• Title/Summary/Keyword: Lamp

Search Result 2,687, Processing Time 0.03 seconds

Electrical and Optical Characteristics of Ceramic Metal Halide Lamp with Operating Electronic Ballast (세라믹 메탈할라이드 램프의 전자식 안정기 구동을 통한 전기적 광학적 특성에 관한 연구)

  • Kim, Nam-Goon;Yang, Jong-Kyung;Lee, Joo-Hoo;Jang, Hyeok-Jin;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2238-2243
    • /
    • 2008
  • The use of arc tubes made of ceramic material further enhanced some of the metal halide lamp's properties. These properties translate into higher efficacy with better color rendering, stable color through lamp long life. Recently, due to an increase in the application of the ceramic metal-halide lamp, the study for the property etc. according to Ballast's driving scheme and the study for arc tube material, optimization of gas and so on are being proceeded to improve the property of the lamp. Especially, to control ceramic metal-halide lamp, the vigorous study and practical use with respect to Electronic Ballast, which has been improved in the disadvantages of the conventional Magnetic Ballast are made. In this paper, Electrical, optical and thermal characteristics are analyzed by comparing magnetic ballast with electronic ballast.

A PSpice Model for the Electrical Ballast of HID Lamps (전자식 안정기를 위한 HID Lamp 시뮬레이션 모델)

  • 지윤근;김남준
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.1
    • /
    • pp.27-32
    • /
    • 2003
  • The thesis is used by PSpice circuit model to the characteristics of a fluorescent lamp modified form of he classical Cassie and Mayr equations in order to show the characteristics of HID(High-Intensity Discharge) Lamp. This is useful for applying high-frequency electric ballast for HID Lamp, and show that the result of experimentations and simulations, such as lamp rating, input voltage, high-frequency electric ballast which is using the ABM circuit model of the low pressure sodium lamp, come to the voltage and current wave.

Brightness special Quality change of wireless electrodeless fluorescent lamp by ferrite change (페라이트 변화에 따른 무전극 형광램프의 휘도 특성 변화)

  • Pack, Gwang-Hyoen;Yang, Jong-Kyung;Lee, Jong-Chang;Choi, Yung-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.171-176
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relative propertye of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. Coill turn was changed from 13th to 15th turn to recognize brightness change of lamp by winding number. Optical equipment that used in an experiment was used to measure brightness (LS-100). When an electrodeless fluorescent lamp was made using and T company's PE22, was it showed the highest brightness. As number of winding is increased the brightness increased, and starting characteristic became good.

  • PDF

Interior Light Environment and Building Energy Performance Analysis of LED and Fluorescent lamp installed in Office Building (LED램프를 적용한 사무소 건물의 실내조명환경 및 에너지 성능분석)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.466-471
    • /
    • 2009
  • Generally LED lamp has many advantages to compare with a general lamp, long life and no pollution matter like the mercury. Also it is excellence for color rendering and need to small consumption electric rower. However LED lamp has some disadvantages to compare to general fluorescent lamp and That is small light flux about 50% and narrow light distribution than fluorescent lamp. Therefore, to apply LED lamp in an office building, after analyze a illuminance distribution with an environment analysis and cooling, heating and light energy. The purpose of this study is to analyze light environment. light, cooling and heating energy simulation in Office building.

  • PDF

Dependence of Round type electrodeless lamp according to Ferrite shape (페라이트 형상에 따른 둥근형 무전극 램프의 의존성)

  • Kim, Nam-Goon;Yang, Jong-Kyung;Lee, Joo-Ho;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.465-466
    • /
    • 2007
  • In electrode-less lamp, The key point in creating an efficient light source based on RF discharge is to minimize the RF power loss in the RF coupler which for Anderson's type of RF lamp is due to losses in the ferrite core. This loss depends on the particular ferrite material, its size, geometry, frequency in this kind of inductive lamp shows that the correct choice of discharge current has a crucial effect on the core loss. In this study, we measured Ferrite temperature in normal state, then analyzed electrical and optical characteristics according to ferrite shape. We were able to know that was ferrite of the antenna had relate closely with temperature and luminous of the lamp. Also we appraised temperature and electrical, optical properties during turn on the lamp.

