• 제목/요약/키워드: Laboratory scanner

검색결과 114건 처리시간 0.028초

Comparison of Reproducibility of Linear Measurements on Digital Models among Intraoral Scanners, Desktop Scanners, and Cone-beam Computed Tomography

  • Jo, Deuk-Won;Kim, Mijoo;Kim, Reuben H.;Yi, Yang-Jin;Lee, Nam-Ki;Yun, Pil-Young
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2022
  • Purpose: Intraoral scanners, desktop scanners, and cone-beam computed tomography (CBCT) are being used in a complementary way for diagnosis and treatment planning. Limited patient-based results are available about dimensional reproducibility among different three-dimensional imaging systems. This study aimed to evaluate dimensional reproducibility among patient-derived digital models created from an intraoral scanner, desktop scanner, and two CBCT systems. Materials and Methods: Twenty-nine arches from sixteen patients who were candidates for implant treatments were enrolled. Different types of CBCT systems (KCT and VCT) were used before and after the surgery. Polyvinylsiloxane impressions were taken on the enrolled arches after the healing period. Gypsum casts were fabricated and scanned with an intraoral scanner (CIOS) and desktop scanner (MDS). Four test groups of digital models, each from CIOS, MDS, KCT, and VCT, respectively, were compared to the reference gypsum cast group. For comparison of linear measurements, intercanine and intermolar widths and left and right canine to molar lengths were measured on individual gypsum cast and digital models. All measurements were triplicated, and the averages were used for statistics. Bland-Altman plots were drawn to assess the degree of agreement between each test group with the reference gypsum cast group. A linear mixed model was used to analyze the fixed effect of the test groups compared to the reference group (α=0.05). Result: The Bland-Altman plots showed that the bias of each test group was -0.07 mm for CIOS, -0.07 mm for MDS, -0.21 mm for VCT, and -0.25 mm for KCT. The linear mixed model did not show significant differences between the test and reference groups (P>0.05). Conclusion: The linear distances measured on the digital models created from CIOS, MDS, and two CBCT systems showed slightly larger than the references but clinically acceptable reproducibility for diagnosis and treatment planning.

초점거리 편의가 지상 정확도에 미치는 영향 비교 연구 - 세가지 라인 스캐너를 대상으로 - (Comparative Analysis of Focal Length Bias for Three Different Line Scanners)

  • 김창재
    • 한국측량학회지
    • /
    • 제32권4_1호
    • /
    • pp.363-371
    • /
    • 2014
  • 다수의광학위성센서들이선형 배열 형태에 기반을두고설계되었다. 널리 알려진 광학위성센서의 종류는 다음과 같이 경로 평행 방향 1열스캐너(along-track line scanner), 경로 직각 방향 1열 스캐너(across-track linescanner), 3열 스캐너(three- line scanner)로 구분할 수 있다. 이들 센서들을 이용하여 위성 및 항공기에서 지상지물의 정확한 위치정보를 획득하려고 할 때 센서의 외부 표정요소와 내부 표정요소는 매우 중요한 요소들이다. 이들 센서들의 영상생성기하구조는 태양에 의한열영향, 진동, 바람등의 다양한 물리적 현상들에 의하여 시시각각 변동될 가능성이 있기에 내부표정요소의 편의가 지상에 미치는 영향을 분석하는 것은 매우 중요하다. 실제적인 비행경로와 자세정보를 바탕으로 생성된 시뮬레이션 자료를 이용하여 본 연구에서는 각 센서의 초점거리에 편의량을 점진적으로 추가하면서 실험과 분석을 수행하였으며, 또한 비행고도를 고고도와 저고도의 두가지 경우로 비교하였다.실험결과, 경로평행방향 1열 스캐너의 경우에 초점거리편의량의 증가가 지상스캔라인방향(Y 방향)의 오차를 유발하였으며, 경로 직각 방향 1열 스캐너의 경우 스캔라인방향과 수직방향으로 오차가 증가하였고, 3열 스캐너의 경우에는 수직방향으로만 오차가 증가하였다. 이들 실험결과는 향후 새로운 센서개발과 센서캘리브레이션 정확도에 가이드라인을 제공할 수 있다고 본다.

Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration

  • Jiansong, Mei;Liya, Ma;Jiarui, Chao;Fei, Liu;Jiefei, Shen
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권6호
    • /
    • pp.369-378
    • /
    • 2022
  • PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations.

