• Title/Summary/Keyword: Laboratory attachment

Search Result 113, Processing Time 0.03 seconds

"Computer Programming IV" as Capstone Design and Laboratory Attachment

  • Yokoyama, Shoichi
    • Journal of Engineering Education Research
    • /
    • v.15 no.5
    • /
    • pp.31-35
    • /
    • 2012
  • A new obligatory subject, Computer Programming IV, is organized in the Department of Informatics, Faculty of Engineering, Yamagata University. The purposes of the subject are as follows: (1) Attachment to each laboratory for bachelor thesis was usually at the initial stage of the student's fourth academic year. This subject actually moves up the attachment because students are tentatively attached to a laboratory for this subject. The interval to complete their bachelor thesis is extended by half a year. (2) In each laboratory, students cooperate with each other to complete their project. The project becomes capstone design which JABEE (Japan Accreditation Board for Engineering Education) is recently emphasizing. We not only explain the introduction of this subject, but also report some case studies.

Monocyte Attachment and Migration through Collagen IV in Diabetes Mellitus

  • Kostidou, Elena;Koliakos, George;Paletas, Konstantinos;Kaloyianni, Martha
    • Molecules and Cells
    • /
    • v.25 no.3
    • /
    • pp.452-456
    • /
    • 2008
  • The interactions between monocytes and extracellular matrix proteins have been implicated in atherosclerosis pathophysiology. In the present study we evaluated monocyte attachment and migration through oxidized and non-oxidized collagen IV. Monocyte attachment was tested on microwells coated with either native or oxidized collagen IV. Monocyte migration through collagen IV was examined on transwells. Monocytes derived from patients with diabetes mellitus showed an increased ability to attach and migrate through collagen IV as compared to those derived from healthy volunteers. Moreover, control monocytes attached to oxidized collagen at a higher degree, while they migrated through oxidized collagen at a lower degree, as compared to the native protein. Our results also showed the involvement of the alpha2 integrin subunit in the above phenomena suggesting a modified interaction between monocytes and collagen IV in diabetes mellitus.

An Ecological Study on Infant-Mother Attachment in a Nonmaternal Care (타인 양육 영아-어머니 애착에 대한 생태학적 연구)

  • 양연숙
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.7
    • /
    • pp.1-14
    • /
    • 2002
  • This study investigated infant, mother/famny, and nonmaternal care characteristics contribution to infant- mother attachment through ecological perspective. Participants were forty 12-to 18-month-o1d infants and their mothers. Infants were observed in the Strange Situation to assess the pattern of infant-mother attachment; the Observational Ratings of the Caregiving Environment was used to assess the caregiving environment. Mothers were interviewed with the questionnaires, and observed in the laboratory "living room". There were significant effects of material sensitivity/responsiveness and good quality child care on secure attachment. Infant, mother/family, and nonmaternal care characteristics were mutually related.

Implantation in Ruminants: Changes in Pre-Implantation, Maternal Recognition of Pregnancy, Control of Attachment and Invasion - Review -

  • Nagaoka, K.;Yamaguchi, H.;Aida, H.;Yoshioka, K.;Takahashi, M.;Christenson, R.K.;Imakawa, K.;Sakai, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.6
    • /
    • pp.845-855
    • /
    • 2000
  • As high as 50% of pregnancies are known to fail and the majority of such losses occur during the peri-implantation period. For the establishment of pregnancy in mammalian species, therefore, implantation of the conceptus to the maternal endometrium must be completed successfully. Physiological events associated with implantation differ among mammals. In ruminant ungulates, an elongation of the trophohlast in early conceptus development is required before the attachment of the conceptus to the uterine endometrium. Moreover, implantation sites are restricted to each uterine caruncula where tissue remodeling, feto-maternal cell fusion and placentation take place in a coordinated manner. These unique events occur under strict conditions and are regulated by numerous factors from the uterine endometrium and trophoblast in a spatial manner. Interferon-tau (IFN-${\tau}$), a conceptus-derived anti-Iuteolytic factor, which rescues corpus luteum from its regression in ruminants, is particularly apt to play an important role as a local regulator in coordination with other factors, such as TGF-${\beta}$, Cox-2 and MMPs at the attachment and placentation sites.

