• Title/Summary/Keyword: Large Direct Test

검색결과 258건 처리시간 0.017초

대형삼축압축시험 및 대형직접전단시험에 의한 사석재료의 전단강도 평가 (Comparison of Shear Strengths of Crushed Rock Determined by Large Triaxial Test and Direct Shear Test)

  • 신동훈;안태봉;이경필;이한출
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.259-264
    • /
    • 2002
  • In this study the shear strengths of a poorly grad ed rock material(d/sub max/≤50.8mm, C/sub u/=1.86) were determined by large direct shear test and large triaxial test. The obtained stress-strain curves by the above large shear tests for the rock materials are similar to the loose sand's or normally consolidated clay's curve, in which the peak strength does not appear obviously. And for the uniformly graded rock material the shear strength by large direct shear test may be overestimated around 1.54∼1.70 times that of large triaxial test.

  • PDF

굵은 입자가 포함된 풍화토의 전단강도 평가에 대한 실험연구 (An Experimental Study on the Evaluation of Shear Strength of Weathered Soil Containing Coarse Particles)

  • 김준석
    • 한국재난정보학회 논문집
    • /
    • 제20권1호
    • /
    • pp.169-176
    • /
    • 2024
  • 연구목적: 본 논문에서는 직접전단시험에서 시험시편의 규모 때문에 부득이 굵은 입자가 제외되는 문제 때문에 발생되는 전단강도의 차이를 분석하고자 직접전단시험을 실시하는 실험연구를 수행하였다. 연구방법: 최대직경 50mm의 굵은 골재가 포함된 3개의 풍화토를 대상으로 대형직접전단시험을 실시하였다. 또한 굵은 골재가 제외된 최대직경 5mm 시료를 이용하여 소형직접전단시험을 실시하였다. 연구결과: 소형직접전단시험의 경우 큰입자가 포함된 대형직접전단시험의 결과에 비하여 내부마찰각은 약2.3% 작은 값을 도출하여 비교적 큰 차이가 없었다. 점착력에서는 대형직접전단시험에 비하여 소형 직접전단시험이 약 80.3% 작은 값을 도출하여 비교적 큰 차이를 나타내었다. 결론: 대형직접전단시험에서 굵은 입자가 내부마찰각보다는 점착력에 큰 영향을 준 것으로 분석되었다. 따라서, 굵은 입자를 포함한 화강풍화토는 수직응력에 영향을 받지 않는 점착력과 같은 전단강도를 갖고 있는 것으로 판단된다. 본 연구에서는 일반적으로 사용되고 있는 굵은 입자를 제외한 소형직접전단시험은 굵은 입자의 효과를 제외함으로서 안전측의 결과를 제공하는 것으로 분석되었다.

대형직접전단시험과 대형삼축시험을 통한 석산골재의 전단거동 특성 비교 (Comparison of Shear Behavior for Quarry Blasted Rocks Based on Large Scale Direct Shear Test and Large Scale Triaxial Test)

  • 이대수;김경열;오기대
    • 한국지반공학회논문집
    • /
    • 제24권2호
    • /
    • pp.5-14
    • /
    • 2008
  • 국내 석산에서 생산되는 골재를 사용하여 대형삼축시험과 대형직접전단시험을 동시에 수행한 후 전단특성을 비교하였다. 비교를 위하여 시험조건을 가능한 일치시켰으며, 상대밀도를 50%, 70%, 90%의 세 가지로 변화시켜 시험을 수행하였다. 시험결과 응력-변형률 거동은 두 가지 시험에서 동일하게 나타나며, 전단강도는 상대밀도의 크기에 따라 시험방법별로 추세가 달라진다. 즉, 낮은 상대밀도에서는 대형직접전단시험의 내부마찰각이 대형삼축압축시험 결과 값에 비하여 작게 나타나고, 높은 상대밀도에서는 이 현상이 역전됨을 확인하였다.

