• Title/Summary/Keyword: Large chamber

Search Result 565, Processing Time 0.028 seconds

Experimental Research for Air-borne Noise Reduction of a Multi-layered Insulation (다층 인슐레이션의 차음성능에 대한 실험적 연구)

  • 고강호;김영호;국형석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1185-1191
    • /
    • 2001
  • This paper discusses an experimental method for measuring the insertion loss (IL) performance of multi-layered insulations that are used in vehicles. Instead of two adjacent reverberation chambers which are generally used to measure the transmission loss (TL) of the large sound isolation materials, air-borne sound insulation tester was utilized to determine the IL and articulation index (AI) of standardized insulation materials. In comparison to reverberation chamber method, air-borne sound insulation tester method is more space-saving, more time-saving and more simple to the automotive acoustics. From the empirical results, it is found that the performances of insulation materials are closely connected with density of polyurethane foam, thickness of heavy layer, thickness of polyurethane foam, and application ratio to panel area.

  • PDF

A study on Motion Characteristics of VLCO by Draft (Simple floating body) (가변진동수주장치의 흘수변화에 따른 운동특성연구 (단일 부유체))

  • Lee, Seung-Chul;Bae, Sung-Yong
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.16-21
    • /
    • 2014
  • The structure of the variable liquid column oscillator(VLCO) is analogous to that of the tuned liquide column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. VLCO is the technology to absorb high potential energy made by process of accelerated motions to occur the effect of an air spring by installation of inner air chamber. So, the application of VLCO can obtain to improve efficiency of energy than wave energy converters made in Pelamis Company. In this research, the experiments were carried out for the motion characteristics of simple floating body by varying the amount of internal fluid. The experimental results were compared with the calculated results.

Certification of Noise in Medium Speed Diesel Engine Test Shop (중형 엔진 시운전장의 소음 원인 규명)

  • Cho, S.Y.;Oh, K.T.;Kim, H.W.;Ha, J.S.;Kim, K.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1693-1698
    • /
    • 2000
  • In operating test of medium speed diesel engine, the large noise over 110dBA would be occurred, and silencer should be needed to prevent the transmission of noise through exhaust duct. A near neighborhood of medium speed engine test shop, outbreak of low frequency noise was reported. From the result of noise measurement, it was found that the coupling of engine noise and air column between workshops was main cause of annoying low frequency noise. From this study, 3 ways of reformation methods were proposed; insertion of plenum chamber, placement of baffles, and alteration of direction of exhaust. As a result of these modification, low frequency noise was cancelled out.

  • PDF

Coronary Artery Fistula Associated with Atrial Septal Defect - Report of a Case - (심방중격결손증을 동반한 관상동맥루 치험 1례)

  • 표현인
    • Journal of Chest Surgery
    • /
    • v.23 no.4
    • /
    • pp.758-763
    • /
    • 1990
  • A congenital fistulous communication between the coronary artery and the cardiac chamber or the pulmonary artery is a rare condition, but increasing cases with this anomaly are being recognized with wide spread use of cardiac catheterization and coronary arteriography. Recently we experienced one case of right coronary artery fistula which was associated with atrial septal defect. The patient was a 24 year old female who was admitted because of cardiac murmur, palpitation and dyspnea on exertion after pregnancy. Cardiac catheterization and selective coronary arteriography revealed that a fistulous communication, forming a large aneurysm, was noted from the right coronary artery emptied into the right ventricle. On the operation field, the right coronary artery was curved and markedly dilated from the aorta to the middle segment at acute margin of the right ventricle. The egg-sized aneurysm of dilated right coronary artery was noticed on right ventricle. The aneurysm was incised longitudinally and both the proximal opening and the termination site of the fistula were closed directly with aneurysmectomy. The right atrium was also opened to evaluate the fistulous termination site and repaired only small interatrial septal defect. Postoperative course was uneventful and she was discharged without problems

  • PDF

Study on Carbon Nano Fiber Emitter for Field Emission Lamp (전계방출광원용 카본나노파이버 에미터 연구)

  • Kim, Kwang-Bok;Lee, Sun-Hee;Yu, Seung-Ho;Kim, Dae-Jun;Kim, Yong-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.21-24
    • /
    • 2008
  • Properties of carbon nano fiber (CNF) as field emitters were described. Carbon nano fiber (CNF) of herringbone was prepared by thermal chemical vapor deposition(CVD). Field emitters mixed with organic binders, conductive materials and were prepared by screen-printing process. In order to increase field emissions, the surface treatment of rubbing & peel-off was applied to the printed CNF emitters on cathode electrode. The measurements of field emission properties were carried out by using a diode structure inline vacuum chamber. CNF of herringbone type showed good emission properties that a turn on field was as low as 2.1 $V/{\mu}m$ and current density was as large as 0.15 $mA/cm^2$ of 4.2 $V/{\mu}m$ with electric field. Through the results. we propose that CNFs are suitable for application of electron emitters in Field Emission Devices.

