• 제목/요약/키워드: Lamp current

검색결과 384건 처리시간 0.032초

Analysis of Effects on the performance of ceramic metal halide lamp by the loss of elements that have been filled in arc tube

  • 장혁진;양종경;이종찬;김우영;신익태;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.219-219
    • /
    • 2009
  • ceramic metal halide lamps are a subset of high intensity discharge lamps so named because of their high radiance These lamps weak ionized plasma in a fire-resisting but light transmissive wrapping by the corridor of current through atomic and molecular vapors. for commercial applications, For commercial applications, the conversion of electric power to light must occur with good efficiency and with sufficient spectral content throughout the visible (380-800 nm) to permit the light so generated to render colors comparable to natural sunlight. the purpose of this paper is to carry out a study on the variation of ageing time(2000 On/Off[hr]) on the performance of 150W CMH lamps. Experimental results show that the blackening by reacting W(tungsten)with I atomic has been created in the arc tube of an ageing lamp(2000 On/Off[hr]), the arc was unstable, and increased a lamp resistance made lamp voltage increases significantly. Also, Color temperature of the ageing lamp was moved by the losses of Ho with Dy atomics and by recombination of Na with I.

  • PDF

조명기기의 임펄스내전압 성능의 분석 (Analysis of Impulse Withstand Voltage Performance of Lighting Equipment)

  • 이복희;방평호
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.91-96
    • /
    • 2014
  • Modern electronic circuits are becoming more vulnerable to damage by surges, and it is required to improve the impulse withstand voltage performance of electrical and electronic equipment. This paper presents the impulse withstand voltage performance of lighting equipment connected to power lines, and the impulse withstand voltage tests for fluorescent lamp, LED lamp and halogen lamp were carried out according to the reference standards under normal service conditions. To conduct performance tests against lightning surge, a combination wave ($1.2/50{\mu}s$ voltage - $8/20{\mu}s$ current) was employed. The test surge was applied between lines or between line and ground of the specimen to be measured. The test surge was applied synchronized at the peak value of the positive and negative AC voltage waves. As a consequence, some specimens satisfied the impulse withstand voltage test criteria, but lighting equipment such as 36W fluorescent lamps, 5W and 5.5W LED lamps and 50W halogen lamp were damaged at the test voltage levels between power lines. It is needed to improve the qualities of lighting equipment to satisfy EMC immunity requirements of equipment for general lighting purposes.

Detection of Acute Toxoplasmosis in Pigs Using Loop-Mediated Isothermal Amplification and Quantitative PCR

  • Wang, Yanhua;Wang, Guangxiang;Zhang, Delin;Yin, Hong;Wang, Meng
    • Parasites, Hosts and Diseases
    • /
    • 제51권5호
    • /
    • pp.573-577
    • /
    • 2013
  • A loop-mediated isothermal amplification (LAMP) assay allows rapid diagnosis of Toxoplasma gondii infection. In the present study, the LAMP assay was evaluated using blood from both naturally and experimentally infected pigs. The sensitivity of the LAMP assay was compared with that of Q-PCR. Both assays detected T. gondii in the blood of experimentally infected pigs, with 100% agreement. In infected blood samples, the parasite was detected as early as 2 days post-infection and reached a peak in 3-5 days. In 216 field serum samples, the detection rates of LAMP and Q-PCR assays were 6.9% and 7.8%, respectively. This result indicates that the sensitivity of the LAMP assay was slightly lower than that of the Q-PCR assay. However, the LAMP may be an attractive diagnostic method in conditions where sophisticated and expensive equipment is unavailable. This assay could be a powerful supplement to current diagnostic methods.

개선된 밸리필과 밸리용 승압형 변환기를 결합한 고역률 형광등용 전자식 안정기 (A Unity Power Factor Electronic Ballast for Fluorescent Lamp having Improved Valley Fill and Valley Boost Converter)

  • 윤용식;채균;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2002-2006
    • /
    • 1997
  • A new PF correction topology, Improved Valley Fill (IVF) with Valley Boost Converter (VBC) used in the electronic ballast for fluorescent lamp is presented. The IVF can adjust the valley voltage higher than half the peak line voltage. Hence, there is no pulsating line current around the line voltage peak, PF and THD are significantly improved. The VBC is added to the IVF to achieve unity PF and to increase the valley voltage. The measured PF and THD for a prototype electronic ballast are 0.997 and 5%, respectively, and the lamp current CF is as low as 1.5

  • PDF

Development of New Cancer Therapy and Its Physics

  • Oh, Hung-Kuk;Jeong, Jin-Ha
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2001년도 춘계학술대회 논문집
    • /
    • pp.147-155
    • /
    • 2001
  • Nasucon lamp and Russian ones, which are coated with some special materials on the glass bulb, gave good clinical results for a cancer therapy. They are experimentally studied with Automatic Bioelectric Response Recorder on the six placements of the electrodes (two feet, two hands and two foreheads). They reduced the current rather than the control (natural) state. However infrared lamp and Chinese God light did not reduced the value current. Hemoglobin in blood. Brown gas, Ti$_3$SiC$_2$ and Nasucon have planar crystallizing $\pi$-bonding bonding layer and covalent bonding one in sequence commonly and thus the alternating magnetic fields are protected. Nasucon lamp and Russian ones utilized electric bulbs in order to generate alternating magnetic fields and to produce absorbing force.