직접전단시험에 의한 모래의 전단강도에서 시편의 크기효과 (Scale Effects of the Specimen on Shear Strength of sand by Direct Shear Test)

  • 김준석;김지현
    • 한국재난정보학회 논문집
    • /
    • 제15권4호
    • /
    • pp.590-596
    • /
    • 2019
  • 연구목적: 직접전단시험의 문제점 중에 하나인 시험시편의 크기효과에 대하여 모래시료를 대상으로 실험적 연구를 수행하였다. 연구방법: 우리나라를 대표하는 모래인 주문진 표준사를 연구 대상으로 사용하였다. 상대밀도 50%, 60%, 70%, 80%에 대한 전단강도를 분석하기 위하여 대형직접전단시험을 수행한 후 소형직접전단기의 시험결과와 비교분석을 수행하였다. 연구결과: 상대밀도가 촘촘한(dense) 영역에서는 소형전단시험기의 내부마찰각이 비교적 큰 경향이 있는 것으로 분석되었다. 상대밀도가 중간(medium)정도의 영역에서는 대형전단시험기의 결과가 비교적 큰 경향이 있는 것으로 분석되었다. 결론: 모래흙에서 직접전단시험의 시료에 대한 크기 효과는 비교적 크지 않은 것으로 분석되었다.

대형 직접전단시험과 대형 삼축압축시험에 의한 조립재료의 전단강도 비교 (Comparison of Shear Strength of Coarse Materials Measured in Large Direct Shear and Large Triaxial Shear Tests)

  • 서민우;김범주;하익수
    • 한국지반환경공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.25-34
    • /
    • 2009
  • 댐이나 항만 건설시 재료로 사용되는 조립재는 입자크기가 일반 토사에 비해 매우 크기 때문에 이러한 재료에 대해서 전단시험을 수행할 때에는 가급적 대형 전단시험장치를 사용하는 것이 보다 정확한 결과를 얻기 위해 바람직하다. 대형 전단시험장치로는 일반적으로 대형 직접전단시험장치와 대형 삼축압축시험장치가 있으나 일반 토질시험장치와 비교해 제작과 보급, 운영 등의 어려움 때문에 현재까지 국내에서 두 시험장치를 사용하여 시험을 수행한 실적은 많지 않은 편이다. 본 연구에서는 댐 축조재로 사용되는 입경이 큰 조립재료를 대상으로 시료의 평균 입자크기와 공시체 크기, 연직응력(구속압) 조건 등에 차이가 있는 총 6개 case에 대해서 대형 직접전단시험과 대형 삼축압축시험을 수행하고 두 시험간 전단강도 특성의 차이를 비교하였다. Mohr-Coulomb 강도규준에 의한 전단강도를 기준으로, 대형 직접전단시험을 통해 산정된 전단강도가 대형 삼축압축시험을 통해 산정된 전단강도보다 전체적으로 크게 나타났으며 또한, 1,000kPa 수직응력에 대해 두 시험간 산정된 전단강도를 비교한 결과 대형 직접전단시험에 의한 전단강도가 대형 삼축압축시험에 의한 전단강도보다 약 10~70% 크게 나타나 입경이 작은 일반 토사와 비교해 그 차이가 크고, 대형 직접전단시험결과의 분산도가 상대적으로 높은 것으로 나타났다.

  • PDF

링 전단시험기를 이용한 암석절리의 잔류강도 특성에 관한 연구 (A Study on Residual Stress Characteristics for Joint of Rock in Ring Shear Tests)

  • 권준욱;김선명;윤지선
    • 한국지반공학회논문집
    • /
    • 제16권6호
    • /
    • pp.35-41
    • /
    • 2000
  • Residual stress is defined as a minimum stress with a large displacement of specimens and the residual stress after peak shear stress appears with displacement volume but there is no provision to select the residual stress. In the previous study, residual stress was recorded when the change of shear load is small in the condition of the strain more than 15%. But, in this study, hyperbolic function((No Abstract.see full/text), b=experimental constant) of soil test is adapted to joint of rock and the propriety is investigated. In a landslide and landsliding of artificial slope, wedge failure of tunnel with a large displacement, tests are simulated from peak stress to residual stress for safety analysis. But now. direct shear stress and triaxial compressive tests are usually performed to find out characteristics of shear stress about joint. Although these tests get a small displacement, that data of peak stress and residual stress are used for safety analysis. In this study, we tried to determine failure criteria for joints of rock using ring shear test machine. The residual stress following shear behavior was determined by the result of ring shear test and direct shear test. In conclusion, after comparing the results of the two test, we found that cohesion(c) and internal friction angle(ø) of ring shear test are 30% and 22% respectively of those of the direct shear test.

