• Title/Summary/Keyword: Large-surface

Search Result 5,651, Processing Time 0.036 seconds

On the Warming Effects due to Artificial Constructions in a Large Housing Complex (대규모 주택단지내의 인공구조물에 의한 승온화효과에 관한 연구)

  • 김해동;이송옥;구현숙
    • Journal of Environmental Science International
    • /
    • v.12 no.7
    • /
    • pp.705-713
    • /
    • 2003
  • In mid-August 2002, under clear summer pressure patterns, we carried out an intensive meteorological observation to examine the warming effects due to artificial constructions in a large housing complex. We set an automatic weather system(AWS) at two places in a bare soil surface within a limited development district and an asphalt surface within a large apartment residence area, respectively. As a result of observation, it became clear that the difference of the surface air(ground) temperature between the bare soil surface and its peripheral asphalt area reached about 4$^{\circ}C$(13$^{\circ}C$) at the maximum from diurnal variation of surface temperatures on AWS data. Through the heat balance analysis using measurement data, it became clear that the thermal conditions at two places are dependent on the properties of surface material. The latent heat flux over the bare soil surface reached to about 300 W/㎡, which is more than a half of net radiation during the daytime. On the other hand, it was nearly zero over the asphalt surface. Hence, the sensible heat flux over the asphalt surface was far more than that of the bare soil surface. The sensible heat flux over the asphalt surface showed about 20∼30 W/㎡ during the night. It was released from asphalt surface which have far more heat capacity than that of bare soil surface.

A Study on the Property of the Foot Form through a Development Figure of the Surface Area (발의 체표면적 특성에 관한 연구)

  • 문명옥
    • Journal of the Korean Society of Costume
    • /
    • v.36
    • /
    • pp.43-52
    • /
    • 1998
  • This study was to analyze properties of the foot form through a development figure of the surface area by factor analysis, cluster analysis, and reglation analysis. This study was performed 71 college women between 19 adn 23 years old residing in Pusan urban area. The result was as follows; 1. There are four factors selected by factor analysis. The 1st factor signifies the surface area of the toe. The 2nd factor signifies the surface area between Metatarsal circumfer-ence and Tarsal circumference. The 3rd factor signifies the surface area between Toe circumference and Metatarsal circumference. The 4th factor signifies the surface area between Heel-ankle circumference. 2. There are three clusters selected by fast cluster. Cluster 1 : The foot size, most parts of foot surface area and total foot surface area are relatively small to other clusters, but the surface area between Metatarsal circumference and Tarsal circumference is relatively large to other clusters. Cluster 2 : The foot size, all parts of foot surface area and total foot surface area are relatively large to other clusters as Cluster 1, but the surface area of the sole of the heel and the ankle is relatively large to other clusters. 3. Total surface area of the foot=-274.94+24.01* Foot lengh+9.28*Metatarsal circumference.

  • PDF

Surface Hardness Measurement of Anodic Oxide Films on AA2024 based an Ink-Impregnation Method

  • Moon, Sungmo;Rha, Jong-joo
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.2
    • /
    • pp.80-86
    • /
    • 2020
  • This paper is concerned with type of imperfections present within the anodic oxide films on AA2024 and surface hardness of the anodic film measured after ink-impregnation. The anodic oxide films were formed for 25 min at 40 mA/㎠ and 15±0.5℃ and 300 rpm of magnet stirring rate in 20% sulfuric acid solution. The ink-impregnation allows clear observations of not only the imperfections within the anodic oxide films but also an indentation mark on the oxide film surface made by a pyramidal-diamond penetrator for the hardness measurement. There were observed four different regions in the anodic oxide films on AA2024 and the surface hardness of the anodic oxide films appeared to be crucially dependent on the type of defects, showing 60~100 Hv on the oxide surface region I with large size black defect, 100~140 Hv on the oxide surface region II with large size grey defect, 140~170 Hv on the oxide surface region III with mall size black and/or grey defects and 170~190 Hv on the oxide surface region IV without defects. The pyramidal indentation marks were observed to be distorted in the regions with a large size black and grey defects, while no distortion of the indentation mark was observed in the regions with small size defects and without visible defects.

Comparison of Machinability Between PCD Tool and SCD Tool for Large Area Mirror Surface Machining Using Multi-tool by Planer (평삭공정에서 경면가공을 위한 단결정 및 다결정 다이아몬드 다중공구의 가공성 평가)

  • Kim, Chang-Eui;Choi, Hwan-Jin;Jeon, Eun-Chae;Je, Tae-Jin;Kang, Myung-Chang
    • Journal of Powder Materials
    • /
    • v.20 no.4
    • /
    • pp.297-301
    • /
    • 2013
  • Mirror surface machining for large area flattening in the display field has a problem such as a tool wear and a increase in machining time due to large area machining. It should be studied to decrease machining time and tool wear. In this paper, multi-tool machining method using a PCD tool and a SCD tool was applied in order to decrease machining time and tool wear. Machining characteristics (cutting force, machined surface and surface roughness) of PCD tool and SCD tool were evaluated in order to apply PCD tool to flattening machining. Based on basic experiments, the PCD/SCD multi-tool method and the SCD single-tool method were compared through surface roughness and machining time for appllying large area mold machining.

