The Lightning Impulse Properties and Breakdown Voltage of Natural Ester Fluids Near the Pour Point

  • Choi, Sun-Ho;Huh, Chang-Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.524-529
    • /
    • 2013
  • Recently, researchers have become interested in natural ester fluids, as they are an environmentally friendly alternative to mineral oils. Natural ester fluids are a natural resource made from plants; they have higher biodegradability, flash, and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester fluids also have a higher pour point, viscosity, and water content. These characteristics can hamper circulation and impair the electrical properties of an oil-filled transformer. A large amount of data has been accumulated over the years in regards to mineral insulating oil involving dielectric breakdown voltage and lightning impulse tests. However, natural ester fluids have not had their electrical properties sufficiently characterized. In this paper, we present an investigation into the characteristics of the electrical discharge development in natural ester fluids and in an oil-filled transformer near the pour points. The experiment results show that the electrical properties decreased according to a decrease in the ambient temperature and freezing time. It was found that the pour point and water content of natural ester fluids have a significant effect on the electrical properties.

A New Phase Shift Full Bridge Converter with Serially Connected Two Transformers (직렬 연결된 두 개의 트랜스포머를 갖는 새로운 위상 천이 풀 브릿지 컨버터)

  • 구관본;김태성;문건우;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.5
    • /
    • pp.443-452
    • /
    • 2002
  • A new phase shift full bridge (PSFB) converter with serially connected two transformers for telecommunication equipments of several hundred watts is proposed. The main features of the proposed converter are a wide input voltage range, an easiness to meet the requirement for zero voltage switching (ZVS) condition at a light load, and a small output voltage ripple. Furthermore, the serially connected two transformers can replace both a main transformer and an output inductor since the two transformers act as not only a main transformer but an output inductor by turns. Therefore, there is no need to use an output inductor, then the proposed converter features high power density. A mode analysis, design equations through a large signal modeling, and experimental results are presented to verify the validity of the proposed converter.

A High Efficiency LLC Resonant Converter with Wide Operation Range using Adaptive Turn Ratio Transformer for a Li-ion Battery (변압기의 가변 턴비 기법을 통해 넓은 전압범위를 만족하는 리튬이온 배터리용 고효율 LLC 공진형 컨버터)

  • Han, Hyeong-Gu;Choi, Yeong-Jun;Kim, Rae-Young;Kim, Juyong;Cho, Jintae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.305-311
    • /
    • 2017
  • In this paper, the LLC resonant converter battery charger, using adaptive turn ratio scheme, is proposed to achieve high efficiency and wide range output voltage. The LLC converter high frequency transformer has an adaptively changed turn ratio by the auxiliary control circuitry. As a result, the optimal converter design with a large magnetizing inductance is easily achieved to minimize the conduction and the turn-off losses while providing widely regulated voltage gain capability to properly charge the Li-ion battery. The proposed converter operational principle and the optimal design considerations are illustrated in detail. Finally, several simulation results verify the proposed LLC resonant converter's effectiveness.

Statistical Lifetime Analysis for Large Electric Power Equipments using Failure Data (고장데이터를 이용한 대용량 전력설비 통계적 수명분석)

  • Kim, Jeong-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1605-1611
    • /
    • 2017
  • In this study, the characteristic lifetime of power facilities such as power transformers and GIS were investigated as the basis of power facility asset management. It is difficult to obtain the operation and failure data of the facilities in Korea. Therefore, the number of failures of the electric power facilities was calculated from the operation data and hazard rate shown in the overseas literatures, and the statistical analysis was performed using the Weibull distribution function. As a result of extracting and analyzing the data of the UK National Grid for power transformers, the characteristic lifetime (scale parameter) of 116.45 years was considered to be a very appropriate value for power transformer management and can be used as a comparative data of the analysis of the domestic transformers. As for the GIS, based on the Bays and Bay-Years data and the hazard rate according to the operation years of the 123kV GIS in Germany, it is found out that the characteristic lifetime of GIS is not so meaningful. It is necessary to decide a maintenance strategy and lifetime expectancy considering the characteristics of the design, materials and manufacturing process of GIS.