  • PDF

콘크리트 파괴거동특성에 대한 실험적 연구II-직접인장시험 (Experimental Study on Failure Behavior of Plain Concrete - Direct Tension Test)

  • 이상근;이상민;이화미;한상훈;송영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.287-292
    • /
    • 2003
  • The large-scale direct tension tests of plain concrete were performed and then the complete load-CMOD(crack mouth opening displacement) curves with a stable postpeak descending part were presented. Two independently controlled actuators were used to ensure a homogeneous increasing of CMOD in both notches of a specimen and to avoid secondary flexural stresses. It was compared the fracture energies from the test results with them from a classical prediction equation by Bazant and Oh (983), The results are indicated that the fracture energies from these large-scale direct tensile tests are large as 1.5-2 times on average against them from the Bazants prediction equation. But the tensile strength for large-size specimens was about half of the values determined from the splitting tensile strength tests for 10 by 20mm cylindrical specimens due to size effect.

  • PDF

Direct and indirect methods for determination of mode I fracture toughness using PFC2D

  • Sarfarazi, Vahab;Haeri, Hadi;Shemirani, Alireza Bagher
    • Computers and Concrete
    • /
    • 제20권1호
    • /
    • pp.39-47
    • /
    • 2017
  • In this paper, mode I fracture toughness of rock was determined by direct and indirect methods using Particle Flow Code simulation. Direct methods are compaction tension (CT) test and hollow centre cracked quadratic sample (HCCQS). Indirect methods are notched Brazilian disk (NBD) specimen, the semi-circular bend (SCB) specimen, hollow centre cracked disc (HCCD), the single edge-notched round bar in bending (SENRBB) specimen and edge notched disk (END). It was determined that which one of indirect fracture toughness values is close to direct one. For this purpose, initially calibration of PFC was undertaken with respect to data obtained from Brazilian laboratory tests to ensure the conformity of the simulated numerical models response. Furthermore, the simulated models in five introduced indirect tests were cross checked with the results from direct tests. By using numerical testing, the failure process was visually observed. Discrete element simulations demonstrated that the macro fractures in models are caused by microscopic tensile breakages on large numbers of bonded discs. Mode I fracture toughness of rock in direct test was less than other tests results. Fracture toughness resulted from semi-circular bend specimen test was close to direct test results. Therefore semi-circular bend specimen can be a proper test for determination of Mode I fracture toughness of rock in absence of direct test.

무근 콘크리트 인장연화응답의 실험적 연구 (Experimental Study for Tensile Softening Response of Plain Concrete)

  • 이상근;강태경;송영철;권용길;한상훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.423-426
    • /
    • 2001
  • In this paper a large scale direct tension test of plain concrete is represented. Two independently controlled actuators were used to ensure a homogeneous tensile field and to avoid secondary flexural stresses. Fracture energies evaluated by a classical prediction equation and this test are compared. The result indicated that the classical prediction equation is not adequate to predict the fracture energy of large sized specimens. From this test, it was determined that the fracture energy obtained from large scale direct tension tests is significantly higher than the one obtained in wedge splitting tests on laboratory sized specimens. But the tensile strength was about half the value determined from splitting tensile strength test with cylindrical specimens.

  • PDF

Air-Water Test on the Direct ECC Bypass During LBLOCA Reflood Phase with DVI : UPTF Test 21-D Counterpart Test

  • Yun, Byong-Jo;Kwon, Tae-Soon;Song, Chul-Hwa;Euh, Dong-Jin;Park, Jong-Kyun;Cho, Hyoung-Kyu;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • 제33권3호
    • /
    • pp.315-326
    • /
    • 2001
  • Direct ECC bypass phenomena that occur in a reactor vessel downcomer with a Direct Vessel Injection (DVI) system during the reflood phase of a Large Break Loss-of-Coolant Accident (LBLOCA) are experimentally investigated using a transparent l/7.5 scaled down test facility of the Upper Plenum Test Facility (UPTF). A series of separate effect tests are peformed in order to investigate the mechanisms of direct ECC bypass and to find out its scaling parameters. Various flow regimes and phasic distribution in downcomer are identified and mapped, and the fraction of direct ECC bypass is measured under a wide range of air and water injection conditions. From the counterpart test of the UPTF Test 21-D, the dimensionless gas velocity ( $j^{*}$$_{g,eff}$) is derived experimentally, which is believed to be a major scaling parameter for the fraction of direct ECC bypass. And it is found out that the direct ECC bypass is greatly affected by the spreading width of ECC water film and the geometric configuration of the downcomer.r.

  • PDF