• 제목/요약/키워드: Large fault

검색결과 672건 처리시간 0.029초

분산전원 계통 연계 전용선로에 설치된 보호 계전기의 정정에 관한 연구 (A Study on Correction of the Protective Relay Equipped in the Dedicated Line Used for Connecting Distributed Generators to Power Network)

  • 정종찬;장성일;최돈만;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.141-144
    • /
    • 2002
  • This paper describes the correction of the protective relay equipped in the dedicated line used for connecting distributed generators (DG) to power grid. The fault current measured in a relaying point might be changed according to the fault conditions. Generally, the fault current of the line to line fault or the line to ground fault at the dedicated line is much higher than the protective set value due to the large fault level. However. when the high impedance fault is occurred in the dedicated line, we may not detect it because its fault level can be lower than the generating capacity of DG. And, the protective relay with conventional set value may generate a trip signal for insertion of DG due to the large transient characteristics of generators. Through the various simulations such as the fault in the dedicated line and the insertion of DG, we show that it would be necessary to modify the protective relay set value for detecting the high impedance fault occurred in the dedicated line and for preventing the mis-operation of protective relay caused by the insertion of DG.

  • PDF

Operating characteristics of a superconducting DC circuit breaker connected to a reactor using PSCAD/EMTDC simulation

  • Kim, Geon-woong;Jeong, Ji-sol;Park, Sang-yong;Choi, Hyo-sang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권3호
    • /
    • pp.51-54
    • /
    • 2021
  • The DC system has less power loss compared to the AC system because there is no influence of frequency and dielectric loss. However, the zero-crossing point of the current is not detected in the event of a short circuit fault, and it is difficult to interruption due to the large fault current that occurs during the opening, so the reliability of the DC breaker is required. As a solution to this, an LC resonance DC circuit breaker combined a superconducting element has been proposed. This is a method of limiting the fault current, which rises rapidly in case of a short circuit fault, with the quench resistance of the superconducting element, and interruption the fault current passing through the zero-crossing point through LC resonance. The superconducting current limiting element combined to the DC circuit breaker plays an important role in reducing the electrical burden of the circuit breaker. However, at the beginning of a short circuit fault, superconducting devices also have a large electrical burden due to large fault currents, which can destroy the element. In this paper, the reactor is connected to the source side of the circuit using PSCAD/EMTDC. After that, the change of the fault current according to the reactor capacity and the electrical burden of the superconducting element were confirmed through simulation. As a result, it was confirmed that the interruption time was delayed as the capacity of the reactor connected to the source side increased, but peak of the fault current decreased, the zero-crossing point generation time was shortened, and the electrical burden of the superconducting element decreased.

시뮬레이션을 이용한 하이브리드 초전도 전류제한기의 반주기 후 한류 방식 분석 (Analysis on the Limiting Method after Half Cycle of Hybrid Superconducting Fault Current Limiter using Simulation)

  • 안재민;김진석;문종필;임성훈;김재철;현옥배;설규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.63-64
    • /
    • 2008
  • The increase of fault current due to large demand has caused the capacity of power machines in power grid to increase. To protect the power system effectively from the large fault current, several superconducting fault current limiters have been proposed. however, in order to apply superconducting fault current limiters into power system, there are many problems such as cost, recovery, AC loss, and cryogenic. In order to solve these problems, hybrid superconducting fault current limiter(HSFCL) was proposed. However, HSFCL also has a problem that is protective coordination in distribution system with HFSCL. In this paper, HSFCL limiting after half cycle modeled and analyzed about protective coordination.

