• Title/Summary/Keyword: Landfill gas

Search Result 237, Processing Time 0.02 seconds

Decomposition Characteristics of Municipal Solid Wastes in Lysimeter Without Leachate Discharge (침출수 무배출식 모형매립조를 이용한 도시폐기물 분해특성)

  • 류돈식;이해승;이찬기
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.2
    • /
    • pp.49-57
    • /
    • 2000
  • The objective of this study is to find solid waste decomposition in landfill without leachate discharge. This study was observed variation of landfill gas production rate and leachate for stabilization assessment, and using four sets of lysimeter as experimental apparatus. Soild waste decomposition was accelerated in without leachate discharge system by sufficient moisture for methane bacteria. And gas production rate was between 54.2ℓ/kg VS∼335.9ℓ/kg VS in each lysimeter. Generation time of methane gas was showed different in each lysimeter, but it was much faster than literature research. The time of stabilization phase were began as follows : L-1 400 day, L-2 350 day, L-3 170 day and L-4 70 day respectively. Decreasing times of BOD/COD ratio and C/N ratio were necessary more than literature research because organic matter was not discharge such as wash out.

  • PDF

Hydrogen Sulfide Removal in Full-scale Landfill Gas Using Leachate and Chelated Iron (침출수 및 철킬레이트를 이용한 실규모 매립가스 내 황화수소 제거)

  • Park, Jong-Hun;Kim, Sang-Hyoun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.51-56
    • /
    • 2019
  • $H_2S$ is a detrimental impurity that must be removed for upgrading biogas to biomethane. This study investigates an economic method to mitigate $H_2S$ content, combining scrubbing and aeration. The desulfurization experiments were performed in a laboratory apparatus using EDTA-Fe or landfill leachate as the catalyst and metered mixture of 50-52% (v/v) $CH_4$, 32-33% (v/v) $CO_2$ and 500-1,000 ppmv $H_2S$ balanced by $N_2$ using the C city landfill gas. Dissolved iron concentration in the liquid medium significantly affected the oxidation efficiency of sulfide. Iron components in landfill leachate, which would be available in a biogas/landfill gas utilization facility, was compatible with an external iron chelate. More than 70% of $H_2S$ was removed in a contact time of 9 seconds at iron levels at or over 28 mM. The scrubbing-aeration process would be a feasible and easy-to-operate technology for biogas purification.

Experimental Study of the Landfill Gas Fuelled Micro Gas Turbine Exhaust Gas Analysis (매립가스 마이크로가스터빈 배가스 분석에 관한 실험적 연구)

  • Park, Jung-Keuk;Hur, Kwang-Beom;Rhim, Sang-Gyu;Oh, Il-Hong;Lee, In-Hwa
    • New & Renewable Energy
    • /
    • v.7 no.3
    • /
    • pp.67-73
    • /
    • 2011
  • MGT fuelled by landfill gas was tested to asses feasibility of its exhaust gas application for $CO_2$ enrichment. The exhaust gas was analyzed during start-up and normal operation with different MGT load conditions. Due to the changes of air/fuel ratio and combustion mode, $O_2$, $CO_2$, CO and NOx concentration were varied within wide ranges during the MGT start-up. Especially, NOx emissioin level was increased up to 20.01 ppmv. Different tendencies of $O_2$, $CO_2$, CO and NOx concentrations were observed with MGT output changes. $O_2$ and CO concentrations were shown to be decreased and NOx and $CO_2$ concentrations were shown to have opposite trends. NOx emission level (0.8~1.88 ppmv) was very low compared to other types of combustion based power generation equipment. Unburned hydrocarbon emission level was substantially decreased with MGT load increase. Especially, $C_2H_4$ concentration was below the detection limit(0.2 ppmv) around the nominal load condition. The exhaust gas from landfill gas fuelled MGT system was shown to be feasible for $CO_2$ fertilization. Concentrations of major components were within or below the maximum allowable ranges.

The Analysis of LFG Composition with Respect to Malodorous Sulfur Compounds (환원황 화합물을 중심으로 한 매립가스의 조성에 대한 연구)

