• Title/Summary/Keyword: Laboratory

Search Result 42,302, Processing Time 0.069 seconds

Difference in the Quality of Life and Related Factors according to the Employment Status (경제활동 상태에 따른 삶의 질 차이와 관련요인)

  • Gim, Mi-Seon;Han, Ji-Yeon;Kim, Chul-Woung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6080-6088
    • /
    • 2015
  • The purpose of study is to find difference in the quality of life and related factors according to the employment status. Using data from the fifth National Health and Nutrition Survey, economically active population of 20-69 years old 3,429 participants who said to questions of 'economic activity status' were finally used as analysis subjects in Korea. According to economic activity status, individuals were divided by the six different employment status and their quality of life was inspected using the EQ-5D dimensions and index score as well as analyzing the factors affecting the quality of life. As a result, unemployed compared to full-time workers, had significantly higher needs of four dimensions and Unpaid family workers had in the dimensions of Mobility, Self-care and Usual activities and temporary job had in the dimensions of Self-care and Usual activities. After figuring out life quality factors according to employment status, it was found that compared to full-time workers greater age(${\beta}=-0.089$, p<0.001), more stress(${\beta}=-0.143$, p<0.0001), hyperlipidemia(${\beta}=-0.064$, p<0.0001), stroke, arthritis(${\beta}=-0.160$, p<0.0001), respiratory diseases(${\beta}=-0.055$, p<0.001) and chronic health conditions were more influential to low quality of life for temporary job(${\beta}=-0.034$, p<0.05), day workers(${\beta}=-0.078$, p<0.0001) and unemplyed(${\beta}=-0.052$, p<0.01). The study is reported that it is to find difference in the quality of life and related factors according to the employment status and it is considered to provide basis for health evaluation of utilization in the same field of study.

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom (팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가)

  • Lim, Jin-Oh;Kim, Tae-Hyung;Jung, Yang-Hwa;Choi, Won-Chan;Shin, Ji-Hoon;Song, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.21-26
    • /
    • 2003
  • To evaluate the newly designed gastroduodenal coil catheter:in-vitro test. The coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3 mm inner diameter and this coil spring was covered with heat-shrinkable polyethylene tube. To measure the length under fluorocopy, 8 radiopaque marks were attached at 5 cm, 10 cm, 11 cm, 12 cm, 13 cm, 14 cm, 15 cm, 20 cm apart from distal end of the catheter and 6, 2, 1 pores were made at 7 cm, 13 cm, 19 cm apart from the distal end. Radio-opacity and the amount of injected contrast was investigated in formerly used 5 Fr. vessel catheter, which is possible in measuring length, and newly designed coil catheter. Film density was tested for radio-opacity with autodensitometer. For measuring the volume of injected salin, the catheter was located in the acryl box(26 cm, 3 cm, 16 cm) that divided into 4 chambers. After injection 50 cc of contrast with autoinjector, the contrast's quantity in each chamber was measured with and without over the guide wire. Radio-opacity was 0.51 in 5 Fr. vessel catheter, 0.31 in newly made catheter. The amount of injected contrast was measured. In case of 5 Fr. vessel catheter, the amount was 99.5% from the distal part, there was no difference between with and without the guide wire. Otherwise, using a coil catheter, the pacentage the ejected saline was 1.17%, 18.8%, 41.8%, 38.2% from the distal part with the guide wire, 19.5%, 32.6%, 27.7%, 20.3% without the guide wire. Compare with formerly established catheter, this new coil catheter is easy to measure the length thanks to easy confirming under fluoroscopy and excellent in injecting contrast. Therefore, newly designed gastrointestinal catheter seems to be useful in gastrointestinal intervention procedure.

