• Title/Summary/Keyword: Langevin transducer

Search Result 38, Processing Time 0.033 seconds

Variation In the Vibration Characteristics of Piezoelectric Transducers due to Pre-Pressure (예압에 따른 압전 변환기의 공진 특성)

  • Kim, Dae-Seung;Kim, Jin-Oh
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.484-487
    • /
    • 2005
  • This paper presents an analytical approach to describe the variation in the vibration characteristics such as the natural frequency of a piezoelectric transducer under static pre-pressure. The transducer considered in this paper is a bolt clamped Langevin type transducer, which consists of a couple of piezoelectric discs, a couple of metal blocks for added mass effect, and a bolt to tighten them. A new analysis model for the transducer has been developed by taking into account the contact area between the piezoelectric ceramic and the metal block. The variation of the resonance frequency due to the pre-pressure has been calculated compared with other results.

  • PDF

An approach to design and fabrication of resonant giant magnetostrictive transducer

  • Sheykholeslami, Mohammad R.;Hojjat, Yousef;Cinquemani, Simone;Ghodsi, Mojtaba;Karafi, M.
    • Smart Structures and Systems
    • /
    • v.17 no.2
    • /
    • pp.313-325
    • /
    • 2016
  • The paper provides a comprehensive procedure for the mechanical and magnetic design of Langevin transducer based on giant magnetostrictive material. The the transducer is designed to work at its second mode of vibration, having high mechanical quality factor and low damping coefficient. The design procedure is based on an analytical model and it is verified by finite-element analysis. Experimental tests based on impedance response analysis in first and second modes are carried out on the prototype. Results confirm the appropriate design of this transducer, demonstrating the highest mechanical quality factor between the resonant transducers in the literature.

A Study of Ultrasonic Rotary Motor Using the Langevin Type Vibrator (란쥬반형 진동자를 이용한 초음파 회전 모터에 관한 연구)

  • Lee, Jae-Hyung;Park, Tae-Gone;Kwon, Oh-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.223-227
    • /
    • 2003
  • In this study, ultrasonic rotary motors using a bolted langevin type ultrasonic vibrator were designed and fabricated. The stator vibrator has a longitudinal transducer section composed of two metal blocks and two piezoelectric ceramic elements (thickness-polarized) and a mode conversion metal block section called a torsion coupler. And, three kinds of motors were studied by finite element analysis and experiments. So, as material of torsion coupler which generate mode conversion of vibration copper, brass, and phosphor bronze were used. As a result, speed and torque were changed in proportion to the electrical input Voltage, but it was saturated in high voltage. And bad efficiency which was different from a expectation was measured in this motors. So, various problems should be improved for practical use. Finally, The motor which has 1 [cm] diameter was fabricated to present a possibility of miniaturization of this type motors.

  • PDF

Fabrication and Evaluation of Piezoelectric Torsional Transducers (압전 비틀림 파동 변환기 제작 및 평가)

  • Kwon, Oh-Soo;Kim, Jin-Oh
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.4
    • /
    • pp.434-438
    • /
    • 2001
  • Piezoelectric torsional transducers have been fabricated to generate torsional waves in a rod. The principle of generating torsional wane is based on the use of the circumferential shear motion derived by axial voltage exerted on the piezoelectric disk poled in the circumferential direction. The natural frequency or the piezoelctric torsional dish has been reduced by fabricating Langevin-type torsional transducers. The natural frequecies of the fabricated transducers have been measured and have shown good agreement with the characteristics predicted by analysis.

