• Title/Summary/Keyword: Large-current

Search Result 5,209, Processing Time 0.047 seconds

Performance Improvement of Protective Relaying for Large Transformer by Using Voltage-Current Trend and Flux-Differential Current Slope Characteristic (전압-전류 추이와 자속-차전류 기울기 특성을 이용한 변압기 보호계전기법의 성능 개선)

  • Park, Chul-Won;Park, Jae-Sae;Jung, Yun-Man;Ha, Kyung-Jae;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.43-50
    • /
    • 2004
  • Percentage differential characteristic relaying(PDR) has been recognized as the principal basis for power transformer protection. Second harmonic restraint PDR has been widely used for magnetizing inrush in practice. Nowadays, relaying signals can contain 2nd harmonic component to a large extent even in a normal state, and 2nd harmonic ratio indicates a tendency of relative reduction because of the advancement of material. Further, as the power system voltage becomes higher and more underground cables are used, larger 2nd harmonic component in the differential current under internal fault is observed. And then, conventional 2nd harmonic restraint PDR exposes some doubt in reliability. It is, therefore, necessary to develop a new algorithm for performance improvement of conventional protective relaying. This paper proposes an advanced protective relaying algorithm by using voltage-current trend and flux-differential current slope characteristic. To evaluate the performance of the proposed algorithm, we have made comparative studies of PDR, fuzzy relaying and DWT relaying. The paper is constructed power system model including power transformer, utilizing the WatATP, and data collection is made through simulation of various internal faults and inrush. As the results of test, the new proposed algorithm was proven to be faster and more reliable.

Estimated Advection Heat in the East/Japan Sea

  • Han, In-Seong;Kang, Yong-Q;Kim, Bok-Kee;Seong, Ki-Tack
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.165-170
    • /
    • 2003
  • A significant surface net heat loss appears around the Kuroshio and the Tsushima Warm Current regions. The area where the surface heat loss occurs should require heat to be supplied by the current to maintain the long-term annual heat balance. Oceanic heat advection in these regions plays an important role in the heat budget. The spatial distribution of the heat supply by the Tsushima Warm Current near the surface was examined by calculating the horizontal heat supply in the surface layer of the East/Japan Sea, directly from historical sea surface temperature and current data. We have also found a simple estimation of the effective vertical scale of heat supply by the current to compensate net heat loss using the heat supplied by the current in the surface 10m layer. The heat supplied by the current for the annual heat balance was large in the Korea/Tsushima Strait and along the Japanese Coast, and was small in the northwestern part of the East/Japan Sea. The amount of heat supplied by the current was large in the northwestern part and small in the southeastern part of the East/Japan Sea. These features suggest that the heat supplied by the Tsushima Warm Current is restricted to near the surface around the northeastern part and extends to a deeper layer around the southeastern part of the East/Japan Sea.

  • PDF

Eddy current loss calculation of flux shield in the large turbo generator using axi-periodic analysis (Axi-periodic Analysis를 이용한 대형 터보 발전기 단부 Flux Shield의 Eddy Current Loss 산정)

  • Kwon, Soon-O;Lee, Jung-Jong;Hong, Jung-Pyo;Nam, Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.987-989
    • /
    • 2005
  • Axi-periodic analysis using magnetic vector potential is formulated in time harmonic field and applied to the field analysis for the end region of large turbo generator in this paper. By using axi-periodic analysis, the effect of flux shield, one of the structure placed in the end region of large turbo generator to prevent stator end from thermal damage, is studied, and eddy current loss in the flux shield is estimated for operation conditions. 3D FEA is used for the verification of presented analysis method. Because 3D flux distribution can be calculated with 2D modeling, magnetic field showing 3D distribution can be effectively calculated by axi-periodic analysis comparing with 3D FEA.

  • PDF

Characteristics of a 190 kVA Superconducting Fault current Limiting Element (190 kVA급 초전도한류소자의 특성)

  • Ma, Y.H.;Li, Z.Y.;Park, K.B.;Oh, I.S.;Ryu, K.Y.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.37-42
    • /
    • 2007
  • We are developing a 22.9 kV/25 MVA superconducting fault current limiting(SFCL) system for a power distribution network. A Bi-2212 bulk SFCL element, which has the merits of large current capacity and high allowable electric field during fault of the power network, was selected as a candidate for our SFCL system. In this work, we experimentally investigated important characteristics of the 190 kVA Bi-2212 SFCL element in its application to the power grid e.g. DC voltage-current characteristic, AC loss, current limiting characteristic during fault, and so on. Some experimental data related to thermal and electromagnetic behaviors were also compared with the calculated ones based on numerical method. The results show that the total AC loss at rated current of the 22.9 kV/25 MVA SFCL system, consisting of one hundred thirty five 190 kVA SFCL elements, becomes likely 763 W, which is excessively large for commercialization. Numerically calculated temperature of the SFCL element in some sections is in good agreement with the measured one during fault. Local temperature distribution in the190 kVA SFCL element is greatly influenced by non-uniform critical current along the Bi-2212 bulk SFCL element, even if its non-uniformity becomes a few percentages.

