• 제목/요약/키워드: Laboratory test

검색결과 6,897건 처리시간 0.037초

진단검사의학과의 검사분야별 기능과 검사흐름도에 대한 연구 (A Study on the Function and Workflow of Laboratory Sections for Clinical Laboratory Design)

  • 최창대;김영애;정태원
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권1호
    • /
    • pp.17-27
    • /
    • 2019
  • Purpose: Clinical laboratory in hospital has taken a great role in protection of chronic disease. as well as diagnosis and treatment, And laboratory layout has been considered by the management and laboratory section more than the function and workflow. Methods: So this study figures out the workflows of laboratory sections in the recently upgraded Laboratory Medicine, and searches the functional relationships and spatial block diagram between each disciplines as follows. Literature review and expert adviser has been conducted. Results: 1) Laboratory type of Laboratory Medicine is divided into routine and specialized laboratory according to the workflow by automated or specialized test. 2) The general workflow consists of specimen collection, specimen classification, test by discipline, test report, and specimen disposal. 3) Though the function of each laboratory section is very complicated and specific, the characteristics and the workflow can be shown in detail by each lab through [Figure 4], [Figure 5], [Figure 6], [Figure 7], and [Figure 8]. 4) Functional relationship diagram can be displayed to the adjacency and relation between each laboratory and support spaces. 5) The spatial block diagram could be presented as shown in [Figure 10], in which the emergency lab lay in front side, routine lab in the central open area, and specialized lab in the behind side. Implications: This study can be used as a useful data in planning and designing a Laboratory Medicine Department.

Carbonation depth estimation in reinforced concrete structures using revised empirical model and oxygen permeability index

  • Chandra Harshitha;Bhaskar Sangoju;Ramesh Gopal
    • Computers and Concrete
    • /
    • 제31권3호
    • /
    • pp.241-252
    • /
    • 2023
  • Corrosion of rebar is one of the major deteriorating mechanisms that affect the durability of reinforced concrete (RC) structures. The increase in CO2 concentration in the atmosphere leads to early carbonation and deterioration due to corrosion in RC structures. In the present study, an attempt has been made to modify the existing carbonation depth prediction empirical model. The modified empirical model is verified from the carbonation data collected from selected RC structures of CSIR-SERC campus, Chennai and carbonation data available from the reported literature on in-situ RC structures. Attempt also made to study the carbonation depth in the laboratory specimens using oxygen permeability index (OPI) test. The carbonation depth measured from RC structures and laboratory specimens are compared with estimated carbonation depth obtained from OPI test data. The modified empirical model shows good correlation with measured carbonation depth from the identified RC structures and the reported RC structures from the literature. The carbonation depth estimated from OPI values for both in-situ and laboratory specimens show lesser percentage of error compared to measured carbonation depth. From the present investigation it can be said that the OPI test is the suitable test method for both new and existing RC structures and laboratory RC specimens.

Shaking Table Model Test of Shanghai Tower

  • Lu, Xilin;Mao, Yuanjun;Lu, Wensheng;Kang, Liping
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.79-83
    • /
    • 2013
  • Shaking table test is an important and useful method to help structural engineers get better knowledge about the seismic performance of the buildings with complex structure, just like Shanghai tower. According to Chinese seismic design guidelines, buildings with a very complex and special structural system, or whose height is far beyond the limitation of interrelated codes, should be firstly studied through the experiment on seismic behavior. To investigate the structural response, the weak storey and crack pattern under earthquakes of different levels, and to help the designers improve the design scheme, the shaking table model tests of a scaled model of Shanghai tower were carried out at the State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University, Shanghai, China. This paper describes briefly the structural system, the design method and manufacture process of the scaled model, and the test results as well.

