• 제목/요약/키워드: Large-scale research facility

검색결과 147건 처리시간 0.023초

소규모 폐수배출시설 관리 강화의 필요성 (Necessity of Strengthening Small-Scale Wastewater Discharge Facilities Management)

  • 박재홍;류덕희
    • 한국물환경학회지
    • /
    • 제34권2호
    • /
    • pp.226-233
    • /
    • 2018
  • Small-scale wastewater discharge facilities account for 98% of all workplaces, but in the generation and emission of major pollutants, they account for 27.5 % and 23.5 %, respectively. Since the proportion of the emission load of the small-scale workplace is not large, the national environmental policy has been established mainly around large-scale wastewater discharge facilities. However, in the case of specific hazardous substances in water, the amount of the discharge load of the small-scale wastewater discharge facility was 2.4 times higher than that of the generation load. Certain types of specific hazardous substances in water, which have a higher discharge load than large-scale wastewater discharge facilities, account for 24 ~ 32 %. There are also cases in which the discharge load from a small-scale discharge facility is more than four times higher, depending on the specific kind of water pollutant. As a result of inspections, the violation rate of the small-scale wastewater discharge facility among the total violations by facilities is 93.9 ~ 97.5 %. As a result, the ecotoxicity value of small-scale wastewater discharge facilities was high in most industries, and there was a fluctuation in the measured value. This indicates that the ecological integrity of the water system can be largely influenced by small-scale wastewater discharge facilities. Therefore, it is necessary to expand the environmental management of small-scale wastewater discharge facilities, and in some cases, the effect of the improvement in quality may be more significant than in the management of large-scale wastewater discharge facilities.

Development of the Control System for Fast-Responding Frequency Regulation in Power Systems using Large-Scale Energy Storage Systems

  • Lim, Geon-Pyo;Park, Chan-Wook;Labios, Remund;Yoon, Yong-Beom
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.9-13
    • /
    • 2015
  • Energy storage systems (ESS) can be used to provide frequency regulation services in a power system to replace traditional frequency regulation power plants. Battery ESS, in particular, can provide "fast-responding frequency regulation," wherein the facility can respond immediately and accurately to the frequency regulation signal sent by the system operator. This paper presents the development and the trial run results of a frequency regulation control system that uses large-scale ESS for use in a large power system. The control system was developed initially for the 4 MW ESS demonstration facility in Jocheon Jeju Island, and was further developed for use in the 28 MW ESS facility at the Seo-Anseong substation and the 24 MW ESS facility at the Shin-Yongin substation to provide frequency regulation services within mainland Korea. The ESS facility in Seo-Anseong substation responds to a sudden drop in frequency via governor-free control, while the ESS facility in Shin-Yongin responds via automatic generator control (AGC).

Design of large-scale sodium thermal-hydraulic integral effect test facility, STELLA-2

  • Lee, Jewhan;Eoh, Jaehyuk;Yoon, Jung;Son, Seok-Kwon;Kim, Hyungmo
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3551-3566
    • /
    • 2022
  • The STELLA program was launched to support the PGSFR development in 2012 and for the 2nd stage, the STELLA-2 facility was designed to investigate the integral effect of safety systems including the comprehensive interaction among PHTS, IHTS and DHRS. In STELLA-2, the long-term transient behavior after accidents can be observed and the overall safety aspect can also be evaluated. In this paper, the basic design concept from engineering basis to specific design is described. The design was aimed to meet similarity criteria and requirements based on various non-dimensional numbers and the result satisfied the key features to explain the reasoning of safety evaluation. The result of this study was used to construct the facility and the experiment is on-going. In general, the final design meets the similarity criteria of the multidimensional physics inside the reactor pool. And also, for the conservation of natural circulation phenomena, the design meets the similarity requirements of geometry and thermo-dynamic behavior.