Measurement of HTS Stacked Tapes Properties under Over-Current Condition in External Magnetic Field (외부자계 인가시 적층 고온초전도선재의 과전류 통전특성 측정)

  • Lee, K.Y.;Lim, H.W.;Lee, H.J.;Cha, G.S.;Lee, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.909-911
    • /
    • 2002
  • Rises of current level at power applications, such as transformer, motor, power cable need for using stacked HTS tapes. In this paper, we measured rises of temperature and tap voltage in 4-stacked HTS tapes under over-current condition. We measured 4-stacked HTS tapes properties under over-current condition with a little temperature rise as well as a large temperature rise. Rises of temperature and tap voltage are measured by using E-type thermocouples and voltage taps, respectively. According to the results of measurement, rises of tap voltage under over-current condition with a large temperature rises depends on rises of temperature.

  • PDF

Transcutaneous Energy Transmission with Double Tuned Duty Cycle Control (양단 공진과 듀티 컨트롤을 이용한 1-2cm 공극을 통한 에너지 전달)

  • Kim, Chang-Gyun;Cho, Bo-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.486-488
    • /
    • 1996
  • A dc-dc converter which transfers l2-48W of power(regulated output voltage 24V) across a large, variable air gap(1-2cm) has been designed. This converter employs double resonance to compensate the large leakage inductance of the primary and secondary of the transcutaneous transformer. To maximize the effect of resonance, a constant frequency, duty cycle control method is used. The duty cycle control presents advantages over a frequency control in terms of increase in dc voltage gain and reduction of the primary current. The analysis and design procedure for the proposed scheme is presented and the performance result is simulated and verified experimentally.

  • PDF

High-Frequency Soft-Switching PWM DC-DC Power Converter for Low Voltage Large Current Applications

  • Muraoka Hidekazu;Sakamoto Kenya;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.198-202
    • /
    • 2001
  • This paper presents a novel prototype version of ZCS-PWM forward DC-DC power converter using power MOSFETs which is designed for application specific low voltage large current conversion operation. The soft-switching forward power converter with a high frequency isolated transformer link which can efficiency operate over wide load ranges under two conditions of ZCS as well as active voltage clamped switching is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

Development of 250kW Power Conditioning System for Large Scale Photovoltaic Power Plant (대규모 태양광 발전설비를 위한 전력변환기 개발)

  • Kang, Ho-Hyun;Jung, Hong-Ju;Kim, Wang-Mun;Suh, In-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.640-642
    • /
    • 2008
  • This paper presents the design, development and performance of a 250kW power conditioning system(PCS) for large scale photovoltaic power plant. The PV inverter consists of a three phase IGBT stack, L-C filter, transformer and HMI unit for monitoring. To verify the performance of the PV inverter a testing facility was designed and constructed to simulate the characteristics of the solar cell and grid.

  • PDF

The Electrical Properties of Pb$TiO_3$Family Ceramics as a Function of Poling Electric Field (Pb$TiO_3$계 세라믹스의 분극전계에 따른 전기적 특성)

  • 김성진;류주현;이수호;홍재일;사공건
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.259-262
    • /
    • 1998
  • PbTi $O_3$ family ceramics can be used for the piezoelectric transformer using thickness extensional vibration mode because it is a material with the large anisotropy between electromechanical coupling factors $k_{t}$ and $k_{p}$. However, PbTi $O_3$ family ceramics have a difficult poling condition on account of its large anisotrophy. In this study, the structural and piezoelectric properties of (P $b_{0.76}$ $Ca_{0.24}$)[ $Ti_{0.96}$(M $n_{1}$3/S $b_{2/3}$)$_{0.04}$] $O_3$ system ceramics were investigated as a function of poling voltage in order to find the best poling condition.ion.n.n.ion.n.

  • PDF

A Study on the Transient Characteristics in 765kV Untransposed Transmission Systems (765kV 비연가 송전계통 과도 특성에 관한 고찰)

  • 안용진;강상희
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.397-404
    • /
    • 2004
  • This paper describes a study of transient characteristics in 765kV untransposed transmission lines. As the 765(kV) system can carry bulk power, some severe fault on the system nay cause large system disturbance. The large shunt capacitance and small resistance of 765kv transmission line make various difficulties for its protection. These problems including current difference between sending and receiving terminals on normal power flow, low order harmonic current component in fault current and current transformer saturation due to the long DC time constant of the circuit etc. must be investigated and solved. The analysis of transient characteristics at sending terminal has been carried out for the single phase to ground fault and 3-phase short fault, etc. The load current, charging current in normal condition and line flows, fault current, THD(Total Harmonic Distortion) of harmonics, time constants have been analysed for the 765kV untransposed transmission line systems.