• 제목/요약/키워드: Large discharges

검색결과 93건 처리시간 0.019초

고압전동기 고정자 권선의 운전중 부분방전 분석 (Analysis of On-Line Partial Discharge in High Voltage Motor Stator Windings)

  • 이상길;김희동;김광헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.152-155
    • /
    • 2002
  • During normal operation, partial discharge(PD) tests were performed using turbine generator analyzer(TGA) in high voltage motor. Epoxy-mica couplers are installed at motor terminal and analyzed PD signal using TGA. #A motor stator insulation is good because small partial discharges are detected PD pattern show that PD occurs in insulation. PD of #B motor is larger than that of #A motor and PD pattern show that positive PD larger than negative PD. It means that PD occurs between insulation and slot. And A phase PD magnitude of #B motor is large and high compare with any other phase. Therefore wedge, core and slot of #B motor need to check and repair.

  • PDF

고압전동기 고정자 권선의 운전중 부분방전 분석 (Analysis of On-Line Partial Discharge in High Voltage Motor Stator Windings)

  • 이상길;김희동;김광헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.199-202
    • /
    • 2002
  • During normal operation, partial discharge(PD) tests were performed using turbine generator analyzer(TGA) in high voltage motor. Epoxy-mica couplers are installed at motor terminal and analyzed PD signal using TGA. #A motor stator insulation is good because small partial discharges are detected. PD pattern show that PD occurs in insulation. PD of #B motor is larger than that of #A motor and PD pattern show that positive PD larger than negative PD. It means that PD occurs between insulation and slot. And A phase PD magnitude of #B motor is large and high compare with any other phase. Therefore wedge, core and slot of #B motor need to check and repair.

  • PDF

수위관측과 수리학적 하도추적에 의한 수위-유량 관계식작성 (Determination of Stage-discharge Relations by Hydraulic Channel Routing and Stage Measurement)

  • 이상호
    • 한국수자원학회논문집
    • /
    • 제34권5호
    • /
    • pp.551-560
    • /
    • 2001
  • 낙동강의 화원-교령교-현풍 수위관측소 구간에 대하여 수리학적 하도추적을 통하여 조도계수를 추정하였다. 세 관측소의 연속 수위자료와 하천 종횡단 측량자료만이 이에 사용되었다. 하도추적에 의해 계산된 유량자료로부터 수위-유량 관계식을 작성하였으며 이는 기존의 수위-유량 관계식보다 나은 결과를 보였다. 수위측정 오차가 유량계산에 미치는 영향에 대하여 분석하였으며, 측방유입류를 억제할 수 있도록 하도길이를 제한하는 방법도 제시하였다.

  • PDF

Numerical Analysis of the Incident Ion Energy and Angle Distribution in the DC Magnetron Sputtering for the Variation of Gas Pressure

  • Hur, Min Young;Oh, Sehun;Kim, Ho Jun;Lee, Hae June
    • Applied Science and Convergence Technology
    • /
    • 제27권2호
    • /
    • pp.26-29
    • /
    • 2018
  • The ion energy and angle distributions (IEADs) in the DC magnetron sputtering systems are investigated for the variation of gas pressure using particle-in-cell simulation. Even for the condition of collisionless ion sheath at low pressure, it is possible to change the IEAD significantly with the change of gas pressure. The bombarding ions to the target with low energy and large incident angle are observed at low pressure when the sheath voltage drop is low. It is because the electron transport is hindered by the magnetic field at low pressure because of few collisions per electron gyromotion while the ions are not magnetized. Therefore, the space charge effect is the most dominant factor for the determination of IEADs in low-pressure magnetron sputtering discharges.

