A Spatio-Temporal Density Measurement of NO Molecules in Pulsed Barrier Discharge Using Laser Induced Fluorescence (레이져 유기형광법을 이용한 펄스 배리어 방전 공간에서의 NO분자에 대한 시·공간적 밀도변화 측정)

  • Han, Sang-Bo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제24권5호
    • /
    • pp.160-168
    • /
    • 2010
  • This paper tried to find out NO generation and removal mechanisms in the space of the atmospheric pulsed barrier discharge using laser induced fluorescence method, which is a very effective approach to the measurement of spatio-temporal density of specific molecules. The propagation velocity of the primary streamer reaches about $2.7{\times}10^6$[m/s] and the secondary streamer is produced in the vicinity of positive electrode after the primary streamer finished. In this work, pulse Nd:Yag and Dye lasers are used for generating the specific wavelength of 226[nm], which is possible to excite NO molecules into $A^2{\Sigma}^+{\rightarrow}X^2{\prod}$(0,0) and fluorescence signals as the transition of $A^2{\Sigma}^+{\leftarrow}X^2$(0,2) is measured. For the effective removal of NO molecules in the plasma discharge process, the lower oxygen contents are needed and the influence of secondary streamer for the reduction mechanism of NO molecules is important

Measuring Plate Thickness Using Spatial Local Wavenumber Filtering (국소 공간 웨이브넘버 필터링 기법을 이용한 평판 구조물 두께 측정)

  • Kang, To;Lee, Jeong Han;Han, Soon Woo;Park, Jin Ho;Park, Gyuhae;Jeon, Jun Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제36권5호
    • /
    • pp.370-376
    • /
    • 2016
  • Corrosion on the surface of a structure can generate cracks or cause walls to thin. This can lead to fracturing, which can eventually lead to fatalities and property loss. In an effort to prevent this, laser imaging technology has been used over the last ten years to detect thin-plate structure, or relatively thin piping. The most common laser imaging was used to develop a new technology for inspecting and imaging a desired area in order to scan various structures for thin-plate structure and thin piping. However, this method builds images by measuring waves reflected from defects, and subsequently has a considerable time delay of a few milliseconds at each scanning point. In addition, the complexity of the system is high, due to additional required components, such as laser-focusing parts. This paper proposes a laser imaging method with an increased scanning speed, based on excitation and the measurement of standing waves in structures. The wavenumber of standing waves changes at sections with a geometrical discontinuity, such as thickness. Therefore, it is possible to detect defects in a structure by generating standing waves with a single frequency and scanning the waves at each point by with the laser scanning system. The proposed technique is demonstrated on a wall-thinned plate with a linear thickness variation.

A Generator of Gaseous Singlet Oxygen

  • Matsuura, Teruo;Sato, Hideya;Suzuki, Nobutaka;Matsumoto, Masakatsu
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.409-411
    • /
    • 2002
  • In order to prevent side reactions due to free radical formation occurring in the reactions of singlet oxygen generated in solution phse, it was required that singlet oxygen is generated in gas phase from an apparatus of a solid-gas system. We have accomplished to construct an apparatus generating singlet oxygen in solid-gas system, which is composed of a flexible optical fibre tube connected by a dye-sensitizer probe containing rose bengal dye on polymer or inorganic material. Through the optical fibre tube visible light from a laser and an oxygen stream are passed into the sensitizer probe where singlet oxygen is generated. The determination of singlet oxygen was carried out by two methods. One involves the detection of the luminescence of singlet oxygen at 1268 mn and the other involves the chemiluminescence reaction of a dihydroisobenzofuran with singlet oxygen emitting luminescence at 456 nm.

  • PDF

Zigzag Tool-Path Linking Algorithm for Shaping Process Using Heat Source (열원을 이용한 공정에서 지그재그 공구 경로 연결 알고리즘)

  • Kim H. C.;Lee S. H.;Yang D. Y.
    • Korean Journal of Computational Design and Engineering
    • /
    • 제9권4호
    • /
    • pp.286-293
    • /
    • 2004
  • Recently, hot processing using the heat source like laser machining and RFS was developed and spreaded gradually. In order to generate tool-path for the proper hot tool, a new tool-path linking algorithm is needed because tool-path linking algorithm for machining can't be applied. In this paper, zigzag tool-path liking algorithm was proposed to generate tool-path automatically for RFS. The algorithm is composed of three steps: 1) Generating valid tool-path element, 2) Storing tool-path elements and creating sub-groups, 3) linking sub-groups. Using the proposed algorithm, CAD/CAM software for the tool-path generation of hot tool was developed. The proposed algorithm was applied and verified for Venus's face and die of cellular phone case.

