• Title/Summary/Keyword: Land load

Search Result 470, Processing Time 0.031 seconds

Behavior Characteristics of Composite Reinforced Earth with Improved Soil Surface and Geogrid-reinforced Backfill (지반개량재 전면토체와 지오그리드 보강 배면토체로 형성된 복합보강토의 거동특성)

  • Bhang, In-Hwang;Kim, Tae-Heon;Kim, You-Seong;Kim, Jae-Hong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.12
    • /
    • pp.27-34
    • /
    • 2016
  • Many steepened slopes have become increasingly advantageous because of the desire to increase land usage and decrease site development costs. The proven concept of tensile reinforcement allows construction of slopes with far steeper face angles than the soils natural angle. Steepened slope face reinforced with improved soil can increase land usage substantially while providing a natural appearance. The paper presents composite reinforced earth with improved soil surface and geogrid-reinforced backfill. For the stability of the steepened slope, the behavior of the composite reinforced earth are validated and verified by case study and numerical analysis. The case study has performed to investigate the deformation of reinforce soil slope for 14 months. Its horizontal behavior by general vertical load shows within the safe range (0.5% of structure height). As a result of numerical analysis and case study, the reinforcement effect of the steepened slope technique using improved soil is sufficient to be constructed as reinforced soil slope.

An Experimental Study on the Reduction Effects of Shading Devices on Sky Radiant Cooling in Winter (차양장치의 겨울철 천공복사 냉각 저감 효과에 관한 실험적 연구)

  • Kim, Jin-Hee;Kim, Young-Tag;Lee, Soo-Yeol;Choi, Won-Ki
    • Land and Housing Review
    • /
    • v.12 no.1
    • /
    • pp.129-137
    • /
    • 2021
  • External shading devices are well known solar control devices that can help reduce the cooling load of commercial buildings. For this study, experiments were conducted to examine the feasibility of shading devices in reducing both the cooling and heating loads. The influence of sky radiant cooling during winter was verified for the external shading device, internal roller blind, and window. Results can be summarized as follows. The temperature difference between the inner and outer surfaces of the window with the external shading device was 11.8℃ compared to 14.6℃ for one without the external shading device. This 2.8℃ difference was due to heat exchange by sky radiation when the surface temperature of the shading device was lower than the ambient outdoor air temperature. The roller blind resulted in a lower temperature of 0.8℃ compared to the average temperature of the window's air cavity. This was due to heat exchange by sky radiation of the roller blind surfaces. Without shading devices, the outside surface temperature of the window is about 3℃ higher. The study also found that when external shading devices were installed on both the southwest and southeast sides, the outside surface temperature of the windows were lower on the southwest side than the southeast side.

Development of a Simplified Model for Estimating CO2 Emissions: Focused on Asphalt Pavement (CO2 배출량 추정을 위한 간략 모델 개발: 아스팔트 포장을 중심으로)

  • Kim, Kyu-Yeon;Kim, Sung-Keun
    • Land and Housing Review
    • /
    • v.12 no.2
    • /
    • pp.109-120
    • /
    • 2021
  • Global warming due to increased carbon dioxide is perceived as one of the factors threatening the future. Efforts are being made to reduce carbon dioxide emissions in each industry around the world. In particular, environmental loads and impacts during the life cycle of SOC structures and buildings have been quantitatively assessed through a quantitative method called Life Cycle Assessment (LCA). However, the construction sector has gone through difficulty in quantitative assessment for several reasons: 1) LCI DB is not fully established; 2) the life cycle is very long; 3) the building structures are unique. Therefore, it takes enormous effort and time to carry out LCA. Rather than estimating carbon emissions with accuracy, this study aims to present a simplified estimation model that allows owners or designers to easily estimate carbon dioxide emissions with little effort, given that rapid and rough decisions regarding environmental load reduction are to be made. This study performs the LCA using data from 25 road construction projects across the country, followed by multiple regression analyses to derive a simplified carbon estimation model (SLCA). The study also carries out a comparative analysis with values estimated by performing a typical LCA. The comparison analysis shows an error rate of less than 5% for 16 road projects.

