• Title/Summary/Keyword: Landfill thickness

Search Result 20, Processing Time 0.027 seconds

The Effect of solid Waste Landfill Method on Decomposition of pollutants in Semi-aerobic Landfill Structure (준호기성 매립구조에 있어서 폐기물 매립방법이 오염물질의 분해에 미치는 영향)

  • Lee, Nam-Hoon;Lee, Chae-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.4
    • /
    • pp.153-159
    • /
    • 2000
  • Large-scale simulated lysimeter experiments were conducted for 4 years as a fundamental study to develop enhanced landfill stabilization method, which accelerate stabilization time and make efficient practical use of self-purification capacity of pollutants in semi-aerobic solid waste landfill. The amount of TOC(total organic carbon) decomposition increased as the landfill depth increased. In case of T-N(total nitrogen), the self-purification capacity increased linearly with the landfill thickness until it reached a maximum level of 6 m. Beyond this level, the self-purification capacity was not increased. The results from lysimeter experiments indicate that 6m of landfill thickness is optimum for self-purification capacity of pollutants considering the mass balance of TOC and T-N.

  • PDF

Development of a Computer Program to Estimate Landfill Liner Thickness (매립지 차수재 두께 산정을 위한 컴퓨터 프로그램 개발)

  • Do, Nam-Young;Lee, Seung-Rae;Jeong, Kwang-Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.4
    • /
    • pp.13-26
    • /
    • 2005
  • In this study, research results on organic and inorganic pollutant migration through single and composite liner were summarized. On the basis of these summarized research results, a design program for landfill liner, which can be used to optimize the liner thickness based on the allowable ground water criteria around the landfill subsurface, was developed. A reasonable liner thickness was obtained from the program output results, in the case of the migration of $Cl^-$ ion through a single clay liner. Therefore, the developed program could be used to carry out a preliminary design for landfill liners with respect to organic and inorganic pollutants.

  • PDF

Establishment of Landfill Site Preliminary Assessment Model Based on Contamination Characteristics of Water Resources (수자원(水資源) 오염 특성에 의한 불량매립지(不良埋立地) 예비평가모형(豫備評價模型) 정립)

  • Hong, Sang-Pyo;Kim, Jung-Wuk
    • Journal of Environmental Impact Assessment
    • /
    • v.4 no.1
    • /
    • pp.17-23
    • /
    • 1995
  • To assess preliminarily the contamination potential of water resources including groundwater owing to the hydrogeological characteristics of landfill site and the potential impact to humans and animals through contamination of water resources by leachate, "Landfill Site Preliminary Assessment Model(LASPAS)" was contrived. LASPAS could help them proritization of remediation of landfil sites by the convenient and relatively simple evaluation method of landfill site features. LASPAS was designd to aliot numerical ratings to landfill site related factors undermentioned; 1) hydrogeological factors such as hydraulic conductivity of aquifer, thickness of confining layer over aquifer, topographical slope, net recharge, and subsurface containment 2) water resources contamination factors of impacts on receptors such as proximity to drinking water supply, substitutability of drinking water supply, type of use of water resources, known impact on drinking water supply, and flood potential.

  • PDF

Dipole-Dipole Resistivity Survey on the Side of Han River near Nanjido Landfill (난지도에 인접한 한강변에서의 쌍극자-쌍극자 전기탐사)

  • Lee, Kiehwa;Kwon, Byung-Doo;Oh, Seok-Hoon;Kim, Cha-Seop
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.335-343
    • /
    • 1996
  • The dipole-dipol electrical resistivity survey was conducted to investigate the probable contamination of the Han river by leachate from the near-by Nanjido Landfill. The survey line of 3 km was set along the unpaved road toward the Han river. For the convenience of the field work, the survey line was divided into four segments. The complete two-dimensional resistivity section was constructed by connecting the inversion result of each segment. Gravity survey was also carried out along the profile parallel to the resistivity line. Near surface resistivity generally appeared to be of very low value in most part of the survey area and the boundary between the alluvium layer and underlying basement rocks is well discriminated on the resistivity section. These results agree well with those of the preceding Schlumberger depth sounding made at adjacent area by Lee and fun (1995). The variation of thickness of the alluvium layer delineated by gravity anomaly profile also correlates well with the result of the resistivity survey on the qualitative basis. The problem of contamination by leachate from the Nanjido Landfill, where various waste materials have been dumped without any proper treatment facilities, has been remains unsolved yet. Therefore, we present the most probable passages of leachate flow based on the survey results and have briefly discussed about measure for contamination control. Considering the thickness of alluvium and the possible existence of fractured zone, the middle point between 1st and 2nd landfill and the midst of 1st landfill are the most hazardous regions to make leachates flow into the Han river. Since large amounts of leachates are observed from the test wells located on the lines extending from the border between the 1st and 2nd landfill and the middle of the lst landfill, contamination protection barriers are strongly recommended near these regions.