  • PDF

발전기시스템의 고정자보호 IED를 위한 개선된 알고리즘 (Advanced Algorithm for IED of Stator Winding Protection of Generator System)

  • 박철원
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.91-95
    • /
    • 2008
  • The large AC generator fault may lead to large impacts or perturbations in power system. The generator protection control systems in Korea have been imported and operated through a turn-key from overseas entirely. Therefore a study of the generator protection field has in urgent need for a stable operation of the imported goods. In present, the algorithm using the current ratio differential relaying based DFT for stator winding protection or a fault detection had been applied that of internal fault protection of a generator. the DFT used for the analysis of transient state signal conventionally had defects losing a time information in the course of transforming a target signal to frequency domain. In this paper, the discrete wavelet transform (DWT) was applied a fault detection of the generator being superior to a transient state signal analysis and being easy to real time realization. The fault signals after executing a terminal fault modeling collect using a MATLAB package, and calculate the wavelet coefficients through the process of a muiti-level decomposition (MLD). The proposed algorithm for a fault detection using the Daubechies WT (wavelet transform) was executed with a C language and the commend line function for the real time realization after analyzing MATLAB's graphical interface. The advanced technique had improved faster a speed of fault discrimination than a conventional DFR based on DFT.

풍력발전단지 연계 전용선로 보호계전방식의 향상에 대한 연구 (A Study on the Improved Protective Relaying Algorithm Applied in the Linked System Interconnecting Wind Farm with the Utilities)

  • 장성일;김광호;권혁완;김대영;권혁진
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권12호
    • /
    • pp.675-683
    • /
    • 2003
  • This paper describes the correction strategy of an overcurrent relay applied in the linked line for interconnecting wind farm with utility power networks in order to improve the capability of a fault detection. The fault current measured in a relaying point might vary according to the fault conditions. Generally, the current of the line to line fault or the line to ground fault in the linked line is much higher than the set value of protective relay due to the large fault level. However, when the high impedance fault occurs in the linked line, we can't detect it by conventional set value because its fault level may be lower than the generating capacity of wind farm. And, the protective relay with conventional set value may generate a trip signal for the insertion of wind turbine generators due to the large transient characteristics. In order to solve above problems and improve protective relaying algorithms applied in the linked line, we propose a new correction strategy of the protective relay in the linked line. The presented method can detect the high impedance fault which can't be detected by conventional relay set value and may prevent the mis-operation of protective relay caused by the insertion of wind farm.

신경회로망 독립성분해석을 이용한 음향센서 기반 대전력기기의 고장진단 알고리즘 (Acoustic Sensors based Fault Diagnosis Algorithm for Large-scaled Power Machines using Neural Independent Component Analysis)

  • 조현철;이진우;이영진;이권순
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.881-888
    • /
    • 2008
  • We present a novel fault diagnosis methodology using acoustic sensor systems and neural independent component analysis for large-scaled power machines. Acoustic sensors are carried out to measure sounds generated from power machines whose signal is used to determine whether fault is occurred or not. Acoustic measurements are independently mixed and deteriorated from original source signals. We propose a demixing algorithm against such mixed signals by means of independent component analysis which is achieved based on information theory and higher-order statistics to derive learning mechanism.

고장진단 알고리즘 개발 (Development of Algorithm for Fault Diagnosis)

  • 서규석;옥치연;백영식;김정년
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.248-250
    • /
    • 2003
  • Recently, electric power system's situation grows gradually so Fault Diagnosis is being complicated and is felt difficult. And ability that operator who is using electric power system must do correct judgment of power system state, and can cope at fault of power system state is required. Therefore, large size power system is divided into predefined minimum module, and define each module accident type. We use and compare defined accident type, we can know easily accident that happen forward. Therefore, large size power system using module that is defined to each section common accident type search in this paper. Therefore, large size power system using module that is defined to each section, we search for common accident type. And when accident in electric power system happens, I wish to explain about process that can do fault diagnosis in more easy and fast time, because using accident type that it is verified in front.

  • PDF

Ybus분해법에 의한 다중사고 고장전류 해석 (Simultaneous fault Current Analysis by the Ybus Decomposition Method)

  • 문영현;오용택;박재용
    • 대한전기학회논문지
    • /
    • 제37권2호
    • /
    • pp.73-79
    • /
    • 1988
  • A fault current in Simultaneous faults is calulated, which satisfies the reliability for expansion of power scale. New algorithm for analyzing fault current is developed, which calculates exactly thevnin equivalent impedance from fault point by cecomposing increment bus admittance matrix ( Ybus), and fault current is calculated by applying multiport theory. The signeficant results are as follows ` 1) When system fault changes system configulation, equivalent impedance can be calculated simply with this new algorithm. 2) Mutual coupling of transmission line can be calculated efficiently. 3) Simultaneous fault current is analyzed by applying multiport theory, which can be applicable to large scale systems.

