• Title/Summary/Keyword: Large steel plate

Search Result 271, Processing Time 0.021 seconds

Finite Element Analytical Study of Steel Plate and Dowel Bar Systems Designed for Damage Reduction of Non-Bearing Walls (비내력벽의 손상제어를 위한 Steel Plate와 Dowel Bar 이격시스템에 대한 유한요소해석)

  • Lim, Chang-Gue;Moon, Kyo Young;Lee, Hong-Seok;Kim, Sung Jig;Kim, Young Nam;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.123-130
    • /
    • 2020
  • Generally the non-bearing walls in apartment buildings in Korea are not considered as a lateral force resisting members for the design consideration. This engineering practice caused large crack damages and brittle fractures of the non-bearing walls when subjected to Pohang earthquakes in 2017 since those have not been designed for seismic loading. In this study, finite element analysis was conducted for slot type non-bearing wall connection system to reduce damages and concentrate damages to the designated damping device through separation from the structural wall members. Steel plate and dowel bar systems designed for the dissipation of seismic energies were modeled and analyzed to investigate the damage reductions. Finally, the test result and the analysis result were compared and verified.

Diagonal bracing of steel frames with multi-cable arrangements

  • Husem, Metin;Demir, Serhat;Park, Hong G.;Cosgun, Suleyman I.
    • Structural Engineering and Mechanics
    • /
    • v.59 no.6
    • /
    • pp.1121-1137
    • /
    • 2016
  • A large number of structure in the world were build with poor seismic details, with or without any lateral load resisting system like concentrically braced frames and steel plate shear walls. These structures can reveal deteriorating hysteretic behaviors with stiffness and strength degradation. Therefore, seismic retrofitting of such structures for drift control has vital importance. In this study a retrofit methodology has been developed, which involves diagonal bracing of steel frames with different cable arrangements. In the experimental and numerical program 5 different lateral load resisting system were tested and results compared with each other. The results indicated that multi-cable arrangements suggested in this study showed stable ductile behavior without any sudden decrease in strength. Due to the usage of more than one diagonal cable, fracture of any cable did not significantly affect the overall strength and deformation capacity of the system. In cable braced systems damages concentrated in the boundary zones of the cables and beams. That is why boundary zone must have enough stiffness and strength to resist tension field action of cables.

Experimental and Application Examples of Composite Beams Strengthened by Lower End Compression Member and Upper Tension Reinforcement (단부 하부 압축재와 상부 인장 철근으로 보강한 합성보의 실험 및 적용 사례 연구)

  • Oh, Jung-Keun;Shim, Nam-Ju
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.1
    • /
    • pp.83-91
    • /
    • 2019
  • The BX composite beam is designed to have the same cross-section regardless of the size of the momentum, which is a disadvantage of the existing steel structure. Combination of the H-beam end compressive material and the H-section steel tensile reinforcement according to the moment size in a single span, It is possible to say that it is an excellent synthesis which increases the performance. When underground and overhead structures are constructed, it is possible to reduce the bending, increase lateral stiffness, reduce construction cost, and simplify joints. The seamability of the joining part is a simple steel composite beam because of the decrease of the beam damping at the center of the beam and the use of the end plate of the new end compressing material. In the case of structures with long span structure and high load, it is advantageous to reduce the material cost by designing large steel which is high in price at less than medium steel.

