• 제목/요약/키워드: Laminar fracture

검색결과 15건 처리시간 0.024초

적층복합재료의 굽힘 파괴거동에 관한 준분자동력학적 해석 (Quasimolecular Dynamics Simulation for Bending Fracture Propagation of Laminar Composite Material)

  • 박준영;김영석
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1997년도 춘계학술대회논문집
    • /
    • pp.59-62
    • /
    • 1997
  • Recently, quasimolecular dynamics has been successfully used to simulate the deformation characteristic of actual size material. In quasimolecular dynamics, which is an attempt to bridge the gab between atomistic and continuum simulations, molecules are aggregated into large units, called quasimolecules, to simulate the large scale material behavior. In this paper, a numerical simulation using quasimolecular dynamics has been performed to investigate the laminar composite material fracture and crack propagation behaviors in bending process of laminar composite material which is made of fictitious materials. The simulation of the bending of laminar composite material has clarified the effects of strength of material at outer surface upon the fracture behviors of the specimen.

  • PDF

Predictable Factors for Dural Tears in Lumbar Burst Fractures with Vertical Laminar Fractures

  • Park, Jin-Kyu;Park, Jin-Woo;Cho, Dae-Chul;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권1호
    • /
    • pp.11-16
    • /
    • 2011
  • Objective : The purpose of the present study was to determine the incidence of dural tears and predictable factors suggesting dural tears in patients who had lumbar burst fractures with vertical laminar fractures. Methods : A retrospective review was done on thirty-one patients who underwent operative treatment for lumbar burst fractures with vertical laminar fractures between January 2003 and December 2008. All patients were divided into two groups according to existence of dural tears, which were surgically confirmed; 21 patients with dural tears and 10 patients without dural tears. Clinical and radiographic findings were analyzed for their association with dural tears. Results : Among a total of 31 patients, dural tears were detected in 21 (67%) patients. A preoperative neurological deficits and mean separation distances of the edges in laminar fractures were found to be the reliable factors of dural tears (p=0.001 and 0.002, respectively). Decreased ratio of the central canal diameter and interpedicular distance were also the reliable factors suggesting dural tears (p=0.006 and 0.015, respectively). However, dural tears showed no significant association with age, sex, level of injury, absence of a posterior fat pad signal, the angle of retropulsed segment, or site of laminar fracture. Conclusion : Our study of lumbar burst fracture combined laminar fracture revealed that dural tears should be ruled out in cases of a preoperative neurological deficits, wide separation of the laminar fracture, severe canal encroachment, and wider interpedicular distance.

Carbon/Phenolic 내열 복합재료의 기계적 특성 (Mechanical Properties of Carbon/Phenolic Ablative Composites)

  • 김평완;홍순형;김연철;예병한;정발
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.160-163
    • /
    • 1999
  • The mechanical properties and failure behaviour of carbon/phenolic composites were inverstigated by tension and compression. Carbon/phenolic composites were fabricated by infiltration of matrix into 8 harness satin woven fabric of PAN-based carbon fibers. The tensile and compressive tests were performed at 25℃ under air atmosphere and, at 400℃ and 700℃ under N₂ atmosphere. The tensile strengths of carbon/phenolic composites in with-laminar/0° warp direction were about 10 times higher than those in with-laminar/45° warp direction, which was analyzed due to a change of fracture mode from fiber pull-out by shear to tensile fracture of fibers. The fracture of carbon/phenolic composites in with-laminar/45° direction was analyzed due to delamination by buckling. Tensile and compressive strength of carbon/phenolic composites decreased to about 50% at 400℃, and to about 10% at 700℃ compared to that at room temperature. The main reason for the decrease of tensile or compressive strength with increasing temperature was analyzed due to a reduction of bond strength between fibers and matrix resulting from thermal degradation of phenolic resin.

  • PDF

C7 Fracture as a Complication of C7 Dome-Like Laminectomy : Impact on Clinical and Radiological Outcomes and Evaluation of the Risk Factors

