• 제목/요약/키워드: Laser Heat Treatment

검색결과 231건 처리시간 0.03초

The Effectiveness of 448-kHz Capacitive Resistive Monopolar Radiofrequency for Subcutaneous Fat Reduction in a Porcine Model

  • Kwon, Tae-Rin;Lee, Sung-Eun;Kim, Jong Hwan;Jeon, Yong Jae;Jang, You Na;Yoo, Kwang Ho;Kim, Beom Joon
    • Medical Lasers
    • /
    • 제8권2호
    • /
    • pp.64-73
    • /
    • 2019
  • Background and Objectives The effectiveness of many physiotherapy modalities in reducing subcutaneous fat has been investigated in numerous previous studies. However, to the best of our knowledge, there have been no attempts to determine the effectiveness of physiotherapy modalities in body contouring. The present report determined the effect of 448-kHz capacitive resistive monopolar radiofrequency (CRMRF) in a porcine model. Materials and Methods This study investigated the effect of selective destruction of the subcutaneous fat layer in abdominal fat tissue using CRMRF. The effects of two types of CRMRF (capacitive electric transfer (CET) and resistive electric transfer (RET)) treatment were evaluated using regular digital photography in addition to thermal imaging evaluation, ultrasound measurement, hematological evaluation, and histologic analyses (H&E (hematoxylin and eosin), Oil red O, and immunohistochemistry staining). Results Preclinical evaluation was performed to obtain the data for comparison of the safety and efficacy of the subcutaneous fat reduction after applying CRMRF using CET and RET. After treatment, the thermal transmission was effective, and a 42-47℃ temperature change was observed in the fat layer while an approximately temperature of 42℃ was confirmed on the skin surface. Moreover, after the application of both types of CRMRF treatment, fibrotic septa were observed in the adipose tissue induced by heat at the treatment sites. TUNEL staining was also performed to confirm the process of apoptosis in the adipocytes. Conclusion These results suggest that both CET and RET for CRMRF treatment are safe and effective for subcutaneous fat reduction in a porcine model.

구창의 문헌연구 (A literal study on the Gu-Chang)

  • 정한솔;박종훈;육상원;이광규
    • 동의생리병리학회지
    • /
    • 제16권1호
    • /
    • pp.32-44
    • /
    • 2002
  • Gu-Chang is a disorder characterized by recurring ulcers confined to the oral mucosa. Despite much clinical and research attention, the causes remain poorly understood. In this paper, we will compare Gu-Chang with Recurrent Aphthous Stomatitis(RAS) in order to know what is the similiarity between Gu-Chang and RAS. So we will arrange various oriental and western medical literatures which are important. As a result of arrangement of the causes, symptoms and therapys of Gu-Chang, we can conclude through the studies as follows. 1. The etiologies of Gu-chang are following. In the Sthenia syndrome, there are evil heat of external factor, heat of heart and spleen, insomnia, heat of upper warmer, stress and diet, heat of lung and heart, excessive heat of upper warmer, inappropriate food intake, heat conveyance of organ, heat of stomach merdian, moistured heat of spleen and stomach and stasis of liver energy. In the Asthenia syndrome, there are deficiency of stomach energy, deficiency of upper warmer leading to heat, deficiency of middle warmer leading to cold, deficiency of lower warmer leading to heat, deficiency of middle energy, deficiency of blood, decreased fire and deficiency of soil, yin fire of lower warmer, deficiency of heart yin, deficiency of spleen yin and deficiency of qi and blood. 2. In western medicine the causes of RAS is presumed as local, microbial, systemic, nutritional, genetic, immunologic factors. 3. Once Gu-chang is compared with RAS, in the deficiency of yin leading to hyperactivity of fire, deficiency of yin leading to floating of fire and stasis of liver energy, recurring of Gu-chang is similar to RAS. Although recurring of Gu-chang due to tripple warmer of excessive fire has no recurrance, since there are the degree of Pain, site of lesion, dysphagia etc, it is similar to major RAS. It is may be believed that Sthenia Gu-chang is similar to major RAS, shape of recurring, site of lesion, degrree of Pain and white color of Asthenia Gu-chang are similar to minor RAS, but there is no similarity concerning herpes RAS in the literatures that describe the symptoms. 4. Generally, the treatment of Gu-chang is divided into Asthenia and Sthenia Syndrome. The method of cure to Sthenia syndrome is heat cleaning and purge fire, Asthenia syndrome is nourish yin to lower and adverse rising energy and strength the middle warmer and benefit vital energy. 5. Following is the medication for Sthenia syndrome. Heat of heart and spleen is Do Jok San, Yang Gyek San, Juk Yup Suk Go Tang, evil heat of external factor is Yang Gyek San Ga Gam, Stasis of liver energy is Chong Wi Fae Dok Yum, moistured heat of spleen and stomach is Chong Gi Sam Syep Tang. The medication for Asthenia Syndrome is following. Deficiency of upper warmer leading to heat is Bo Jung Ik Gi Tang, deficiency of middle warmer leading to cold is Bu Ja Lee Jung Tang, deficiency of lower warmer leading to heat is Yuk Mi Ji Hwang Tang, deficiency of yin leading to hyperactivity of fire is Ji Baek Ji Hwang Hwan, deficiency of yin leading to floating of fire is Lee Jung Tang Ga Bu Ja Medicine for external use were Yang Suk San, Boo Wyen San, Rok Po San, Yoo Hwa San ate. 6. In western medicine, there is no specific treatment for RAS, and management strategies depend on dinical presentation and symptoms and includes antibiotics, oral rinses, glucocorticoids, immunomodulatory drugs, vitamines, analgesics, laser and antiviral agents.