  • PDF

Development of smart transducer with embedded sensor for automatic process control of ultrasonic wire bonding

  • Or, Siu Wing;Chan, Helen Lai Wa;Liu, Peter Chou Kee
    • Smart Structures and Systems
    • /
    • v.1 no.1
    • /
    • pp.47-61
    • /
    • 2005
  • A ring-shaped lead zirconate titanate (PZT) piezoceramic sensor has been integrated with the Langevin-type piezoceramic driver of an ultrasonic wire-bonding transducer to form a smart transducer for in-situ measurement of three essential bonding parameters: namely, impact force, ultrasonic amplitude and bond time. This sensor has an inner diameter, an outer diameter and a thickness of 12.7 mm, 5.1 mm and 0.6 mm, respectively. It has a specifically designed electrode pattern on the two major surfaces perpendicular to its thickness along which polarization is induced. The process-test results have indicated that the sensor not only is sensitive to excessive impact forces exerted on the devices to be bonded but also can track changes in the ultrasonic amplitude proficiently during bonding. Good correlation between the sensor outputs and the bond quality has been established. This smart transducer has good potential to be used in automatic process-control systems for ultrasonic wire bonding.

Measurement of the self-radiation impedance of an ultrasonic transducer with a square vibrating surface (정방형 방사면을 갖는 초음파 진동자의 자기방사임피던스 측정)

  • Kim, Jungsoon;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.2
    • /
    • pp.108-114
    • /
    • 2017
  • We have experimentally analyzed the self-radiation impedance of an ultrasonic transducer with a square radiation surface that is used as a vibrator in underwater ultrasonic detection systems. The radiation reactance and the radiation resistance were measured in the range from 1 to 3 of ka that is the product of a wave number and a length of the edge of the square vibrator. By comparing the measured results with those of theoretical calculation of the radiation impedance using a series, we confirmed the validity of the experimental method and experimentally confirmed the variation trend in the radiation impedance of the square radiation surface.

A Study on the Design for Untrasonic Spray Nozzle (초음파 분무기용 Nozzle 설계에 관한 연구)

  • Kim, Young-Ho;Cho, Bong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1348-1350
    • /
    • 1994
  • In this study, various nozzle of ultrasonic spray were designed by using Langevin type electrostriction transducer. The electrical and dynamic characteristics of ultrasonic nozzle with various horn type were investigated. We obtained the average particle size and size distribution profiles with output frequency.

  • PDF

Design and driving characteristics of Langevin type transducer for high speed processing machine (고속 가공기용 란쥬반형 진동자의 설계 및 구동특성)

  • 박민호;정동석;박태곤;김명호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.385-388
    • /
    • 2001
  • The cutting performance of a machine depends on the ability of the design of the acoustic horn to facilitate an increase in tool-tip vibration, allowing a significant amount of material to be removed. In this paper, three kinds of acoustic horns were designed and FEM was used to estimate displacement magnifications of horn tips. An optimization procedure for the profile has been followed to obtain maximum magnification, for higher rate of material removal and safe working stresses for the horn material.

  • PDF

Design and Fabrication of a High Power Piezoelectric Ultrasonic Surgery Unit for Dental Implantation (치과 임플란트 수술용 고출력 초음파 수술기 설계 및 제작)

  • Kim, Na Ri;Jeon, Dae Woo;Kim, Jin Ho;Kim, Sun Woog;Hwang, Jong Hee;Lee, Jeong Bae;Choi, Sung Jae;Im, Dae Jin;Lee, Young Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.10
    • /
    • pp.656-664
    • /
    • 2017
  • This paper presents the design and fabrication of a high power piezoelectric ultrasonic surgery unit for multi-purpose dental implantation. A conventional piezoelectric ultrasonic surgery units consists of a transducer and a tip. However, the drawback of this simple structure is that the output performance of the transducer considerably changes with the change of the tips. An ultrasonic surgery unit that has an additional booster between the transducer and the tip can solve this problem to some extent; for this, an optimal structural design for the transducer is required. We used the Bolted Langevin Transducer (BLT) as the basic transducer; it consists of piezoelectric ceramics and a metal body. It's structure was optimized using mathematical methods to determine the length and radius of the tail and head masses. Additionally, the booster was also subjected to the same methods. Using these mathematical methods, optimal results in terms of the resonance frequency (24.96 kHz), displacement ($14.27{\mu}m$), and pressure (2.8 MPa), could be obtained. The validity of this proposed surgery unit was confirmed experimentally, exhibiting a cutting force of around 7% higher than that of a conventional surgery unit.