• 제목/요약/키워드: Lab-Scale Model

검색결과 172건 처리시간 0.036초

Pretest analysis of a prestressed concrete containment 1:3.2 scale model under thermal-pressure coupling conditions

  • Qingyu Yang;Jiachuan Yan;Feng Fan
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2069-2087
    • /
    • 2023
  • In nuclear power plant (NPP) accidents, the containment is subject to high temperatures and high internal pressures, which may further trigger serious chain accidents such as core meltdown and hydrogen explosion, resulting in a significantly higher accident level. Therefore, studying the mechanical performance of a containment under high temperature and high internal pressure is relevant to the safety of NPPs. Based on similarity principles, the 1:3.2 scale model of a prestressed concrete containment vessel (PCCV) of a NPP was designed. The loading method, which considers the thermal-pressure coupling conditions, was used. The mechanical response of the PCCV was investigated with a simultaneous increase in internal pressure and temperature, and the failure mechanism of the PCCV under thermal-pressure coupling conditions was revealed.

실구조물의 동특성 파악을 위한 축소모형에 적용되는 상사비 분석 (Analysis of Scaling Factor applied to Lab-Scale Model for Estimating Dynamic Characteristics of Real Structures)

  • 박건;윤형철;김성보
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권1호
    • /
    • pp.59-66
    • /
    • 2021
  • 세계적으로 자연재해의 빈도와 규모가 증가하고 있으며, 이러한 자연재해는 토목구조물에 다양한 손상을 유발할 수 있다. 이 중 가장 심각한 손상을 유발할 수 있는 자연 재해 중 하나가 지진이다. 따라서 지진에 대하여 구조물의 안전성을 확보하기 위해 다양한 연구들이 진행되고있다. 지진시 토목구조물의 안전성이나 메커니즘에 대한 연구는 대부분 축소모형실험을 바탕으로 진행되고 있으며, 이는 토목구조물의 규모를 고려하였을 때 실구조물실험이 불가능하기 때문이다. 이러한 축소모형연구에서는 Iai가 제안한 상사법칙이 주로 인용되고 있으나, Iai가 제안한 상사법칙을 적용할 경우 축소모델 제작에 필요한 구조부재의 선정에 많은 어려움이 따르게 된다. 이는 Iai가 제안한 상사비를 적용할 경우 구조물의 재료특성인 탄성계수에 상사비를 적용하여야 하기 때문이다. 따라서 이논문에서는 실제구조물과 동일한 재료특성을 갖는 축소모형에 적용되는 상사비를 Iai의 상사법칙에 근거하여 적용하고, 유한요소해석을 통하여 축소모형과 실구조의 동특성을 비교·분석하였다. 이 논문에서 적용한 상사법칙에 근거한 축소모형실험을 통해 산정된 구조물의 특성이 실구조물의 특성을 더욱 정확히 반영할 수 있을 것으로 판단된다.

Study on Multi-scale Unit Commitment Optimization in the Wind-Coal Intensive Power System

  • Ye, Xi;Qiao, Ying;Lu, Zongxiang;Min, Yong;Wang, Ningbo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1596-1604
    • /
    • 2013
  • Coordinating operation between large-scale wind power and thermal units in multiple time scale is an important problem to keep power balance, especially for the power grids mainly made up of large coal-fired units. The paper proposes a novel operation mode of multi-scale unit commitment (abbr. UC) that includes mid-term UC and day-ahead UC, which can take full advantage of insufficient flexibility and improve wind power accommodation. First, we introduce the concepts of multi-scale UC and then illustrate the benefits of introducing mid-term UC to the wind-coal intensive grid. The paper then formulates the mid-term UC model, proposes operation performance indices and validates the optimal operation mode by simulation cases. Compared with day-ahead UC only, the multi-scale UC mode could reduce the total generation cost and improve the wind power net benefit by decreasing the coal-fired units' on/off operation. The simulation results also show that the maximum total generation benefit should be pursued rather than the wind power utilization rate in wind-coal intensive system.

FK KoFlux 관측지에서의 지역 규모 열 플럭스의 추정 : 타워 관측에서 MM5 중규모 모형까지 (Inferring Regional Scale Surface Heat Flux around FK KoFlux Site: From One Point Tower Measurement to MM5 Mesoscale Model)