  • PDF

The Characteristics of Landfill Waste and Leachate on Open Dumping Landfill Site of Small Scale (소규모 단순매립지의 매립폐기물 및 침출수의 특성)

  • Ju, So-Young;Yeon, Ik-Jun;Jeon, Tae-Wan;Wi, Mi-Kyung;Kim, Kwang-Yul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.1 no.1
    • /
    • pp.79-85
    • /
    • 2000
  • The environmental assessment on the open dumping landfill of small scale which was situated in local small city was carried out to reuse the landfill site as the residental, commercial and other purposes through the analysis of the leachate of landfill, extracted solution from landfill waste. The waste was landfilled at 5.5~8m depth and the covered layer so poor as 20~50cm thickness. The biodegradable organic matters were almost degraded and the result of the leachate of landfill showed that the BOD/COD ratio were measured as 0.079, pH 7.2~7.6, SS 47736mg/L, COD 6193.8mg/L, T-N 596mg/L, and T-P 123.9mg/L respectively. These results were higher than those of extracted solution of landfill waste as the COD and BOD were measured as low values and T-N 7.77mg/L and T-P as 0.20mg/L lower concentrations the landfill appears the maturation phase. As the result of the assessment on the open dumping landfill of small scale, if appears that this landfill is maturation phase and the formation leachate is reduced. If the treatment facility of leachate from landfill and the layer which protects the inflow/infiltration is prepared, it can be safely used as this landfill site.

  • PDF

Potential use of waste rubber shreds in drainage layer of landfills - An experimental study

  • Praveen, V.;Sunil, B.M.
    • Advances in environmental research
    • /
    • v.5 no.3
    • /
    • pp.201-211
    • /
    • 2016
  • Laboratory tests were conducted to evaluate the performance of waste rubber shreds in leachate collection layer of engineered landfills. The study found that waste rubber shreds layer in combination with a gravel layer can be of potential use in landfill drainage system. To study the performance, conventional gravel along with waste rubber shreds were used in different combinations (with total layer thickness = 500 mm) as leachate collection media. For the laboratory study poly vinyl chloride (PVC) pipes were used. The size range of waste rubber shreds used were 25 mm to 75 mm in length and width = 10 to 20 mm. The gravel size used in the leachate collection media is 10 mm to 20 mm size. Performance study of 7 Test Cols. with different combinations of waste rubber shreds and gravel bed thickness were studied to find out the best combination. The study found that the Test Col.-3 having waste rubber shreds thickness = 200 mm and gravel layer thickness = 300 mm gave the best results in terms of percentage removal in various physicochemical parameters present in the leachate. Further to find the best size rubber shreds three more Test Cols - 8, 9 and 10 were constructed having the rubber shreds and gravel layer ratio same as that of Test Col.-3 but having rubber shreds width = 10 mm, 15 mm and 20 mm respectively. Based on the results obtained using Test Cols. 8, 9 and 10 the study found that smaller size rubber shreds gave bests results in terms of improvement in various leachate parameters.

Gravity, Magnetic and VLF Explorations in the Seokdae Landfill, Pusan (부산시 석대 매립지에서의 중력, 자력, VLF탐사)

  • Kwon, Byung-Doo;Seo, Jung-Hee;Oh, Seok-Hoon
    • Economic and Environmental Geology
    • /
    • v.31 no.1
    • /
    • pp.59-68
    • /
    • 1998
  • Gravity, magnetic and VLF surveys were carried out to investigate the dimension, nature and stability of the waste materials filled in the Seokdae landfill, Pusan. The Seokdae landfill, which is located in a former valley, was used as a dump for mainly domestic-type waste materials for 6 years from 1987. The landfill site is classfied into A, B, C and D areas according to the sequence of dumping period. The Bouguer gravity anomaly map shows maximum variation of 3.1 mgals on the landfill and its general appearance has close relation with the thickness of waste filled. The local variation of anomaly, however, reflect the degree of compactness of waste materials which may be affected by the nature of waste and dumping time. In the case of area A, where dumping process was terminated at the very last stage, most part show negative anomaly compared to other areas. We think that the composition of the waste materials in the area A is high in leftover food and paper trash and they are still in uncompacted condition. In area B, the general trend of variation of gravity anomaly is appeared to be high anomaly in northern part and decrease to the southern part. This is well matched with the prelandfill topography of the landfill site. The southern part of area B is located in the center of valley and its present surface is comparatively rugged, which may be due to the differential settlement of deep burried waste. The thickness of waste in area C is relatively thin, but the gravity anomaly appears to be low. Considering the present condition of surface, it can be inferred that low density wastes such as leftover food were mainly filled in this area. Area D, as in the case of area B, shows gravity anomaly that has close relation with the prelandfill topography. Magnetic data show the variation of total field intensity varies in the range of 46600~51000 nT, and reach maximum anomaly of 4400 nT. The overall pattern of magnetic anomaly well reflects the distribution of magnetic materials in the landfill. The result of VLF survey reveals several low resistivity zones, which may serve as underground passages for contaminant flow, in the area C located near the small Village.