실대형화재평가장치의 개발 및 안정화에 관한 연구 (The Study of Development and Calibration for the Real Scale Fire Test Facility)

  • 유용호;김흥열;신현준
    • 한국화재소방학회논문지
    • /
    • 제22권1호
    • /
    • pp.37-44
    • /
    • 2008
  • 최근 화재와 관련된 연구가 활발해지면서 축소모형실험 등을 통한 연구가 진행되어 왔다. 그러나 실물화재 실험과의 직접적인 상관관계를 설명하기에는 충분하지 못하기 때문에 실물화재에 대한 관심이 증가되어 왔다. 따라서 본 연구에서는 산소소모율법을 적용한 10 MW급 라지스케일로리미터를 개발하였으며, 헵탄 풀 화재를 이용한 발열량 보정을 수행하였다. 그 결과 신뢰성 높은 보정결과를 얻었으며, 보다 진보적인 실물화재연구에 적용할 수 있음을 확인할 수 있었다.

Design considerations for teleoperation systems operating in gas-tight argon cells

  • Yu, Seungnam;Lee, Jongkwang;Park, Byungsuk;Cho, Ilje;Lee, Hyojik
    • Nuclear Engineering and Technology
    • /
    • 제49권8호
    • /
    • pp.1717-1726
    • /
    • 2017
  • In the nuclear industry, mechanical engineers spend a significant portion of their time designing equipment such as manipulators, bogies, mechanical grippers, and so on. Some customized designs can be considered as standard mechanical equipment in this area, although it is not unusual to find that an existing design cannot simply be copied from one project to another. Varied performance requirements can dictate that redesign, often quite extensive redesign, is required. However, if something similar has been done before, engineers could use that as a starting point for the new project. In this regard, this study presents several guidelines inspired by previous design knowledge for similar development cases. Moreover, this study presents more detailed suggestions such as design guidelines for an argon-based hot cell atmosphere and design experience for a large-scale practical hot cell facility. Design considerations and case studies dealt with in this study are dedicated to teleoperation manipulators that are used at a large-scale argon cell facility for pyroprocess integrated inactive demonstration (PRIDE), at the Korea Atomic Energy Research Institute. In particular, for case studies to support the suggested recommendations, a fabricated telemanipulator system for PRIDE is introduced, and several kinds of experimental results associated with it are presented.

제주시 대규모 초등학교의 특별교실 실태에 관한 연구 (A Study on the Actual Conditions of Special Classes for the Large-scale Elementary schools in jeju)

  • 이은경;박정근
    • 한국농촌건축학회논문집
    • /
    • 제16권1호
    • /
    • pp.43-52
    • /
    • 2014
  • Education is about sharing knowledge and using techniques and skills that can person's ability. the goal is to educate and develop people as a whole. In order to achieve this educational purpose efficiently, our society has many educational courses. The educational facility which can be used in a variety of educational methods should be made flexible. It should provide an environment in which ever student can grow. Being creative, using a variety of methods should help to develop character in people. In order to achieve this, the school's facilities should be future-oriented. It is necessary to research systemically about its changes and feed back according to the social demand, the educational purpose, and the changes of educational courses. This study is intended to present basic material which will be need from now on for the facility of the special classes in jeju city. Elementary schools should consider having a reasonable scale and arrangement pattern. The facility for special classes has to find a way to operate flexibly according to the changes of the class number.