  • PDF

초대규모 집적 또는 웨이퍼 규모 집적을 이용한 셀룰러 병렬 처리기의 재구현 (Reconfiguration Problems in VLSI and WSI Cellular Arrays)

  • 한재일
    • 한국통신학회논문지
    • /
    • 제18권10호
    • /
    • pp.1553-1571
    • /
    • 1993
  • 전형적인 컬퓨터보다 훨씬 강력한 계산 능력을 얻기 위해 병렬 컴퓨터 구조에 대한 많은 연가 진행되어 왔다. 이러한 컴퓨터들은 통상 상호 연결 네트워크(Interconnection Network)로 연결된 많은 수의 처리기들로 구성된다. 그중 중요한 한 부류가 초대규모 집적(Very Large Scale Integration) 또는 웨이퍼규모 집적(Wafer Scale Integration)을 이용한 셀룰러 병렬 처리기로 하나의 칩이나 웨이퍼에 단지 이웃으로만 연결된 많은 수의 단순 조를 가지는 처리기로 구성된다. 이런 셀룰러 병렬 처리기틀에 반드시 수반되는 문제가 재구현(Reconfiguration)으로 세가지 유형을 정의할 수 있는데 본 논문에서는 이 세가지 재구현 문제, 즉 결함 허용 재구현(Fault-Tolerant Reconfiguration), 기능적 재구현(Functional Reconfiguration), 그리고 통합 재구현(Integrated Reconfiguration)에 대하여 논하였다. 본 논문은 결함 진단 및 검출(Fault Detection and Fault Location) 제어 방법, 구성(Configuration) 제어방법, 재구현의 수행 단계 등 결함 허용 재구현과 기능적 재구현시 필요한 여러 고려 사항을 분석 정리하고, 최근 제기된 결함 허용 재구현과 기능적 재구현의 일체화 문제 즉 통합 재구현 문제의 이해에 핵심적인 결할 허용 재구현과 기능적 재구현 사이의 관계를 밝혔으며, 통합 재 구현에 적합한 결할 진단 및 검출 제어 방법과 구성제어 방법에 대하여 논하였다.

  • PDF

Response of steel pipeline crossing strike-slip fault in clayey soils by nonlinear analysis method

  • Hadi Khanbabazadeh;Ahmet Can Mert
    • Geomechanics and Engineering
    • /
    • 제34권4호
    • /
    • pp.409-424
    • /
    • 2023
  • Response of the pipeline crossing fault is considered as the large strain problem. Proper estimation of the pipeline response plays important role in mitigation studies. In this study, an advanced continuum modeling including material non-linearity in large strain deformations, hardening/softening soil behavior and soil-pipeline interaction is applied. Through the application of a fully nonlinear analysis based on an explicit finite difference method, the mechanics of the pipeline behavior and its interaction with soil under large strains is presented in more detail. To make the results useful in oil and gas engineering works, a continuous pipeline of two steel grades buried in two clayey soil types with four different crossing angles of 30°, 45°, 70° and 90° with respect to the pipeline axis have been considered. The results are presented as the fault movement corresponding to different damage limit states. It was seen that the maximum affected pipeline length is about 20 meters for the studied conditions. Also, the affected length around the fault cutting plane is asymmetric with about 35% and 65% at the fault moving and stationary block, respectively. Local buckling is the dominant damage state for greater crossing angle of 90° with the fault displacement varying from 0.4 m to 0.55 m. While the tensile strain limit is the main damage state at the crossing angles of 70° and 45°, the cross-sectional flattening limit becomes the main damage state at the smaller 30° crossing angles. Compared to the stiff clayey soil, the fault movement resulting 3% tensile strain limit reach up to 40% in soft clayey soil. Also, it was seen that the effect of the pipeline internal pressure reaches up to about 40% compared to non-pressurized condition for some cases.