• Title/Summary/Keyword: Lamp

Search Result 2,685, Processing Time 0.034 seconds

Manufacturing and Characteristics of the Electrodeless UV Lamp for Disinfection of the Sewage Effluent (하수 방류수 살균소독을 위한 무전극 UV 램프의 제조 및 특성)

  • Shin, Dong Ho;Lee, Yong Taek
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.570-575
    • /
    • 2005
  • In this study, we have manufactured electrodeless ultraviolet lamp which has a long life and a high degree of efficiency than the existing electrode UV lamp used in sewage effluent sterilization disinfection. First, we investigated change of UV intensity and temperature of lamp by activation materials. The best results for the dose response experiments were 250 minutes stabilizing to UV intensity of $300{\mu}W/cm^2$ and surface temperature $200{\sim}250^{\circ}C$ in Hg/Ind's weight ratio 95/5. When electrodeless UV lamp emits light for prolonged hours, surface temperature of lamp increases. therefore, temperature change is studied using a duplex lamp for cooling in actual sewerage process. Also, manufactured electrodeless UV lamp showed sterilization efficiency of more than 99.9% as result that experiment manufactured electrodeless UV lamp by E-coli. for sterilization disinfection of sewage effluent.

An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp (초정압 방전램프(UCD)를 적용한 안전조명 장치에 관한 연구)

  • Jeong, Poong-Gi;Kim, Young-Chul
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.41-51
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

Rapid and Visual Detection of Vibrio parahaemolyticus in Aquatic Foods Using blaCARB-17 Gene-Based Loop-Mediated Isothermal Amplification with Lateral Flow Dipstick (LAMP-LFD)

  • Hu, Yuan-qing;Huang, Xian-hui;Guo, Li-qing;Shen, Zi-chen;LV, Lin-xue;Li, Feng-xia;Zhou, Zan-hu;Zhang, Dan-feng
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.12
    • /
    • pp.1672-1683
    • /
    • 2021
  • Vibrio parahaemolyticus is recognized as one of the most important foodborne pathogens responsible for gastroenteritis in humans. The blaCARB-17 gene is an intrinsic β-lactamase gene and a novel species-specific genetic marker of V. parahaemolyticus. In this study, a loop-mediated isothermal amplification (LAMP) assay combined with a lateral flow dipstick (LFD) was developed targeting this blaCARB-17 gene. The specificity of LAMP-LFD was ascertained by detecting V. parahaemolyticus ATCC 17802 and seven other non-V. parahaemolyticus strains. Finally, the practicability of LAMP-LFD was confirmed by detection with V. parahaemolyticus-contaminated samples and natural food samples. The results showed that the optimized reaction parameters of LAMP are as follows: 2.4 mmol/l Mg2+, 0.96 mmol/l dNTPs, 4.8 U Bst DNA polymerase, and an 8:1 ratio of inner primer to outer primer, at 63℃ for 40 min. The optimized reaction time of the LFD assay is 60 min. Cross-reactivity analysis with the seven non-V. parahaemolyticus strains showed that LAMP-LFD was exclusively specific for V. parahaemolyticus. The detection limit of LAMP-LFD for V. parahaemolyticus genomic DNA was 2.1 × 10-4 ng/μl, corresponding to 630 fg/reaction and displaying a sensitivity that is 100-fold higher than that of conventional PCR. LAMP-LFD in a spiking study revealed a detection limit of approximately 6 CFU/ml, which was similar with conventional PCR. The developed LAMP-LFD specifically identified the 10 V. parahaemolyticus isolates from 30 seafood samples, suggesting that this LAMP-LFD may be a suitable diagnostic method for detecting V. parahaemolyticus in aquatic foods.

A Study on the Light Weight Hand Lamp for Explosion-Proof Type (휴대형 방폭등의 경량화 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • For lighting of dark and hazardous workplace such as compartment of ships under construction, workers should use hand lamps of explosion-proof type. However, the heavy weight of such lamps has prevented most impatient workers from using such types of lamps extensively. In this paper, we developed a light weight hand lamp of intrinsic safety type which reduced the weight a lot while maintaining or improving the lighting and explosion-proof function. We made a prototype which consisted of lamp fixture and high frequency power supply. Testing results show that the hand lamp meets well all the explosion-proof testing requirements of the Korea Occupational Safety and Health Agency. And more, we surveyed the explosion protection technology of a light weight hand lamp, and suggested the advantage/disadvantage to apply lighting of hand lamp about economical aspect.