SAMPLING BASED UNCERTAINTY ANALYSIS OF 10 % HOT LEG BREAK LOCA IN LARGE SCALE TEST FACILITY

  • Sengupta, Samiran;Dubey, S.K.;Rao, R.S.;Gupta, S.K.;Raina, V.K
    • Nuclear Engineering and Technology
    • /
    • 제42권6호
    • /
    • pp.690-703
    • /
    • 2010
  • Sampling based uncertainty analysis was carried out to quantify uncertainty in predictions of best estimate code RELAP5/MOD3.2 for a thermal hydraulic test (10% hot leg break LOCA) performed in the Large Scale Test Facility (LSTF) as a part of an IAEA coordinated research project. The nodalisation of the test facility was qualified for both steady state and transient level by systematically applying the procedures led by uncertainty methodology based on accuracy extrapolation (UMAE); uncertainty analysis was carried out using the Latin hypercube sampling (LHS) method to evaluate uncertainty for ten input parameters. Sixteen output parameters were selected for uncertainty evaluation and uncertainty band between $5^{th}$ and $95^{th}$ percentile of the output parameters were evaluated. It was observed that the uncertainty band for the primary pressure during two phase blowdown is larger than that of the remaining period. Similarly, a larger uncertainty band is observed relating to accumulator injection flow during reflood phase. Importance analysis was also carried out and standard rank regression coefficients were computed to quantify the effect of each individual input parameter on output parameters. It was observed that the break discharge coefficient is the most important uncertain parameter relating to the prediction of all the primary side parameters and that the steam generator (SG) relief pressure setting is the most important parameter in predicting the SG secondary pressure.

경기도 한북정맥 훼손유형 연구 (The Study on Damaged Hanbuk Mountain Range in Gyeonggi-Do)

  • 서정영;이양주
    • 한국환경복원기술학회지
    • /
    • 제13권4호
    • /
    • pp.65-74
    • /
    • 2010
  • This study is for Hanbuk Mountain Range within Gyeonggi province which is to propose the conservation plan by each damage pattern through site survey of the mountain range. The damage patterns are classified by siding, pointing and lining. The total damaged area is 103 areas: The siding pattern is damaged by developing farmland, mineral and quarry mining, dam, large scale development complex and cemetery park; The pointing pattern is including the development of road, transmission tower and way and mountaineering trail; The construction of electricity and communication facility, military facility, mobile communication station, heliport and shelter. The damages by developing road and large scale development complex are the most cause, and military facility, dam and reservoir, and residential area are the main causes, respectively. One of the compromised situation Hanbuk-Mountain Range usage as per section 7 section (18.45%), 12 section (18.45%) is the largest number of compromised has been surveyed, undermine the situation if you look at the usage by the road 25 locations (24.22%), military facilities and dam and reservoir to undermine this 11 established respectively (10.68%) were the most undermine. Therefore, this research propose the conservation plan as follow: first, need to understand, educate and publicize on Hanbuk-Mounatin Range; second, manage through the regulations and ordinance of Gyeonggi province; third build and expand the law for protecting Baekdu-Great Mountain Range.

Effects of Physical Environment on Quality of Life among Residents with Dementia in Long-Term Care Facilities in Canada and Sweden: A longitudinal study in a large-scale institutional setting versus a small-scale homelike setting

  • Lee, Sook Young;Hung, Lillian;Chaudhury, Habib;Morelli, Agneta
    • Architectural research
    • /
    • 제23권2호
    • /
    • pp.19-28
    • /
    • 2021
  • Reduction in competence makes older adults with dementia more sensitive to the influence of the physical environment. The aim of the longitudinal study was to examine whether residents with dementia in long-term facilities with variability in physical environmental characteristics in Vancouver (N= 11), Canada and Stockholm (N=13), Sweden had a difference in their quality of life (QoL). QoL was assessed using Dementia Care Mapping tool three times over one year for the reliability of data. The results of the study demonstrated that the residents with dementia living in a homelike and positive stimulating setting showed less withdrawn behaviors and a higher level of well-being compared to those in a large-scale institutional setting. This study also found that the residents living in a large-scale institutional environment spent more monotonous times than the other groups, which may be to provision of fewer structured activity programs or less social interaction with neighbors or staff members. Residents living in a large-scale institutional setting in Canada showed so far as five times more agitated/ distressed behaviors and twice more withdrawal compared to the ones living in a small-scale homelike setting in Sweden. The study supports that the large-scale institutional environment was considerably associated with levels of lower quality of life among the residents with dementia.