• 제목/요약/키워드: Laboratory wastewater

검색결과 356건 처리시간 0.025초

폐달걀껍질을 이용한 실험실폐수처리 (Treatment of Laboratory Wastewater Using Waste Egg Shells)

  • 김은호;정유진;김형석
    • 한국환경보건학회지
    • /
    • 제24권3호
    • /
    • pp.124-130
    • /
    • 1998
  • This study was to examine the utilization of waste egg snells for removal of heavy metals in laboratory wastewater. It was estimated that pH increasing formed heavy metals into a hydroxide and then settled to remove them. Removal rate of heavy metals were increased as increased dosage, low adsorbate concentration and passed reaction time. Average adsorption volumes of Cr, Cu, Mn and Pb per g were about 1.21 mg, 1.1 mg, 0.96 mg and 1.04 mg, respectively. If we reflected the adsorption capacity(k) and adsorption intensity(1/n) of Freundlich isotherm, we couldn't consider waste egg shells as a good adsorbent. It seemed that heavy metals contained in complex wastewater was removed to be influenced by inital pH, solubilities with passed reaction rime and competitive reaction.

  • PDF

Comparison of sericin produced through laboratory- and plant-scale extraction

  • Ye Eun Kim;Chun Woo Kim;In Chul Um
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제47권1호
    • /
    • pp.63-71
    • /
    • 2023
  • In this study, the structural characteristics of sericin recovered from wastewater released from the silk textile industry (Plant sericin) were comparatively analyzed with those of sericin extracted from a silkworm cocoon produced in a laboratory (Lab sericin). To prepare Plant sericin, ethanol was added to wastewater (i.e., a sericin aqueous solution) after the degumming process to remove nonprotein materials, affording a sericin precipitate. To prepare Lab sericin, nonprotein materials were removed from a silkworm cocoon and sericin was subsequently extracted from the cocoon. Lab sericin and Plant sericin exhibited similar solution viscosities, gel strengths, and crystallinity indices, indicative of the similar molecular weights (MWs) of the two sericin samples. In the case of sericin powder, Plant sericin was more crystalline than Lab sericin due to its treatment with ethanol. The findings of this study revealed that sericin recovered from industrial wastewater can be used equally as its MW is similar to that of sericin obtained through laboratory-scale extraction.

Optimization of membrane fouling process for mustard tuber wastewater treatment in an anoxic-oxic biofilm-membrane bioreactor

  • Chai, Hongxiang;Li, Liang;Wei, Yinghua;Zhou, Jian;Kang, Wei;Shao, Zhiyu;He, Qiang
    • Environmental Engineering Research
    • /
    • 제21권2호
    • /
    • pp.196-202
    • /
    • 2016
  • Membrane bioreactor (MBR) technology has previously been used by water industry to treat high salinity wastewater. In this study, an anoxic-oxic biofilm-membrane bioreactor (AOB-MBR) system has been developed to treat mustard tuber wastewater of 10% salinity (calculated as NaCl). To figure out the effects of operating conditions of the AOB-MBR on membrane fouling rate ($K_V$), response surface methodology was used to evaluate the interaction effect of the three key operational parameters, namely time interval for pump (t), aeration intensity ($U_{Gr}$) and transmembrane pressure (TMP). The optimal condition for lowest membrane fouling rate ($K_V$) was obtained: time interval was 4.0 min, aeration intensity was $14.6 m^3/(m^2{\cdot}h)$ and transmembrane pressure was 19.0 kPa. And under this condition, the treatment efficiency with different influent loads, i.e. 1.0, 1.9 and $3.3kgCODm^{-3}d^{-1}$ was researched. When the reactor influent load was less than $1.9kgCODm^{-3}d^{-1}$, the effluent could meet the third discharge standard of "Integrated Wastewater Discharge Standard". This study suggests that the model fitted by response surface methodology can predict accurately membrane fouling rate within the specified design space. And it is feasible to apply the AOB-MBR in the pickled mustard tuber factory, achieving satisfying effluent quality.

