• Title/Summary/Keyword: Lamp device

Search Result 159, Processing Time 0.027 seconds

A Water Tap Equipped with a Sterlization/Purification System of Non-contact UV-lamp (비접촉식 자외선램프를 이용한 살균/정화 수도꼭지)

  • Min, Kyoung-Won;Won, Jong-Heon;Lee, Hyun-Cheol;Han, Dong-Youl
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.3-7
    • /
    • 2007
  • Ultraviolet light(UV-C, wavelength: 200~280nm) is employed profitably for sterilizing drinking water. For most water serving apparatus such as a water purifier, a water cooler and heater, a coffee vending machine and etc., pre-sterilized water may be contaminated secondarily with bacillary inhabitation in a container before serving. In consideration of this problem, a household water tap which is equipped with a sterilization/Purification device in combination with non-contact UV-lamp, was designed to sterilize and purify water at the last outlet just before serving. Hopefully this simple but creative item may be commercialized for household and public use.

  • PDF

FPD 공정을 위한 램프하우스 열전달 특성 연구

  • Kim, Tae-An;Seo, Won-Ho;Kim, Jun-Hyeon;Kim, Yun-Je
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.10a
    • /
    • pp.132-137
    • /
    • 2006
  • With the help of the development of digital-multimedia in the middle of 1990's, FDP(Flat Panel Display) had attracted considerable attention. Collimation proximity exposure system that transfers the pattern on wafer or glass exactly using mask and light with appropriate wavelength is core process in semiconductor and liquid display element. The performances of resolution required in precision exposure system are evaluated by resolving power, depth of focus and storage area. Most of development has targeted on these three factors. The optical design including lamp house has played an important role on the performance of exposure process. In this study, we evaluate the cooling system, concerning on exposure device with mercury lamp among the kernel equipment for the production of LCD, to prevent the instability of lighting due to long term accumulation of excessive heating inside the lamp house. Numerical analysis is conducted on full-scale model. The characteristics of three-dimensional flow, pressure and temperature distribution on exposure system are graphically depicted to estimate the whole cooling system for lamp house and to establish the design criteria.

  • PDF

Design of the Driver of 7W Class LED Lamps as a Substitute for Incandescent Lamps (백열전구 대체용 7w급 LED 램프의 드라이버 설계)

  • Park, Young-San;Bae, Cherl-O
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.2
    • /
    • pp.235-240
    • /
    • 2010
  • In order to substitute incandescent lamps, a power supply device for 7W class LED lamps which are environmentally friendly and energy saving is designed LED lamps consist of a multitude of chip LED connected in parallel and series. 11ms it is necessary to supply LED lamps with DC voltage and current. However, when LED lamps are in use, they are connected directly to AC 220V. This is why we need to have AC/DC, DC/DC power converters including a control system of voltage and current. For this, a transformerless and simple LED lamp driver is designed 조ich can control the current and output voltage for LED string of LED lamp.

Effects of Light Trap Structure and Lamp Type on the Attraction of Chestnut Pests in an Orchard (밤재배원에서 유살등 구조 및 램프의 종류가 해충 유인력에 미치는 영향)

  • Kim, Young-Jae;Kim, Hyun Kyung;Kim, Gil-Hah
    • Korean journal of applied entomology
    • /
    • v.53 no.3
    • /
    • pp.217-223
    • /
    • 2014
  • The effects of insect capture were studied in a chestnut orchard using three different light traps (A, B, and C type) with various lamps. The mercury lamp trap captured 125 insect species, out of which 115 were chestnut pests. The B and C type light traps, comprising a Dulux-EL white lamp, were examined for their capturing ability. The type B trap attracted Coleopteran insects (83%), while type C captured Lepidopteran insects (73%). The mercury clarity lamp along with the type B light trap was most effective in attracting Curculio sikkimensis adults (mean, 9.8 adults), while the Dulux-EL lamp captured the highest number of Dichocrocis punctiferalis adults (mean, 10.2 adults) using the type C light trap. These results suggest that selection of the appropriate types of light traps and lamps based on the target pest species is critical in ensuring effective and eco-friendly control of the pest population.

Boron doping with fiber laser and lamp furnace heat treatment for p-a-Si:H layer for n-type solar cells

  • Kim, S.C.;Yoon, K.C.;Yi, J.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.322-322
    • /
    • 2010
  • For boron doping on n-type silicon wafer, around $1,000^{\circ}C$ doping temperature is required, because of the relatively low solubility of boron in a crystalline silicon comparing to the phosphorus case. Boron doping by fiber laser annealing and lamp furnace heat treatment were carried out for the uniformly deposited p-a-Si:H layer. Since the uniformly deposited p-a-Si:H layer by cluster is highly needed to be doped with high temperature heat treatment. Amorphous silicon layer absorption range for fiber laser did not match well to be directly annealed. To improve the annealing effect, we introduce additional lamp furnace heat treatment. For p-a-Si:H layer with the ratio of $SiH_4:B_2H_6:H_2$=30:30:120, at $200^{\circ}C$, 50 W power, 0.2 Torr for 30 min. $20\;mm\;{\times}\;20\;mm$ size fiber laser cut wafers were activated by Q-switched fiber laser (1,064 nm) with different sets of power levels and periods, and for the lamp furnace annealing, $980^{\circ}C$ for 30 min heat treatment were implemented. To make the sheet resistance expectable and uniform as important processes for the $p^+$ layer on a polished n-type silicon wafer of (100) plane, the Q-switched fiber laser used. In consequence of comparing the results of lifetime measurement and sheet resistance relation, the fiber laser treatment showed the trade-offs between the lifetime and the sheet resistance as $100\;{\omega}/sq.$ and $11.8\;{\mu}s$ vs. $17\;{\omega}/sq.$ and $8.2\;{\mu}s$. Diode level device was made to confirm the electrical properties of these experimental results by measuring C-V(-F), I-V(-T) characteristics. Uniform and expectable boron heavy doped layers by fiber laser and lamp furnace are not only basic and essential conditions for the n-type crystalline silicon solar cell fabrication processes, but also the controllable doping concentration and depth can be established according to the deposition conditions of layers.

