• 제목/요약/키워드: Laser Absorption Technique

검색결과 52건 처리시간 0.029초

레이저 빔 단면확대를 이용한 나노 복화(複畵)공정의 패턴 정밀도 향상에 관한 연구 (Fabrication of Precise Patterns using a Laser Beam Expanding Technique in Nano-Replication Printing (nRP) Process)

  • 박상후;임태우;양동열;이신욱;공홍진
    • 한국정밀공학회지
    • /
    • 제22권1호
    • /
    • pp.175-182
    • /
    • 2005
  • A laser beam expanding technique is employed to fabricate precise nano-patterns in a nano-replication printing (nRP) process. In the nRP process, some patterns can be fabricated in the range of several microns inside on a polymerizable resin by using a volume-pixel (voxel) matrix that is transformed from a two-tone bitmap figure file. The liquid monomers are polymerized by means of a two-photon-absorption (TPA) phenomenon that is induced by a femtosecond (fs)-pulse laser. The yokels are generated consecutively to merge into adjoining yokels in the process of fabricating a pattern. The resolution of a fabricated pattern can be obtained under the diffraction limit of a laser beam by the two-photon absorbed polymerization (TPP). In this work, a beam-expanding technique has been applied to enlarge a working area and to fabricate precise patterns. Through this work, a working area is expanded by the technique as much as 2.5 times compared with a case of without a beam expanding technique, and precision of outside patterns is improved.

LII 신호에 대한 입사 레이저 특성의 영향 (An effect of the characteristics of incident laser beams on laser-induced incandescence signals)

  • 정종수;이교우
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1997년도 제15회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.45-50
    • /
    • 1997
  • An experimental study on LII signal images from soot particles in a flame has been carried out in order to investigate the effect of the incident laser characteristics. By changing the wavelength of the incident laser beam, the LII signal was saturated at smaller laser power with 532 nm than 1,064 nm. This implies that the larger absorption coefficient of soot particles at 532 nm would influence the LII signal characteristic. Using the deconvolution technique, the projected LII line images were coverted to reconstruct the local LII signals inside the beam. The results show that the LII images at ICCD camera result from the integration of LII signal across the laser beam.

  • PDF

연속발진 레이저를 이용한 공동 광자감쇠 분광기 연구 (Study on a cavity ring-down spectrometer with continuous wave laser sources)

  • 유용심;한재원;김재완;이재용;이해웅
    • 한국광학회지
    • /
    • 제9권4호
    • /
    • pp.240-244
    • /
    • 1998
  • 공동 광자 감쇠 분광법(cavity ring down spectroscopy, CRDS)은 미량기체의 절대밀도를 측정할 수 있는 고감도 레이저 분광기술이다. 연속발진 레이저(continuous wave laser)를 사용한 새로운 방법의 CRDS 분광기를 구현하였다. 이 장치에서는 PZT(piezoelectric transducer)를 움직여 공동의 길이를 비공명(off-resonance)상태로 빠르게 변화시킴으로써 입사되는 연속발진 레이저 빔을 차단하여 감쇠신호를 발생시킨다. 이 방법으로 570 nm 근처에서 압력이 2700 Pa인 아세틸렌(C2H2)의 overtone 천이에 대한 흡수 분광선을 측정하였으며, 이때 측정할 수 있는 최소 흡수계수는 3$\times$10-9 cm-1정도이다.

  • PDF

A Four-Channel Laser Array with Four 10 Gbps Monolithic EAMs Each Integrated with a DBR Laser

  • Sim, Jae-Sik;Kim, Sung-Bock;Kwon, Yong-Hwan;Baek, Yong-Soon;Ryu, Sang-Wan
    • ETRI Journal
    • /
    • 제28권4호
    • /
    • pp.533-536
    • /
    • 2006
  • A distributed Bragg reflector (DBR) laser and a high speed electroabsorption modulator (EAM) are integrated on the basis of the selective area growth technique. The typical threshold current is 4 to 6 mA, and the side mode suppression ratio is over 40 dB with single mode operation at 1550 nm. The DBR laser exhibits 2.5 to 3.3 mW fiber output power at a laser gain current of 100 mA, and a modulator bias voltage of 0 V. The 3 dB bandwidth is 13 GHz. A 10 Gbps non-return to zero operation with 12 dB extinction ratio is obtained. A four-channel laser array with 100 GHz wavelength spacing was fabricated and its operation at the designed wavelength was confirmed.

  • PDF

미량 기체의 밀도 측정을 위한 외부 공진기 반도체 레이저 광학공동 적분 투과 분광법 (Integrated Cavity Output Spectroscopy Using an External Cavity Diode Laser for the Density Absorption Measurement of Trace Gases)

  • 류훈철;유용심;이재용;한재원
    • 한국진공학회지
    • /
    • 제15권1호
    • /
    • pp.24-30
    • /
    • 2006
  • 광학공동 적분 투과 분광법(integrated cavity output spectroscopy, ICOS)은 파장가변 레이저와 광학공동을 이용해 미량기체의 절대 밀도를 고감도로 측정할 수 있는 실시간 흡수 분광계측 기법이다. 이 기법은 압전 소자를 이용해 길이가 변조되는 고 피네스(high finesse) 파브리-페로 공동(Fabry-Perot cavity)을 공명 투과하는 연속파 파장 변조 레이저의 적분 출력으로 부터 공동 내부 시료의 분광 흡수량을 측정하는 원리를 이용한다. 본 연구에서는 764,7nm 파장 근처에서 파장이 변조되는 외부 공진기 반도체 레이저를 광원으로 사용하고, $99.997\%$의 높은 반사율을 갖는 거울로 구성된 파브리-페로 공동을 이용해 파장에 따른 투과 감쇠 신호를 발생시키는 실험 장치를 구성하였다. 산소 기체에 대한 측정 실험을 수행한 결과, 최소 흡수계수 $8.45\times10^{-8}cm^{-1}$에 해당하는 미량기체 밀도를 측정할 수 있는 성능을 얻었다.