The Application of Nature-Based Technologies for Addressing Urban Environmental Problems (도시 환경 문제를 해결하기 위한 자연 기반해법의 적용)

  • Haque, Md Tashdedul;Reyes, Nash Jett DG.;Lee, Jung-min;Guerra, Heidi B.;Jeon, Minsu;Choi, Hyeseon;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.24 no.4
    • /
    • pp.367-376
    • /
    • 2022
  • LID technologies are capable of mitigating the negative impacts of non-point source (NPS) pollution generated in different land uses. Apart from the increase in point and non-point pollutant generation, highly developed and paved areas generally affect microclimate conditions. This study evaluated both the efficiency of Low Impact Development (LID) facilities in treating NPS pollutant loads as well as the unit pollutant loads (UPL) generated in various urban features (such as parking lots and highways). This investigation also looked at how LID technology helped to alleviate Urban Heat Island (UHI) conditions. As compared to the typical unit pollutant loads in South Korea, the unit pollutant loads at Kongju National University were relatively low, because of no classes, limited vehicular transmission, and low anthropogenic activities during vacation. After receiving treatment from the LID facilities, the effluent pollutant loads were significantly decreased. The sedimentation in filtration mechanisms considerably reduced the pollutant fractions in the influent. Additionally, it was shown that LID facilities' mean surface temperatures are up to 7.2℃ lower than the nearby paved environment, demonstrating the LID systems reducing the UHI impact on an urban area.

Heavy Metals in Road Deposited Sediments and Control of Them in Urban Areas: A Review (문헌고찰에 의한 도시 지역 도로퇴적물의 중금속 특성 및 적정 관리방안)

  • Kim, Do Gun
    • Land and Housing Review
    • /
    • v.13 no.3
    • /
    • pp.125-140
    • /
    • 2022
  • Road Deposited Sediment (RDS) is the solids formed from the wear of road, wear of vehicles, exhausts, and the input of the emissions from various sources out of the roads. RDS is seriously polluted by organic matter, nutrients, and metals. RDS plays an important role as the sink and the transport medium of the associated pollutants because RDS can be carried to the adjacent water system via stormwater runoff. In this regard, the heavy metals in RDS were investigated based on the publications. The contents of the metals in RDS were highly variable. The concentration of Cr, Ni, Cu, Fe, Zn, As, Cd, and Pb in urban RDS in various regions was in a range of 3.16-3,410, 1.15-1,382, 20.2-9,069, 2,980-124,853, 81-2,550, 2.3-214, 0.19-21.3, and 15.21-1,125 mg/kg, respectively. The anthropogenic enrichment of the metals in RDS was confirmed by the high concentration of Cu, Zn, Cd, and Pb. The contents of the metals were higher in industrial and traffic areas than in residential areas, while they were generally increased with decreasing particle size. It is believed that this study's results would contribute to quantifying the metals' load via RDS and establishing control strategies.

Dissolution Monitoring of Geo-Soluble Mixtures (지반 소실 혼합재의 용해과정 모니터링)

  • Truong, Q. Hung;Byun, Yong-Hoon;Eom, Yong-Hun;Sim, Young-Jong;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.10
    • /
    • pp.111-122
    • /
    • 2009
  • Dissolution of some of geo-materials may yield the loss of the soil strength and the settlement of earth structures. The goal of this study is to monitor the several physical behaviors of soluble mixtures during dissolution. Sand-salt mixtures are used to monitor the meso to macro response including the settlements and shear waves. The mixtures of photoelastic and ice disks are used to monitor micro to meso behavior of soluble mixture including the void ratio, force chain, coordination number and horizontal force changes. In the sand-salt mixtures, shear waves are measured by using bender elements in conventional oedometer cells. In the photoelastic disk - ice disk mixtures, micro to meso response are measured by digital images and load cells. The shear wave velocity decreases at the initial stage of the dissolution, and then increases and approaches to asymptotic value. The larger dissoluble particle and the more random packing produces the severe horizontal fore change. After dissolution, the void increases and the coordination number decreases. This study demonstrates that the particle level behavior such as the changes of the force chain, void ratio, and coordination number affects the global behavior such as the change of the shear wave velocity and horizontal force of the system.