Partial Discharge Ultrasonic Analysis for Generator Stator Windings

  • Yang, Yong-Ming;Chen, Xue-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.670-676
    • /
    • 2014
  • The objective of this research is to utilize the ultrasonic method to analyze the property of partial discharge (PD) which is generated by the winding of the insulation stator in the generator. Therefore, a PD measurement system is built based on ultrasonic and virtual instruments. Three types of PD models (internal PD model, surface PD model and slot PD model) have been constructed. With the analysis of these experimental results, this research has identified the ultrasonic signals of the discharges which were produced by three types of PD models. This analysis shows the different features among these PD types. Both the time domain and frequency domain of the ultrasonic signals are obviously different. In addition, an experiment based on a large rotating machine has been done to analyze ultrasonic noises. The result indicates that the ultrasonic noises can be wiped off by the filters and algorithms. The application of this system is convenient for the detection of early signs of insulation failure, which is an effective method for diagnosis of insulation faults.

개에서 편측성 난소낭종의 방사선학적 및 초음파학적 진단 2례 (Radiographic and Ultrasonographic Diagnosis of Unilateral Ovarian Cysts)

  • 이기창;최민철
    • 한국임상수의학회지
    • /
    • 제19권3호
    • /
    • pp.367-370
    • /
    • 2002
  • A female, 14-year-old mixed dog weighing 4 kg and a female,8-year-old schnauzer dog weighing 6 kg showing vaginal discharges and vomiting for a few weeks were examined for the preoperative check of anterior cruciate ligament rupture and the recheck after the surgery of nephrectomy. There were no distinct abnormal signs except for the increased CBC at schnauzer dog on blood chemistry analysis. Radiographic and ultrasonographic findings were a large abdominal mass and a cyst-like hypoechogenic or anechogenic cavitary lesion on the ovary region. These findings were consistent with an ovarian cyst. Thereafter highly suspected ovarian cysts by diagnostic imaging were supported by high estrogen concentration on hormonal assay and the results of Pathologic examination as the unilateral ovarian cysts with secondary pyometra.

The Lubrication Characteristics of the Vane Tip Under Inlet Pressure Boundary Conditions for an Oil Hydraulic Vane Pump

  • Cho Ihn-Sung;Oh Seok-Hyung;Jung Jae-Youn
    • Journal of Mechanical Science and Technology
    • /
    • 제19권12호
    • /
    • pp.2179-2186
    • /
    • 2005
  • The lubrication modes of line contact between the vane and the camring in an oil hydraulic vane pump have been investigated. First, variations of the radial acting force of a vane were calculated from previously measured results of the dynamic internal pressure in four chambers surrounding a vane. Next, distinctions of the lubrication modes were made using Hooke's chart, which represents an improvement over Johnson's chart. Finally, the influence of boundary conditions in the lubrication region on fluid film lubrication was examined by calculating film pressure distributions. The results show that the lubrication modes of the vane tip are a rigid-variable viscosity region. This region discharges pressure higher than 7 MPa, and exerts a great influence on oil film pressure in the large arc section due to the Piezo-viscous effect.

서남극 남 쉐틀랜드 군도 마리안 소만에서 바람 및 강수에 의한 여름철 수층 구조의 변화와 부유물질 분산 (Wind-and Rain-induced Variations of Water Column Structures and Dispersal Pattern of Suspended Particulate Matter (SPM) in Marian Cove, the South Shetland Islands, West Antarctica during the Austral Summer 2000)

