• Title/Summary/Keyword: Laboratory experiments

Search Result 2,739, Processing Time 0.029 seconds

Effects of Inoculum Density, Plant Age and Temperature on the Incidence of Crown Rot of Papper Caused by Phytophthora capsici (전염원(傳染源)의 농도(濃度), 고추의 모령(苗齡) 및 온도(溫度)가 고추역병(疫病) 발생(發生)에 미치는 영향(影響))

  • Kim, G.S.;Park, C.S.;Choi, J.S.
    • Korean journal of applied entomology
    • /
    • v.24 no.3 s.64
    • /
    • pp.117-121
    • /
    • 1985
  • Through the laboratory and vinyl house experiments, the effects of inoculum density, plant age and temperature on the incidence of Phytophthora crown rot of pepper (Capsicum annum L.) were investigated. The propagule survival was greater in the natural soil than in autoclaved soil within first 2 weeks when the sporangial suspension of the pathogenic fungus was incorporated into soil, thereafter the survivability reduced rapidly. The propagule was not detectable in 35 days by means of Papavizas selective medium neither in natural nor in autoclaved soil. At least 5 sporangia per gram soil were required to induce crown rot for 30 days old pepper seedlings. Further increase in inoculum concentration above this threshold level resulted in higher disease incidence and shorter incubation period. When the same amount of inoculum was infested, higher disease incidence was observed for younger plants until 3 weeks after inoculation. On the other hand after 4 weeks this tendency was not extended any more. Younger plants were recognized as having shorter incubation period upon infection, however, the days from first symptom appearance to complete death were not significantly different among differently aged seedlings. Exposure of inoculated pepper seedlings to $25^{\circ}C$ resulted in highest infection rates and followed by those to $30^{\circ}C\;and\;20^{\circ}C$ but no disease was found at $15^{\circ}C\;and\;35^{\circ}C$ for 10 days. When the plants previously incubated at different temperature for 10 days were moved to $25^{\circ}C$ room temperature, prior exposure to $20^{\circ}C\;and\;30^{\circ}C$ brought continuous disease development. Even those plants preincubated at $15^{\circ}C$ were diseased up to 50%. But the prior exposure to $35^{\circ}C$ induced no symptom developed, indicating no seedlings infected at all.

  • PDF

The Effect of the Anthracnose Resistant Chili Pepper (PepEST gene) on the Non-target Insects, Green Peach Aphids (Myzus persicae Sulzer, Homoptera) (유전자 변형 탄저병 저항성 고추(PepEST gene)가 비표적 곤충인 복숭아혹진딧물(Myzus persicae Sulzer)에 미치는 영향)

  • Park, Ji-Eun;Yi, Hoon-Bok;Kim, Chang-Gi;Jeong, Soon-Chun;Yoon, Won-Kee;Park, Kee-Woong;Lee, Bum-Kyu;Kim, Hwan-Mook
    • Korean journal of applied entomology
    • /
    • v.46 no.3
    • /
    • pp.343-348
    • /
    • 2007
  • To assess the environmental risks of transgenic chili pepper with PepEST gene on non-target organisms before it exposes to the agro-ecosystem environments, we conducted the three sets of green peach aphids (Myzus persicas S.) life table experiment under laboratory conditions (Temp. $25^{\circ}C$, R.H. 50-70%, Photoperiod L16 : D8) in series during 2005-2006. We measured the net reproductive rate ($R_0)^*$, the intrinsic rate of increase ($r_m$), the mean generation time ($T_c$), $fecundity^*$, life span, and reproduction period between non-transgenic chili peppers and transgenic chili peppers, respectively. The life span of green peach aphids from three sets was 31, 27, 25 days, and the period of life span was similar to the general average length of green peach aphids, 25-29 days. Although the first reproduction of transgenic pepper was similar to the non transgenic pepper (P>0.05), the fecundity and the net reproductive rate ($R_o$) by using Jackknife method of transgenic pepper were lower than those of non transgenic pepper (P<0.05). Conclusively, we observed the adverse effect from our results but we should execute further experiments to confirm the results at the fields with the similar way.