  • Yang, Seung Heon;Kim, Chi Heon;Lee, Chang Hyun;Ko, Young San;Won, Youngil;Chung, Chun Kee
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권4호
    • /
    • pp.575-584
    • /
    • 2021
  • Objective : Cervical expansive laminoplasty is an effective surgical method to address multilevel cervical spinal stenosis. During surgery, the spinous processes of C2 and C7 are usually preserved to keep the insertion points of the cervical musculature and nuchal ligament intact. In this regard, dome-like laminectomy (undercutting of C7 lamina) instead of laminoplasty is performed on C7 in selected cases. However, resection of the lamina can weaken the C7 lamina, and stress fractures may occur, but this complication has not been characterized in the literature. The objective of the present study was to investigate the incidence and risk factors for C7 laminar fracture after C7 dome-like laminectomy and its impact on clinical and radiological outcomes. Methods : Patients who underwent cervical open-door laminoplasty combined with C7 dome-like laminectomy (n=123) were classified according to the presence of C7 laminar fracture. Clinical parameters (neck/arm pain score and neck disability index) and radiologic parameters (C2-7 angle, C2-7 sagittal vertical axis, and C7-T1 angle) were compared between the groups preoperatively and at postoperatively at 3, 6, 12, and 24 months. Risk factors for complications were evaluated, and a formula estimating C7 fracture risk was suggested. Results : C7 lamina fracture occurred in 32/123 (26%) patients and occurred at the bilateral isthmus in 29 patients and at the spinolaminar junction in three patients. All fractures appeared on X-ray within 3 months postoperatively, but patients did not present any neurological deterioration. The fracture spontaneously healed in 27/32 (84%) patients at 1 year and in 29/32 (91%) at 2 years. During follow-up, clinical outcomes were not significantly different between the groups. However, patients with C7 fractures showed a more lordotic C2-7 angle and kyphotic C7-T1 angle than patients without C7 fractures. C7 fracture was significantly associated with the extent of bone removal. By incorporating significant factors, the probability of C7 laminar fracture could be assessed with the formula 'Risk score = 1.08 × depth (%) + 1.03 × length (%, of the posterior height of C7 vertebral body)', and a cut-off value of 167.9% demonstrated a sensitivity of 90.3% and a specificity of 65.1% (area under the curve, 0.81). Conclusion : C7 laminar fracture can occur after C7 dome-like laminectomy when a substantial amount of lamina is resected. Although C7 fractures may not cause deleterious clinical outcomes, they can lead to an unharmonized cervical curvature. The chance of C7 fracture should be discussed in the shared decision-making process.

CFRP 적층쉘의 적층구성 및 곡률 변화에 따른 관통 특성 (Penetration Characteristics of CFRP Laminated shells according to Stacking Sequence and Curvature)

  • 조영재;김영남;양인영
    • 한국정밀공학회지
    • /
    • 제22권2호
    • /
    • pp.164-171
    • /
    • 2005
  • This study aims to examine an effect of stacking sequence and curvature on the penetration characteristic of a composite laminated shell. For the purpose, we manufactured specimens with different stacking sequences and curvatures, and conducted a penetration test using an air-gun. To examine an influence according to stacking sequence, as flat plate and curvature specimen had more plies, their critical penetration energy was higher, Critical penetration energies of specimen A and C with less interfaces somewhat higher than those of B and D with more interfaces. The reason that with less interfaces, critical penetration energy was higher is pre-impact bending stiffness of composite laminated shell with less interfaces was lower than that of laminated shell with more interfaces, but bending stiffness after impact was higher. And it is because interface, the weakest part of the composite laminated shell, was influenced by transverse impact. As curvature increases, critical penetration energy increases linearly. It is because as curvature increases, resistance to in-plane deformation as well as bending deformation increases, which need higher critical penetration energy. Patterns of cracks caused by penetration of composite laminated shells include interlaminar crack, intralaminar crack, and laminar fracture. A 0$^{\circ}$ply laminar had a matrix crack, a 90$^{\circ}$ply laminar had intralaminar crack and laminar fracture, and interface between 0$^{\circ}$and 90$^{\circ}$laminar had a interlaminar crack. We examined crack length and delamination area through a penetration test. For the specimen A and C with 2 interface, the longest circumferential direction crack length and largest delamination area were observed on the first interface from the impact point. For the specimen B and D with 4 interface, the longest crack length and largest delamination area were observed on the third interface from the impact point.

Fabrication of Nano-laminar Glass Composite Using Thin Flake

  • Kakisawa, Hideki;Minagawa, Kazumi;Halada, Kohmei
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.330-331
    • /
    • 2006
  • Fabrication of a nano-laminar ceramic composite by sintering thin ceramic plates was examined. Silver-coated glass flakes with a thickness of less than $1{\mu}m$ were consolidated by pulsed current sintering or hotpressing to obtain model composites. The samples sintered at the optimum conditions were fairly dense, and the flakes were aligned by uniaxial press. The metal coating remained on the flakes through the sintering process, and became an interface layer between the flakes. No crack propagation through the transverse direction of the lamellar was observed in the indentation test. The possibilities of high resistance against crack propagation was suggested.