  • PDF

On the Photoelectric Effects of the Various Kinds of Light Source influencing to the Starting Characteristics of the Cold Cathode Type Discharge Tube (냉음극방전관의 기동특성에 미치는 각종광원에 의한 광전효과)

  • Chee, Chol Kon;Won, Chong Soo
    • 전기의세계
    • /
    • v.13 no.4
    • /
    • pp.10-15
    • /
    • 1964
  • It is well known that the starting characteristics of the cold cathode type discharge tube have photoelectric effects by the incident light from outside. After making the cold cathode type discharge tubes to be avaiable for popularizing, the present paper was devoted primaliry to a study of relations between the starting characterstics and photoelectric effects of discharge tube under the oight circumstances of day light, incandescent lamp, flouresent lamp, and mercury lamp we used frequently. The result of this investigation show that the photoelectric effects by flourescent lamp emitting short wave length having close ralation to the photoelectric effects is greater than incandescent lamp or day light, and also mercury lamp emitting shorter wave length than flourescent lamp indicates the greatest photoelectric effects.

  • PDF

Effects of Artificial Light Sources and Light Intensities in Subway Stations on the Growth of Hedera rhombea and Saxifraga stolonifera (지하철 인공광원과 광도에 따른 자생 송악(Hedera rhombea)과 바위취(Saxifraga stolonifera)의 생육변화)

  • Ju, Jin Hee;Bang, Kwang Ja
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.6
    • /
    • pp.73-80
    • /
    • 2008
  • This research investigated appropriate indoor light sources and light intensities for Hedera rhombea and Saxifraga stolonifera, which are shade-tolerant and cold-resistant indoor plants. Plants were grown in wood flames of 1 m in width${\times}$1 m in length${\times}$1 m in height. Light sources were fluorescent lamp, three wave fluorescent lamp and halogen lamp that are being used in most of the subway stations in Korea, and light intensities were 200 Lux, 700 Lux and 1,000 Lux. Results are as following. 1. Hedera rhombea Hedera rhombea heights did not show differences statistically as responses to light sources and light intensities. It, however, tended to be greater with an order of 1,000 Lux, 700 Lux and 200 Lux and halogen lamp, fluorescent lamp, and three wave fluorescent lamp. Number of branch increased under fluorescent lamp than under halogen lamp or three wave fluorescent lamp, and increased under higher light intensities. Number of leaf was higher with an order of three wave fluorescent lamp 1,000 Lux, fluorescent lamp 1,000 Lux and halogen lamp 1,000 Lux. Leaf shape became wider under low light intensities regardless of light sources. Chlorophyl contents in leaf were not significantly different under three wave fluorescent lamp and halogen lamp. However, the contents increased with an order of 200 Lux, 700 Lux and 1,000 Lux under fluorescent lamp. 2. Saxifraga stolonifera The plants were dead or declined under fluorescent lamp regardless of light intensities. When light intensities went under 200 Lux, Saxifraga stolonifera showed poor growth for all the light sources. Plant height, number of shoot, number of leaf, leaf width and leaf length have increased with an order of halogen lamp 1,000 Lux, three wave fluorescent lamp 1,000 Lux and three wave fluorescent lamp 700 Lux. Chlorophyl content was greater with an order of three wave fluorescent lamp 700 Lux, three wave fluorescent lamp 1,000 Lux and halogen lamp 1,000 Lux.

The Research of Electrical and Optical Properties for 24″ Flat Panel-Florescent Lamp (24″평판형광램프에 관한 전기적광학적특성연구)

  • 김수용;박승곤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.527-530
    • /
    • 2001
  • In this paper, the basic characteristics of flat fluorescent lamp using ultraviolet generate from gas discharge and powder type electrolyminescent display(P-ELD) using a phenomenon of the light emission eaused by the electrical field applied to phosphor are studied. The lamp is a simple structure with insulator layer, phosphor layer, and gas gap. Current(displacement current + discharge current) in flat fluorescent lamp using.

  • PDF

Optical performances of flat-lamp backlights for LCD applications

  • Ko, Jae-Hyeon;Yu, Mi-Yeon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1185-1188
    • /
    • 2008
  • The on-axis luminance gain as well as the viewing-angle characteristics of flat-lamp-based backlights have been analyzed for the first time. The on-axis luminance gain on each optical film in flat-lamp backlight was smaller than that obtained from the conventional tubular-lamp-based backlight. The origin of and possible solution to this problem were suggested.

  • PDF

A Stuty of Ignition Characteristics for Discharge Lamp (방전등 시동특성의 고찰)

  • Han, Soo-Bin;Park, Suck-In;Song, Eu-Gine;Jeoung, Hak-Guen;Jung, Bong-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.130-132
    • /
    • 2008
  • In the gas discharge lamp, starting procedure is composed of several physical discharge phases. The detailed phenomena are different according to lamp characteristics and ballasting method. This paper reviews starting methods in fluorescent lamp, and the starting procedure of HID lamp are investigated based on reviewed various waveforms.

  • PDF