• Title/Summary/Keyword: Laser Scanner

Search Result 543, Processing Time 0.028 seconds

Extraction of Coast Topographic Information Using Mobile Laser Scanning and Airborne LiDAR (지상레이저스캐너와 항공라이다를 이용한 해안 지형정보 추출)

  • Lee, In-Su;Tcha, Dek-Kee;Kim, Su-Jeong
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2009.04a
    • /
    • pp.115-117
    • /
    • 2009
  • Terrestrial Laser Scanner and Airborne Laser Scanning is one of the state of art surveying equipments. So This study deals with the combined use of mobile TLS(Terrestrial Laser Scanner) with ALS(Airborne Laser Scanning) to extract shoreline's topography information. These two systems have their own pros and cons. Mobile TLS can capture the facades of a low story building along the shoreline fast and quickly. Meanwhile, Due to viewpoint restrictions of ALS data collection, the amount of detail, which is available for the building facades is very limited. Therefore, it is recommended that the co-registration and geo-referencing methods of both two should be developed and the application of both system for shoreline mapping also should be investigated.

  • PDF

Estimation of People Tracking by Kalman Filter based Observations from Laser Range Sensor (레이저스케너 센서기반의 칼만필터 관측을 이용한 사람이동예측)

  • Jin, Taeseok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.3
    • /
    • pp.265-272
    • /
    • 2019
  • For tracking a varying number of people using laser range finder, it is important to deal with appearance/disappearance of people due to various causes including occlusions. We propose a method for tracking people with automatic initialization by integrating observations from laser range finder. In our method, the problem of estimating 2D positions and orientations of multiple people's walking direction is formulated based on a mixture kalman filter. Proposal distributions of a kalman filter are constructed by using a mixture model that incorporates information from a laser range scanner. Our experimental results demonstrate the effectiveness and robustness of our method.

Development of Digital 3D Real Object Duplication System and Process Technology (디지털 3차원 실물복제기 시스템 및 공정기술 개발)

  • Kim D.S.;An Y.J.;Lee W.H.;Choi B.O.;Chang M.H.;Baek Y.J.;Choi K.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.732-737
    • /
    • 2005
  • Distal 3D Real Object Duplication System(RODS) consists of 3D Scanner and Solid Freeform Fabrication System(SFFS). It is a device to make three-dimensional objects directly from the drawing or the scanning data. In this research, we developed an office type SFFS based on Three Dimensional Printing Process and a industrial SFFS using Dual Laser. An office type SFFS applied sliding mode control with sliding perturbation observer(SMCSPO) algorithm for control of this system. And we measured process variables about droplet diameter measurement and powder bed formation etc. through experiments. Also, in order to develop more elaborate and speedy system for large objects than existing SLS process, this study applies a new Selective Multi-Laser Sintering(SMLS) process and 3-axis dynamic Focusing Scanner for scanning large area instead of the existing $f\theta$ lens. In this process, the temperature has a great influence on sintering of the polymer. Also the laser parameters are considered like that laser beam power, scan speed, scan spacing. Now, this study is in progress to eveluate the effect of experimental parameters on the sintering process.

  • PDF

Study on friction characteristics according to lubrication condition of metal surface by laser dotted line pattern processing (레이저 점선 패턴가공된 금속표면의 윤활조건에 따른 마찰특성에 관한 연구)

  • Chung, Woo-Young;Kim, Sang-Ho;Han, Hyung-Wook;Min, Joon-Won;Jeung, Won-Yong;Rhee, Meung-Ho
    • Laser Solutions
    • /
    • v.13 no.2
    • /
    • pp.1-5
    • /
    • 2010
  • A high speed laser texturing method that relies on laser scanner conditions, to form pattern shapes with micro-narrow surface detail such as dotted line features is demonstrated and analyzed. For example, this method may be used to piston ring and gear part for automotive. Data on friction characteristics of two laser patterns employed for STD61 steel will be shown. Comparison of pattern depths obtained by repetition overlapping process with laser scanner to the results on friction coefficient will be provide. It will be shown that friction characteristic in dotted line patterns can significantly depend upon interaction with the lubrication and laser pattern conditions. Laser pattern processing into a shallow depth provides only slight improvement in friction, while work into a deep shape indicates a significant improvement.

  • PDF

A Study on Intelligent Robot Bin-Picking System with CCD Camera and Laser Sensor (CCD카메라와 레이저 센서를 조합한 지능형 로봇 빈-피킹에 관한 연구)

  • Kim, Jin-Dae;Lee, Jeh-Won;Shin, Chan-Bai
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.11 s.188
    • /
    • pp.58-67
    • /
    • 2006
  • Due to the variety of signal processing and complicated mathematical analysis, it is not easy to accomplish 3D bin-picking with non-contact sensor. To solve this difficulties the reliable signal processing algorithm and a good sensing device has been recommended. In this research, 3D laser scanner and CCD camera is applied as a sensing device respectively. With these sensor we develop a two-step bin-picking method and reliable algorithm for the recognition of 3D bin object. In the proposed bin-picking, the problem is reduced to 2D intial recognition with CCD camera at first, and then 3D pose detection with a laser scanner. To get a good movement in the robot base frame, the hand eye calibration between robot's end effector and sensing device should be also carried out. In this paper, we examine auto-calibration technique in the sensor calibration step. A new thinning algorithm and constrained hough transform is also studied for the robustness in the real environment usage. From the experimental results, we could see the robust bin-picking operation under the non-aligned 3D hole object.