RGB 값을 고려한 레이저 스캐너 반사율과 풍화도의 관계에 대한 연구 (The Relationship between Weathering Degree and Reflectance of Laser Scanner Considering RGB Value)

  • 유완규;김진환;김태호
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.7182-7188
    • /
    • 2015
  • 최근 수기에 의한 맵핑 방식을 탈피하고자 고해상도 카메라, 레이저스캐너 등의 장비를 이용한 디지털 맵핑에 대한 관심이 높아지고 있으며 관련 연구도 보고된바 있다. 본 연구에서는 고해상도 화상기술이 연동된 레이저스캐너를 활용하여 굴진면의 공학적 특징 중 하나인 풍화도를 정량적으로 분석 및 산출하고자 실내 및 현장시험을 수행하였다. 레이저스캐너의 반사율(reflectance)값과 풍화도의 상관관계를 분석하고자 현장테스트를 통해 반사율에 영향을 미치는 인자를 파악하였다. 또한 반사율에 영향을 미치는 주요 인자 중 하나인 색상값(RGB value)에 대한 영향을 최소화하고자 실내테스트를 통해 보정식을 제안하였다. 본 연구에서 제안된 보정식은 실제 현장에서 취득한 스캐닝 데이터를 이용하여 보정 전과 후의 결과를 비교하여 검증하였다. 검증결과 보정 반사율 값을 통해 산정된 풍화도 index는 현장에서 관찰된 우세 풍화도 등급 및 풍화도 비율 등과 매우 유사한 결과를 보이는 것으로 확인되었다.

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.

국내산 구강스캐너(eZIS)를 사용한 3D프린트 모형의 정확도 검증 실험 (Accuracy Verification of 3D printing model by Using Domestic Oral Scanner(eZIS))

  • 변태희;남민경;김정호;김부섭
    • 대한치과기공학회지
    • /
    • 제40권3호
    • /
    • pp.115-123
    • /
    • 2018
  • Purpose: The purpose of this study was establishing process of manufacturing dental prosthesis by using eZIS system(DDS Inc.,Korea). Methods: To evaluate accuracy verification, the test was practiced two ways. First, Comparison of 3D printing models and stone models was practiced by using 3D superimposing software. #36 prepared master model was scanned by eZIS system and three 'Veltz3D' 3D printing models and three 'Bio3D' 3D printing models were manufactured. three stone models were manufactured by conventional impression technique. Second, Fitness test was practiced. the 3D printing models and the stone models was compared by manufacturing same resin crown. #36 prepared master model was scanned 9 times and manufactured (milled) 9 resin crowns by eZIS system. These crowns were cemented three 'Veltz3D' 3D printing models, three 'Bio3D' 3D printing models and three stone models. These crowns were sliced mesiodistal axis and gaps were measured by digital microscope. Results: The average accuracy of Bio3D models were 65.75%. Veltz3D(Hebsiba) models were 60.11% Stone models were 41.00%. Conclusion : This study results showed 3D printing model is similar with stone model. So it was under clinical allow, didn't affect final dental prothesis. There were no significant differences in the appearance of the three types of milling crowns.

교합면의 교모형태에 따른 치과용 모형 스캐너의 정확도 평가 (Accuracy evaluation of dental model scanner according to occlusal attrition type)

  • 김동연;김지환;이범일;이주희;김원수;박진영
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.313-320
    • /
    • 2020
  • Purpose: The purpose of this study is to compare and analyze the accuracy of single crowns based on the type of occlusal surface. Methods: A single crown wax pattern was fabricated in three types of occlusal surface. The prepared wax pattern was replicated with silicone, and stone was injected to create a stone model. The prepared specimens were scanned using a model scanner. Scans were classified into three groups, and each scan was performed six times to analyze the trueness and precision of a single crown. In addition, only the occlusal surface area was analyzed for trueness and precision. Data were analyzed using the Kruskal-Wallis H test, a nonparametric test (α=0.05). Results: With regard to the trueness value of the occlusal scan area, the no occlusal tooth attrition (NA) group showed the largest error of 3.5 ㎛, and the complete occlusal tooth attrition (CA) group showed the lowest value of 3.1 ㎛. The NA group had the greatest precision, and the medium occlusal tooth attrition (MA) group and CA group showed a low precision value of 3.2 ㎛; the difference between the groups was statistically significant (α=0.05). In the color difference map, the CA group showed a lower error than the NA group. Conclusion: The occlusal surface with severe attrition had excellent accuracy, but the accuracy of the group without attrition was low. There were significant differences between groups, but clinically acceptable values were shown.