프로테옴 분석법에 의한 벼 줄기에서 발현하는 고온 스트레스 관련 단백질 및 저분자량 Heat Shock Protein의 분리 동정 (Identification of Heat Stress-related Proteins and Low Molecular Weight HSP Expressed in Stem Tissues of Rice Plants by Proteomic Analysis)

  • 이동기;김경희;김용구;이기원;이상훈;이병현
    • 한국초지조사료학회지
    • /
    • 제31권2호
    • /
    • pp.99-106
    • /
    • 2011
  • 프로테오믹스 기법을 이용하여 벼 고온 스트레스 관련 단백질을 분리 동정하기 위하여 $42^{\circ}C$에서 고온처리한 벼의 줄기로부터 단백질을 분리하였다. 분리한 단백질로부터 Rubisco 단백질을 제거하기 위해 15% PEG fractionation을 실시한 후 상등액 분획의 단백질을 이차원전기 영동한 후, CBB 염색을 통해 차별적 발현을 보이는 단백질을 분석하였다. 총 46개의 단백질 spot이 발현양에 변화를 보였으며, 그 중 24개의 단백질이 고온 스트레스에 의해 발현이 증가되었으며, 22개의 단백질이 감소하는 발현 양상을 나타내었다. 이들 단백질을 MALDI-TOF MS와 database를 통해 동정한 결과 에너지 대사관련 단백질, 산화 환원 관련 단백질 및 저분자량 small HSP 등, 10개의 단백질이 동정되었다. 이들 동정된 단백질들은 식물의 고온 스트레스에 대한 적응기작을 이해하는데 중요한 단서를 제공할 것이며, 특히 미토콘드리아 small HSP는 프로테옴 분석법에 의해 최초로 동정되었으며, 금후 내하고성 목초 분자육종에 활용될 수 있는 좋은 유전자로 판단된다.