Accuracy of Bolton analysis measured in laser scanned digital models compared with plaster models (gold standard) and cone-beam computer tomography images

  • Kim, Jooseong;Lagravere, Manuel O.
    • The korean journal of orthodontics
    • /
    • v.46 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Objective: The aim of this study was to compare the accuracy of Bolton analysis obtained from digital models scanned with the Ortho Insight three-dimensional (3D) laser scanner system to those obtained from cone-beam computed tomography (CBCT) images and traditional plaster models. Methods: CBCT scans and plaster models were obtained from 50 patients. Plaster models were scanned using the Ortho Insight 3D laser scanner; Bolton ratios were calculated with its software. CBCT scans were imported and analyzed using AVIZO software. Plaster models were measured with a digital caliper. Data were analyzed with descriptive statistics and the intraclass correlation coefficient (ICC). Results: Anterior and overall Bolton ratios obtained by the three different modalities exhibited excellent agreement (> 0.970). The mean differences between the scanned digital models and physical models and between the CBCT images and scanned digital models for overall Bolton ratios were $0.41{\pm}0.305%$ and $0.45{\pm}0.456%$, respectively; for anterior Bolton ratios, $0.59{\pm}0.520%$ and $1.01{\pm}0.780%$, respectively. ICC results showed that intraexaminer error reliability was generally excellent (> 0.858 for all three diagnostic modalities), with < 1.45% discrepancy in the Bolton analysis. Conclusions: Laser scanned digital models are highly accurate compared to physical models and CBCT scans for assessing the spatial relationships of dental arches for orthodontic diagnosis.

Development of Smart Tape Attachment Robot in the Cold Rolled Coil with 3D Non-Contact Recognition (3D 비접촉 인식을 이용한 냉연코일 테이프부착 로봇 개발)

  • Shin, Chan-Bai;Kim, Jin-Dae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.11
    • /
    • pp.1122-1129
    • /
    • 2009
  • Recently taping robot with smart recognition function have been studied in the coil manufacturing field. Due to the difficulty of 3D surface processing from the complicated working environment, it is not easy to accomplish smart tape attachment motion with non-contact sensor. To solve these problems the applicable surface recognition algorithm and a flexible sensing device has been recommended. In this research, the fusion method between 1D displacement and 3D laser scanner is applied for robust tape attachment about cold rolled coil. With these sensors we develop a two-step exploration and the smart algorithm for the awareness of non-aligned coil's information. In the proposed robot system for tape attachment, the problem is reduced to coil's radius searching with laser displacement sensor at first, and then position and orientation detection with 3D laser scanner. To get the movement at the robot's base frame, the hand-eye compensation between robot's end effector and sensing device should be also carried out respectively. In this paper, we examine the auto-coordinate transformation method in the calibration step for the real environment usage. From the experimental results, it was shown that the taping motion of robot had a robust under the non-aligned cold rolled coil.

Atomic Force Microscope for Standard Length Metrology (직교 스캐너와 레이저 간섭계를 사용한 교정용 원자현미경)

  • Lee, Dong-Yeon;Kim, Dong-Min;Gweon, Dae-Gab
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.12 s.255
    • /
    • pp.1611-1617
    • /
    • 2006
  • A compact and two-dimensional atomic force microscope (AFM) using an orthogonal sample scanner, a calibrated homodyne laser interferometer and a commercial AFM head was developed for use in the nano-metrology field. The x and y position of the sample with respect to the tip are acquired by using the laser interferometer in the open-loop state, when each z data point of the AFM head is taken. The sample scanner which has a motion amplifying mechanism was designed to move a sample up to $100{\times}100{\mu}m^2$ in orthogonal way, which means less crosstalk between axes. Moreover, the rotational errors between axes are measured to ensure the accuracy of the calibrated AFM within the full scanning range. The conventional homodyne laser interferometer was used to measure the x and y displacements of the sample and compensated via an X-ray interferometer to reduce the nonlinearity of the optical interferometer. The repeatability of the calibrated AFM was measured to sub-nm within a few hundred nm scanning range.

Analysis of 3D Laser Scanner Input Performance in Structual Safety Diagnosis (구조안전진단에서의 3D 레이저 스캐너 투입 성과 분석)

  • Seong, Do-Yun;Baek, In-Soo;Kim, Jea-Jun;Ham, Nam-Hyuk
    • Journal of KIBIM
    • /
    • v.11 no.3
    • /
    • pp.34-44
    • /
    • 2021
  • This study quantitatively analyzes the work performance of the structural safety diagnosis team that diagnoses pipe racks. To this end, a method for evaluating the performance of the structural safety diagnosis team using the queuing model was proposed. For verification, the case of applying the existing method and the method of introducing a 3D laser scanner for one site was used. The period, number of people, and initial investment cost of each project were collected through interviews with case project experts. As a result of analyzing the performance of the structural safety diagnosis team using the queuing model, it was possible to confirm the probability of delay in the work of each project and the amount of delayed work. Through this, the cost (standby cost) when the project was delayed was analyzed. Finally, economic analysis was conducted in consideration of the waiting cost, labor cost, and initial investment cost. The results of this study can be used to decide whether to introduce 3D laser scanners.

Investigation of Distance Measurement Performance Using Waveform Clouds-Based Terrestrial Laser Scanner (Waveform 방식의 지상라이다 거리측정 성능 실험)

  • Lee, In-Su;Kim, Hyung-Moo;Cha, Deuk-Gi;Lee, Dong-Rak
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.45-47
    • /
    • 2010
  • Terrestrial Laser Scanner is widely useful in the cultural heritage documentation, acquisition of three-dimensional spatial information in the field of civil engineering and construction, and the safety monitoring for the inaccessible sites such as a few bridges and landslides. This study deals with the investigation of distance measurement and the performances assesment with waveform clouds-based(TLS).

  • PDF