Measurement of HTS Stacked Tapes Properties under Over-Current Condition in External Magnetic Field (외부자계 인가시 적층 고온초전도선재의 과전류 통전특성 측정)

  • Lee, K.Y.;Lim, H.W.;Lee, H.J.;Cha, G.S.;Lee, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.909-911
    • /
    • 2002
  • Rises of current level at power applications, such as transformer, motor, power cable need for using stacked HTS tapes. In this paper, we measured rises of temperature and tap voltage in 4-stacked HTS tapes under over-current condition. We measured 4-stacked HTS tapes properties under over-current condition with a little temperature rise as well as a large temperature rise. Rises of temperature and tap voltage are measured by using E-type thermocouples and voltage taps, respectively. According to the results of measurement, rises of tap voltage under over-current condition with a large temperature rises depends on rises of temperature.

  • PDF

Analysis and Reduction Methods of Sheath Circulating Current in Underground Transmission Systems (지중송전계통에서 시스순환전류 해석 및 저감방안)

  • Jeong, Chae-Gyun;Lee, Jong-Beom;Gang, Ji-Won;Jang, Tae-In
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.11
    • /
    • pp.537-545
    • /
    • 2001
  • This paper describes the analysis of sheath circulating current and various methods to reduce the large circulating current in case of operating cable system using EMTP/ATPDraw. And also, possible methods are proposed through a detailed analysis regarding cable systems by considering various electrical and environmental factors. It is evaluated that the proposed reduction methods can be effectively applied to reduce the large sheath circulating over current with the minimized electrical problems.

  • PDF

Applications of Current Limiting Diode to Chip on Board Type Light Source and Lighting Equipment Circuits (정전류다이오드를 이용한 COB 타입 LED 광원 및 조명기기 회로)

  • Park, Hwa Jin;Yu, S.J.;Park, Jong Min;Kim, Y.J.
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.488-492
    • /
    • 2013
  • Current limiting diode (CLD) was fabricated using junction field effect transistor (JFET) structured two small cells and eight large cells. Two small cells and eight large cells were connected in parallel and the obtained constant current was 110 mA. The application of CLD in each of the parallel circuits on chip on board (COB) type LED lighting source, could significantly reduce the current deviation within the parallel circuits. The applications of CLD on AC power small lighting source, battery power low voltage parallel lighting source and AC flat lighting source were investigated.

Hot-Carrier Induced GIDL Characteristics of PMOSFETs under DC and Dynamic Stress (직류 및 교류스트레스 조건에서 발생된 Hot-Carrier가 PMOSFET의 누설전류에 미치는 영향)

  • 류동렬;이상돈;박종태;김봉렬
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.12
    • /
    • pp.77-87
    • /
    • 1993
  • PMOSFETs were studied on the effect of Hot-Carrier induced drain leakage current (Gate-Induced-Drain-Leakage). The result turned out that change in Vgl(drain voltage where 1pA/$\mu$m of drain leadage current flows) was largest in the Channel-Hot-Hole(CHH) injection condition and next was in dynamic stress and was smallest in electron trapping (Igmax) condition under various stress conditions. It was analyzed that if electron trapping occurrs in the overlap region of gate and drain(G/D), it reduces GIDL current due to increment of flat-band voltage(Vfb) and if CHH is injected, interface states(Nit) were generated and it increases GIDL current due to band-to-defect-tunneling(BTDT). Especially, under dynamic stress it was confirmed that increase in GIDL current will be high when electron injection was small and CHH injection was large. Therefore as applying to real circuit, low drain voltage GIDL(BTDT) was enhaced as large as CHH Region under various operating voltage, and it will affect the reliablity of the circuit.

  • PDF

Measurement and Analysis of Sheath Circulating Current in Domestic Underground Transmission Cables (국내 송전 케이블 시스 순환전류 실측 및 분석)

  • 하체웅;김정년;이수길;김동욱;이종범;강지원
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.193-200
    • /
    • 2003
  • The use of underground transmission tables has continuously increased in densely inhabited urban and suburban area. Due to a increasing demand of underground cables, two or more circuits are installed in parallel for several kilometers. It, however, has not been realized that the sheath circulating current is generated in the system where a large number of cables are laid in the same route. In this paper, Author studied diversely the sheath circulating current on underground cables depending on the various length rate, the phase arrangement, and the grounding resistance of the sheath in the cross-bonded section. It was clear that very large circulating current is generated in cable systems due to unbalanced length rate and phase arrangement in the cross-bonded section.

Modeling and Improved Predictive Current Control for Buck-Boost Series Resonant Inverter

  • Moon, Gun-Woo;Lee, Jung-Hoon;Baik, In-Cheol;Kim, Kyeong-Hwa;Youn, Myung-Joong
    • Journal of Electrical Engineering and information Science
    • /
    • v.1 no.1
    • /
    • pp.51-57
    • /
    • 1996
  • An improved predictive current control technique for a zero current switched(ZCS) buck-boost series resonant inverter(SRI) is proposed to overcome the inherent disadvantages such as the uncontrollable large overshoot and the large current ripple. Using the proposed technique, four quadrant operations of the output voltage and current for an uninterrutible power supply(URS) application are guaranteed and the buck-boost operation can also be obtained without an additional bidirectional switch.

  • PDF