Effects of Low-Dose Aspirin Therapy on Thermoregulation in Firefighters

  • McEntire, Serina J.;Reis, Steven E.;Suman, Oscar E.;Hostler, David
    • Safety and Health at Work
    • /
    • 제6권3호
    • /
    • pp.256-262
    • /
    • 2015
  • Background: Heart attack is the most common cause of line-of-duty death in the fire service. Daily aspirin therapy is a preventative measure used to reduce the morbidity of heart attacks but may decrease the ability to dissipate heat by reducing skin blood flow. Methods: In this double-blind, placebo-controlled, crossover study, firefighters were randomized to receive 14 days of therapy (81-mg aspirin or placebo) before performing treadmill exercise in thermal-protective clothing in a hot room [$38.8{\pm}2.1^{\circ}C$, $24.9{\pm}9.1%$ relative humidity (RH)]. Three weeks without therapy was provided before crossing to the other arm. Firefighters completed a baseline skin blood-flow assessment via laser Doppler flowmetry; skin was heated to $44^{\circ}C$ to achieve maximal cutaneous vasodilation. Skin blood flow was measured before and after exercise in a hot room, and at 0 minutes, 10 minutes, 20 minutes, and 30 minutes of recovery under temperature conditions ($25.3{\pm}1.2^{\circ}C$, $40.3{\pm}13.7%\;RH$). Platelet clotting time was assessed before drug administration, and before and after exercise. Results: Fifteen firefighters completed the study. Aspirin increased clotting time before and after exercise compared with placebo (p = 0.003). There were no differences in absolute skin blood flow between groups (p = 0.35). Following exercise, cutaneous vascular conductance (CVC) was $85{\pm}42%$ of maximum in the aspirin and $76{\pm}37%$ in the placebo groups. The percentage of maximal CVC did not differ by treatment before or after recovery. Neither maximal core body temperature nor heart rate responses to exercise differed between trials. Conclusion: There were no differences in skin blood flow during uncompensable heat stress following exercise after aspirin or placebo therapy.

Application of 630-nm and 850-nm Light-emitting Diodes and Microcurrent to Accelerate Collagen and Elastin Deposition in Porcine Skin

  • Kwon, Tae-Rin;Moon, Dong Wook;Kim, Jungwook;Kim, Hyoung Jun;Lee, Seong Jae;Han, Yunhee;Dan, Hee Won;Chi, Sang Hoon;Seong, Hwan Mo;Kim, Hee Jung;Lim, Guei-Sam;Lee, Jungkwan
    • Medical Lasers
    • /
    • 제10권2호
    • /
    • pp.96-105
    • /
    • 2021
  • Background and Objectives Skin aging is reportedly associated with regulation in collagen and elastin synthesis. This study investigated the potential of combining light-emitting diode (LED) treatments using a 630-nm and 850-nm LED with simultaneous microcurrent application. Materials and Methods The dorsal skin of female pigs was treated with a home-use device. We examined the treatment effects using photography, thermocamera, microscopic pathology, and histological examination to determine the mechanism of action, efficacy, and safety of the procedure. A histological observation was performed using hematoxylin and eosin, Masson's trichrome, Victoria blue, and immunohistochemical staining. We also used the Sircol soluble collagen and elastin assay kit to measure the amounts of collagen and elastin in the porcine back skin tissue after 2 and 6 weeks. Results Evaluation by visual inspection and devices showed no skin damage or heat-induced injury at the treatment site. Histological staining revealed that accurate treatment of the targeted dermis layer effectively enhanced collagen and elastin deposition. Collagen type I, a protein defined by immunohistochemical staining, was overexpressed in the early stages of weeks 2 and 6. Combined therapy findings showed the superior capability of the 630-nm and 850-nm LED procedures to induce collagen; in contrast, elastin induction was more pronounced after microcurrent treatments. Conclusion The home-use LED device, comprising a combination of 630-nm and 850-nm LEDs and microcurrent, is safe and can be used as an adjunctive treatment for self-administered facial rejuvenation.

