• Title/Summary/Keyword: Large optics

Search Result 352, Processing Time 0.029 seconds

Measurement of Large Mirror Surface using a Laser Tracker (레이저트래커(Laser Tracker)를 이용한 대형 광학 거울의 형상 측정)

  • Jo, Eun-Ha;Yang, Ho-Soon;Lee, Yun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.6
    • /
    • pp.331-337
    • /
    • 2013
  • A large optical surface is fabricated by grinding, polishing and figuring. The grinding process is the most rapid and has the largest amount of fabrication of all processes. If we measure the surface precisely and rapidly in the grinding process, it is possible to improve the efficiency of the fabrication process. Since the surface of grinding process is rough and not shiny, it is not easy to measure the surface using light so that we cannot use an interferometer. Therefore, we have to measure the surface using a mechanical method. We can measure the surface under the grinding process by using a laser tracker which is a portable 3-dimensional coordinate measuring machine. In this paper, we used the laser tracker to measure the surface error of 1 m diameter spherical mirror. This measurement result was compared to that of an interferometer. As a result, surface measurement error was found to be $0.2{\mu}m$ rms (root mean square) and $2.7{\mu}m$ PV (Peak to Valley), which is accurate enough to apply to the rough surface under the grinding stage.

Profile, Facilities, and Options for Collaboration with Steward Observatory

  • Green, Richard F.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.41.2-41.2
    • /
    • 2015
  • Steward Observatory has a rich and diverse program of investigations, with significant groups working on star and planet formation and astrobiology, galaxy and quasar formation and evolution, technology for adaptive optics and interferometry, computational astrophysics, and effectiveness of educational practice. To support this work, Steward operates and offers a range of observational and other facilities, including the Large Binocular Telescope, the MMT, the Magellan Telescopes, the Arizona Radio Observatory, and a suite of 1- and 2-m class telescopes. A special opportunity for IR astronomy exists with Arizona now running UKIRT. Steward Observatory astronomers would welcome the opportunity to form genuine scientific collaborations that are mutually beneficial for high-impact projects and improving the observing facilities.

  • PDF

Large Optics (광학산업 로드맵-대형 광학계)

  • Korea Optical Industry Association
    • The Optical Journal
    • /
    • s.114
    • /
    • pp.68-70
    • /
    • 2008
  • 국내 광산업은 80년대 카메라, 복사기 등 결상기기 중심에서 90년대 이후에는 결상기기와 더불어 레이저 가공기, 광정보기기, 광통신기기 등 광응용기기로 확대 되고 있다. 2005년 기준으로 볼 때 국내 광산업은 세계시장의 약 5.5%를 차지했으며, 정밀 광산업 기술로드맵과 직접 관련되는 광정밀기기, 광정보기기, 광학기기분야의 수입은 68%, 수출이 90%를 차지해 수출역점산업임을 알 수 있다. 따라서 2010년에는 광산업 세계 시장규모가 400조 원 수준에 이를 것으로 예상되는 가운데 이에 대비하여 국내 광산업의 성장기틀을 다질 때이다.

  • PDF

Digital Holography - Principles and Challenges of Holographic Projection Systems

  • Schwerdtner, A.;Olaya, J.C.;Haussler, R.;Leister, N.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1753-1756
    • /
    • 2007
  • In the field of 3D display, holographic displays are the only technology allowing optimal user comfort. We have developed systems based on compact projection optics, that allow advantageous new features, like large size full-color3D scenes generated at high rate on a micro-display with state of the art resolution.

  • PDF

Development of Laser Reference System for the Large Optics Testing (큰 광학면 측정을 위한 레이저 기준계의 개발)

  • ;David Walker
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.94-95
    • /
    • 2001
  • 본 논문에서는 큰 광학면을 Profilometry로 측정하는데 있어서 꼭 필요한 기준계로 공기 중을 전파해가는 레이저 광선을 이용하는 방법을 논의하였다 Profilometer는 stylus tip이 직접 표면에 접촉하여 높이를 읽어가는 방식으로 이때 기준계는 정확한 높이를 구하는데 아주 중요한 역할을 한다 즉, 높이의 측정은 기준계를 기준 하여 이루어지기 때문에 기준계에서의 오차는 곧바로 높이의 오차로 이어지게 된다. (중략)

  • PDF

Application of rotating polarizer method for small cellgap measurement (회전평광법을 이용한 낮은 셀갭 측정)

  • 김창선;이기동;윤태훈;김재창
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.3
    • /
    • pp.158-162
    • /
    • 2000
  • Measurement of low cell gap and retardation by using a rotating polarizer method was proposed. For more precise calculation and measurement, we applied a simple numerical calculation and a retardation film that has large retardation value of 1 ~m to measurement system. From experiments, we proved that cell gap and retardation could be measured even though the values of those are so small. small.