Prediction of the welding distortion of large steel structure with mechanical restraint using equivalent load methods

  • Park, Jeong-ung;An, Gyubaek
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.3
    • /
    • pp.315-325
    • /
    • 2017
  • The design dimension may not be satisfactory at the final stage due to the welding during the assembly stage, leading to cutting or adding the components in large structure constructions. The productivity is depend on accuracy of the welding quality especially at assembly stage. Therefore, it is of utmost importance to decide the component dimension during each assembly stage considering the above situations during the designing stage by exactly predicting welding deformation before the welding is done. Further, if the system that predicts whether welding deformation is equipped, it is possible to take measures to reduce deformation through FE analysis, helping in saving time for correcting work by arresting the parts which are prone to having welding deformation. For the FE analysis to predict the deformation of a large steel structure, calculation time, modeling, constraints in each assembly stage and critical welding length have to be considered. In case of fillet welding deformation, around 300 mm is sufficient as a critical welding length of the specimen as proposed by the existing researches. However, the critical length in case of butt welding is around 1000 mm, which is far longer than that suggested in the existing researches. For the external constraint, which occurs as the geometry of structure is changed according to the assembly stage, constraint factor is drawn from the elastic FE analysis and test results, and the magnitude of equivalent force according to constraint is decided. The comparison study for the elastic FE analysis result and measurement for the large steel structure based on the above results reveals that the analysis results are in the range of 80-118% against measurement values, both matching each other well. Further, the deformation of fillet welding in the main plate among the total block occupies 66-89%, making welding deformation in the main plate far larger than the welding deformation in the longitudinal and transverse girders.

A Study of Lamella Tearing being Produced by Corner Joint Welding in Box Column of Ultra Thick Plate (극후판 Box Column의 Corner Joint 용접시 발생하는 Lamella Tearing에 관한 연구)

  • Han-Sur Bang;Seong-Joo Kim;Jong-Myung Kim;Woong-Sung Jang;Young-Seob Kwon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.4
    • /
    • pp.95-104
    • /
    • 1999
  • Use of the ultra thick plate is being continuously increased in large off-shore structures, ships, bridges and skyscraper construction, due to increasingly large-sized steel structures and it seems that this trend will be maintained. But, occurrence of the lamella tearing has been reported in ultra thick plate used for construction. It is reportedly caused by impurities such S(sulfur), P(phosphorus) and others accumulated in the ultra thick plate's centerline in the thickness direction with strip shape or by restraint residual stress caused by the welding. In the ultra thick plate made by continuous casting method, occurrence of lamination is difficult to avoid because of the properties of production procedure. Therefore, with a view to reducing the lamella properties, this report tries tearing in the steel structure in the view of welding strength rather than metallic properties, this report tries to seek the optimum groove and welding procedure by using the computer simulation based on FEM(Finite Element Method).

  • PDF

An experimental study on the ballistic performance of FRP-steel plates completely penetrated by a hemispherical-nosed projectile

  • Chen, Changhai;Zhu, Xi;Hou, Hailiang;Zhang, Lijun;Shen, Xiaole;Tang, Ting
    • Steel and Composite Structures
    • /
    • v.16 no.3
    • /
    • pp.269-288
    • /
    • 2014
  • Experiments were carried out to investigate the ballistic performance of fiber reinforced plastic(FRP)-steel plates completely penetrated by hemispherical-nosed projectiles at sub-ordnance velocities greater than their ballistic limits. The FRP-steel plate consists of a front FRP laminate and a steel backing plate. Failure mechanisms and impact energy absorptions of FRP-steel plates were analyzed and compared with FRP laminates and single steel plates. The effects of relative thickness, manufacturing method and fabric type of front composite armors as well as the joining style between front composite armors and steel backing plates on the total perforation resistance of FRP-steel plates were explored. It is found that in the case of FRP-steel plates completely penetrated by hemispherical-nosed projectiles at low velocities, the failure modes of front composite armors are slightly changed while for steel backing plates, the dominate failure modes are greatly changed due to the influence of front composite armors. The relative thickness and fabric type of front composite armors as well as the joining style of FRP-steel plates have large effects whereas the manufacturing method of front composite armors has slight effect on the total perforation resistance of FRP-steel plates.