Quantification of Bacterial Attachment-related Parameters in Porous Media

  • Park, Seong-Jik;Lee, Chang-Gu;Kim, Song-Bae
    • Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.141-146
    • /
    • 2008
  • Transport of Escherichia coli ATCC 11105 through porous media was investigated in this study using two sets of column experiments to quantify the attachment-related parameters (sticking efficiency, attachment rate coefficient and filter factor). The first set of experiments was performed in quartz sand under different ionic strength conditions (1, 20, 100, 200 mM) while the second experiments were carried out in quartz sand mixed with metal oxyhydroxide-coated sand (0, 5, 10, 25%). The breakthrough curves of bacteria were obtained by monitoring effluent, and then bacterial mass recovery and attachment-related parameters were quantified from these curves. The first experiments showed that the mass recoveries were in the range of 13.3 to 64.7%, decreasing with increasing ionic strength. In the second experiments, the mass recoveries were in the range of 15.0 to 43.4%, decreasing with increasing coated sand content. The analysis indicated that the sticking efficiency, attachment rate coefficient and filter factor increased with increasing ionic strength and coated sand content. The value of filter factor in the first experiments ranged from 1.45 e-2 to 6.72 e-2 1/cm while in the second experiments it ranged from 2.78 e-2 to 6.32 e-2 1/cm. Our filter factor values are one order of magnitude lower than those from other studies. This discrepancy can be attributed to the size of sand used in the experiment. The analysis demonstrated that the travel distance of bacteria estimated using the filter factor can be varied greatly depending on the solution chemistry and charge heterogeneity of porous media.

Optimized study of an in vitro 3D culture of preantral follicles in mice

  • Hehe Ren;Yingxin Zhang;Yanping Zhang;Yikai Qiu;Qing Chang;Xiaoli Yu;Xiuying Pei
    • Journal of Veterinary Science
    • /
    • v.24 no.1
    • /
    • pp.4.1-4.16
    • /
    • 2023
  • Background: In vitro culture of preantral follicles is a promising technology for fertility preservation. Objectives: This study aims to investigate an optimized three-dimensional (3D) fetal bovine serum (FBS)-free preantral follicle culture system having a simple and easy operation. Methods: The isolated follicles from mouse ovaries were randomly divided in an ultra-low attachment 96-well plates supplement with FBS or bovine serum albumin (BSA) culture or encapsulated with an alginate supplement with FBS or BSA culture. Meanwhile, estradiol (E2) concentration was assessed through enzyme-linked immunosorbent assay of culture supernatants. The diameter of follicular growth was measured, and the lumen of the follicle was photographed. Spindle microtubules of oocytes were detected via immunofluorescence. The ability of oocytes to fertilize was assessed using in vitro fertilization. Results: The diameters were larger for the growing secondary follicles cultured in ultra-low attachment 96-well plates than in the alginate gel on days 6, 8, and 10 (p < 0.05). Meanwhile, the E2 concentration in the BSA-supplemented medium was significantly higher in the alginate gel than in the other three groups on days 6 and 8 (p < 0.05), and the oocytes in the FBS-free system could complete meiosis and fertilization in vitro. Conclusions: The present study furnishes insights into the mature oocytes obtained from the 3D culture of the preantral follicle by using ultra-low attachment 96-well plate with an FBS-free system in vitro and supports the clinical practices to achieve competent, mature oocytes for in vitro fertilization.

Attachment of Bacillus subtilis to Al-Fe Bimetallic Oxide-coated Sand : Effect of Oxyanions (알루미늄.철 산화물 동시피복모래에서 Bacillus subtilis의 부착: 산화음이온의 영향)

  • Park, Seong-Jik;Lee, Chang-Gu;Han, Yong-Un;Park, Jeong-Ann;Kim, Song-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.515-520
    • /
    • 2009
  • This study investigated the influence of oxyanions (nitrate, carbonate, phosphate) on the attachment of bacteria (Bacillus subtilis) to Al-Fe bimetallic oxide-coated sand using column experiments. Results showed that bacterial attachment to the coated sand was independent of nitrate concentration. Bacterial mass recovery remained constant (10.9${\pm}$0.2%) with varying nitrate concentrations (0.1, 1, 10 mM). In case of carbonate, mass recovery increased from 25.6% to 39.0% with increasing carbonate concentration from 0.1 mM to 1 mM, and mass recovery also increased from 50.9% to 78.9% at the same concentration condition in case of phosphate. This phenomenon could be attributed to the hindrance effect of carbonate and phosphate to bacterial attachment to the coated sand. Meanwhile, with increasing carbonate/phosphate concentration from 1 mM to 10 mM, mass recovery decreased from 39.0% to 23.8% and from 78.9% to 52.6%, respectively. This phenomenon could be ascribed to the enhancement effect of free carbonate/phosphate ions present in solution phase due to increasing carbonate/phosphate concentration, which increase ionic strength and thus enhance bacterial attachment to the coated sand. In our experimental conditions, the effect of phosphate to bacterial attachment to the coated sand was the greatest among phosphate, carbonate, and nitrate.

Detrimental effects of lipopolysaccharide on the attachment and outgrowth of various trophoblastic spheroids on human endometrial epithelial cells