  • PDF

Diffraction grating interferometer of large equivalent wavelength for flatness testing of rough surfaces (거친 표면 형상측정을 위한 큰 등가파장 회절격자 간섭계)

  • 황태준;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.56-62
    • /
    • 2004
  • We present a diffraction grating interferometer of large equivalent wavelength specially designed for flatness testing of rough surfaces. Two transmission diffraction gratings are illuminated on the object under test by use of two measurement beams with different angles of incidence, which yields a large equivalent wavelength. This interferometer design minimizes unnecessary diffraction rays and the systematic error caused by the diffraction gratings, and provides a large working distance and easy alignment. To improve the measurement accuracy, phase shifting technique is applied and the equivalent wavelength error caused by defocus is calibrated. Test results obtained from mirror surfaces and machined rough surfaces are discussed.

Hybrid (refrctive/diffractive) lens design for the ultra-compact camera module (초소형 영상 전송 모듈용 DOE(Diffractive optical element)렌즈의 설계 및 평가)

  • Lee, Hwan-Seon;Rim, Cheon-Seog;Jo, jae-Heung;Chang, Soo;Lim, Hyun-Kyu
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.3
    • /
    • pp.240-249
    • /
    • 2001
  • A high speed ultra-compact lens with a diffractive optical element (DOE) is designed, which can be applied to mobile communication devices such as IMT2000, PDA, notebook computer, etc. The designed hybrid lens has sufficiently high performance of less than f/2.2, compact size of 3.3 mm (1st surf. to image), and wide field angle of more than 30 deg. compared with the specifications of a single lens. By proper choice of the aspheric and DOE surface which has very large negative dispersion, we can correct chromatic and high order aberrations through the optimization technique. From Seidel third order aberration theory and Sweatt modeling, the initial data and surface configurations, that is, the combination condition of the DOE and the aspherical surface are obtained. However, due to the consideration of diffraction efficiency of a DOE, we can choose only four cases as the optimization input, and present the best solution after evaluating and comparing those four cases. On the other hand, we also report dramatic improvement in optical performance by inserting another refractive lens (so-called, field flattener), that keeps the refractive power of an original DOE lens and makes the petzval sum zero in the original DOE lens system. ystem.

  • PDF

A Study on the Method for the Local Transmittance Measurements of the Ocular Lens (안경 렌즈의 국소적 투과율 측정을 위한 방법에 관한 연구)

  • Park, Sang-Kook;Ri, Hyeong-Cheol;Youk, Do-Jin;Sung, Duk-Yong;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.471-477
    • /
    • 2014
  • Purpose: We have analyzed the transmittance distribution of the ocular lens using local transmittance microscope to investigate the optical homogeneity of the lens. Methods: The transmittance of the laser which is focused on the surface of the ocular lens was measured by using the photo-detector and lock-in amplifier and analyzed. Multi-coated, uncoated, and progressive lenses were analyzed. Results: In the measurement of the progressive lens and a physical stimulated lens, local transmittance microscopy analysis showed a high degree of match with the measurement results through the optical microscope. In addition, the average value of the transmittance is reduced and the standard deviation was increased in the presence of optical defects. In unstimulated lens, there are a large impact on transmittance whether the anti-reflective coating is presence or absence in both the local transmittance microscopy and general transmittance analysis. Conclusions: The distribution of the transmittance measured by local transmission microscopy were changed when the various stimulus is applied to the lenses. These analyzes by local transmission microscopy can be utilized as a way to evaluate or determine the uniformity of the coating film or lens.

Numerical Analysis on the Effect of Long-crested Wave to the RCS of Marine Target (장파봉파가 해상표적의 RCS에 미치는 영향에 대한 수치해석)

  • Kim, Kook-Hyun;Cho, Dae-Seung;Kim, Jin-Hyeong;Lee, Jeong-Kwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.3 s.147
    • /
    • pp.384-391
    • /
    • 2006
  • RCS effects of long-crested wave surfaces to marine targets are numerically analyzed using a 4-path model and a direct analysis method, developed based on physical optics and a combined method of physical optics/geometric optics, respectively. Reflectivity of long-crested wave surfaces is described with 'Fresnel reflection coefficients' The MPM(modified Pierson-Moskowitz) ocean spectrum is adopted to simulate long-crested waves in the direct analysis method. A numerical analysis of a benchmark model assures the validity of both methods. The direct analysis method is applied to the RCS calculation of electromagnetically large marine targets, which are vertically oriented or slanted to the long crested wave surfaces randomly generated with various significant wave heights. The long-crested wave surface much highly increases the RCS of the marine target, but those effects are decreased as the significant wave height grows up. At low elevation angle, the vertical model has entirely high RCS comparing slanted model, and the RCS of vertical flat plate is the highest on the calm sea surface, while those of slanted flat plates are the lowest on the calm sea surface. The RCS of marine targets on continuously-varying sea surface is more coherent at lower elevation angles, as well.