5축 밀링으로 가공한 PMMA 3본 브릿지의 내면 적합도 평가 (Evaluation of internal adaptation of PMMA 3-unit bridge manufactured by 5-axis milling machine)

  • 김총명;김재홍;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제38권2호
    • /
    • pp.63-68
    • /
    • 2016
  • Purpose: The purpose of this study was to assess the internal fitness of the PMMA 3-unit bridge that was fabricated with 5-axis milling machine and to verify the clinically allowable values. Methods: For fabrication of the crown bridge in this study, 25-27 abutment teeth were used. The prepare abutment teeth were scanned with a scanner and 3-unit bridge was designed by using design software. Upon the completion of the design, the 3-unit bridge was fabricated by using a PMMA block with 5-axis milling machine. The internal surface of the fabricated 3-unit bridge was scanned by using a scanner and the difference between the 3-unit bridge and the abutment teeth was assessed by merging them together. Results: $RMS{\pm}SD$ values for PRE group, MOL group, and BRI group were $51.2{\pm}18.2$, $44.8{\pm}10.0$, and $52.1{\pm}8.3{\mu}m$, respectively. The mean of the PRE group was bigger than that of the MOL and BRI group; however, statistically significant difference was not found (p>0.05). Conclusion: The PMMA 3-unit bridge that was fabricated with 5-axis milling machine presented stable internal values for each crown and overall internal values were within the range of clinically allowable values.

구강인기법과 왁스블록의 종류에 따른 금속 코핑의 변연적합도 비교 (Comparison of marginal fit of metal copings according to wax blocks and oral scanning methods)

  • 정인성;김원영;전병욱
    • 대한치과기공학회지
    • /
    • 제42권3호
    • /
    • pp.234-239
    • /
    • 2020
  • Purpose: We investigated the marginal fit between abutment and metal copings according to impression technique, wax block types, and metal types. Methods: We selected the traditional impression method of using rubber impression materials and the digital impression method of using oral scanners, three types of wax blocks, and two types of metal, both of which were domestically and commercially available, were selected to produce metal copings, and the marginal fit was determined through the use of silicon replication. Results: The measurements of axial wall fit revealed that the IYV specimens had the best fit, with a mean gap of 24.11±5.95 ㎛, followed by CEV, CHV, CSS, CSV, CES, CHS, and IYS specimens (mean: 33.44±8.41 ㎛). The differences were not statistically significant. The marginal gap measurements showed that the CEV specimen had the smallest gap, 17.25±4.13 ㎛, followed by the CSV, CHV, CSS, CES, CHS, IYV, and IYS specimen (mean: 43.47±15.63 ㎛). The differences were statistically significant. Conclusion: The axial wall fit of the metal coping (VeraBond2V; Aalba Dent, Inc., Fairfield, CA, USA) produced by the lost wax technique with the traditional impression method was excellent. The marginal fit of the metal coping (VeraBond 2V) produced by wax milling with the use of an oral scanner was also excellent. The marginal fit of the metal coping was within the clinically acceptable limits in all groups.

Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scans

  • Kontis, Panagiotis;Guth, Jan-Frederik;Schubert, Oliver;Keul, Christine
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권5호
    • /
    • pp.316-326
    • /
    • 2021
  • PURPOSE. Purpose of this in vitro study was to determine the accuracy of different intraoral scans versus laboratory scans of impressions and casts for the digitization of an edentulous maxilla. MATERIALS AND METHODS. A PEEK model of an edentulous maxilla, featuring four hemispheres on the alveolar ridges in region 13, 17, 23 and 27, was industrially digitized to obtain a reference dataset (REF). Intraoral scans using Cerec Primescan AC (PRI) and Cerec AC Omnicam (OMN), as well as conventional impressions (scannable polyvinyl siloxane) were carried out (n = 25). Conventional impressions (E5I) and referring plaster casts were scanned with the inEOS X5 (E5M). All datasets were exported in STL and analyzed (Geomagic Qualify). Linear and angular differences were evaluated by virtually constructed measurement points in the centers of the hemispheres (P13, P17, P23, P27) and lines between the points (P17-P13, P17-P23, P17-P27). Kolmogorov-Smirnov test and Shapiro-Wilk test were performed to test for normal distribution, Kruskal-Wallis-H test, and Mann-Whitney-U test to detect significant differences in trueness, followed by 2-sample Kolmogorov-Smirnov test to detect significant differences in precision (P < .008). RESULTS. Group PRI showed the highest trueness in linear and angular parameters (P < .001), while group E5I showed the highest precision (P < .001). CONCLUSION. Intraoral scan data obtained using Primescan showed the highest trueness while the indirect digitization of impressions showed the highest precision. To enhance the workflow, indirect digitization of the impression itself appears to be a reasonable technique, as it combines fast access to the digital workflow with the possibility of functional impression of mucosal areas.