  • PDF

C7 Posterior Fixation Using Intralaminar Screws : Early Clinical and Radiographic Outcome

  • Jang, Sang-Hoon;Hong, Jae-Taek;Kim, Il-Sup;Yeo, In-Sung;Son, Byung-Chul;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권2호
    • /
    • pp.129-133
    • /
    • 2010
  • Objective : The use of segmental instrumentation technique using pedicle screw has been increasingly popular in recent years owing to its biomechanical stability. Recently, intralaminar screws have been used as a potentially safer alternative to traditional fusion constructs involving fixation of C2 and the cervicothoracic junction including C7. However, to date, there have been few clinical series of C7 laminar screw fixation in the literature. Thus, the purpose of this study is to report our clinical experiences using C7 laminar screw and the early clinical outcome of this rather new fixation technique. Methods : Thirteen patients underwent C7 intralaminar fixation to treat lesions from trauma or degenerative disease. Seventeen intralaminar screws were placed at C7. The patients were assessed both clinically and radiographically with postoperative computed tomographic scans. Results : There was no violation of the screw into the spinal canal during the procedure and no neurological worsening or vascular injury from screw placement. The mean clinical and radiographic follow up was about 19 months, at which time there were no cases of screw pull-out, screw fracture or non-union. Complications included two cases of dorsal breech of intralaminar screw and one case of postoperative infection. Conclusion : Intralaminar screws can be potentially safe alternative technique for C7 fixation. Even though this technique cannot be used in the cases of C7 laminar fracture, large margin of safety and the ease of screw placement create a niche for this technique in the armamentarium of spine surgeons.

유리섬유 부직포가 삽입된 풍력 블레이드 인발 성형 스파캡 소재의 파괴인성 특성 평가 (Evaluation of Fracture Toughness Characteristics of Pultruded CFRP Spar-Cap Materials with Non-woven Glass Fabric for Wind Blade)

  • 김영철;주근수;박지상;이우경;강민규;김지훈
    • 풍력에너지저널
    • /
    • 제14권3호
    • /
    • pp.83-90
    • /
    • 2023
  • The purpose of this study is to evaluate the inter-laminar fracture toughness characteristics of CFRP pultrusion spar cap materials reinforced with non-woven glass fabric. Test specimens were fabricated by the infusion technique. A non-woven glass fabric and artificial defects were embedded on the middle surface between two pultruded CFRP panels. Double cantilever beam (DCB) and End Notched Flexure (ENF) tests were performed according to ASTM standards. Fracture toughness and crack propagation characteristics were evaluated with load-displacement curves and delamination resistance curves (R-Curve). The fracture toughness results were calculated by compliance calibration (CC) method. The initiation and propagation values of Mode-I critical strain energy release rate value GIc were 1.357 kJ/m2 and 1.397 kJ/m2, respectively, and Mode-II critical strain energy release rate values GIIc were 4.053 kJ/m2 for non-precracked test and 4.547 kJ/m2 for precracked test. It was found that the fracture toughness properties of the CFRP pultrusion spar-cap are influenced by the interface between the layers of CFRP and glass fiber non-woven.

Tc-99m 표지 항과립구항체 면역신티그라피(Tc-99m labeled antigranulocyte antibody immunoscintigraphy)를 이용한 척추압박골절의 원인질환 감별 (Vertebral Compression Fractures: Distinction Between Benign and Malignant Causes with Tc-99m Labeled Antigranulocyte Antibody Immunoscintigraphy)

  • 조인호;이형우;안상호;원규장;배장호;조수호
    • Journal of Yeungnam Medical Science
    • /
    • 제15권2호
    • /
    • pp.254-262
    • /
    • 1998
  • 골수의 손상정도률 민감하게 반영하는 Tc-99m 표지 항과립구항체 면역신티그라피를 이용하여 척추압박골절의 원인을 감별할 수 있는지를 알아보기 위하여, 척추압박골절 환자중에서 병리조직학적(수술 혹은 생검) 혹은 3개월 이상의 임상경과를 추적 관찰하여 원인이 밝혀진 16명의 환자를 대상으로 Tc-99m 표지 항과립구항체 면역신티그라피의 결과를 분석하였다. 16명의 환자중 외상이나 골다공증에 의한 압박골절 부위가 16부위 (8명), 전이암에 의한 압박골절이 3부위 (3명), 결핵에 의한 압박골절이 6부위 (5명) 이었다. 외상이나 골다공증과 같은 양성원인에 의한 척추압박골절 16 부위 모두 척추뿌리, 추궁판, 가시돌기의 섭취는 정상이었고, 척추체는 섭취저하가 7례, 섭취결손이 8례, 섭취정상이 2례에서 관찰되었다. 결핵에 의한 압박골절 6례에서 척추체의 섭취결손이 6례 모두, 척추뿌리의 섭취결손이 5례에서 관찰되었고, 가시돌기와 추궁판의 섭취결손은 발견되지 않았다. 전이암에 의한 3례의 경우는 2례에서 척추체, 척추뿌리, 추궁판, 가시돌기의 섭취결손이 보였고, 1례에서는 척추체와 가시돌기에만 섭취결손이 관찰되었다. Tc-99m 표지 항과립구항체 면역신티그라피의 단층영상에서 섭취결손부위를 평가함으로서 양성원인과 병적원인에 의한 척추압박골절의 원인의 감별에 도움이 될 수 있을 것으로 사료된다.

  • PDF