  • PDF

Analysis of Factors Influencing the Integrated Bolus Peak Timing in Contrast-Enhanced Brain Computed Tomographic Angiography (Computed Tomographic Angiography (CTA)의 검사 시 조영제 집적 정점시간에 영향을 미치는 특성 인자를 분석)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Jung, Jae-Yong;Yun, Jung-Soo;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.59-69
    • /
    • 2016
  • The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast-enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was $716.53mGy{\cdot}cm$ and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

Analysis of Groundwater Flow Characterization in Fractured Aquifer System (파쇄대 응회암 대수층의 지하수 유동 특성화 기법)

  • Kim Yong-Je;Kim Tae-Hee;Kim Kue-Young;Hwang Se-Ho;Chae Byung-Gon
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.33-44
    • /
    • 2005
  • On the basis of a stepwise and careful integration of various field and laboratory methods the analysis of groundwater flow characterization was performed with five boreholes (BH-1, -2, -3, -4, -5) on a pilot site of Natural Forest Park in Guemsan-gun, Chungcheongbook-do, Korea. The regional lineaments of NW-SE are primarily developed on the area, which results in the development of many fractures of NW-SE direction around boreholes made in the test site for the study. A series of surface geological survey, core logging, geophysical logging, tomography, tracer tests, and heat-pulse flowmeter logging were carried out to determine fracture characteristics and fracture connectivity between the boreholes. In the result of fracture connectivity analysis BH-1 the injection well has a poor connectivity with BH-2 and BH-3, whereas a good with BH-4 and BH-5. In order to analyse the hydraulic connectivity between BH-1 and BH-5, in particular, a conspicuous groundwater outflux in the depth of 12 m and influx in the depth of 65 m and 70 m, but partly in/outflux occurred in other depths in BH-5 were observed as pumping from BH-1. On the other hand, when pumping from BH-5 the strong outflux in the depths of 17 m and 70 m was occurred. The spatial connectivity between the boreholes was examined in the depth of 15 m, 67 m, and 71 m in BH-1 as well as in the depth of 15 m, 17 m, 22 m, 72 m, and 83 m in BH-5.

Characterization of Low-Temperature Pyrolysis and Separation of Cr, Cu and As Compounds of CCA-treated Wood (CCA (Chromated Copper Arsenate) 처리 목재의 저온 열분해와 CCA 유효 성분분리 특성)

  • Lim, Kie-Pyo;Lee, Jong-Tak;Bum, Jung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.73-80
    • /
    • 2007
  • This study was carried out to separate the heavy toxic metals in eco-building materials by low-temperature pyrolysis, especially arsenic (As) compounds in CCA wood preservative as a solid in char. The pyrolysis was carried out to heat the CCA-treated Hemlock at $280^{\circ}C$, $300^{\circ}C$, $320^{\circ}C$, and $340^{\circ}C$ for 60 mins. Laboratory scale pyrolyzer composed of [preheater$\rightarrow$pyrolyzer$\rightarrow$1st water scrubber$\rightarrow$2nd bubbling flask with 1% $HNO_3$ solution$\rightarrow$vent], and was operated to absorb the volatile metal compound particulates at the primary water scrubber and the secondary nitric acid bubbling flask with cooling condenser of $4^{\circ}C$ under nitrogen stream of 20 mL/min flow rate. And the contents of copper, chromium and arsenic compounds in its pyrolysis such as carbonized CCA treated wood, 1st washing and 2nd washing liquors as well as its raw materials, were determined using ICP-AES. The results are as follows : 1. The yield of char in low-temperature pyrolysis reached about 50 percentage similar to the result of common pyrolytic process. 2. The higher the pyrolytic temperature was, the more the volatiles of CCA, and in particular, the arsenic compounds were to be further more volatile above $320^{\circ}C$, even though the more repetitive and sequential monitorings were necessary. 3. More than 85 percentage of CCA in CCA-treated wood was left in char in such low-temperature pyrolytic condition at $300^{\circ}C$. 4. Washing system for absorption of volatile CCA in this experiment required much more contacting time between volatile gases and water to prevent the loss of CCA compounds, especially the loss of arsenic compound. 5. Therefore, more complete recovery of CCA components in CCA-treated wood required the lower temperature than $320^{\circ}C$, and the longer contacting time of volatile gases and water needed the special washing and recovery system to separate the toxic and volatile arsenic compounds in vent gases.

