• Title/Summary/Keyword: Laser Doppler vibrometer

Search Result 89, Processing Time 0.025 seconds

Performance limit of digital vibrometer using self-mixing type LDV

  • Shinohara, Shigenobu;Hara, Katsuhiko;Toyoshima, Morio;Ikeda, Hiroaki;Yoshida, Hirofumi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.170-173
    • /
    • 1995
  • Recently, we proposed a compact digital vibrometer using a self-mixing laser Doppler velocimeter (SM-LDV). In this paper, we theoretically obtained formulas giving lower and upper limit of measurable velocity. In the prototype digital vibrometer, the theoretical value was 6.7mm/s and 162.8mm/s, respectively, which agreed well with the measured value. The upper limit of measurable displacement amplitude was 12OO.mu.m at 10Hz, and 250.mu.m at 100Hz. Furthermore, the measurement accuracy the displacement amplitude was within -3% and average error -1.3%, when the shape of the sawtooth contained in the Doppler beat signal is clear and sharp. The measurement accuracy is found to depend on a degree of sawtooth asymmetry (DSA).

  • PDF

Characterization of Frequency Separation in Polymer Membranes Mimicking a Human Auditory System (생체 청각기구를 모사한 폴리머 박막의 주파수 분리 특성 평가)

  • Song, Won-Joon;Bae, Sung-Jae;Kim, Wan-Doo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.516-521
    • /
    • 2011
  • The basilar membrane, an important functional part of the cochlea, is responsible for spectral separation of vibration signals transmitted from the stapes. In current study, scaled-up polymer membranes designed by mimicking the human basilar membrane were used for investigation of the frequency-separation characteristic. Displacement field formed on each polymer membrane was acquired by Laser Doppler scanning vibrometer and post-processed frequency-wise. The locations of the maximum displacement along the centerline were identified and collected for individual frequency range to produce the frequency-position map of individual polymer membrane. The influences of the membrane thickness and material properties on the variation of the frequency separability were discussed.

Noncontact Laser Ultrasonic Imaging for Automated Damage Detection (자동화 손상 검색을 위한 비접촉식 레이저 초음파 영상화)

  • Park, Byeong-Jin;An, Yun-Kyu;Sohn, Hoon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.40-43
    • /
    • 2011
  • 최근, 레이저 초음파 영상화 기법은 구조물의 비접촉식 손상 진단을 위해 널리 연구되고 있다. 초음파 영상화 기법의 가장 큰 장점은 비접촉식으로 구조물의 손상을 진단할 수 있고, 가진 및 측정 지점을 자유로이 이동할 수 있다는 점이다. 따라서 이는 고온이나 동적상태의 구조물에 적용이 가능하며, 시간과 공간상의 충분한 데이터를 획득할 수 있으므로 역문제 (Inverse problem)를 해결할 필요 없이 완전한 초음파의 전파 형상을 얻을 수 있다. 지난 연구들에서는 충분한 가진력 혹은 측정 민감도를 확보하기 위해 가진 레이저와 부착형 센서의 조합이나 부착형 가진 트렌스듀서와 센싱 레이저의 조합으로 초음파 영상을 획득하고자 하였다. 하지만 이들 조합은 가진 혹은 측정 지점이 구조물에 부착되어 있어 완전한 비접촉식 기법을 구현하지 못하였다. 이를 극복하고자 레이저와 EMAT 센서 등의 조합이 시도되어 왔으나, 이 또한 EMAT 센서의 적용 거리에 따른 한계점을 지니고 있다. 본 연구에서는 가진 레이저 (Nd:Yag)의 스캐닝을 통해 다양한 가진 점에서 발생된 초음파가 탄성체 구조물을 통해 전파되고, 이를 센싱 레이저 (Laser Doppler Vibrometer)를 이용하여 측정함으로써 비접촉식 초음파 영상화를 구현하였다. 나아가, 정상파 필터(Standing-wave filter)를 이용하여 구현된 초음파 영상으로부터 손상 영향만 검출해 내는 기법을 개발했다. 개발된 기법은 복합재 시편의 층간박리 (Delamination) 진단을 통해 검증하였다.

  • PDF

Laser Doppler Vibrometer using the Bulk Homodyne Interferometer (호모다인 간섭계를 이용한 레이저 진동 측정기의 개발)

  • 라종필;경용수;왕세명;김경석;박기환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.397-402
    • /
    • 2003
  • The FM demodulation method for a bulk homodyne laser interferometer is presented. The Doppler frequency that represents the surface velocity of a vibrating object is obtained by using the bulk homodyne laser interferometer, and converted to the voltage signal by using the proposed analogue FM demodulation circuit. The DC offsets of the interferent signals that are obtained from the bulk homodyne interferometer are eliminated by using a simple subtraction. The new method for compensation of the asymmetry of each channels is presented. The light power variation of the interferometer is normalized by using the Auto Gain Controller(AGC). The proposed FM demodulation algorithm is proved by the theoretical method, and validated by the experimental results. In experiments, the proposed FM demodulation algorithm is compared with the conventional demodulation methods.