  • 유규철;윤호일;오재경;강천윤;김예동;배성호
    • 한국해양학회지:바다
    • /
    • 제8권4호
    • /
    • pp.357-368
    • /
    • 2003
  • 남극 세종기지 앞에 위치한 마리안 소만의 여름 수층 구조과 부유물질 분산기작을 이해하기 위해 빙벽 앞에서 CTDT 연속측정을 하였으며, 측정기간 동안의 조석, 부유물질농도, 유속, 그리고 기상요인도 함께 분석되었다. 45 시간동안 1시간 간격으로 측정된 연속 수층 특성 분포에 의하면, 수심 0∼20 m에는 저온$.$저염$.$고탁도의 혼합 표층수가 존재하였고, 수심 20∼40 m에 고온$.$고염$.$저탁도의 최대수온층인 맥스웰 만 유입수가 나타난다. 그 아래의 수심 40∼70 m에는 주변 해수에 비해 저온$.$고탁도의 아빙하성 유출수인 중층 플름(빙하기저부)이 위치한다. 마지막으로 수심 70 m 이하에 나타나는 저층수는 저온$.$고염$.$저탁도의 특성을 보였다. 늦여름 (2 월초)에 연안의 높아진 설선에서 녹아 소만으로 유입하는 담수의 특성은 유입지역의 특성(지형, 빙하조건, 퇴적물의 구성 등)에 따라 수온과 부유물질농도에서 차이를 보였으며, 바람이 거의 불지 않는 측정시기 동안에는 저염$.$고탁도의 표층 플름이 유입지역에 제한적으로 나타났다. 지속적으로 강한 바람이 불 경우, 빙벽 앞에서 육성기원의 혼탁한 담수성 플름, 저온의 중빙하성 용승수/조수빙하 융빙수 그리고 맥스웰 만 유입수가 혼합되면서 표층에 혼합층(저온$.$저염$.$고탁도)이 발달하였다. 소만의 강수는 단기간 빙하성 유출 증가의 가장 큰 요인이며, 중빙하성 용승수의 발생은 조수빙하의 상태와 강수량이 크게 좌우하였다. 특히 많은 양의 강수로 인해 아빙하성 중층 플름의 유출량이 커지면서 중층 이하의 수심에 저염화를 초래하였다. 그러나 입자가 거의 없을 정도로 깨끗한 중앙 빙벽에서 나오는 중빙하성 용승수와 중층 플름의 유입량이 클지라도, 낮은 부유물질농도로 인해 육성기원 입자의 소만 퇴적율은 작을 것이다.

화력 발전기 고정자 권선에서의 수소 압력에 따른 부분 방전 특성 (The Effect of Hydrogen Pressure on Partial Discharge Spectroscopy in Turbine Generator Winding Insulations)

  • 김진봉;황돈하;김용주;박명수;김택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1320-1325
    • /
    • 1995
  • For hydrogen-cooled large turbine generators, partial discharges in ground wall insulations are suppressed by high hydrogen pressure. The first goal of the experiment is to investigate the effect of hydrogen pressure on partial discharge activity and aging rate in turbine generator winding insulations. A series of tests have been performed on two groups of the accelerated aging experiments. The first group of stator windings was aged under hydrogen pressure of 4 atm while the second group of stator windings was aged under air atmosphere. The stator windings aged under air atmosphere suffer from larger partial discharge magnitude with larger voids at high electrical stress than those under hydrogen pressure. The second goal of the experiment is to evaluate the validity of on-line measurement technique which is normally measured under hydrogen environment. The test results show that further experiments are needed to apply the on-line scheme to turbine generator being under high hydrogen pressure.

  • PDF

유동층 건조설비에 있어서 분진의 정전기 위험성에 관한 실험적 연구 (Experimental Study on Electrostatic Hazards of Powder in Fluidized Bed)

  • 문균태;정재희;최광석
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.19-24
    • /
    • 2010
  • A large amount of electrostatic charges is often generated on polymer powders in fluidized bed and thereby may lead to electrostatic problems. In this study, to evaluate electrostatic hazards of powder in fluidized bed, the electric field(E[v/m]) and the charge amount(q[c/g]) during fluidizing were monitored. We also investigated the Minimum Ignition Energy(MIE [J]) of sample powder used in fluidized bed with the Hartman vertical-tube apparatus. The batch-type fluidized bed system and 2kg as Polypropylene(PP) resin powders were used in the experiments. The following results were obtained: (1) Even when a safe margin of several times was considered, the values of E obtained with PP powder in this paper did not exceed 3 to 5kV/cm, at which an incendiary electrostatic discharge could occur. (2) the ave. q was -0.26${\mu}$C/g during fluidizing. This value was high enough to cause electrostatic agglomeration and adhesion. (3) the entrained PP powder in upper column due to fluidizing could be ignited by electrostatic discharges of 71mJ.