  • PDF

Development of Vision system for Back Light Unit of Defect (백라이트 유닛의 결함 검사를 위한 비전 시스템 개발)

  • Han, Chang-Ho;Oh, Choon-Suk;Ryu, Young-Kee;Cho, Sang-Hee
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.4
    • /
    • pp.161-164
    • /
    • 2006
  • In this thesis we designed the vision system to inspect the defect of a back light unit of plat panel display device. The vision system is divided into hardware and inspection algorithm of defect. Hardware components consist of illumination part, robot-arm controller part and image-acquisition part. Illumination part is made of acrylic panel for light diffusion and five 36W FPL's(Fluorescent Parallel Lamp) and electronic ballast with low frequency harmonics. The CCD(Charge-Coupled Device) camera of image-acquisition part is able to acquire the bright image by the light coming from lamp. The image-acquisition part is composed of CCD camera and frame grabber. The robot-arm controller part has a role to let the CCD camera move to the desired position. To take inspections of surface images of a flat panel display it can be controlled and located every nook and comer. Images obtained by robot-arm and image-acquisition board are saved on the hard-disk through windows programming and are tested whether there are defects by using the image processing algorithms.

FABRICATION AND TEST OF AN OPTICAL GRISM (가시광선용 그리즘의 제작과 성능시험)

  • Lee, D.H.;Song, J.W.;Yoon, T.S.
    • Publications of The Korean Astronomical Society
    • /
    • v.28 no.3
    • /
    • pp.75-82
    • /
    • 2013
  • An optical grism for education is fabricated and tested. It is composed of a transmission grating as dispersion element and a prism as diffraction angle compensation device. The transmission grating is Edmundoptics #49-584(spatial frequency 600 lines/mm, dimension $50mm{\times}50mm$). The prism is the fused silica type with angles ($41.3^{\circ}$, $-48.7^{\circ}$, $-90^{\circ}$). The grism device is fabricated by bonding the transmission grating and the prism with an optical adhesive. The zig for assembling the grism, telescope and camera is composed of an aluminum tube, an aluminum disk ring and a T-ring camera adaptor. The fabricated optical grism spectrograph is tested in laboratory using Halogen lamp and Neon lamp with DSLR camera. And the grism assembled with reflector telescope is tested in a field using stellar light. The results show good agreements with design parameters. The wavelength coverage range of the grism is 250 nm at the un-deviated wavelength of 506 nm. The wavelength resolution is 0.11 nm/pixel.

Research for the Chemical Emergency Oxygen Supply and Lighting System for Aircraft Passengers (항공기 승객용 화학적 비상산소 공급 및 조명시스템에 대한 연구)

  • Kim, Young-In
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.30 no.2
    • /
    • pp.55-60
    • /
    • 2022
  • A PSU (passenger service unit) is mounted on passenger seats in a cabin on an aircraft and consists of a crew call lamp, a reading lights, an information display lamp, an emergency oxygen generator, and an emergency oxygen mask. It is a safety device for providing convenience to passengers and providing oxygen to passengers in an emergency. This paper is a study on emergency oxygen supply systems and light systems of aircraft PSUs and a control device was developed to operate the system by analyzing the B767-300 aircraft's PSU circuit diagram. And the temperature generated by the B777-200ER aircraft's emergency oxygen generator was also measured by operating it directly. Through this, precautions for explaining the operation of an oxygen mask in an emergency were described and improvements were presented. Data acquired in these research processes can be used in the future to develop aircraft PSU (passenger service unit) and emergency oxygen generators.

Development of Excitation Light Source for Photodynamic Diagnosis of Cancer (광역학적 암진단을 위한 여기 광원장치의 개발)

  • Lim, Hyun-Soo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.49-56
    • /
    • 2007
  • In this paper, the development of excitation light source is proposed for excitation light of the photodynamic therapy of cancer. Since the selection of the wavelength band of excitation light has an interrelation with fluorescence generation according to the selection of a photosensitizer. This study aims at designing and evaluating light source that can stably generate light with various kinds of wavelengths in order to make possible photodynamic diagnosis using a photosensitizer and diagnosis using auto-fluorescence. The light source device was a Xenon lamp and filter wheel, composed of an optical output control through iris and filters with several wavelength bands. It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-420nm, 430-480nm, 480-560nm. The transmission part of the light source was developed to enhance the efficiency of light transmission. To evaluate this light source device by KFDA#s technical reference, the characteristics of the light output and wavelength band were found.

Design of UV-ray Air Cleaner for Refrigerator and Its Sterilizing Effect (냉장고용(冷藏庫用) 자외선(紫外線) 공기(空氣) 청정기(淸淨機)의 설계(設計)와 살균(殺菌) 효과(效果))

  • Chun, Jae-Kun;Lee, Young-Jin;Kim, Kyung-Man;Lee, Hong-Won;Jang, Eu-Yung
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.171-173
    • /
    • 1993
  • UV-ray air cleaner consisted of 6 watt UV lamp and fan was developed to sanitize air of refrigerator. Light intensity of the lamp showed 5 times of D value of Bacillus subtilis and air velocity around the lamp in holding section was 0.7 m/s, giving 0.33s of the resident time. The performance of air cleaner was tested with bacterial contaminator sprayed with suspension of Bacillus subtilis and hey powder. The device effectively decreased 80% of the population of airborn spore after 100 min operation at room temperature.

  • PDF