  • PDF

Gravity, Magnetic and VLF explorations in the ubong industrial waste landfill, Pohang (포항 유봉산업 폐기물 매립지에서의 중력, 자력, VLF 탐사)

  • 권병두
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.177-187
    • /
    • 1999
  • Gravity, magnetic and VLF surveys were conducted to investigat the structural stability and hazards associated with the Ubong landfill in Pohang City, which has been built to dump industrial wastes. In 1994, the collapse of a bank happened in the 6th landfill site due to sudden heavy rain, and a large quantity of waste materials flowed out to the nearby landfill sites, factories and roads. We used $10{\times}10m$ resolution DEM data for gravity reductions. The maximum variation of the terrain effect in the survey area is about 0.5 mgal and the terrain effect is large in the vicinity of bank boundary. The Bouguer gravity anomaly map shows the effect due to the variatino of thickness and type of waste materials. The small negative gravity anomaly increases from the 9th site to the 6th site. The small negative gravity anomaly of the 9th site reflects the relatively shallow dumping depth of average 14.5 m in this site and increased density of waste materials by the repeated stabilization process of soil overlaying. The 6th site is located at the center of the former valley and rainfall and groundwater are expected to flow from south-east to north-west. Therefore, considering the previous accident of mixing waste and bank materials at the north-west boundary of the landfill, there may be some environmental problems of leakage of contaminated water and bank stability. The complex inversion technique using Simulated annealing and Marquardt-Levenberg methods was applied to calculate three-dimensional density distribution from gravity data. In the case of 6th site, it is apparent that the landfill had been dumped in four sectors. However, most part of the 9th site and showed that high magnetic industrial wastes were concentrated in the 6th site. The result of magnetic survey showing low magnetic anomalies along the boundaries of two sites is similar to that of gravity data. The VLF data also reveals four divided sectors in the 6th site, and overall anomaly trend indicates the directio of former valley.

  • PDF

Evaluation of Optimal Performance of Hydraulic Barriers in Offshore Landfill using Seepage-Advection-Dispersion Analysis under Steady State Flow (정상류하 침투·이류 분산 해석을 이용한 폐기물 해상최종처리장 차수시스템의 최적 성능 평가)

  • Hwang, Woong-Ki;Oh, Myoung-Hak;Kim, Tae-Hyung;Kim, Hyang Eun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.2
    • /
    • pp.61-68
    • /
    • 2018
  • This study was conducted to propose the optimum minimum requirement of cutoff system composed of the impermeable soil layer and vertical barrier in offshore landfill for prevention pollution leakage by seepage, advection, and dispersion numerical analyses under steady state. According to the study results, the minimum requirement of impermeable soil layer is below $1{\times}10^{-6}cm/s$ of hydraulic conductivity with more than 500 cm thickness or a system with equivalent cutoff effect. The minimum requirement of vertical barrier is below $1{\times}10^{-6}cm/s$ of hydraulic conductivity with more than 50 cm thickness or a system with equivalent cutoff effect. In addition, the vertical barrier should be embedded enough to seal securely with the impermeable soil layer for working cutoff effect.

Seepage-Advection-Dispersion Numerical Analysis of Barrier System of Offshore Rubble Mound Revetment Landfill Under Steady Flow (정상류 조건에서 경사식호안 해상폐기물매립장의 차수에 대한 침투이류 분산해석)

  • Hwang, Woong-Ki;Kim, Hyang-Eun;Kim, Tae-Hyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.97-106
    • /
    • 2019
  • This study was conducted to propose a reasonable requirement regulation of barrier system of rubble mound revetment offshore landfill for preventing contaminant leakage. The barrier is composed with bottom layer and side barrier. The bottom layer was assumed as impermeable clay layer and side barrier was composed with HDPE sheet (primary element) and mid-protection layer (supplementary element). Seepage-advection-dispersion numerical analysis has been conducted using SEEP/W and CTRAN/W programs under steady flow. As the results, the minimum required barrier regulations for hydraulic conductivity and thickness of the bottom layer were suggested. For side barrier, the extended length of HDPE sheet and the hydraulic conductivity of mid-protection layer were also suggested.