자철광 분말을 이용한 하수처리시스템의 질소, 인 제거효율에 관한 연구 (Study on the Removal Efficiency of Nitrogen and Phosphorus in Wastewater Treatment System Using Magnetite Powder)

  • 조은영;박승민;여인설;문정식;박주영;김종철;김양섭;박찬규
    • 한국유체기계학회 논문집
    • /
    • 제18권2호
    • /
    • pp.43-47
    • /
    • 2015
  • As water quality regulations have tightened, many studies to improve wastewater treatment efficiency have been performed. In this study, magnetite powder was used to maintain a high concentration of MLSS in lab-scale wastewater treatment system. After magnetite powder injection, MLSS concentration was above 8,000 mg/L and it was 3.2 times higher than control group(2,500 mg/L). In addition, nitrogen removal efficiency and phosphorus removal efficiency comparing with the control group was increased 20.5% and 11%, respectively.

Optimization of Anthraquinone Dyes Decolorization Conditions with Response Surface Methodology by Aspergillus

  • Ge, Yufeng;Wei, Bin;Wang, Siyu;Guo, Zhiguo;Xu, Xiaolin
    • Korean Chemical Engineering Research
    • /
    • 제53권3호
    • /
    • pp.327-332
    • /
    • 2015
  • A large amount of dye wastewater poses a threat to environmental safety. Disperse blue, an anthraquinone dye that is widely used in textile dyes, is difficult to degrade in wastewater. In this work, one fungus was screened according to the decolorization rate of disperse blue. The fungus was identified and named Aspergillus XJ-2 on the basis of its morphological characteristics and 18s rDNA. Response surface method was used to optimize culture conditions for A. XJ-2. The optimum values of obtained responses were as follows: temperature, $35^{\circ}C$; pH, 5.2; carbon-to-nitrogen ratio, 30:5.5; and rotation ratio, $175r{\cdot}min^{-1}$. Under optimized conditions, the decolorization rate of A. XJ-2 was up to 94.8% in 48 h.

전기응집을 이용한 2차 유출수의 질소.인 제거 공정 연구 (Removal of nitrogen and phosphorus of the secondary effluent by electro-coagulation)

  • 한송희;장인성
    • 상하수도학회지
    • /
    • 제26권4호
    • /
    • pp.579-589
    • /
    • 2012
  • To reduce extensive energy costs of the internal recycling for the purpose of denitrification in the advanced wastewater treatment, a post-treatment process using an electro-coagulation to treat nitrate in the secondary effluents is evaluated in this study. Removals of phosphorus and organics in the secondary effluents by the electro-coagulation were also evaluated to propose an alternative advanced wastewatert treatment process. A series of experiments of the electro-coagulation were carried out with the following 4 different samples: synthetic solution containing nitrate only, synthetic solution containing nitrate as well as phosphorus, secondary effluents from activated sludge cultivated in laboratory, and secondary effluents from real wastewater treatment plants. Removals of nitrate and phosphorus in the synthetic solution were 30 and 97 % respectively, which verified the feasibility of the process. Removals of nitrate, phosphorus and COD in the secondary effluents from the cultivated sludge in laboratory were 49, 90 and 19 % respectively. Removal efficiency of the total nitrogen, nitrrate, phosphorus and COD in the secondary effluent from real wastewater treatment plant were 50, 61, 98 and 80 % respectively. The removal of the total nitrogen was less than the nitrate as expected, which is due to the formation of ammonia nitrogen in the cathode. But the proposed scheme could be an energy saving and alternative process for the advanced wastewater treatment if further studies for the process optimization are carried out.