EMC and Unit Loads of Pollutants Generated from Tomato Cultivation during Rainfall (강우시 시설재배지역의 오염물질 유출 EMC 및 원단위 산정)

  • Jeon, Je Chan;Kwon, Koo Ho;Lee, Sang Hyeub;Lee, Jea Woon;Gwon, Heun Gag;Min, Kyung Sok
    • Journal of Wetlands Research
    • /
    • v.15 no.4
    • /
    • pp.555-566
    • /
    • 2013
  • Total maximum daily load enforced in 2004 is a program to evaluate the amount of pollutants by each land use type and manage to meet a target water quality of each waterbody. The many research to calculate runoff load of pollutants by landuse type have been studied. This study was conducted to calculate pollutants EMC, load and unit load in stormwater runoff generated from tomato growing area. Monitoring was conducted about 32 event during 4years and water quality parameters such as BOD, $COD_{Mn}$, TOC, TSS, TN, TP, $NH_3-N$, $NO_3-N$, $PO_4-P$ were analyzed at the laboratory. The average EMC were measured as follows: 9.6 BOD mg/L, 17.2 $COD_{Mn}$ mg/L, 5.5 TOC mg/L, 319.4 TSS mg/L, 4.4 T-N mg/L, 2.6 T-P mg/L, 0.5 $NH_3-N$ mg/L, 0.04 $NO_2-N$ mg/L, 2.6 $NO_3-N$ mg/L, 0.8 $PO_4-P$ mg/L. TN and TP is dichargeed as $NO_3-N$ and particle phosphorus type, respectively.

Analysis of the Utilization Characteristics of Electrical Power and Equipments on the Farms (농촌의 전력및 전기기기의 이용특성분석)

  • 박승우;류한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.4
    • /
    • pp.3943-3955
    • /
    • 1975
  • The purposes of this study are to evaluate the utilization characteristics of electrical power consumption, to grasp the present trends in the use of electrical equipments, to estimate the demand factor and load factor being held, and to evaluate the efficiency of electical uses for the recently electrified farms cultivating paddy rice. For the purposes, 109 sample farms located in eleven villiages electrified in six different years from 1968 to 1973, were chosen at random and investigated on 35 items concerning to electrical uses and wiring systems. The survey was carried out in 1975, in the vinicity of Suweon city. The results are summarized as follows: i) The average annual power consumption on sample farms is considered to be low, being 242.9 Kwh. in 1974, and varied according to the different electrified year and size of cultivated land, respectively. It has significant positive correlation to the area of farm, too. ii) Between the number of year of electrical uses and the power consumption, there is very significant positive correlation, which could be expressed as Y=43.041+16.108 X, where X represents the number of years of electrical uses. The annual increment of power consumption is much greater at the beginning of the electrification than that at the later years, its average being approximately 20 percent. However, it is recommended that any estimation of long-term increments should be carefully investigated. iii) The monthly power consumption varies considerably throughout a year, in which the heaviest farm load occurs in November. Observing the seasonal variation of consumption, the winter-time is the heaviest season while the summer is the lowest. The result implies house lighting is chief contribution to the present electrical consumption on the farms. Comparing the variation of monthly consumption ratios between the sample farms and industries, the electrical uses on the farms are independant of the industrial uses, and further, the agricultural uses are of inverse pattern to the farms from the results that there is negative correlationship between them, iv) The number of electrical equipments used on the farms are occupied chiefly by lighting sources. Next to the lighting sources, household appliances of small quantity and some motors are used. The mean electrical quantity is about 1, 127.4 watt, which corresponds to about 37.6 per cent to the contracted quantity. The composition of quantity is chiefly occupied by the electrical motor of about 1.5 hp., single-phased. The number of the annual utilization hours of each equipment is tabulated in Table IV-5. In contradiction to the high utilization of lighting sources and small household appliances, the motor is poorly used for approximately 22 hours in a year. v) More than 55 per cent of farms want to purchase new electrical equipments such as small household appliances and electrical motors in their number. The impulse of purchasing such items is stimulated by the contacts to the mass media and their knowledge on such equipments. Consequently, the increase of electrical uses could be prompted by such trials as education and demonstration. vi) The demand and load factors on the farms vary considerably according to the greater variation of the power consumption, daily or monthly. The daily demand factor is 22.4 per cent and load factor 18.6 per cent, while the annual demand factor is 1.3 per cent and load factor 70 per cent approximately. Therefore, the low efficiency of construction cost requires re-evaluation of the present contracted quantity of 3 Kw. or increase of electrical uses. vii) The electrical energy on the farms devoted chiefly to lighten the farm residences does not contribute to the farm incomes. Consequently, the cost of electrical consumption presses considerably upon the farm economy. Therefore, there is great need to build up the electrical uses on the farms through the development of new works and techinques to utilize any electrical equipments on the production of farm products. Further more, such the development should be related to increase the actual income of the farm consumers.