INTERGRANULAR CORROSION-RESISTANT STAINLESS STEEL BY GRAIN BOUNDARY ENGINEERING

  • Hiroyuki Kokawa;Masayuki Shimada;Wang, Zhan-Jie;Yutaka S. Sato
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.250-254
    • /
    • 2002
  • Intergranular corrosion of austenitic stainless steels is a conventional and momentous problem during welding and high temperature use. One of the major reasons for such intergranular corrosion is so-called sensitization, i.e., chromium depletion due to chromium carbide precipitation at grain boundaries. Conventional methods for preventing sensitization of austenitic stainless steels include reduction of carbon content in the material, stabilization of carbon atoms as non-chromium carbides by the addition of titanium, niobium or zirconium, local solution-heat-treatment by laser beam, etc. These methods, however, are not without drawbacks. Recent grain boundary structure studies have demonstrated that grain boundary phenomena strongly depend on the crystallographic nature and atomic structure of the grain boundary, and that grain boundaries with coincidence site lattices are immune to intergranular corrosion. The concept of "grain boundary design and control", which involves a desirable grain boundary character distribution, has been developed as grain boundary engineering. The feasibility of grain boundary engineering has been demonstrated mainly by thermomechanical treatments. In the present study, a thermomechanical treatment was tried to improve the resistance to the sensitization by grain boundary engineering. A type 304 austenitic stainless steel was pre-strained and heat-treated, and then sensitized, varying the parameters (pre-strain, temperature, time, etc.) during the thermomechanical treatment. The grain boundary character distribution was examined by orientation imaging microscopy. The intergranular corrosion resistance was evaluated by electrochemical potentiokinetic reactivation and ferric sulfate-sulfuric acid tests. The sensitivity to intergranular corrosion was reduced by the thermomechanical treatment and indicated a minimum at a small roll-reduction. The frequency of coincidence-site-lattice boundaries indicated a maximum at a small strain. The ferric sulfate-sulfuric acid test showed much smaller corrosion rate in the thermomechanically-treated specimen than in the base material. An excellent intergranular corrosion resistance was obtained by a small strain annealing at a relatively low temperature for long time. The optimum parameters created a uniform distribution of a high frequency of coincidence site lattice boundaries in the specimen where corrosive random boundaries were isolated. The results suggest that the thermomechanical treatment can introduce low energy segments in the grain boundary network by annealing twins and can arrest the percolation of intergranular corrosion from the surface.

  • PDF

Sr(NO3)2 용융염에서 이온교환이 K2O-TiO2-SiO2 glass에 미치는 영향 (Effect of strontium ions on K2O-TiO2-SiO2 glass soaked in molten Sr(NO3)2)

  • 박노형;유은성;이회관;허훈
    • 한국결정성장학회지
    • /
    • 제21권5호
    • /
    • pp.214-217
    • /
    • 2011
  • Fresnoite 결정화 유리는 최근 비선형 광학특성으로 인하여 널리 연구되어 지고 있다. 그러나, 이전 연구 결과를 통하여 투명결정화 유리의 화학 조성으로는 정량적으로 Fresnoite 구조에 유사한 조성을 조절하는 것에 한계가 있음을 확인 할 수 있다. 본 연구에서는 $K_2O-TiO_2-SiO_2$ glass의 제조한 후, 제조된 유리를 $Sr(NO_3)_2$ 용융염에 담지하여 모유리의 표면에 Fresnoite 결정을 형성시키는 방법으로 투명결정화 유리를 제조하고, 이 때 Sr 이온이 비선형광학효과에 미치는 영향을 살펴보았다. XRD를 통하여 담지 시간에 따른 결정상 변화와 열처리를 통한 결정상 변화를 관찰하였으며, FE-SEM을 사용하여 생성된 결정의 미세구조와 Nd : YAG laser를 사용하여 2차비선형특성의 유무를 관찰하였다.

다중양자우물구조의 상호섞임을 이용한 광도파로의 제작 및 측정 (Fabrication and Measurement of Optical Waveguide using Multi Quantum Well Intermixing)

  • 여덕호;윤경훈;김성준
    • 전자공학회논문지D
    • /
    • 제36D권7호
    • /
    • pp.50-55
    • /
    • 1999
  • Separate confinement heterostructure(SCH) 구조를 갖는 InGaAs/InGaAsP 다중양자우물구조의 상호섞임을 이용하여 광도파로를 제작하였다. 광도파로는 $CH_4/H_2$ 혼합가스를 이용한 반응성 이온 식각 방식으로 제작하였으며, 제작된 광도파로는 폭이 $5{\mu}m$이고, 식각 깊이가 $1.2{\mu}m$이다. 광도파로의 전송손실은 tunable laser를 이용한 Fabry-Perot 간섭현상을 이용하여 측정하였다. $800^{\circ}C$, 30s 열처리한 후 제작된 광도파로는 1550,nm TE 모드에서 3.76dB/cm, TM 모드에서 3.95dB/cm의 전송손실을 보였다. 이 전송 손실은 지금까지 ,IFVD를 이용해 제작한 광도파로와 비교해서 매우 작은 값이다. 따라서, 이 방법은 광도파로등의 수동소자와 전자소자의 집적에 응용될 수 있다.