  • PDF

Experimental Modal Analysis by Using Hilbert Transform of Signal from Continuous Scanning Laser Vibrometer (연속 스캐닝 레이저 진동계 신호의 Hilbert 변환을 이용한 실험적 모드 해석)

  • Kang, Min-Sig;Chang, Tae-Gyu;Kim, Ho-Sung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.6
    • /
    • pp.272-277
    • /
    • 2002
  • This paper deals with the vibration deflection shape measurement technique for a sinusoidally excited structure using a continuously scanning laser Doppler vibrometer (CSLV). The CSLV output signal is an amplitude-modulated vibration in which the excitation signal is modulated by the deflection shapes, and thus the deflection shapes of vibration defined along a scan line can be derived by the envelop and the phase information of the CSLV output signal. In this work, a Hilbert transform based approach has been proposed for measurement of deflection shapes. This technique is as simple as the demodulation technique and allows more convenient experimental settings than the Fourier transform approach. The feasibility of the proposed technique is illustrated along with results of experiment.

Measurement System of Dynamic Liquid Motion using a Laser Doppler Vibrometer and Galvanometer Scanner (액체거동의 비접촉 다점측정을 위한 레이저진동계와 갈바노미터스캐너 계측시스템)

  • Kim, Junhee;Shin, Yoon-Soo;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.5
    • /
    • pp.227-234
    • /
    • 2018
  • Researches regarding measurement and control of the dynamic behavior of liquid such as sloshing have been actively on undertaken in various engineering fields. Liquid vibration is being measured in the study of tuned liquid dampers(TLDs), which attenuates wind motion of buildings even in building structures. To overcome the limitations of existing wave height measurement sensors, a method of measuring liquid vibration in a TLD using a laser Doppler vibrometer(LDV) and galvanometer scanner is proposed in this paper: the principle of measuring speed and displacement is discussed; a system of multi-point measurement with a single point of LDV according to the operating principles of the galvanometer scanner is established. 4-point liquid vibration on the TLD is measured, and the time domain data of each point is compared with the conventional video sensing data. It was confirmed that the waveform is transformed into the traveling wave and the standing wave. In addition, the data with measurement delay are cross-correlated to perform singular value decomposition. The natural frequencies and mode shapes are compared using theoretical and video sensing results.

Rail Inspection Using Noncontact Laser Ultrasonics

  • Kim, Nak-Hyeon;Sohn, Hoon;Han, Soon-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.6
    • /
    • pp.696-702
    • /
    • 2012
  • In this study, a noncontact laser ultrasonic system is proposed for rail defect detection. An Nd-Yag pulse laser is used for generation of ultrasonic waves, and the corresponding ultrasonic responses are measured by a laser Doppler vibrometer. For the detection of rail surface damages, the shape of the excitation laser beam is transformed into a line. On the other hand, a point source laser beam is used for the inspection of defects inside a rail head. Then, the interactions of propagating ultrasonic waves with defects are examined using actual rail specimens. Amplitude attenuation was mainly observed for a surface crack, and reflections were most noticeable from an internal damage. Finally, opportunities and challenges associated with real-time rail inspection from a high-speed train are discussed.

Reliability and utility of a Dry Test Bench for testing the acoustic output from a ballistic shock wave therapeutic device (탄도형 충격파 치료기의 음향 출력 시험을 위한 Dry Test Bench의 신뢰성 및 유용성)

  • Jeon, Sung Joung;Lee, Min Young;Kwon, Oh Bin;Kim, Jong Min;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.589-600
    • /
    • 2022
  • In order to verify the reliability of Dry Test Bench (DTB) used for testing the output energy from ballistic extracorporeal shock wave therapeutic devices, the measurements with DTB were compared with the acoustic energy measured with a Laser Doppler Vibrometer (LDV) for a commercial ballistic ESWT device. It was shown that the mechanical energy detected with DTB had variability maintained within 5 % at the same output power setting and also had a linear correlation (adj. R2 = 0.991) with the acoustic energy measured with the LDV for the entire output power settings. Using the correlation between the two methods and the correlation on the acoustic energy measured in between air and water with the LDV, the DTB measurement can be used to estimate the energy flux density in water with an average error of 7.85 % for the entire output power settings of the ballistic shock wave generator considered in the experiment. DTB provides information limited to the output mechanical energy and therefore it is not suitable for testing the various acoustic output parameters required in IEC61846 and IEC63045. However, DTB that is simple in measurement principles and easy to use is expected for manufacturers and clinical users to monitor the performance of ballistic Extracorporeal Shock Wave Therapy (ESWT) devices.

Zeeman 안정화 He-Ne 레이저 및 One-shot F/V 변환기를 이용한 헤테로다인 진동측정기

  • 라종필;최현승;박기환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.168-168
    • /
    • 2004
  • 본 논문은 헤테로다인 간섭계를 이용한 레이저 진동 측정기에 대해 기술하고 있다. 상용 레이저 진동 측정기가 대부분 AOM을 이용하여 주파수 천이를 일으키는 반면, 본 연구에서는 Zeeman 안정화 He-Ne 레이저를 사용하므로써, 서로 다른 주파수를 가지는 레이저를 동시에 얻을 수 있었다. 따라서, Zeeman 안정화 He-Ne 레이저를 사용하는 진동측정기의 경우 간섭계 구성을 위해 사용되는 비용을 현저히 줄일 수 있다. 또한, AOM의 고주파 신호를 처리하기 위해서는 RE 대역의 신호처리 회로 설계가 필요하지만, Zeeman 안정화 레이저의 주파수 천이가 낮으므로, 제안된 진동측정기의 신호처리가 용이하다.(중략)

  • PDF