  • Kim, Wontae;Choi, Jungwon;Yoon, Hyejin;Lee, Jaewang;Jun, Jin Hyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.48 no.2
    • /
    • pp.132-141
    • /
    • 2021
  • Objective: Lipopolysaccharide (LPS) from Gram-negative bacteria causes poor uterine receptivity by inducing excessive inflammation at the maternal-fetal interface. This study aimed to investigate the detrimental effects of LPS on the attachment and outgrowth of various types of trophoblastic spheroids on endometrial epithelial cells (ECC-1 cells) in an in vitro model of implantation. Methods: Three types of spheroids with JAr, JEG-3, and JAr mixed JEG-3 (JmJ) cells were used to evaluate the effect of LPS on early implantation events. ECC-1 cells were treated with LPS to mimic endometrial infection, and the expression of inflammatory cytokines and adhesion molecules was analyzed by quantitative real-time polymerase chain reaction and western blotting. The attachment rates and outgrowth areas were evaluated in the various trophoblastic spheroids and ECC-1 cells treated with LPS. Results: LPS treatment significantly increased the mRNA expression of inflammatory cytokines (CXCL1, IL-8, and IL-33) and decreased the protein expression of adhesion molecules (ITGβ3 and ITGβ5) in ECC-1 cells. The attachment rates of JAr and JmJ spheroids on ECC-1 cells significantly decreased after treating the ECC-1 cells with 1 and 10 ㎍/mL LPS. In the outgrowth assay, JAr spheroids did not show any outgrowth areas. However, the outgrowth areas of JEG-3 spheroids were similar regardless of LPS treatment. LPS treatment of JmJ spheroids significantly decreased the outgrowth area after 72 hours of coincubation. Conclusion: An in vitro implantation model using novel JmJ spheroids was established, and the inhibitory effects of LPS on ECC-1 endometrial epithelial cells were confirmed in the early implantation process.

Comparison of Stress of the Abutment Teeth and Denture Base in Distal Extension Removable Partial Dentures Retained Konus Crown, Precision Attachment and RPI Clasp with the Occlusal Load Application (유리단 국소의치의 교합하중 적용시 이중금관, 어태치먼트 및 RPI clasp 유지장치에 따라 지대치와 의치상에 미치는 응력 비교)

  • Jun, In-Sik;Kim, Bu-Sub;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.331-346
    • /
    • 2006
  • Free-end partial dentures, which are supported by teeth surrounded by dental root membranes and elastic mucous membrane tissues, may cause stress to the abutment teeth due to external force imposed on the denture base, increase the mobility of the abutment teeth, and bring about a change in the periodontal tissue. General retainers used in partial dentures are categorized into clasp, attachment, and Konus crown. Stress imposed on the abutment teeth and mobility of the denture base have relations with the lifetime of a crown and abutment teeth, and have direct relations with the chewing ability. Thus, a need arises to make a comparative analysis of stress of the three direct retainers on the abutment teeth and interpret the mobility of the denture base. This study designed three kinds of removable partial dentures (one kind of attachment partial denture, one kind of Konus crown partial denture, and one kind of clasp partial denture), and fabricated Dentiforms of bilateral partial dentures (Kennedy Class I) with lower left 1st premolar and lower right 1st and 2nd premolars being as the abutment teeth. A strain gauge was installed in the mesial and distal surface of the lowerr left 1st premolar (No. 34) of the fabricated dentiform and in the lower part of the denture base, and installed were a clasp partial denture, an attachment partial denture, and a Konus crown partial denture. Then, the vertical static load of 5kgf and 7.5kgf at the occlusion surface of the lower left No. 6 molar was generated for a total of 20 frequencies of load each using a push-full gauge, and thus a change in the output of the strain gauge was measured. With the respective application of Konus crown, attachment and RPI clasp in the free-end partial denture, surveyed was the distribution of stress imposed on the abutment teeth and the denture base according to the location of occlusion force load so as to come up with the following results. 1. Konus crown and attachment partial dentures generated much stress, and more stress on the abutment teeth than RPI clasp dentures did. Attachment dentures tended to further intensify stress on the abutment teeth than Konus crown dentures did. 2. Attachment dentures and Konus dentures imposed less stress on the denture base than RPI clasp dentures did. There was no stress difference between Attachment and Konus crown dentures. 3. Dentures that were designed with the application of retainers using sturdy linkage methods tended to be less mobile.

  • PDF

CLINICAL CONSIDERATION OF INDIRECT BONDING TECHNIQUE (INDIRECT BONDING TECHNIQUE에 대한 고찰)

  • Lee, Kyung Hwan;Kim, Sang Cheol
    • The korean journal of orthodontics
    • /
    • v.19 no.2
    • /
    • pp.155-163
    • /
    • 1989
  • Indirect bonding is done by placing the brackets on a model in the laboratory and using a template or tray to transfer the laboratory positioning to the teeth. The advantages of this technique are 1. decreased chair time 2. less patient discomfort 3. accuracy of a attachment placement 4. good adaptation of attachment to tooth contour 5. occlusal relationship of brackets and opposing teeth can be checked The disadvantages of the technique are 1. complex laboratory procedure 2. sometimes difficult on very short clinical crowns 3. teeth with crowns, large buccal restoration will not bond 4. may not be fitted close, if poor adaptation 5. likely to be disturbed setting Several indirect bonding techniques have proved reliable in clinical practice. However, they differ in the way the brackets are attached temporarily to the model, the type of transfer tray or other mechanism used, the adhesive or sealant employed, whether segmented or full bonding used, and the way the transfer is removed so as not to exert excessive force on a still maturing bond.

  • PDF