Scanning Electron Microscopic Study of the Effects of Citric Acid on the Change of Implant Surface According to Application Time (구연산의 적용시간에 따른 임플란트 표면변화에 대한 주사전자현미경적 연구)

  • Song, Woo-Seok;Kwon, Young-Hyuk;Lee, Man-Sup;Park, Joon-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.4
    • /
    • pp.697-709
    • /
    • 2002
  • The present study was performed to evaluate the effect of citric acid on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, titanium plasma-sprayed surface, and sand-blasted, large grit, acid etched surface were utilized. Implant surface was rubbed with pH 1 citric acid for $\frac{1}{2}$ min., 1 min., 1 $\frac{1}{2}$ min., 2 min., and 3min, respeaively in the test group and implant surface was not treated in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In titanium plasma-sprayed surfaces, round or amorphous particles were deposited irregularly. The irregularity of titanium plasma-sprayed surfaces conditioned with pH 1 citric acid was lessened and the cracks were increased relative to the application time of pH 1 citric acid. 3. Sand-blasted, large grit, acid etched surfaces showed the macro/micro double roughness. The application of pH 1 citric acid didn't change the characteristics of the sand-blasted, large grit, acid etched surfaces. In conclusion, the application of pH 1 citric acid to titanium plasma-sprayed surface is improper. And pure titanium machined surface implants and sand-blasted, large grit, acid etched surface implants can he treated with pH 1 citric acid for peri-implantitis treatment if the detoxification of these surfaces could be evaluated.

Fabrication of Elliptical Micro-lens Array with Large Surface Using ${\mu}SL$ (마이크로광조형을 이용한 대면적의 타원형 마이크로 렌즈 어레이 제작)

  • Park, In-Baek;Lee, Su-Do;Kwon, Tae-Wan;Choi, Jae-Won;Lee, Seok-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.2
    • /
    • pp.123-130
    • /
    • 2008
  • A 3D structure production method for microstereolithography is a useful way that produces complex structures with flexible processes and low cost. Several UV curable resins were blended and the optimal resin for micro-lens fabricate was selected through viscosity, workability and transmission tests. It consists of 1, 6 - Hexanediol diacrylate with 15 Apha and Isobornyl acrylate for reducing some shrinkage. When fabricating a micro-lens array on large surface, some distortion of shape occurred because of the surface tension between cured part. To overcome this problem, the optimal processing conditions were derived from considering amount of the resin and surface tension. Large surface Micro-lens array, which are a type of elliptical convex and consist of 18,000 micro-lens in the range of 2cm*2cm were fabricated. The focal length to the X-axis and Y-axis were calculated. To verify the performance, measure an energy distribution of transmitted light from the Large surface Micro-lens array.

Anodic Growth of Large Inner Diameter TiO2 Nanotubes (TiO2 나노튜브 내경 확장을 위한 양극산화 조건)

  • Lee, Hyeon-Kwon;Oh, Hyunchul;Lee, Kiyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.1
    • /
    • pp.27-33
    • /
    • 2018
  • In the present work, we demonstrate the feasibility to form large inner diameter $TiO_2$ nanotubes by anodization of Ti in a HF/ethylene glycol electrolyte. In order to achieve the large inner diameter $TiO_2$ nanotubes, optimization of the anodization condition is required. We discover the key factors in the formation of large inner diameter $TiO_2$ nanotubes are concentration of water in the electrolyte, anodization temperatures, and high-applied potential. Under optimum conditions, the inner diameters of $TiO_2$ nanotubes are 379 nm. The results are approximately 3 folders larger than the general case.

Characteristic of Mirror Surface ELID Grinding of Large Scale Diametrical Silicon Wafer with Rotary Type Grinding Machine (로타리 연삭에 의한 대직경 Si-wafer의 ELID 경면 연삭특성)

  • 박창수;김원일;이윤경;왕덕현;김경년
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.660-665
    • /
    • 2002
  • Mirror surface finish of Si-wafers has been achieved by rotary in-feed machining with cup-type wheels in ELID grinding. But the diameter of the workpiece is limited with the diameter of grinding wheel in the in-feed machining method. In this study, grinding experiments by the rotary surface grinding machine with straight type wheels ware conducted, by which the possible grinding area of the workpiece is independent of the diameter of the wheels. For the purpose of investigating the grinding characteristics of large scale diametrical silicon wafer, grinding conditions such as rotation speed of grinding wheels and revolution of workpieces are varied, and grinding machine used in this experiment is rotary type surface grinding n/c equipment with an ELID wit. The surface ground using the SD8000 wheels showed that mirror like surface roughness can be attained near 2 - 6 nm in Ra.

  • PDF

Structural Characteristic Analysis of an Ultra-Precision Machine for Machining Large-Surface Micro-Features (초정밀 대면적 미세 형상 가공기의 구조 특성 해석)

  • Kim, Seok-ll;Lee, Won-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.12
    • /
    • pp.1173-1179
    • /
    • 2007
  • In recent years, research to machine large-surface micro-features has become important because of the light guide panel of a large-scale liquid crystal display and the bipolar plate of a high-capacity proton exchange membrane fuel cell. In this study, in order to realize the systematic design technology and performance improvements of an ultra-precision machine for machining the large-surface micro-features, a structural characteristic analysis was performed using its virtual prototype. The prototype consisted of gantry-type frame, hydrostatic feed mechanisms, linear motors, brushless DC servo motor, counterbalance mechanism, and so on. The loop stiffness was estimated from the relative displacement between the tool post and C-axis table, which was caused by a cutting force. Especially, the causes of structural stiffness deterioration were identified through the structural deformation analysis of sub-models.