• 제목/요약/키워드: Large diameter socketed pipe piles

검색결과 4건 처리시간 0.016초

대구경 소켓경사반력말뚝의 인발거동에 관한 연구

  • 최용규;김상옥;정창규;정성기;김상일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.277-284
    • /
    • 2000
  • Using the large diameter (D = 2,500mm, L = 40m) batter steel pipe piles, designed as compression piles but used as reaction piles during the static compression load test of socketed test piles (D = 1,000mm, L = 40m), static pile load tests for large diameter instrumented rock-socketed piles were performed. The reaction steel pipe piles were driven 20m into the marine deposit and weathered rock layer and then l0m socketed with reinforced concrete through the weathered rock layer and into hard rock layer. Steel pipe and concrete in the steel pile part, and concrete and rebars in the socketed parts were instrumented to measure strains in each part. The pullout amounts of reaction pile heads were also measured with LVDT. During the static pile load test, total compressional load of about 20MN was loaded on the head of test piles, but load above 20MN was not loaded due to lack of loading capacity of loading system. Over the course of the study, maximum pullout amount up to 7mm was measured in the heads of reaction piles when loaded op to 10MN and 1mm of pullout amount was measured. More than 85% of pullout load was transfered in the residual weathered rock layer and about 10% in the soft rock layer, which was somewhat different transfer mechanism in the static compressional load tests.

  • PDF

대구경 말뚝의 정재하시험시 대구경 경사반력말뚝의 인발거동 (The Pullout Behavior of a Large-diameter Batter ]Reaction Piles During Static Pile Load Test for a Large Diameter Socketed Pipe Pile)

  • 김상옥;성인출;박성철;정창규;최용규
    • 한국지반공학회논문집
    • /
    • 제18권1호
    • /
    • pp.5-16
    • /
    • 2002
  • 본 연구에서는 직경 1,000mm의 시험말뚝에 대한 압축정재하시험 수행시 반력말뚝으로 사용된 직경 2,500mm의 대구경 경사반력소켓말뚝의 인발거동을 분석하였다. 경사반력말뚝은 풍화암층과 연암층 10m에 걸쳐서 현장타설말뚝으로 소켓되어졌으며, 강관부는 강관과 속채움콘크리트로, 그리고 소켓부는 콘크리트와 철근으로 구성되었다. 각 구성부재에 작용하는 변형율을 측정하기 위해 센서를 설치하였으며, 반력말뚝두부의 인발량을 측정하기 위하여 LVDT를 설치하였다. 정재하시험중 재하된 최대인발하중은 10MN이었으며 최대인발변위는 7m, 잔류인발변위는 최대 1mm 정도 발생하였다. 인발하중의 83%를 풍화암층에서 그리고 12%를 연암층에서 지지하는 것으로 나타났으며 풍화암에 소켓된 철근콘크리트부와 연암에 소켓된 털근콘크리트부에서 각각 125.3kPa와 61.8kPa의 인발응력이 발생하였다. 따라서, 풍화암층에서도 인발하중을 충분하게 지지하고 있으므로 풍화암층은 마찰력을 크게 발휘하는 지지층으로 사용되었다.

대구경 말뚝정재하시험 및 하중전이 측정사례 (Static pile load test and load trasfer measurement for large diameter piles.)

  • 최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 말뚝기초 학술발표회
    • /
    • pp.107-141
    • /
    • 2000
  • Large diameter piles can be defined as piles with diameter of at least 0.76 m (2.5 ft). In bridge foundation, large diameter piles have been used as pier foundations and their use has been increased greatly. In this study, static pile load tests for large diameter piles peformed in Kwangan Grande Bridge construction site were introduced. Also, various sensor installation methods for several types of piles (that is, open-ended steel pipe pile, drilled shafts and socketed pipe piles), pipe axial load measuring method, load transfer analysis method and pile load test results (pile-head load - settlement curve, and pile axial load distribution curve along the pile depth) were introduced.

  • PDF

보수된 대구경 암반 소켈강관말뚝의 연직지지력에 관한 사례연구 (Case Study on the Vertical Capacity of the Repaired Large Diameter Rock-Socketed Stool Pipe Pile)

  • 최용규;김승종;김병희;이광욱;김상일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.185-192
    • /
    • 1999
  • It had found that, as a result of cross-hole tonic logging test, concrete was not filled partially within the bottom 2.0 m of the large diameter (Ø= 2,500mm) rock socketed pile, MP20-P11(socket diameter (Ø= 2,200mm), which was a pile among piles group supporting a pier of Kwangan Grand Bridge. The pile was repaired by the combined cement grout injected through the pipes for the cross-hole sonic logging test and the bore holes for core samples. A month after the cement grouting, repairing was checked by coring and cross-hole sonic logging then 3 times of grouting and 2 times of coring were, in turns, peformed, then repairing was completed successfully. The vertical compressive capacity of the repaired large diameter socketed pile was evaluated by several formulas and software ROCKET, and was more conservative than design load (1,882 ton) of MP20-P11. It is expected that, in the case of the battered socketed piles, it could be more reasonable to analyze the behaviors of a battered pile using 3-D model. A 3-D analysis will be peformed in the future study.

  • PDF