An Experimental Study on the Behavior of Steel Plate-Concrete Wall with Vertical Ribs (수직 보강된 SC 벽체의 거동에 대한 실험적 연구)

  • Lee, Seung Joon;Choi, Byong Jeong;Kim, Tae Kyoung
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.277-287
    • /
    • 2009
  • The objective of this study was to experimentally investigate the structural behavior of steel plate concrete walls with vertical ribs (SSC walls), to compare the experimental results with the currently applied evaluation equations, and to obtain information that would be useful in the development of design equations for SSC walls. SSC test specimens that were subjected to in plane shear forces and bending moments were fabricated and tested. The experimental results show that the effect of vertical ribs on the structural behavior of SSC walls may be neglected, and that the confinement effect of concrete on the steel plates on both sides of the walls was negligible. The comparison of the experimental results with the evaluation equations showed that the structural behavior of SSC walls under shear control is close to that of the evaluation equations, but that the behavior of SSC walls under larger bending moments is not very close to that of the evaluation equations. The current evaluation equations for USC walls may be applied to the design of SSC walls because the structural walls of nuclear power plants are not subjected to large in plane bending moments.

A Numerical Study for Deformation Characteristics of the Wearing Surface on a Steel Plate Deck under Wheel Loads (윤하중을 받는 강바닥판 교면포장의 변형특성에 대한 수치해석적 연구)

  • Kim, Hae-Na-Rae;Ock, Chang-Kwon;Kim, Moon-Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.4
    • /
    • pp.439-447
    • /
    • 2011
  • Longitudinal cracks due to traffic truck loadings that are caused by local deformations of steel orthotropic bridge decks are sometimes observed in the wearing surface. So, underlying causes of the longitudinal pavement crack induced by structural behaviors of steel decks are investigated in this study. For this purpose, The rational finite element model of the steel deck and the pavement having the box girder is developed and a parametric study is performed by varying thickness or elastic modulus ratios of both the steel deck plate and the pavement. As a result, a large tensile strain above the webs of the u-rib and the box girder, which becomes the main cause of the cracks of the pavement, is detected from variation of the normal strain component of the wearing surface in the transverse direction.

Fatigue Life Estimation Method Considering Traffic Properties for Steel Highway Girder Bridge (교통특성을 고려한 강도로교의 피로수명 평가 방안)

  • Lee, Hee-Hyun;Kyung, Kab-Soo;Jeon, Jun-Chang
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.3
    • /
    • pp.209-218
    • /
    • 2010
  • The fatigue phenomenon, which is induced by stress accumulation due to the repeated loading of vehicles in the long term, is one of the main factors of the span of life of a steel bridge. In this paper, the effects of traffic properties on the fatigue life of ordinary short- and medium-span steel plate girder bridges that are exposed to relatively large dynamic effects are investigated. From the analysis, it was known that the fatigue life of the bridge becomes shorter with increasing traffic volume and number of large vehicles, and is affected by the weights of the vehicles. Based on the analysis results, a new parameter that can represent the traffic property that affects the fatigue life of the subject bridge is suggested, and the validity of the parameter is confirmed.

Evaluation of Forming Performance of TMC Steel Pipes & Tubes for Building Structure (건축구조용 TMC 강관의 가공성능 평가)

  • Im, Sung Woo;Kim, Jong Seong;Chang, In Hwa
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.43-49
    • /
    • 2004
  • With building structures becoming higher and having longer spans, new structural steel with better strength, thicker plate, and performance may be required rather than conventional structural steel. TMC steel is widely used in building structures largely due to its excellent seismic performance, superior weldability, and design strength that is not affected by plate thickness. To make use of TMC steel in pipe structures with large diameter and heavy wall, however, the this study, the degradation of material properties in submerged are welded SM520TMC steel pipes and tubes was evaluated using variable fabrication process and material change. Degradation test results showed that the yield and ultimate strength increased and elongation decreased regardless of the mode of fabrication, i.e., through roll bending or press forming, or steel used, i.e., domestic SM520TMC steel or SM520TMC steel from Japan.