  • PDF

용량성 결합을 고려한 CCFL 병렬 구동 (Parallel Operation of CCFLs Considering on Capacitive Coupling)

  • 박정오;김철진;박현철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1007-1009
    • /
    • 2008
  • This paper presents an architecture for driving multiple paralleled cold cathode fluorescent lamps (CCFLs) for back lighting applications. The key to the architecture is a proposed capacitive coupling approach for lamp ignition. This system is consist of a flyback converter, a single inverter to drive multiple lamps and conductive floating reflector. The topology is capable of driving a number of parallel lamps with independent accurate lamp, current regulation and improving cost effectiveness with significant reduction in size and weight, compared to typical high frequency ac ballast. Experimental demonstration results for ten of parallel CCFLs with simultaneous ignition. This like the EEFL it will be able to use the CCFL is the thing. Also, it investigates the effect where the leakage current goes mad to the Lamp.

  • PDF

고주파 전자식 안정기의 새로운 제어방법 (A New Control Method for The High Frequency Electronic Ballast)

  • 오덕진;김희준;조규민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.746-749
    • /
    • 2002
  • This paper presents a new control method for the high frequency electronic ballast which is operated with raw rectified dc link using diode bridge. For the commercial electronic ballast, proper ac input power factor and crest factor of the lamp current are required. The most ballast, therefore, has a active or passive power factor collection (PFC) circuit. With the proposed method, it can be achieved simultaneously that grater than 0.9 of input power factor and less than 1.85 of lamp current crest factor without any PFC circuit. In this paper, the proposed ballast control scheme and the experimental results for the application to the fluorescent lamp are described.

  • PDF

백열전구 복사열에 의한 미송판의 발화 임계거리 및 발화시간 예측 (Predicting of Ignition Time and Critical Distance for Ignition of Douglas fir by Radiant Heat of Incandescent Lamp)

  • 이흥수;김두현
    • 한국안전학회지
    • /
    • 제31권2호
    • /
    • pp.18-25
    • /
    • 2016
  • The incandescent lamp is an electric light fixture with a tungsten filament heated to a high temperature, by passing an electric current through it, until it glows with visible light. The hot filament is protected from oxidation with a glass bulb that is filled with inert gas. The incandescent lamp has fire risk when combustible materials are close to its glass bulb. Because its lamp has the property which converts 90~95 percents of the electric power to heat energy. 2015 national fire statistics show that fires caused by lighting fixtures were 652 cases, and incandescent lamps(44 cases) and halogen lamps(53 cases) accounted for 15 percents in those of high heating light fixtures. Since incandescent lamp fires account for about 45 percents in the high heating light fixture, we could not overlook the fire risks by the incandescent lamp. Although many studies related with those have been conducted, incandescent lamp fires are continuously occurred. This study was carried out to study the fire risk of ignition of wood due to radiant heat of incandescent lamp. Radiant heat flux of the incandescent lamp was predicted by applying point source model, and critical distance for ignition of wood was calculated by applying integral model. The results from this study could applied to fire prevention activities related to light bulb, and it could be used in fire cause investigations related to radiant heat of incandescent lamp.

Study of Fuzzy Control Algorithm of Security Alarm System and Integrated System with PIC-Emergency Lamp Controller

  • Yoon, Suk-Am;Park, Chong-Bock;Yoon, Hyung-Sang;Choi, Jang-Gyun;Cha, In-Su;Kim, Won-Bae;Cho, Myung-Hyun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.410-413
    • /
    • 1998
  • In this paper, we present the method that improve alarm security system using the electronic circuits added the emergency lamp by our proposed Algorithms. In conventional method the emergency lamp of warning & alarm system didn't work perfectly its performance because of battery with short life. For improving this problem we, using Peripheral Interface Controller IC, designed the circuit added the emergency lamp for an warning & alarm system and for prevention against stopping the electric current, and compared our proposed method with conventional method. By designing the circuit to stop up over charge we can extend life of battery, use for a stoppage of electric current in emergency and according to the lightness around. Therefore we are very convenient and profitable in our life. In the future we will study the method to lower the cost of architecture for practical utilization.

  • PDF

아크튜브내의 구성물 손실이 세라믹 메탈 핼라이드 램프의 특성에 미치는 영향분석 (Analysis of the Effect on the Performance of Ceramic Metal Halide Lamp by the Loss of Elements that have been Filled in Arc Tube)

  • 장혁진;양종경;박대희
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2446-2452
    • /
    • 2009
  • A Ceramic Metal-halide lamp is achieved by adding multiple metals to a basic mercury discharge. Because the vapor pressure of most metals is very much lower than mercury itself, metal-halide salts of the desired metals, having higher vapor pressures, are used to introduce the material into the basic discharge. The metal compounds are usually polyatomic iodides, which vaporize and subsequently dissociate as they diffuse into the bulk plasma. Metals with multiple visible transitions are necessary to achieve high photometric efficiency and good color. Compounds of Sc, Dy, Ho, Tm, Ce, Pr, Yb and Nd are commonly used. The maximum visible efficacy of a Ceramic Metal Halide lamp, under the constant of a white light source, is predicted to be about 450lm/W. This is controlled principally by the chemical fill chosen for a particular lamp. Current these lamps achieve 130lm/W and these life time are the maximum 16,000[hr]. So factors of performance lower are necessary to improve lamp performance. In this paper, we analyzed factors of performance lower by accelerated deterioration test. The lamp was operated with short duration turn-on/turn-off procedure to enhance the effect due to electrode sputtering during lamp ignition. The tested lamp that was operated with a longer turn-on/off(20/20 minutes) showed blackening, changed distance between electrodes and lowered color rendering & color temperature by losses of Dy at 421.18nm, I at 511nm, T1 at 535nm and Na at 588nm compared with the new lamp.