A Study on Bio-Monitoring Systems using Shell Valve Movements of Pacific Oysters (Crassostrea gigas) in response to Abnormal High Water Temperature (이상 고수온에 반응하는 이매패류 참굴(Crassostrea gigas)의 패각운동을 활용한 생물모니터링시스템 연구)

  • Moon, Suyeon;Kim, Dae Hyun;Yoon, Yang Ho;Oh, Seok Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.1
    • /
    • pp.91-97
    • /
    • 2017
  • This study contains research on a bio-monitoring system (BMS) capable of detecting abnormal high water temperatures, the shell valve movements (SVMs) of Pacific oysters (Crassostrea gigas), which were measured at four different temperature (5, 10, 20 and $30^{\circ}C$) under laboratory conditions. All the Pacific oysters were kept under fasting conditions for 3 days to prevent the influence of food and excretions before the onset of the experiments. SVMs did not detect at $5^{\circ}C$. However, SVMs increased with an increase in temperature (at $10^{\circ}C$ : $6.31{\pm}2.18times/hr$ and at $20^{\circ}C$: $22.0{\pm}10.0times/hr$). At $30^{\circ}C$, SVMs were divided into two groups: those with no SVMs as at $5^{\circ}C$ and those with SVMs similar to conditions at $20^{\circ}C$($23.9{\pm}9.35times/hr$). This indicates oyster shells maintain a closed condition due to a decrease in metabolism at $30^{\circ}C$, although some Pacific oysters had active SVMs due to an increase in metabolism. If a BMS using the SVM status of Pacific oysters was installed to monitor abnormal high water around oyster farms, early warning levels and serious alerts might be made available more rapidly for SVMs of more than ca. 30 times/hr and closing conditions in a matter of hours, respectively. Therefore, a BMS using the SVMs of Pacific oysters might be an effective early warning system for abnormal high water temperatures.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Recycling of Acidic Etching Waste Solution Containing Heavy Metals by Nanofiltration (I): Evaluation of Acid Stability of Commercial Nanofiltration Membranes (나노여과에 의한 중금속 함유 산성 폐에칭액의 재생(I): 상용 나노여과 막의 산 안정성 평가)

  • Youm, Kyung-Ho;Shin, Hwa-Sup;Jin, Cheon-Deok
    • Membrane Journal
    • /
    • v.19 no.4
    • /
    • pp.317-323
    • /
    • 2009
  • In this study the nanofiltration (NF) membrane treatment of a nitric acid waste solutions containing $Pb^{+2}$ heavy metal ion discharging from the etching processes of an electronics and semiconductors industry has been studied for the purpose of recycling of nitric acid etching solutions. Three kinds of NF membranes (General Electric Co. Duraslick NF-4040 membrane, Dow Co. Filmtec LP-4040 membrane and Koch Co. SelRO MPS-34 4040 membrane) were tested for their separation efficiency (total rejection) of $Pb^{+2}$ ion and membrane stability in nitric acid solution. NF experiments were carried out with a dead-end membrane filtration laboratory system. The membrane permeate flux was increased with the increasing storage time in nitric acid solution and lowering pH of acid solution because of the enhancing of NF membrane damage by nitric acid. The membrane stability in nitric acid solution was more superior in the order of Filmtec LP-4040 < Duraslick NF-4040 < SelRO MPS-34 4040 membrane. The total rejection of Pb+2 ion was decreased with the increasing storage time in nitric acid solution and lowering the pH of acid solution. The total rejection of $Pb^{+2}$ ion after 4 months NF treatment was decreased from 95% initial value to 20% in the case of Duraslick NF-4040 membrane, from 85% initial value to 65% in the case of SelRO MPS-34 4040 membrane and from 90% initial value to 10% in the case of Filmtec LP-4040 membrane. These results showed that SelRO MPS-34 4040 NF membrane was more suitable for the treatment of an acidic etching waste solutions containing heavy metal ions.

Evaluation of Nutrients Removal using Pyrolyzed Oyster Shells (소성온도에 따른 굴 패각의 영양염 제거 성능 평가)

  • Jeong, Ilwon;Woo, Hee-eun;Lee, In-Cheol;Kim, Jinsoo;Kim, Kyunghoi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.906-913
    • /
    • 2019
  • To evaluate the removal performance of PO4-P and NH3-N, laboratory experiments were conducted by filling a container with oyster shells, pyrolyzed at 100℃ (POS100), 600℃ (POS600) and 800℃ (POS800), and passing artificial wastewaters through the container. The pH in the ef luent was found to increase due to CaO eluted from oyster shell. Removal amounts of PO4-P of ~23.1 mg/kg, 16.1 mg/kg, and 15.9 mg/kg were obtained when POS100, POS600, and POS800, respectively, were used; therefore, the highest PO4-P removal amount was obtained when POS100 was used. It is considered that Ca and dolomite in the oyster shells adsorbed and precipitated PO4-P. Removal amounts of NH3-N were of ~3.56 mg/kg, 5.72 mg/kg, and 3.97 mg/kg were obtained when POS100, POS600, and POS800, respectively, were used The low removal rate for NH3-N is probably due to unstable nitrification, use of sealed containers, and the effect of NH3-N being converted to NH4+ upon increasing pH. Based on these results, pyrolyzed oyster shell is expected to promote changes in PO4-P and NH3-N concentrations through chemical reactions. These results can also be used for basic research in the development of wastewater treatment.