  • PDF

티타늄과 금합금의 레이저 용접부의 인장강도 (TENSILE STRENGTH OF LASER WELDED-TITANIUM AND GOLD ALLOYS)

  • 송윤관;송광엽;하일수
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.200-213
    • /
    • 2000
  • Lasers have given dentistry a new rapid, economic, and accurate technique for metal joining. Although laser welding has been recommended as an accurate technique, there are some limitations with this technique. For example, the two joining surfaces must have a tight-fitting contact, which may be difficult to achieve in some situations. The tensile samples used for this study were made from a custom-made pure titanium and type III gold alloy plates. 27 of 33 specimens were sectioned perpendicular to their long axis with a carborundum disk and water coolant. Six specimens remained and served as the control group. A group of 6 specimens was posed as butt joints in custom parallel positioning device with a feeler gauge at each of three gaps : 0.00, 0.25. and 0.50mm. All specimens were then machined to produce a uniform cross-sectional dimension, none of the specimens was subjected to any subsequent form of heat treatment. Scanning electron microscopy was performed on representative tested specimens at fractured surfaces in both the parent metal and the weld. Vickers hardness was measured at the center of the welds with a micropenetrometer using a force of 300gm for 15 seconds. Measurement was made at approximately $200{\mu}m\;and\;500{\mu}m$ deep from each surface. One-way analysis of variance (ANOVA) and Scheffe's test was calculated to detect differences between groups. The purpose of this study is to compare the strength and properties of the joint achieved at various butt Joint gaps by the laser welding of type III gold alloy and pure titanium tensile specimens in an argon atmosphere. The results of this study were as follows : 1. When indexing and welding pure titanium, there was no decrease in ultimate tensile strength as compared with the unsectioned alloys for indexing gaps of 0.00 to 0.50mm, although with increasing gap size may come increased distortion (p>0.05). 2. When indexing and welding type III gold alloy, there were significant differences in ultimate tensile strength among groups with weld gaps of 0.00mm, 0.25 and 0.50mm, and the control group. Group with butt contact without weld gap demonstrated a significant higher ultimate tensile strength than groups with weld gaps of 0.25 and 0.50mm (p<0.05). 3. When indexing and welding the different metal combination of type III gold alloy and pure titanium, there were significant differences in ultimate tensile strength between groups with weld gaps of 0.00, 0.25, and 0.50mm. However, the mechanical properties of the welded joint would become too brittle to be acceptable clinically (p<0.05). 4. The presence of large pores in the laser welded joint appears to be the most important factor in controlling the tensile strength of the weld in both pure titanium and type III gold alloy.

  • PDF

Investigation of Planar Optical Waveguide Formed by MeV $He^{+}$ Ion-Implantation into NaEr(WO$_4$)$_2$ Crystal

  • Feng Chen;Wang, Xue-Lin;Wang, Ke-Ming;Cheng, Zhen-Xiang;Chen, Huan-Chu;Shen, Ding-Yu
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제6권2호
    • /
    • pp.97-100
    • /
    • 2002
  • NaEr(WO$_4$)$_2$ is a new laser material. The planar optical waveguide was formed in NaEr(WO$_4$)$_2$ crystal by 2.6 MeV He$^{+}$ ion implantation at doses of 1.0-1.5 $\times$ 10$^{16}$ ions/cm$^2$ at room temperature. The effective refractive indices of the dark modes were measured using the prism coupling method. foul n modes and five TM modes were observed in the waveguide. The refractive index profiles were analyzed using the reflectivity calculation method (RCM). The influence of heat treatment at moderate temperature on the refractive index profiles of the waveguide was also investigated. We used the TRIM'98 (Transport of ton in Matter) code to simulate the damage profile in the NaEr(WO$_4$) crystal by 2.6 MeV He$^{+}$ion implantation which is helpful for a better understanding of the waveguide formation.ion.

  • PDF