• Title/Summary/Keyword: Lamp current

Search Result 384, Processing Time 0.024 seconds

A Single-Stage LED Tube Lamp Driver with Input-Current Shaping for Energy-Efficient Indoor Lighting Applications

  • Cheng, Chun-An;Chang, Chien-Hsuan;Cheng, Hung-Liang;Chung, Tsung-Yuan;Tseng, Ching-Hsien;Tseng, Kuo-Ching
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1288-1297
    • /
    • 2016
  • This study proposes a single-stage light-emitting diode (LED) tube lamp driver with input-current shaping for T8/T10-type fluorescent lamp replacements. The proposed AC-DC LED driver integrates a dual-boost converter with coupled inductors and a half-bridge series-resonant converter with a bridge rectifier into a single-stage power conversion topology. This paper presents the operational principles and design considerations for one T8-type 18 W-rated LED tube lamp with line input voltages ranging from 100 V rms to 120 V rms. Experimental results for the prototype driver show that the highest power factor (PF = 0.988), lowest input current total harmonic distortion (THD = 7.22%), and highest circuit efficiency (η = 92.42%) are obtained at an input voltage of 120 V. Hence, the proposed driver is feasible for use in energy-efficient indoor lighting applications.

Electronic Ballast with Constant Power Output Controller for 250W MH Lamp

  • Jung Dong-Youl;Park Jong-Yeon
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.332-337
    • /
    • 2006
  • In this paper, an electronic ballast was developed to control a 250W metal halide lamp. To avoid acoustic resonance phenomenon, we calculated the acoustic resonance band and determined the driving frequency from 70kHz to 100kHz. Due to the switching loss of MOSFET, many problems are caused in the inverter circuit during lamp lighting, so we reduced the loss by connecting the capacitor that minimizes the magnitude of the impulsive voltage. In this paper, the main point of research is to find the methods to operate the lamp on the rated output power. After detecting the current and the voltage of the lamp, we changed the driving frequency by adjusting the DC voltage level of the VCO input.

Development of Selecting Equipment for Damage of Street Lamp Circuit (가로등 회로 손상 선별 장치 개발)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2294-2297
    • /
    • 2011
  • The research which sees currently inspects the damage of the street lamp circuit which is used selectively the diode for developed. Street lamp diagnosis is developed will grasp the lighting presence of LED indication systems and will be able to inspect selectively. The case where the street lamp will not light, will be able to indicate with the relationship of LED putting out lights where the breakdown should have occurred in which part. Circuit produced PCB borads and the system will be able to confirm the breakdown point location of street lamp individual grade developed.

A New End of Lamp Life Detection Method for Fluorescent Lamps (새로운 형광램프 수명말기 현상 검출 방법)

  • Cho, Gye-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.1-5
    • /
    • 2007
  • This paper presents the new detection method for the end of life on fluorescent lamps. At the end of lamp life, the lamp voltage and current asymmetrically increase and decrease more than normal state. If the ballast system does not have the protection function especially for T4 and T5 lamps, we may see the melting socket which is connected to the end of the lamp. To protect from this kind of abnormal status is the most important thing in the ballast system that has very old lamps.

Super Thin 0.25 mm Thickness White LED Lamp with PCB Type Lead Frame (0.25 mm 초박형 두께를 가지는 회로기판형 리드프레임 백색 LED 램프)

  • Yu, Soon-Jae;Kim, Do-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.34-37
    • /
    • 2010
  • 0.25 mm thickness super thin surface mounted device LED Lamp is developed with PCB type lead frame in which BT (Bismaleimide Triazine) resin is used. BT resin is removed by a laser beam in order to reduce the thermal resistance below $1\;^{\circ}C/W$ and transfer molding is used with silicone. Compared to conventional 0.4 mm thickness LED lamp, the developed LED lamp can be derived in high current and the luminance of the LED lamp is increased up to 240 mA.

The Algorithm of Life Time Diagnostics end Evaluating of Exchanges Time about High Pressure Sodium Vapor Lamp Using the LabVIEW Software Package (LabVIEW 소프트웨어 패키지를 이용한 고압나트륨전등의 교환시점 및 수명진단 알고리듬)

  • Han, Tae-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.1-7
    • /
    • 2004
  • It is necessary for starting voltage to him on high pressure discharge lamp. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in Electric discharge tube, So accelerative electron collide against vapour atom and second electron is generated, And rapidly the current flow to Electric discharge tube. This paper showed that the life cycle and exchanges time for all electric discharge lamp was different according to each manufactures, This paper is proposed the evaluating algorithm of exchanges time for high pressure sodium vapor lamp, used LabVIEW software package.

A study on the temperature distribution measurement of the high pressure mercury lamp (고압 수은등의 온도분포 측정에 대한 연구)

  • 손승현;김상용;김창섭;지철근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.35-40
    • /
    • 1990
  • Temperature distribution of high pressure mercury lamp has been mesured as a function of time using spectroscopic method. Sampling signal which is synchronized by lamp voltage was used to mesure temporal line intensity at each radius. To obtain radial temprature distribution, the mesured intensity was transformed into radial line intensity by Abel's formula. Absolute temperature profile was calculater from relative intensities of spectral lines as a function of line and tube radius. The temperature profile is very similar to the electrical tube current profile.

  • PDF

HIGH FREQUENCY INVERTER FOR FLUORESCENT LAMP: MODELING SIMULATION AND REGULATION

  • Lee, G.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1100-1103
    • /
    • 1992
  • Two different resonance inverters used as fluorescent lamp ballast are based on the self oscillation at the series resonance of the circuit components. Each circuit is simulated on a computer in order to explain its function and the variation of the circuit variables for each of the circuit elements. Experimental results have bean carried out on the unsymmetrical scheme to indicate the voltage and current of the fluorescent lamp operation at the high frequency.

  • PDF

Ballast Design for HID Lamps with Automatic Identification (HID 램프를 자동 인식하는 안정기 설계)

  • Lee, Chi-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.10
    • /
    • pp.492-496
    • /
    • 2005
  • An electronic ballast with automatic identification between HPS and MH lamps is proposed in this paper. The behavior of the lamp impedance is studied at both cold-starting and warm-starting. Lamp identification is carried out by taking into account the rate of impedance changing at constant current driving mode just after ignition. The ballast consists of 8-bit microcontroller and LCC resonant inverter.

Protection Circuits in Flat Fluorescent Lamp(FFL) Backlight Inverter (LCD 백라이트용 면광원 램프 구동용 인버터 보호회로에 관한 연구)

  • Hur, Jeong-Wook;Lim, Sung-Kyoo
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1067-1068
    • /
    • 2008
  • An inverter for driving flat fluorescent lamp(FFL) with various protection circuits using micro controller(Micom) is proposed in this paper. The inverter will be shut down if the fault operating conditions such as open lamp, over current and over voltage are detected.

  • PDF