Transmission Characteristics & Analysis of Ignition Voltage According to Its Conductor Length from the Ballast to the HID Lamp (HID램프와 안정기 사이의 전선 길이에 따른 이그니션 전압 전달특성 분석)

  • Bang, Sun-Bae;Kim, Chong-Min;Han, Woon-Ki;Im, Byeong-No;Jang, Mog-Soon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.3
    • /
    • pp.148-154
    • /
    • 2007
  • In this paper, characteristics of ignition voltage and current by wire length of HID(High Intensity Discharge) lamp circuit are analyzed. In the construction field, decision of the wire thickness for HID lamp circuit has the problems, and these are presented. Through transmit parameters, equivalent model of the ballast and HID lamp circuit was derived. The graph of voltage reduction about length between the ballast and the lamp is shown. The simulation of proposed model and experimental results are presented in order to validate the proposed method. The proposed model and graph can use to choose the proper length of wire between the ballast and the lamp in the field.

Motion recognition LED lamp technology using infrared ray sensor

  • Zouhaier, Muhamud
    • Korean Journal of Artificial Intelligence
    • /
    • v.4 no.1
    • /
    • pp.1-3
    • /
    • 2016
  • These days, citizens are interested in the energy. IT technology needs to develop and to make use of energy effectively and to save energy. In this study, motion recognition LED lamp was used to have good energy efficiency and to be made of environment friendly material. The purpose of development of the lamp was to add motion recognition to LED lamp. In this study, infrared ray sensor's distance measurement was used to develop LED lamp. Most of the lamps were used under dark environment, so that infrared ray sensor was used to perceive movement under dark environment. And, LED lamp with good efficiency and less power consumption was used to increase efficiency. Citizens were interested in perception of the movement to distinguish from conventional type of the lamps.

A Study on Optical Losses for Tubular LED Lamp's Components (직관형 LED램프의 구성부품별 광손실에 관한 연구)

  • Jeong, Hee-Suk;Park, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.1-8
    • /
    • 2011
  • The high efficiency tubular LED lamp has been developed. But, it occurs optical losses in consists of LED package, module, diffuser etc.. By Measuring the tubular LED lamp's luminous flux, we compared and analyzed about the effect of optical losses for each component and actually using measured luminous intensity distribution data, illuminance distribution was simulated by Relux. Optical losses are 24[%] from LED package to luminaire and the tubular LED lamp can be replaced with fluorescent lamp. In this paper, we could provide data for optimum lighting design by analyzing the optical characteristics for developing and propagating the tubular LED lamp.

A Study of The Novel External Electrode Fluorescent Lamp For High Optical Efficiency

  • Yoon, Ji-Su;Jung, Kyu-Bong;Kim, Hyung-Dong;Kang, Jae-Kyung;Kim, Jae-Bum;Jeong, Byoung-Koan;Ahn, Byung-Chul;Yeo, Sang-Deog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1412-1414
    • /
    • 2006
  • We study on the Electro Optical Properties of the EEFL (External Electrode Fluorescent Lamp) Backlight system is based on the lamp type characteristics and diameter of the lamp tube under the equal manufacturing of the lamps. In this contribution, through the analysis of the different lamp type and diameter of the lamp tube gain the effective luminance and reduce the lamp voltage from aspect in the electro optical properties with EEFL and LCD backlight system.

  • PDF

Development of Basking Neodymium Lamp Improving Reflector Globe and Rhenium Filament (레늄 필라멘트와 반사 글로브를 개선한 Basking Neodymium Lamp의 개발)

  • Eo, Ik-Soo;Yang, Hae-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.477-482
    • /
    • 2007
  • This paper examines and analyzes improvement of structure of bulb, increase of luminous efficiency through application of reflector globe through aluminum coating and development of 60[W] basking neodymium lamp through optimum insertion ratio of krypton gas and nitrogen gas. The results of this development shows that the life of the lamp was 7,200 hours, and the luminous flux was 620[1m]. This brings in superior color temperature and superior color rendering index, which allows us to use that lamp for agricultural or general purpose.

  • PDF

Reserch and development of metal halide lamp for LCD projector back light (LCD PROJECTOR BACK LIGHT용 METAL HALIDE LAMP의 연구 및 개발)

  • 박창식;정의선;이승수
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.39-46
    • /
    • 1995
  • Metal halide pamp for LCD projector back light is high technologlcal product with its consumption increasing by 30% a year according to LCD merchandise and we are whollydepending on imprtation. At this time exper iment. we achleved those results as below. 1. Reallzation of domestic production of 150W metal halide lamp for LCD progector back light and electrical ballatst. 2. Possession of self-designing and manufacturing technology of submlnlature metal halide lamp. 3. Possession of deslgning technology of electrlcal ballast for metal hallde lamp.

  • PDF