Optical Detection of Red Blood Cell Aggregation under vibration (진동장에서의 적혈구 응집성을 측정하는 광학적 방법)

  • Jang, Ju-Hee;Park, Myung-Su;Ku, Yun-Hee;Shin, Se-Hyun
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1510-1515
    • /
    • 2004
  • Aggregability of red blood cells (RBCs) was determined by a laser backscattering light analysis in a microfluidic channel. Available techniques for RBC aggregation often adopt a rotational Couette-flow using bob-and-cup system for disaggregating RBCs, which causes the system to be complex and expensive. A disposable microfluidic channel and vibration generating mechanism were used in the proposed new detection system for RBC aggregation. Prior to measurement, RBC aggregates in a blood sample were completely disaggregated by applying vibration-induced shear. With the present apparatus, the aggregation indexes of RBCs can be easily measured with small quantities of blood sample. The measurements with the present aggregometer were compared with those of LORCA and showed a strong correlation between them. The aggregability of the defibrinogenated blood RBCs is markedly lower than that of the normal RBCs. The noble feature of this design is the vibration-induced disaggregation mechanism, which enables to incorporate disposable element that holds the blood sample.

  • PDF

Recognition of Patterns and Marks on the Glass Panel of Computer Monitor (컴퓨터 모니터용 유리 패널의 문자 마크 인식)

  • Ahn, In-Mo;Lee, Kee-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제52권1호
    • /
    • pp.35-41
    • /
    • 2003
  • In this paper, a machine vision system for recognizing and classifying the patterns and marks engraved by die molding or laser marking on the glass panels of computer monitors is suggested and evaluated experimentally. The vision system is equipped with a neural network and an NGC pattern classifier including searching process based on normalized grayscale correlation and adaptive binarization. This system is found to be applicable even to the cases in which the segmentation of the pattern area from the background using ordinary blob coloring technique is quite difficult. The inspection process is accomplished by the use of the NGC hypothesis and ANN verification. The proposed pattern recognition system is composed of three parts: NGC matching process and the preprocessing unit for acquiring the best quality of binary image data, a neural network-based recognition algorithm, and the learning algorithm for the neural network. Another contribution of this paper is the method of generating the training patterns from only a few typical product samples in place of real images of all types of good products.

Development of Measurement System for Tappet Rotation in the Valve Train System (밸브 트레인 시스템의 태핏 회전 측정 장치의 개발)

  • 김형준;조명래;신흥주;한동철
    • Tribology and Lubricants
    • /
    • 제14권3호
    • /
    • pp.81-86
    • /
    • 1998
  • The purpose of this paper is to measure the rotational speed of tappet in OHC valve train system. Tappet has eccentricity about cam center, which induces the tappet rotation and prevents from wear. In this paper, the experimental test rig which composes of one cam system is developed to measure the tappet rotation by using the laser generating system, rotary encoder, optical fiber, and photo transistor. The direction of tappet rotation is judged from the oder of optical signal. As results of experiment, average and instant rotational speed and average rotation angle per one cam revolution are presented. Measured results show that eccentricity ratio is dominant factor for the tappet rotation, and tappet is rotated at the base circle.

Simultaneous Generation of Orthogonally Polarized Signals in an Optical Parametric Oscillator Based on Periodically Poled Lithium Niobate

  • Kumar, CH. S.S. Pavan;Kim, Byoung Joo;Kim, Deok Woo;Cha, Myoungsik
    • Current Optics and Photonics
    • /
    • 제4권1호
    • /
    • pp.63-68
    • /
    • 2020
  • We built an optical parametric oscillator (OPO) generating orthogonally polarized signals at different wavelengths simultaneously, based on a periodically poled lithium niobate (PPLN) crystal. The OPO was pumped by ns-pulses at 1.064 ㎛ from a diode-pumped solid-state laser, where we found the type-0 and the type-1 quasi-phase matching conditions were satisfied simultaneously in the PPLN crystal. This enabled us to create a coherent light source which can emit dual signals which could be accessed easily by rotating a polarizer.

A study on development of CAD/CAM system for plasma-arc cutting process (플래즈머 아크절단용 CAD/CAM 시스템 개발에 관한 여구)

  • 엄두간;노태정;한국찬;나석주;나규환
    • Journal of Welding and Joining
    • /
    • 제9권3호
    • /
    • pp.52-61
    • /
    • 1991
  • In the recent years the computer-numerical controlled cutting process such as a plasma arc cutting and a laser cutting is widely applied to reduce the time and cost expense for generating NC part program of the parts to be cut. In the present study, a CAD system(C-CAD) was developed to generate automatically the NC part programs with CLDAT(Cutter Location Data)for the CNC plasma arc cutting system. The NC part programs are composed of the 2-dimensional drawing of the parts to be cut and the technological data. The shape data of the parts drawn in the Auto-CAD can be also used in the C-CAD, since the data file generated by the C-CAD is compatible with that by the Auto-CAD. In order to check its applicability, the C-CAD and CAM system were applied to cut the parts, and which showed the satisfactory results.

  • PDF

Geometric error compensation of machine tools by geometry redesign (형상 재 설계에 의한 공작기계 기하오차 보정)

  • 서성교
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.367-372
    • /
    • 2000
  • Accuracy of a machined component is determined by the relative motion between the cutting tool and the workpiece. One of the important factors which affects the accuracy of this relative motion is the geometric error of machine tools. In this study, geometric error is modeled using form shaping motion of machine tool, where a form shaping function is derived from the homogeneous transformation matrix. Geometric errors are measured by laser interferometer. After that, the local positioning error can be estimated from the form shaping model and geometric error data base. From this information, we can remodel the part by shifting the design surface to the amount of positional error. By generating tool path to the redesigned surface, we can reduce the machining error.

  • PDF