Characteristics of Shear Strength and Elastic Waves in Artificially Frozen Specimens using Triaxial Compression Tests (삼축압축실험을 이용한 인공동결시료의 강도평가 및 탄성파 특성변화)

  • Kim, JongChan;Lee, Jong-Sub;Hong, Seung-Seo;Lee, Changho
    • The Journal of Engineering Geology
    • /
    • v.24 no.1
    • /
    • pp.111-122
    • /
    • 2014
  • For accurate laboratory evaluations of soil deposits, it is essential that the samples are undisturbed. An artificial ground-freezing system is the one of the most effective methods for obtaining undisturbed samples from sand deposits. The objective of this study is to estimate the shear strengths and the characteristics of elastic waves of frozen-thawed and unfrozen specimens through the undrained triaxial compression test. For the experiments, Jumunjin standard sands are used to prepare frozen and unfrozen specimens with similar relative densities (60% and 80%). The water pluviation method is used to simulate the fully saturated condition under the groundwater table. When thawing the frozen specimens, the temperature is measured every minute. After the specimens are completely thawed, undrained triaxial compression tests are conducted using the same procedures as for the unfrozen specimens. During the triaxial tests (saturation, consolidation, and shear phase), compressional and shear waves are measured. The results show that the freeze-thaw process has minor effects on the peak deviatoric stress and shear strength values, and that the process does not affect the internal friction angle. The compressional wave velocity increases with increasing B-value to 1800 m/s in the saturation phase, but tends to remain constant in the process of consolidation and shearing. The shear wave velocity decreases with increasing B-value in the process of saturation, but changes velocity in accordance with the change in effective stress in the processes of consolidation and shearing. The compressional wave velocity has similar values regardless of the freeze-thaw process, but values of shear wave velocity are slighly lower in frozen-thawed specimens than in unfrozen specimens. This study is a preliminary experiment for estimating the shear strength and characteristics of elastic wave velocity in undisturbed frozen specimens that have been obtained using the artificial ground-freezing method.

Effects of Concentration and Size of Porous Calcium Silicate (PCS) in Broiler Feeds on Performances, Fly Generation and Malodorous Gas Emission (Porous Calcium Silicate(PCS)의 급여수준 및 PCS 입자 크기가 육계의 성장, 파리 및 악취 발생에 미치는 영향)

  • Jeon, B.S.;Song, J.I.;Jeon, J.H.;Kwag, J.H.;Kang, H.S.;Choi, H.C.;Kim, T.I.;Lee, E.S.;Nahm, K.H.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.2
    • /
    • pp.115-130
    • /
    • 2009
  • Three experiments on the addition of Porous Calcium Silicate (PCS) to broiler feed were conducted at different time periods in the same house. Each treatment had 4 replicates with 12 chicks in each treatment. Weight gain and feed intake were higher ($P{\le}0.05$) in the control groups. Feed conversions' were better ($P{\le}0.05$) in the PCS group, 3.0% PCS and 20 mesh size of PCS than the control group from 21 to 49 days, and for the overall period. $NH_3$ and $H_2S$. gas production were decreased ($P{\le}0.05$) when zeolite was added in broiler feeds. 1.5% or 3.0% PCS in broiler feed was better ($P{\le}0.05$) than the 4% PCS. More than 90 mesh size PCS was better ($P{\le}0.05$) in controlling $CO_2$ production in the 5th period than the 20 or 50 mesh size or control groups. The control and PCS groups produced more flies ($P{\le}0.05$) than zeolite group during the 2nd and 3rd weeks. The 3.0% or 4.5% PCS or 50 or 90 mesh size of PCS in broiler feed produced more flies than the 20 mesh size or control groups although 50 or 90 mesh size of PCS during 5th week tended to have lower fly production than the 20 mesh size of PCS and control group.

  • PDF

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.