  • 김기현;오상인;최여진;전의찬;사재환;선우영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.1
    • /
    • pp.77-85
    • /
    • 2004
  • In this study, the concentrations of reduced S compounds (including hydrogen sulfide (H$_2$S); methyl mercaptan ($CH_3$SH); dimethyl sulfide (($CH_3$)$_2$S); carbon disulfide (CS$_2$); and dimethyl disulfide (($CH_3$)$_2$S$_2$) were determined from landfill gas (LFG) in three municipal landfill sites in the two cities of Gwang Ju (GJ) and Jeju (JJ), Korea. The S gas concentrations measured in these landfill sites were found to be dominated by H$_2$S with its mean concentration of 850 ppm from 10 LFG samples. Both absolute and relative dominance of H$_2$S was seen to be significant in most LFG samples, except those collected from very old and inactive landfills. Unlike the pattern of H$_2$S, other S gases were typically observed at much reduced concentration levels (a few ppm or less) as follows: DMS (3.5); $CH_3$SH (1.3); CS$_2$(1.2); and DMDS (0.02 ppm). If compared equally in mass concentration unit (mg m$^{-3}$ ), H$_2$S generally explained far above 90% of all S gas masses determined concurrently. Moreover, as its mass concentration commonly exceeds those of the major aromatic VOC components in LFG (like benzene and toluene), it appeared to be one of the most dominant gaseous components emitted as LFG in a quantitative sense.

Estimation of Landfill Gas Utilization in Old Landfill (사용 종료 매립지의 가스 활용 방안 평가)

  • Lee, Cheol-hyo;Jeon, Yeon-ho;Lee, Chae-young;Kim, Kyung;Lee, Hwan;Lee, Nam-hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.154-160
    • /
    • 2000
  • Landfill gas (LFG) utilization in old landfill was estimated using LFG models. The results showed that Scholl Canyon model best described the LFG generation. LFG was extracted more than the amount of natural production which caused air inflow from outside that resulted in dilution of methane concentration and increase of oxygen concentration. It was negative for the LFG utilization. Therefore, to use LFG, the plan of stabilization by LFG extraction should be ineffective. The use of LFG will have no problem if LFG is extracted less than the amount of natural production which was estimated based on modeling. At 8 years elapsed from landfill, now, the amount of natural landfill gas production was decreased sharply. The plan for using LFG from old landfill is feasible if LFG is used for the less than the amount of natural production as a small scale even though for the aspect of efficiency, it was less economic than use of LFG just after closing landfilling and it was helpful for stabilization of landfill by LFG extraction.

  • PDF

Application of Approved Baseline Methodologies for CDM Projects in Korea (Case Study : Landfill Gas-to-Electricity Projects) (청정개발체제(CDM) 베이스라인 방법론 적용에 관한 고찰 (사례연구 : 국내 매립지가스 발전사업))

  • Han, Seung-Ho
    • Journal of Environmental Policy
    • /
    • v.5 no.2
    • /
    • pp.69-93
    • /
    • 2006
  • This paper considers major three steps to arrive at accurate baseline emissions against which actual emission reductions attributable to CDM projects are accounted for. The first step is to select most likely baseline scenario among plausible alternatives. Then, the additionality of the project in question would be assessed by demonstrating that the project is not included in the baseline scenario selected. Finally, baseline emissions are calculated under the baseline scenario. In this paper, these three steps are integrated into a single flow chart in order to help understand the procedures for application of a baseline methodology better. Following the flow chart, a landfill gas-to-electricity project in Korea is analyzed as a case study. In consequence, this paper concludes that landfill gas-to-electricity projects in Korea have great potential for CDM projects, and it could also be concluded that data availability and reliability are a prerequisite for successful application of baseline methodologies for landfill gas projects to Korean specific situations.

  • PDF

Surface Flux Measurements of Methane from Lamdfills by Closed Chamber Technique and its Validation (플럭스챔버에 의한 매립지표면 메탄의 배출량 측정과 분석)

  • 김득수;장영기;전의찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.5
    • /
    • pp.499-509
    • /
    • 2000
  • Next to carbon dioxide, methane is the second largest contributor to global warming among anthropogenic greenhouse gases. Methane is emitted into the atmosphere from both natural and anthropogenic sources. Natural sources include wetlands, termites, wildries, ocean and freshwater. Anthropogenic sources include landfill, natural gas and oil production, and agriculture. These manmade sources account for about 70% of total global methane emissions; and among these, landfill accounts for approximately 10% of total manmade emissions. Solid waste landfills produce methane as bacteria decompose organic wastes under anaerobic conditions. Methane accounts for approximately 45 to 50 percent of landfill gas, while carbon dioxide and small quantities of other gases comprise the remaining to 50 to 55 percent. Using the closed enclosure technique, surface emission fluxes of methane from the selected landfill sites were measured. These data were used to estimate national methane emission rate from domestic landfills. During the three different periods, flux experiments were conducted at the sites from June 30 through December 26, 1999. The chamber technique employed for these experiments was validated in situ. Samples were collected directly by on-site flux chamber and analyzed for the variation of methane concentration by gas chromatography equipped with FID. Surface emission rates of methane were found out to vary with space and time. Significant seasonal variation was observed during the experimental period. Methane emission rates were estimated to be 64.5$\pm$54.5mgCH$_4$/$m^2$/hr from Kimpo landifll site. 357.4$\pm$68.9mgCH$_4$/$m^2$/hr and 8.1$\pm$12.4mgCH$_4$/$m^2$/hr at KwanJu(managed and unmanaged), 472.7$\pm$1056mgCH$_4$/$m^2$/hr at JonJu, and 482.4$\pm$1140 mgCH$_4$/$m^2$/hr at KunSan. These measurement data were used for the extrapolation of national methane emission rate based on 1997 national solid waste data. The results were compared to those derived by theoretical first decay model suggested by IPCC guidelines.