Expressions of Matrix Metalloproteinase-9 and Tissue Inhibitor of Metalloproteinase-2 with Changes of Interleukin-6 and Interleukin-18 in Atherosclerotic Lesions of Hypercholesterolemic Rabbits (고콜레스테롤혈증 가토의 죽상경화성 병변에서 Interleukin-6와 Interleukin-18의 변화 및 Matrix Metalloproteinase-9과 Tissue Inhibitor of Metalloproteinase-2의 발현)

  • 권영무;김성숙;장봉현
    • Journal of Chest Surgery
    • /
    • v.35 no.6
    • /
    • pp.407-419
    • /
    • 2002
  • Atherosclerosis is a chronic inflammatory disease of the arterial wall characterized by progressive accumulation of lipids, cells, and extracellular matrix. Matrix metalloproteinases(MMPs) and tissue inhibitor of metalloproteinases(TIMPS) contribute to vascular matrix remodeling in atherosclerosis, and some cytokines may play role in the synthesis or activation of MMPs or TIMPs. Material and Method: We produced experimental atherosclerotic plaques in 9 rabbits by atherogenic hypercholesterol diet for 12 weeks, and 10 other rabbits were used as control group with standard laboratory chow, At that time, 19 rabbits were sacrificed and aorta, coronary arteries and blood specimens were prepared. The expressions of MMP-9, TIMP-2 and interleukin(IL)-18, and the bioactivity of IL-6 were investigated with H&E stain, immunohistochemical stain, immunoblotting(Western blot analysis), and bioassay. Result: Serum cholesterol in the experimental group increased up to 1258$\pm$262 mg/dL(control group: 41$\pm$7 mg/dL). All experimental group showed well-developed atherosclerotic plaques in aorta and coronary artery. The expression of MMP-9 in aorta and coronary artery of the experimental group showed significant increase than that of the control group by immunohistochemistry. Among the experimental group, complicated lesions with intimal rupture or complete luminal occlusion, demonstrated stronger expression of MMP-9. Interestingly, there was no difference in expression of TIMP-2 between the experimental and the control group. These findings were confirmed by Western blot analysis. The bioassay revealed significant up-regulation of serum bioactivity of IL-6 in the experimental group(4819.60$\pm$2021.25 IU/$m\ell$) compared to that of IL-6 in the control group(27.20 $\pm$ 12.19 IU/$m\ell$). IL-18 was expressed in all atherosclerotic plaques, whereas little or no expression was detected in the control group. Conclusion: The increased MMP-9 expression along with the unchanged TIMP-2 expression seem to be contributory factors in extracellular matrix degradation in atherosclerosis. Focal overexpression of MMP-9 may promote plaque destabilization and cause complications of atherosclerotic plaques such as thrombosis with/without acute coronary syndrome. Elevation of IL-6 and IL-18 may be more than just markers of atherosclerosis but actual participants in lesion development. Identification of critical regulatory pathway is important to improve the understanding of the cellular and molecular basis of atherosclerosis and may open the way for novel therapeutic strategies.

Effect of Magnesium Administration on Preventing Arrhythmias after Coronary Artery Bypass Graft (관상동맥 우회술 후 마그네슘 투여가 심 부정맥을 예방하는 효과)

