• Title/Summary/Keyword: Large optics

Search Result 352, Processing Time 0.025 seconds

Optical Design of Gradient-Index Objective for Optical Pickup (광 Pickup 용 Gradient-Index 대물렌즈 설계)

  • Park, In-Kyu;Lee, Jong-Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.4
    • /
    • pp.256-263
    • /
    • 2007
  • High NA objective design by using SELFOC materials was studied, and two kinds of objective for optical pick-up were designed. The SELFOC materials have radial gradient index distribution, and it gives additional degree of freedom in optical design. Therefore, we expect that optical design of high NA objective without aspheric surface will be possible. In this study, the variation of ms spot diameter was investigated as a function of quadratic constant and refractive index on axis for various combinations of axial thickness and entrance pupil diameter. For the survey, Code V was used for optimization and evaluation of the objective lenses. The result suggested that larger quadratic constant and higher refractive index on axis could give us better imaging performance for all combinations of axial thickness and pupil diameter. Based on the survey, we designed high NA objectives for DVR. There were two kinds of design solution consisting two spherical SELFOC lenses. The solution I had positive-positive lens configuration with short over-all-length, but it had poor off-axial performance compared with the solution II. The solution II had negative-positive lens configuration with good off-axial imaging performance. But the solution II had some disadvantages, long over-all-length and large diameter of the second lens.

Development of a Compact Desktop-sized Roll-to-roll Nanoimprinting System for Continuous Nanopatterning (데스크탑 규모의 간결한 롤투롤 나노임프린팅 기반 나노패턴 연속가공 시스템 개발)

  • Lee, Jeongsoo;Lee, Jihun;Nam, Seungbum;Cho, Sungil;Jo, Yongsu;Go, Minseok;Lee, Seungjo;Oh, Dong Kyo;Kim, Jeong Dae;Lee, Jae Hyuk;Ok, Jong G.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.1
    • /
    • pp.96-101
    • /
    • 2017
  • We have developed a compact desktop-sized nanopatterning system driven by the Roll-to-Roll (R2R) nanoimprinting (NIL) principle. The system realizes the continuous and high-speed stamping of various nanoscale patterns on a large-area flexible substrate without resorting to ponderous and complicated instruments. We first lay out the process principle based on continuous NIL on a UV-curable resin layer using a flexible nanopatterned mold. We then create conceptual and specific designs for the system by focusing on two key processes, imprinting and UV curing, which are performed in a continuous R2R fashion. We build a system with essential components and optimized modules for imprinting, UV curing, and R2R conveying to enable simple but effective nanopatterning within the desktop volume. Finally, we demonstrate several nanopatterning results such as nanolines and nanodots, which are obtained by operating the built desktop R2R NIL system on transparent and flexible substrates. Our system may be further utilized in the scalable fabrication of diverse flexible nanopatterns for many functional applications in optics, photonics, sensors, and energy harvesters.

A Study on the Dynamic Range Expansion of the Shack-Hartmann Wavefront Sensor using Image Processing (영상처리 기법을 이용한 샥-하트만 파면 센서의 측정범위 확장에 대한 연구)

  • Kim, Min-Seok;Kim, Ji-Yeon;Uhm, Tae-Kyung;Youn, Sung-Kie;Lee, Jun-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.375-382
    • /
    • 2007
  • The Shack-Hartmann wavefront sensor is composed of a lenslet array generating the spot images from which local slope is calculated and overall wavefront is measured. Generally the principle of wavefront reconstruction is that the spot centroid of each lenslet array is calculated from pixel intensity values in its subaperture, and then overall wavefront is reconstructed by the local slope of the wavefront obtained by deviations from reference positions. Hence the spot image of each lenslet array has to remain in its subaperture for exact measurement of the wavefront. However the spot of each lenslet array deviates from its subaperture area when a wavefront with large local slopes enters the Shack-Hartmann sensor. In this research, we propose a spot image searching method that finds the area of each measured spot image flexibly and determines the centroid of each spot in its area Also the algorithms that match these centroids to their reference points unequivocally, even if some of them are situated off the allocated subaperture, are proposed. Finally we verify the proposed algorithm with the test of a defocus measurement through experimental setup for the Shack-Hartmann wavefront sensor. It has been shown that the proposed algorithm can expand the dynamic range without additional devices.