  • PDF

LFG Utilization in Hong Kong (Case study of the Shuen Wan and Urban Landfills)

  • Lloyd, Bryce;Chan, Louis;Nardelli, Ray;Sullivan, Kevin
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2001.05b
    • /
    • pp.85-91
    • /
    • 2001
  • This paper provides a case study of landfill gas (LFG) utilization fer direct use as process fuel, and for electrical power generation at restored landfills in the Hong Kong Special Administrative Region of China (HKSAR). The paper specifically covers the LFG utilization schemes, which are required under landfill restoration contracts at the Shuen Wan and Urban Landfills. These contracts provide for the restoration and aftercare of six landfills, and are administered by the Environmental Protection Department (EPD) of the Hong Kong Government. The LFG utilization scheme at the Shuen Wan Landfill incorporates the direct use of LFG by compressing and dehumidifying the LFG prior to conveyance through a 1.6-kilometer (1-mile) pipeline. The pipeline provides an alternate fuel source to naphtha during process heating for gas production at the Tai Po Gas Production Plant of the Hong Kong and China Gas Limited (HKCC). The LFG utilization scheme at the Jordan Valley Landfill (one of the Urban Landfills) beneficially uses the LFG as fuel for electrical power generation with reciprocating internal combustion engines. The LFG is compressed, cooled, and filtered prior to delivery to two engine/generator sets. This system provides power to operate the leachate pre-treatment plant, which processes leachate from all of the Urban Landfill sites. The case study will examine the technical and non-technical considerations, including harriers, for developing, designing and implementing the LFG utilization projects in Hong Kong. Specific regulatory considerations and external governmental agency approvals are discussed, including the requirement to register as a gas-producing utility. While the paper focuses on LFG utilization applications in Hong Kong, many of the considerations discussed are also applicable to development of LFG utilization in other regions of Asia.

  • PDF

Analysis of Flow Character and Gas Measurement from Final Cover Soil of sanitary Landfill (쓰레기 매립지 최종 복토층에서 가스 측정방법과 유출특성 해석)

  • 이해승
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.3
    • /
    • pp.75-86
    • /
    • 1998
  • This paper is going to show the way we can sample the landfill gases flowing out to the air through final cover soil by using an closed chamber in the field for a short time. In addition, we came to the following results through the application of model with actual measurements. 1) Analyzing changes of concentration in the chamber(H: 10-30cm) every 5 minutes, considering analysis time of gas chromatograph for an half hour. 2) The proportion of $CE_4$to $CO_2$changes rapidly near the surface of final cover soil by the influence of methane oxidation reaction. 3) When flux of landfill gas is F=$10^{-5}$mol/$\textrm{m}^2$.s), methane oxidation reaction has an influence on composition of gases, however there is little influence when F=$10^{-6}$ mol/($\textrm{m}^2$.s).

  • PDF

Effects of Gas Generation due to Biodegradation on Long-term Landfill Settlement (매립장의 생분해로 인한 가스발생이 장기 침하에 미치는 영향)

  • Ahn, Tae-Bong;Chin, Han-Gyu;Han, Woon-Woo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.1
    • /
    • pp.5-13
    • /
    • 2005
  • The conventional settlement prediction method is not appropriate to model landfill settlement because it is very complex phenomenon. Biodegradation needs to be considered for long-term settlement since landfills are comprised of various organic materials and soils. As organic materials are decomposed, they directly influences on settlement producing LFG(Landfill Gas). Therefore, mathematical settlement prediction model is proposed based on the generated gas volume. As one of stabilization methods, leachate recycling system is adopted to model tests. Two model tests; one is leachate recycled, the other is non-recycled, are componented with proposed model and analysed regarding gas generation and settlement. The proposed mathematical model requires correction coefficients of 1.4 and 1.7 for non-recycled model and recycled, respectively. The recycled model showed 22% increase of long-term settlement more than the non-recycled model.

  • PDF