Application of Biotechnology to Wastewater Treatments in Japan

  • Mori, Tadahiro
    • 한국미생물생명공학회:학술대회논문집
    • /
    • 한국미생물생명공학회 1986년도 추계학술대회
    • /
    • pp.510.2-511
    • /
    • 1986
  • The biotechnology including genetic engineering is expected to be applied to various fields of wastewater treatments in order to promote biological reaction rate, to grade up the effluent quality and to advance the stability of microorganisms against temperature, pH and toxic substances. The current topics in Japan on application of biotechnology to wastewater treatment will be reviewed at the beginning of the presentation. Next, the research of Biochemical Engineering Laboratory is to be presented, especially focused on the following subjects ; (1) Application of genetic engineering to the investiation of heavy metal uptake by the resistant bacteria of Hg Cd or Zn. (2) Relationship between sulfate reducing bacteria and wastewater treatment, offensive odor and corrosion of sewer tranks.

  • PDF

중금속 함유 실험실 폐수처리를 위한 폐달걀껍질의 재활용 (Recycling of Waste Egg Shells for Treatment of Laboratory Wastewater containing Heavy Metals)

  • 김은호;김형석;성낙창
    • 유기물자원화
    • /
    • 제7권1호
    • /
    • pp.13-21
    • /
    • 1999
  • 본 연구에서는 폐기물의 재활용 측면에서 폐달걀껍질에 의한 중화능을 파악하는 동시에 중금속 제거 가능성을 고찰하였다. 폐달걀껍질 자체내에 Ca와 같은 알칼리성 성분으로 인하여 pH 상승효과가 탁월하며, 또한 폐수중의 중금속은 pH 상승으로 인하여 수산화물로 침전 제거되는 것으로 여겨진다. 폐달걀껍질은 응집 침전 및 흡착제로써 역할을 하기 때문에 주입량과 흡착질 농도에 영향을 받는 것으로 여겨진다. 흡착강도 1/n 값은0.35~0.44의 범위이며 Cu>Pb>Cr의 순으로 높게 나타났으나 흡착용량 k 값은 2.61~3.26의 범위이며 Pb>Cr>Cu의 순으로 높게 나타내었다.

  • PDF

Development of large bore superconducting magnet for wastewater treatment application

  • Liu, Huiming;Xu, Dong;Shen, Fuzhi;Zhang, Hengcheng;Li, Laifeng
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권1호
    • /
    • pp.13-16
    • /
    • 2017
  • Water issue, especially water pollution, is a serious issue of 21st century. Being an significant technique for securing water resources, superconducting magnetic separation wastewater system was indispensable. A large bore conduction-cooled magnet was custom-tailored for wastewater treatment. The superconducting magnet has been designed, fabricated and tested. The superconducting magnet was composed of NbTi solenoid coils with an effective horizontal warm bore of 400 mm and a maximum central field of 2.56T. The superconducting magnet system was cooled by a two-stage 1.5W 4K GM cryocooler. The NbTi solenoid coils were wound around an aluminum former that is thermally connected to the second stage cold head of the cryocooler through a conductive copper link. The temperature distribution along the conductive link was measured during the cool-down process as well as at steady state. The magnet was cooled down to 4.8K in approximately 65 hours. The test of the magnetic field and quench analysis has been performed to verify the safe operation for the magnet system. Experimental results show that the superconducting magnet reached the designed magnetic performance.

Removal of chromium from tannery wastewater by electrosorption on carbon prepared from peach stones: effect of applied potential

  • Ziati, Mounir;Khemmari, Fariza;Kecir, Mohamed;Hazourli, Sabir
    • Carbon letters
    • /
    • 제21권
    • /
    • pp.81-85
    • /
    • 2017
  • The objective of this study is the removal of chromium from tannery wastewater by electrosorption on carbon prepared from lignocellulosic natural residue "peach stones' thermally treated. The followed steps for obtaining coal in chronological order were: cleaning, drying, crushing and finally its carbonization at $900^{\circ}C$. The characterization of the carbon material resulted in properties comparable to those of many coals industrially manufactured. The study of the dynamic adsorption of chromium on the obtained material resulted in a low removal rate (33.7%) without applied potential. The application of negative potentials of -0.7 V and -1.4 increases the adsorption of chromium up to 90% and 96% respectively. Whereas a positive potential of +1.4V allows desorption of the contaminant of 138%.