Progress Report on NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Park, Sung-Joon;Park, Kwijong;Moon, Bongkon;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Youngsik;Kim, Il-Joong;Park, Won-Kee;Lee, Duk-Hang;Park, Chan;Ko, Kyeongyeon;Nam, Ukwon;Han, Wonyong;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.49.1-49.1
    • /
    • 2014
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) onboard NEXTSat-1 is the near-infrared instrument onboard NEXTSat-1 which is being developed by KASI. The imaging low-resolution spectroscopic observation in the near-infrared range for nearby galaxies, low background regions, star-forming regions and so on will be performed on orbit. After the System Requirement Review, the optical design is changed from on-axis to the off-axis telescope which has a wide field of view (2 deg. ${\times}$ 2 deg.) as well as the wide wavelength range from 0.95 to $3.8{\mu}m$. The mechanical structure is considered to endure the launching condition as well as the space environment. The design of relay optics is optimized to maintain the uniform optical performance in the required wavelength range. The stray light analysis is being made to evade a light outside a field of view. The dewar is designed to operate the infrared detector at 80K stage. From the thermal analysis, we confirmed that the telescope can be cooled down to around 200K in order to reduce the large amount of thermal noise. Here, we report the current status of the NISS development.

  • PDF

3D Precision Measurement of Scanning Moire Using Line Scan Camera (라인스캔 카메라를 이용한 3차원 정밀 측정)

  • Kim, Hyun-Ju;Yoon, Doo-Hyun;Kim, Hak-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.5
    • /
    • pp.376-380
    • /
    • 2008
  • This paper presents the Projection Moire method using a line scan camera. The high resolution feature of a line scan camera makes it possible to scan an image quickly, thus enabling a much quicker 3D profile. This method uses a high resolution line scan camera making it possible to scan an image at high speed simultaneously measuring the 3D profile of a large FOV. When using a high resolution scan camera, a full FOV is scanned, thus requiring just one movement of a projection grating. As a result, the number of grating movements is reduced drastically. The end result is a faster and more accurate 3D measurement. Moving the grating too quickly causes vibration in the imaging system, which will normally be required to apply a stitching technique when using an area scan camera. However the technique is not required when using a line scan camera. Compared with the previous techniques, it has the advantages of simple hardware without moving mechanical parts - single exposure for obtaining three-dimensional information. A method using a high resolution line scan camera can be used in mass production to measure the bump height of wafers or the bump height of package substrates.

The Spermatogenesis of Cichlasoma managuensis, Cichlidae, Teleost (경골어류 시클리드과 Cichlasoma managuensis의 정자형성과정)

  • Lee, Kyu-Jae;Chang, Byung-Soo;Teng, Yung-Chien;Kim, Seok;Song, Mi-Sook;Joo, Kyung-Bok;Kim, Dong-Heui
    • Applied Microscopy
    • /
    • v.39 no.3
    • /
    • pp.219-226
    • /
    • 2009
  • The ultrastructure of spermatogenesis and sperm in Cichlasoma managuensis belonging to Cichlidae was investigated by light and electron microscopes. The testis of C. managuensis contained numerous testicular cysts, and spermatogenesis was synchronized in these testicular cysts. In the case of spermatogonia, the nucleus was comparatively large ellipsoidal, and mitochondria showed a marked development. The size of primary spermatocyte was smaller than that of spermatogonia, and that of secondary spermatocyte was smaller than that of primary spermatocyte. The chromatin of spermatocyte was highly condensed according to their development. The nucleus with electron-dense was round shape. In spermiogenesis, flagella started to be formed and chromatin was more condensed. The mitochondria were rearranged in a middle piece. The sperm was formed by loss of cytoplasm. The head of mature sperm was a spherical shape and had not acrosome. The microtubules of flagella were arranged 9+2 structure. Also, the tail of sperm have lateral fins.

Fiber-optic Mach-Zehnder Interferometer for the Detection of Small AC Magnetic Field (미소 교류 자기장 측정을 위한 Mach-Zehnder 광섬유 간섭계 자기센서 특성분석)

  • 김대연;안준태;공홍진;김병윤
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.139-148
    • /
    • 1991
  • A fiber-optic magnetic sensor system for the detection of small ac magnetic field(200Hz-2 kHz) was constructed. Magnetic field sensing part was fabricated by bonding a section of optical fiber to amorphous metallic glass(2605SC) having large magnetostriction effect. And with the directional coupler, all fiber type Mach-Zehnder interferometer was constructed to measure the variation of the external magnetic field by translating it into the optical phase shift in the interferometer. The signal fading problem of the interferometer, which is due to random phase drifts originated from the environment, i.e., temperature fluctuation, vibrations, etc., was elliminated by feedback phase compensation. This allows the sensitivity to be maintained at the maximum by keeping the interferometer in quadrature phase condition. The frequency response of metallic glass was found to be nearly flat in the range of 90 Hz-2 kHz and dc bias field for the maximum ac response was 3.5 Oe. The interferometer output showed good linearity over the range $\pm$0.5 Oe. For 1 kHz ac magnetic field the scale factor S and the minimum detectable magnetic field were measured to be 8.0 rad/Oe and $3X10^{-6} Oe/\sqrt{Hz}$at 1 Hz detection bandwidth respectively.