  • PDF

THERMAL MODEL CORRELATION OF A GEOSTATIONARY SATELLITE (정지궤도 위성의 열해석 모델 보정)

  • Jun, H.Y.;Kim, J.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.230-235
    • /
    • 2011
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and was developed by KARI for communication, ocean and meteorological observations. COMS was tested under vacuum and very law temperature conditions in order to correlate thermal model and to verify thermal design. The test was performed by using KARI large thermal vacuum chamber. The COMS S/C thermal model was successfully correlated versus the 2 thermal balance test phases. After model correlation, temperatures deviation of all individual unit were less than $5^{\circ}C$ and global deviation and standard deviation also satisfied the requirements, less than $2^{\circ}C$ and $3^{\circ}C$. The final flight prediction was performed by using the correlated thermal model.

  • PDF

A Case Study on The Reduction and Examination for Noise and Vibration of Backpass Heat Surface in the Power Plant Boiler (발전용 보일러의 후부 전열면 소음진동 저감에 관한 사례 연구)

  • Lee, Gyoung-Soon;Lee, Tae-Hoon;Moon, Seung-Jae;Lee, Jae-Heon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.642-647
    • /
    • 2008
  • The boiler structure is determined by combustion characteristics and construction costs in the combustion chamber of a large commercial boiler. The heat transfer in boiler is composed of the radiation and the convection. The convective heat transfer has happened to back-pass heating surface. The combustion gas sequentially passes through the reheater tube, 1st economizer tube, and 2nd economizer tube. In case of being lowered in boiler height, we have to install additional tube bundle in back-pass heating surface for increasing the heat transfer of boiler, which causes the noise and vibration from combustion gas. When the combustion gas passes through the back-pass tube bundle in specified load of commercial boiler, this paper analyzes the acoustic characteristics between vortex-shedding frequency and natural frequency in tube bundle cavity. The case study reduce the resonance by changing natural frequency characteristics of tube-bundle cavity using a way to install ant-noise baffle in the direction of combustion gas flow.

  • PDF

The Effect of Ambient Air Condition on Heat Transfer of Hot Steel Plate Cooled by an Impinging Water Jet

  • Lee, Pil-Jong;Park, Hae-Won;Lee, Sung-Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.740-750
    • /
    • 2003
  • It has been observed that the cooling capacity of an impinging water jet is affected by the seasonal conditions in large-scale steel manufacturing processes. To confirm this phenomenon, cooling experiments utilizing a hot steel plate cooled by a laminar jet were conducted for two initial ambient air temperatures (10$^{\circ}C$ and 40$^{\circ}C$) in a closed chamber, performing an inverse heat conduction method for quantitative comparison. This study reveals that the cooling capacity at an air temperature of 10$^{\circ}C$ is lower than the heat extracted at 40$^{\circ}C$. The amount of total extracted heat at 10$^{\circ}C$ is 15% less than at 40$^{\circ}C$ , These results Indicate the quantity of water vapor, absorbed until saturation, affects the mechanism of boiling heat transfer.

The Development of Convenient RQ Measuring Device for Patients Real Time Monitoring (환자의 실시간 모니터링을 위한 간편한 RQ 측정기기의 개발)

  • Kim, Y.S.;Jeon, H.M.;Choi, S.W.;Shim, E.B.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1609-1612
    • /
    • 2008
  • RQ(Respiratory Quotient) value is obtained from the ratio of the consumed oxygen and the produced carbon dioxide during the patient's respiration. To investigate the efficacy of insulin and diagnosis the metabolic disorder in short time, the RQ value can be used as important parameter. The measurement of oxygen and carbon dioxide amounts is needed large chamber and complex sensors. But If the atmospheric oxygen and carbon dioxide concentrations do not change, the expiratory oxygen and carbon dioxide can be used to obtain RQ value. A convenient RQ measuring device has been developed by using two sensors for O2 and CO2. The estimation of RQ devices confirms that the RQ device can obtain accurate data by eliminating uncertain factor such as delay time and remaining gases.

  • PDF

A Study on the Characteristics on Ultra Precision Machining of Al6061-T651 (Al6061-T651의 초정밀 절삭특성에 관한 연구)

  • Kim, Geon-Hee;Yang, Sun-Cheol;Park, Yo-Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.1
    • /
    • pp.43-48
    • /
    • 2005
  • This paper is described about the technique of ultra-precision machining for an aerospace aspheric mirror. The reflection mirror system generates parallel beams inside a thermal vacuum chamber. A 200mm diameter aspheric mirror was fabricated by SPDTM. Aluminum alloy as mirror substrates is known to be easily machined, but not polishable due to its ductility. Aspheric large reflector without a polishing process, the surface roughness of 10nm Ra, and the form error of ${\lambda}/2$ (${\lambda}$=632.8nm) for reference curved surface 200mm has been required. The purpose of this research is to find the optimum machining conditions for cutting reflector using Al6061-T651 and apply the SPDTM technique to the manufacturing of ultra precision optical components of Al-alloy aspheric reflector.

  • PDF