Scaling analysis of the pressure suppression containment test facility for the small pressurized water reactor

  • Liu, Xinxing;Qi, Xiangjie;Zhang, Nan;Meng, Zhaoming;Sun, Zhongning
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.793-803
    • /
    • 2021
  • The small PWR has been paid more and more attention due to its diversity of application and flexibility in the site selection. However, the large core power density, the small containment space and the rapid accident progress characteristics make it difficult to control the containment pressure like the traditional PWR during the LOCA. The pressure suppression system has been used by the BWR since the early design, which is a suitable technique that can be applied to the small PWR. Since the configuration and operating conditions are different from the BWR, the pressure suppression system should be redesigned for the small PWR. Conducting the experiments on the scale down test facility is a good choice to reproduce the prototypical phenomena in the test facility, which is both economical and reasonable. A systematic scaling method referring to the H2TS method was proposed to determine the geometrical and thermohydraulic parameters of the pressure suppression containment response test facility for the small PWR conceptual design. The containment and the pressure suppression system related thermohydraulic phenomena were analyzed with top-down and bottom-up scaling methods. A set of the scaling criteria were obtained, through which the main parameters of the test facility can be determined.

노후 콘크리트 포장 파손에 대한 현장조사 및 실내시험 방법 (Methodology of Field Investigation and Laboratory Test for Distresses of Old Concrete Pavements)

  • 이기상;이준혁;강민수;조남현;정진훈
    • 한국도로학회논문집
    • /
    • 제18권5호
    • /
    • pp.21-29
    • /
    • 2016
  • PURPOSES : The purpose of this study is to suggest a specific investigation guideline to decide priority of repairing old concrete pavements that pile up substantially. METHODS : In this study, a principle of division of homogeneous sections was proposed to reflect the characteristics of the pavement reasonably in the specific investigation results. In addition, a checklist and guideline of field investigation were suggested for the old concrete pavement sections, which require inspection toward their durability and structural performance. Furthermore, the items of laboratory test necessary to the old concrete pavement were suggested based on the existing laboratory test considering characteristics of the old concrete pavement. The present condition of the old concrete pavement could be analyzed by the test results. RESULTS : A method of division of homogeneous sections suitable for the specific investigation of the old concrete pavement was suggested. The proportions of distress severity of pavement sections were compared by distress type to figure out the present state of the old concrete pavement. Scaling, durability cracking (or alkali-silica reaction), and longitudinal spalling were selected as the most severe distress types. The detailed positions of the sections were also suggested. The checklist of the specific investigation was categorized by field survey and laboratory test, and its evaluation criteria were proposed. The three types of the sections of durability cracking (or alkali-silica reaction), bridge connection, and asphalt overlay were selected as the sections of the field survey. The compressive strength, void structure, and chloride penetration depth were suggested as the items of the laboratory test. CONCLUSIONS : A fundamental level of the guideline was suggested in this study to resolve the problem of old concrete pavement. Appropriate guidelines related to the repair of the old concrete pavement should be provided by performing additional research efforts.

Value of PAX1 Methylation Analysis by MS-HRM in the Triage of Atypical Squamous Cells of Undetermined Significance

  • Li, Shi-Rong;Wang, Zhen-Ming;Wang, Yu-Hui;Wang, Xi-Bo;Zhao, Jian-Qiang;Xue, Hai-Bin;Jiang, Fu-Guo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권14호
    • /
    • pp.5843-5846
    • /
    • 2015
  • Background: Detection of cervical high grade lesions in patients with atypical squamous cells of undetermined significance (ASCUS) is still a challenge. Our study tested the efficacy of the paired boxed gene 1 (PAX1) methylation analysis by methylation-sensitive high-resolution melting (MS-HRM) in the detection of high grade lesions in ASCUS and compared performance with the hybrid capture 2 (HC2) human papillomavirus (HPV) test. Materials and Methods: A total of 463 consecutive ASCUS women from primary screening were selected. Their cervical scrapings were collected and assessed by PAX1 methylation analysis (MS-HRM) and high-risk HPV-DNA test (HC2). All patients with ASCUS were admitted to colposcopy and cervical biopsies. The Chisquare test was used to test the differences of PAX1 methylation or HPV infection between groups. Results: The specificity, sensitivity, and accuracy for detecting CIN2 + lesions were: 95.6%, 82.4%, and 94.6%, respectively, for the PAX1 MS-HRM test; and 59.7%, 64.7%, and 60.0% for the HC2 HPV test. Conclusions: The PAX1 methylation analysis by MS-HRM demonstrated a better performance than the high-risk HPV-DNA test for the detection of high grade lesions (CIN2 +) in ASCUS cases. This approach could screen out the majority of low grade cases of ASCUS, and thus reduce the referral rate to colposcopy.