  • PDF

Photoemission Electron Micro-spectroscopic Study of the Conductive Layer of a CVD Diamond (001)$2{\times}1$ Surface

  • Kono, S.;Saitou, T.;Kawata, H.;Goto, T.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.7-8
    • /
    • 2010
  • The surface conductive layer (SCL) of chemical vapor deposition (CVD) diamonds has attracting much interest. However, neither photoemission electron microscopic (PEEM) nor micro-spectroscopic (PEEMS) information is available so far. Since SCL retains in an ultra-high vacuum (UHV) condition, PEEM or PEEMS study will give an insight of SCL, which is the subject of the present study. The sample was made on a Ib-type HTHP diamond (001) substrate by non-doping CVD growthin a DC-plasma deposition chamber. The SCL properties of the sample in air were; a few tens K/Sq. in sheet resistance, ${\sim}180\;cm^2/vs$ in Hall mobility, ${\sim}2{\times}10^{12}/cm^2$ in carrier concentration. The root-square-mean surface roughness (Rq) of the sample was ~0.2nm as checked by AFM. A $2{\times}1$ LEED pattern and a sheet resistance of several hundreds K/Sq. in UHV were checked in a UHV chamber with an in-situ resist-meter [1]. The sample was then installed in a commercial PEEM/S apparatus (Omicron FOCUS IS-PEEM) which was composed of electro-static-lens optics together with an electron energy-analyzer. The presence of SCL was regularly monitored by measuring resistance between two electrodes (colloidal graphite) pasted on the two ends of sample surface. Figure 1 shows two PEEM images of a same area of the sample; a) is excited with a Hg-lamp and b) with a Xe-lamp. The maximum photon energy of the Hg-lamp is ~4.9 eV which is smaller that the band gap energy ($E_G=5.5\;eV$) of diamond and the maximum photon energy of the Xe-lamp is ~6.2 eV which is larger than $E_G$. The image that appear with the Hg-lamp can be due to photo-excitation to unoccupied states of the hydrogen-terminated negative electron affinity (NEA) diamond surface [2]. Secondary electron energy distribution of the white background of Figs.1a) and b) indeed shows that the whole surface is NEA except a large black dot on the upper center. However, Figs.1a) and 1b) show several features that are qualitatively different from each other. Some of the differences are the followings: the two main dark lines A and B in Fig.1b) are not at all obvious and the white lines B and C in Fig.1b) appear to be dark lines in Fig.1a). A PEEMS analysis of secondary electron energy distribution showed that all of the features A-D have negative electron affinity with marginal differences among them. These differences can be attributed to differences in the details of energy band bending underneath the surface present in SCL [3].

  • PDF

Modified Thermal-divergence Model for a High-power Laser Diode (고출력 레이저 다이오드 광원의 열저항 개선을 위한 하부층 두께 의존성 수정 모델)

  • Yong, Hyeon Joong;Baek, Young Jae;Yu, Dong Il;O, Beom Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.5
    • /
    • pp.193-196
    • /
    • 2019
  • The design and control of thermal flow is important for the operation of high-power laser diodes (LDs). It is necessary to analyze and improve the thermal bottleneck near the active layer of an LD. As the error in prediction of the thermal resistance of an LD is large, typically due to the hyperbolic increase and saturation to linear increase of the thermal resistance as a function of thickness, it is helpful to use a simple, modified divergence model for the improvement and optimization of thermal resistance. The characteristics of LDs are described quite well, in that the values for simulated thermal resistance curves and the thermal cross section followed are almost the same as the values from the model function. Also, the thermal-cross-section curve obtained by differentiating the thermal resistance is good for identifying thermal bottlenecks intuitively, and is also fitted quite well by the model proposed for both a typical LD structure and an improved LD with thin capping and high thermal conductivity.

FHD Flexible Endoscopy Design Using Wedge Prism (Wedge Prism을 이용한 FHD급 연성 내시경 광학계 설계)

  • Park, Sung-Woo;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.295-302
    • /
    • 2022
  • In this paper, a wedge prism application method was studied to design a full-high-definition (FHD)-class high-resolution flexible endoscope. In the case of the conventional flexible endoscope optical system, the F number is made large or a liquid lens is applied to obtain the same imaging performance in a wide depth of field. However, there is a problem in that the diameter of the optical system increases because an additional light guide and equipment are required. To solve this problem, two wedge prisms were applied to the flexible endoscope optical system to adjust the image distance for each object distance. First, two wedge prisms were symmetrically placed on the designed endoscopic optical system. An image distance satisfying the target imaging performance according to each objective distance was derived. Next, the wedge prism decenter value for controlling the image distance was derived. By combining these two data, a wedge prism decenter value that satisfied the target imaging performance at each object distance was applied in multi configurations. As a result of the optimal design applied with the wedge prism, a target imaging performance of more than 20% of the modulation transfer function for a resolution of 178 cycles/mm was satisfied in the entire depth of field of 100 mm-7 mm.