to existing methods. Also, the method can be implemented in small-size; thus, it is enough to use in mobile devices such as smartphones.

A 3-D Tube Reconstruction based on Axis Alignment of Multiple Laser Scanning (배관측 정렬 방법을 이용한 다중레이저 스캐닝 기반의 3차원 배관복원)

  • Baek, Seung-Hae;Park, Soon-Yong;Kim, Seung-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.11
    • /
    • pp.1159-1167
    • /
    • 2011
  • A novel 3D tube scanning technique is proposed. The proposed tube scanning technique is developed for a special tube inspection module which consists of four line-lasers and one camera. Using the scanning module, we can reconstruct the 360 degree shapes of the inner surfaces of a cylindrical tube. From an image frame captured by the camera, we reconstruct a partial tube model based on four laser triangulations. Then by aligning such partial models with respect to a reference tube axis, a complete 3D shape of the tube is reconstructed. The tube axis in each reconstructed frame is aligned with a 3D Euclidean transformation to the reference axis. Several experiments show that the proposed method can align multiple tube axes very accurately and reconstruct 3D shapes of a tube with very low shape distortion.

FUSION OF LASER SCANNING DATA, DIGITAL MAPS, AERIAL PHOTOGRAPHS AND SATELLITE IMAGES FOR BUILDING MODELLING

  • Han, Seung-Hee;Bae, Yeon-Soung;Kim, Hong-Jin;Bae, Sang-Ho
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.899-902
    • /
    • 2006
  • For a quick and accurate 3D modelling of a building, laser scanning data, digital maps, aerial photographs and satellite images should be fusioned. Moreover, library establishment according to a standard structure of a building and effective texturing method are required in order to determine the structure of a building. In this study, we made a standard library by categorizing Korean village forms and presented a model that can predict a structure of a building from a shape of the roof on an aerial photo image. We made an ortho image using the high-definition digital image and considerable amount of ground scanning point cloud and mapped this image. These methods enabled a more quick and accurate building modelling.

  • PDF