0.5wt% 탄소강을 이용한 해안 야외부식시험과 염수분무시험, 가속부식시험의 가속계수에 대한 연구 (The Study on the Acceleration Factor of Coastal Outdoor Corrosion test, Salt Spray Test and Accelerated Corrosion Test using 0.5wt% carbon steel)

  • 조의열;권기봉;조대형;김종렬
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.209-214
    • /
    • 2013
  • In the industry, accelerated corrosion test is used for the life time prediction. When anti-corrosion test proceeds in real environments, it is difficult that we predict and evaluate the corrosion life time because of the long test time such as 10 years or more time. Accelerated corrosion test and Salt spray test are able to test corrosion life time of products in the laboratory instead of outdoor corrosion test. Experimental procedure is selected for the corrosion standard specimen, exposure of the specimens, measurements of the mass loss and evaluating the mass loss data. As a result, the acceleration factor of the accelerated corrosion test to the outdoor corrosion test is 414.8. Therefore we can predict the corrosion life time of carbon steel during a short time period.

Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

  • Liu, Xiao;Liao, Ruijin;Lv, Yandong;Liu, Jiefeng;Gao, Jun;Hao, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1107-1113
    • /
    • 2015
  • Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the “time temperature shift technique” was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.

소 브루셀라병 표준시험관응집반응법 진단효율 평가 (Evaluation on diagnostic efficiency of the standard tube agglutination test for bovine brucellosis)

  • 성소라;김지연;허문;이기찬;구정희;강성일;이향근;김숙미;정석찬
    • 한국동물위생학회지
    • /
    • 제35권4호
    • /
    • pp.269-273
    • /
    • 2012
  • A confirmatory serological test, the standard tube agglutination test (STAT) is evaluated for the diagnostic efficiency in brucellosis Korea. A total of 345 bovine samples were collected from regional veterinary branch under national brucellosis monitoring program from January 2010 to June 2012 in Korea. These samples were diagnosed as suspected serum and brucellosis positive by the Rose Bengal test (RBT) and the STAT, respectively. The STAT was compared and evaluated with three serological test such as the indirect-enzyme linked immunosorbent assay (I-ELISA), competitive-enzyme linked immunosorbent assay (C-ELISA) and fluorescence polarisation assay (FPA) prescribed for international trade by OIE. Among the 345 bovine serum samples, 302 (87.5%) were diagnosed as positive in the STAT, while 215 (62.3%), 223 (64.6%) and 194 (56.2%) serum samples were diagnosed as positive for brucellosis in the I-ELISA, C-ELISA and FPA, respectively. The STAT showed quite high positive results as compared with three prescribed tests of OIE. FPA, I-ELISA and C-ELISA have shown 60.6%, 64.9% and 67.2% correlation, respectively as compared to the STAT. However correlations of three prescribed tests ranged high 84.1~97.7%. Especially, correlation between I-ELISA and C-ELISA is quite high, 97.7%. These results suggest that the STAT has shown many false-positive reactions. Therefore, additional serological test, such as ELISAs and FPA, would be necessary to adopt as a confirmatory test in the national surveillance program of bovine brucellosis in Korea.

Spacecraft vibration testing: Benefits and potential issues

  • Kolaini, Ali R.;Tsuha, Walter;Fernandez, Juan P.
    • Advances in aircraft and spacecraft science
    • /
    • 제5권2호
    • /
    • pp.165-175
    • /
    • 2018
  • Jet Propulsion Laboratory has traditionally performed system level vibration testing of flight spacecraft. There have been many discussions in the aerospace community for more than a decade about spacecraft vibration testing benefits or lack thereof. The benefits and potential issues of fully assembled flight spacecraft vibration testing are discussed herein. The following specific topics are discussed: spacecraft screening test to uncover workmanship problems for launch dynamics environments, force- and moment-limited vibration testing, potential issues with structural frequency identification using base shake test data, and failures related to vibration shaker testing and ways to prevent them.