  • Kim, Jun-Hyun;Song, Hyun;Kim, Yong-Hee;Lee, Eun-Sang;Lee, Jay-Won;Song, Myung-Kun
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.339-345
    • /
    • 1998
  • Arrhythmias are common after cardiac surgery and are multifactorial. Intravenous magnesium administration reduces the frequency of ventricular arrhythmias in patient with symptomatic heart failure or acute myocardial infarction. This study was designed to evaluate the role of magnesium in preventing PVCs(premature ventricular contractions) occurred frequently after coronary artery bypass graft(CABG). 50 consecutive patients were prospectively entered into a randomized trial to determine the efficacy of postoperative magnesium therapy on the incidence of cardiac arrhythmias after elective coronary artery bypass graft. The patients underwent coronary angiography, echocardiography, electrocardiography and clinical laboratory study preoperatively. Continuous electrocardiographic monitoring was done and magnesium level was checked 0, 3, 6, 12, 18, 24, 36, 48, 60 and 72 hours postoperatively. Study group of 25 patients were given 4g of magnesium continuously over the first 24 hours and then 2g/24hours from 25 to 72 hours. The clinical characteristics of both groups were similar(p<0.05). The preoperative mean serum magnesium concentration was similar in both study group, 1.59mg/dl and control group, 1.71mg/dl. The mean postoperative serum magnesium concentration in study group elevated significantly over postoperative 12hours through 36hours(p<0.05). The postoperative mean serum magnesium concentration in control group declined and remained significantly depressed over immediate postoperation through 72hours. The mean serum magnesium concentration was significantly greater in the study group compared with the control group over postoperative 3hours through 72hours(p<0.05). There was a significant decrease in the incidence of arrhythmias such as PVCs(p<0.01) which might jeopardize hemodynamics. There were no recognized adverse effects of magnesium Administration. In conclusion, prophylactic magnesium administration seems to lessen the incidence and severity of rrhythmias after coponary artery bypass graft.

  • PDF

The Role of Fas in Radiation Induced Apoptosis in vivo (방사선에 의한 Apoptosis에서 Fas의 역할)

  • Kim, Sung-Hee;Seong, Jin-Sil;Seong, Je-Kyung
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.246-252
    • /
    • 2002
  • Purpose : It has been recognized that interaction of the Fas : Fas ligand plays an important role in radiation-induced apoptosis. The purpose of this study was to investigate the role of Fas mutation in radiation-induced apoptosis in vivo. Materials and Method : Mice with mutations in Fas, $MRL/Mpj-Fas^{Ipr}$, and its normal control, MRL/Mpj, were used in this study. Eight-week old male mice were given whole body radiation. After irradiation, the mice were killed and their spleens were collected at different time intervals. Tissue samples were stained with hematoxylin-eosin and the numbers of apoptotic cells were scored. Regulating molecules of apoptosis including p53, Bcl-2, Bax, $Bcl-X_L,\;and\;Bcl-X_S$ were also analyzed by Western blotting. Results : At 25 Gy irradiation, the level of apoptosis reached the peak value at 8 hr after radiation and recovered to the normal value at 24 hr after radiation in MRL/Mpj mice. In contrast, the peak apoptosis level appeared at 4 hr after radiation in $MRL/Mpj-Fas^{Ipr}$. At 8 hr after radiation, the levels of apoptosis in MRL/Mpj mice and $MRL/Mpj-Fas^{Ipr}$ mice were $52.3{\pm}7.8\%\;and\;8.0{\pm}8.6\%$, respectively (p<0.05). The expression of apoptosis regulating molecules, p53, $Bcl-X_L\;and\;Bcl-X_S$, increased in MRL/Mpj mice in response to radiation; p53 with a peak level of 3-fold at 8 h, $Bcl-X_L$ with a peak level of 3.3-fold at 12 h, and $Bcl-X_S$ with a peak level of 3-fold at 12 h after 25 Gy radiation. Bcl-2 and Bax did not show significant change in MRL/Mpj mice. However in $MRL/Mpj-Fas^{Ipr}$ mice, the expression levels of p53, Bcl-2, Bax, $BCl-X_L\;and\;BCl-X_S$ showed no significant change. Conclusion : The level of radiation-induced apoptosis was lower in Fas mutated mice, Ipr, than in control mice. This seemed to be related to the lack of radiation-induced p53 activation in the Ipr mice. This result suggests that Fas plays an important role in radiation-induced apoptosis in vivo.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.