  • PDF

Evaluation of Runoff and Sediment Yield Reduction with Diversion Ditch and Vegetated Swale Using WEPP Model (WEPP 모형을 이용한 우회수로 및 식생수로의 유출 및 토사유출 저감 평가)

  • Choi, Jae-Wan;Shin, Dong-Seok;Kim, Ik-Jae;Lim, Kyoung-Jae
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.11
    • /
    • pp.863-873
    • /
    • 2011
  • It has been known that soil erosion caused by water has been a serious problem worldwide. Thus various modeling techniques for conservationists, farmers, and other land users have been developed and utilized to estimate effects of numerous site-specific Best Management Practices on soil erosion reduction. The physical process-based WEPP model would provide both temporal and spatial estimates of soil loss within small watersheds and for hillslope profiles within small watersheds. Thus, the WEPP watershed version was applied to study watershed, located at Jawoon-ri, Gangwon to simulate diversion ditch and vegetated swale with detailed input data set. The sediment yield and runoff reduction rates reduced by 5.8% and 29.6% with diversion ditch and 9.8% and 14.5% with vegetated swale. With vegetated diversion ditch, runoff and sediment yield could be reduced by 11.8% and 40.4%, respectively. Based on the results obtained in this study, the WEPP model would be an useful tool to measure runoff and sediment yield reduction and establish site-specific sediment reduction best management plan.

The Developed Study for SMPS to Protect the Noise and Inrush Current at LED Lighting Source (LED 광원에서 잡음 및 돌입전류 방지를 위한 스위칭모드 전원공급 장치 (SMPS) 개발 연구)

  • Chung, Chansoo;Hong, Gyujang;We, Sungbok;Yu, Geonsu;Kim, Mijin
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.577-582
    • /
    • 2016
  • This Study focused on the development of SMPS (Switching Mode Power Supply) to supply the constant votage and current nevertheless LED fluorescent Light generated the electric noise (with Harmonics) and Inrush current at instant time of turn-on and off. Recently, according to the Green policy in government, the LED fluorescent Lighter showed the rapidly increasing tend as indoor and outdoor Lighter. But, because of costs, LED fluorescent Light not considered and neglected the following items; power factor, efficiency, Harmonics and Inrush current. So, we are developed the SMPS about 3 key issues as follows: 1st, power factor and efficiency is 85%. 2nd, the switching noisy by harmonic is minimized. 3rd, the Inrush current at turn on and off time is reduced the minimum 0.3 A after $100{\mu}sec$ on turnon time. The proposed SMPS adjusted by LNK 409 driver (included the high frequency modulation function). Although, the developed SMPS maintained the about 85% of power factor and efficiency. but, the SMPS must be generated low heat by the variation of minute load current at switching timing. To improve the above weak point, the developed SMPS have the feedback monitoring circuit between input side and output side to maintain the power factor and efficiency. Also, we are studied the time-constant of control circuit to output the constant voltage and current nevertheless the load disturbance of LED lighting. The LED fluorescent Light of 46W is checked the above items.