피부질환을 위한 $CO_2$ 레이저의 공극 (1.0mm 및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성연구 (Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease)

  • 김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.156-158
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is avaliable to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is avaliable Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

레이저의 편광을 고려한 키홀 거동 해석에 관한 연구 (A Study on the Keyhole Dynamics According to Polarization of Laser)

  • 조정호;나석주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1307-1311
    • /
    • 2007
  • Three-dimensional transient keyhole profile is numerically analyzed for the case of stationary laser keyhole welding. Volume of fluid (VOF) method is adopted to track the free surface of molten metal based on the three governing equations which are continuity, momentum and energy equations. Multiple reflections of laser beam at the keyhole walls are also included in analysis through a real-time ray tracing technique. In this simulation, especially, polarization of laser is considered as an energy absorption mechanism following the Fresnel reflection theory. Both cases of linearly and circularly polarized beam are simulated and compared. The results show that the theoretically generated keyhole is asymmetrically stretched along the direction of polarization which is already observed experimentally before.

  • PDF

고출력 $CO_2$레이저빔에 의한 구리, 청동/알루미늄 합금 클래딩 (Cladding of Cu and Bronze/Al Alloy by $CO_2$ Laser)

  • 강영주;김재도
    • Journal of Welding and Joining
    • /
    • 제15권4호
    • /
    • pp.109-115
    • /
    • 1997
  • Laser cladding is a technique for modification of metal surface. In this laser cladding experiment a metal powder feeding system was developed for more efficient laser cladding. This system can reduce processing time and be used simpler than the conventional method. The feeding of metal powder has given a rise to the process for sequential buildup of bulk rapidly solidified materials in the form of fine powder stream to the laser cladding process. The parameters of laser cladding have been investigated using this experimental equipment. Bronze on aluminum alloy and copper on aluminum alloy were experimented by using defocused beam, powder feeding system, and gas shielding. Good cladding was achieved in the range of beam travel speed of 2.25m/min. In the case of copper/aluminum and bronze/aluminum substrate, the absorption of laser beam was too high to produce low diluted clad. In the case of copper/1050 aluminum, the optimal laser cladding condition was of laser power of 2.8kW, powder feed rate of 0.31g/s and beam travel speed of 2.25m/min. In the case of bronze/aluminum the optimal condition is of laser power of 2.5kW, powder feed rate of 0.31g/s, and beam travel speed of 2.36m/min.

  • PDF

아르곤 레이저의 소아치과에서의 임상적 적용 (CLINICAL APPLICATION OF ARGON LASER IN PEDIATRIC DENTISTRY)

  • 이미나;이상훈;김종철
    • 대한소아치과학회지
    • /
    • 제24권1호
    • /
    • pp.139-147
    • /
    • 1997
  • Argon laser used in this case report, is special in having two wavelength of 488, 514nm blue-green visible light spectrum. Blue light is used for composite resin polymerization and caries detection. Green light is used for soft tissue surgery and coagulation. Maximum absorption of this laser light occurs in red pigmentation such as hemoglobin. The argon laser may be well-suited for selective destruction of blood clots and hemangioma with minimal damage to adjacent tissues. Argon laser light penetrates tissue to the 1 mm depth, so its thermal intensity is lower than $CO_2$ laser light. Also, due to its short wavelength it can be focused in a small spot and even single gene can be excised by this laser and microscopy. After applicating argon laser to 4 patient for surgical procedure and to 1 patient for curing the composite resin, following results were obtained. 1. Improved visibility were gained due to hemostasis and no specific technique were needed according to easy recontouring of the tissue. 2. Ability to use by contact mode, tactile sense was superior but tissue dragability and accumulation of tissue on the tip needed sweeping motion. 3. Additive local anesthetic procedure was needed. 4. No suture and less curing time reduced chair time, this made argon laser available in pediatric dentistry.

  • PDF

Spin-coating에 의한 $Ge_{20}As_{20}Se_{60}$ 비정질 chalcogenide 박막의 제조 및 광특성 분석 (Preparation and Characterization of $Ge_{20}As_{20}Se_{60}$ Amorphous Chalcogenide Thin Film by Spin Coating)

  • 이강구;최세영
    • 한국세라믹학회지
    • /
    • 제37권3호
    • /
    • pp.219-226
    • /
    • 2000
  • Amorphous Ge20As20Se60 chalcogenide thin films were prepared by spin coating technique from mixed solutions of As40Se60 and Ge40Se60 dissolved in ethylenediamine. Films were prepared at a roating speed of 3500 rpm and spinning time was 10 second and heat-treateed at 27$0^{\circ}C$ for 1 hour. The resulting film thickness and RMS roughness were approximately 340 nm and 15$\AA$. Photostructure changes were investigated with 514.5nm Ar+ laser irradiation and heat-treatment. After Ar+ laser irradiation, transmittance and transmission efficiency decreased respectively up to 24.9% at 2.43 eV and 67.5% at 3.27 eV, and absorption edge shifted toward long wavelength. Optical bandgap changed from 2.03 to 1.83 eV, and absoprtion coefficient and absorption efficiency increased up to 0.33$\times$105cm-1 at 3.37eV and 88.3% at 1.31 eV, respectively. These photodarkening state were recovered reversibly by heat-treatment at 27$0^{\circ}C$ for 1 hour. Photodarkening and thermal bleaching effects by laser irradiation and heat-treatment revealed reversible amorphous-to-amorphous transition varying only coordination number.

  • PDF