  • Jinkyu Hong;Hee Choon Lee;Joon Kim;Baekjo Kim;Chonho Cho;Seongju Lee
    • 한국농림기상학회지
    • /
    • 제5권2호
    • /
    • pp.138-149
    • /
    • 2003
  • KoFlux는 생태계와 대기 사이에 교환되는 이산화탄소, 수증기 및 에너지에 대한 우리의 이해를 높이고, FLUXNET과 CEOP등의 지역, 대륙 및 전구 규모의 관측망에 기여하기 위해서 시작되었다. 그거나 한반도의 지형적 특성 때문에 KoFlux의 대부분의 플럭스 타워는 관측에 이상적이지 못한 장소에 위치하고 있다. 탄소 및 에너지 교환의 정량화를 위해서 뿐만 아니라 군락 규모에서 지역 규모로 확장하기 위해서는 관측과 모델링을 병용한 다양한 접근 방법의 적용이 필요하다. 본 연구에서는 지역 규모의 현열 플럭스를 추정하기 위해 타워 플럭스 관측, 대류 경계층(CBL) 수지 방법, MM5 중규모 모형, 그리고 NCAR/NCEP 재분석 자료의 네 가지의 방법을 사용하여 다양한 면적을 대표하는 현열 플럭스를 산출하여 비교하였다. 비록 제한된 짧은 기간의 자료를 사용하였으나, 예비 분석을 통하여 (1) 해남 농경지 플럭스 타워에서 관측된 현열 플럭스가 지표의 불균질성을 보였고, (2) CBL 수지 방법으로 얻어진 지역 규모의 현열 플럭스는 수평 이류 효과의 계산 방법에 따라 다른 결과를 보였으며, (3) MM5 중규모 모형은 타워 플럭스 관측 값과 아주 유사한 현열 값을 수치 모사하였다. 그러나 관측지의 불균질성과 두 방법이 대표하는 면적의 근본적인 차이를 고려할 때, 플럭스 발자국 분석, 지리정보 시스템 및 관측지의 위성 영상 분석에 근거한 타워 플럭스의 공간 대표성을 정량화하는 것이 시급한 것으로 나타났다.

A Novel Method to Evaluate the Emotional Image Quality with CIECAM02

  • Chong, Jong-Ho;Lee, Seung-Bae;Park, Hye-Ryoung;Kim, Sang-Ho;Bae, Jae-Woo;Kim, Hye-Dong;Kim, Hun-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.47-50
    • /
    • 2008
  • We propose a new method evaluating the image quality of display devices using the CIECAM02 that is the recently developed CIE color appearance model and provides an extension of the previously recommended CIE color spaces. We develop the evaluation method that quantifies the color reproduction capability, emotional gray scale (gradation), and visual perception contrast (perceptual contrast range) based on the gamut in this model.

  • PDF

Evaluation on bridge dynamic properties and VIV performance based on wind tunnel test and field measurement

  • Yang, Yongxin;Ma, Tingting;Ge, Yaojun
    • Wind and Structures
    • /
    • 제20권6호
    • /
    • pp.719-737
    • /
    • 2015
  • Full scale measurement on the structural dynamic characteristics and Vortex-induced Vibrations (VIV) of a long-span suspension bridge with a central span of 1650 m were conducted. Different Finite Element (FE) modeling principles for the separated twin-box girder were compared and evaluated with the field vibration test results, and the double-spine model was determined to be the best simulation model, but certain modification still needs to be made which will affect the basic modeling parameters and the dynamic response prediction values of corresponding wind tunnel tests. Based on the FE modal analysis results, small-scaled and large-scaled sectional model tests were both carried out to investigate the VIV responses, and probable Reynolds Number effects or scale effect on VIV responses were presented. Based on the observed VIV modes in the field measurement, the VIV results obtained from sectional model tests were converted into those of the three-dimensional (3D) full-scale bridge and subsequently compared with field measurement results. It is indicated that the large-scaled sectional model test can probably provide a reasonable and effective prediction on VIV response.

Optimization of Energy Consumption in the Mobile Cloud Systems

  • Su, Pan;Shengping, Wang;Weiwei, Zhou;Shengmei, Liu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권9호
    • /
    • pp.4044-4062
    • /
    • 2016
  • We investigate the optimization of energy consumption in Mobile Cloud environment in this paper. In order to optimize the energy consumed by the CPUs in mobile devices, we put forward using the asymptotic time complexity (ATC) method to distinguish the computational complexities of the applications when they are executed in mobile devices. We propose a multi-scale scheme to quantize the channel gain and provide an improved dynamic transmission scheduling algorithm when offloading the applications to the cloud center, which has been proved to be helpful for reducing the mobile devices energy consumption. We give the energy estimation methods in both mobile execution model and cloud execution model. The numerical results suggest that energy consumed by the mobile devices can be remarkably saved with our proposed multi-scale scheme. Moreover, the results can be used as a guideline for the mobile devices to choose whether executing the application locally or offloading it to the cloud center.

Investigation and Simulation Study on the Cascading Trip-off Fault of a Large Number of Wind Turbines in China on May 14, 2012

  • Qiao, Ying;Lu, Zong-Xiang;Lu, Ji;Ruan, Jia-Yang;Wu, Lin-lin
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2240-2248
    • /
    • 2015
  • The integration of the large-scale wind power brings great challenge to the stability of the power grid. This paper investigates and studies the fault on May 14, 2012 of the large-scale cascading trip-off of wind turbines in North China. According to the characteristics of the voltage variation, the fault process is divided into three stages: the pre-event stage, the critical stage before cascading, and the cascading stage. The scenes in the fault are reproduced, using the full-size actual power system model. Simulation models of double-fed induction generators (DFIGs) and SVCs including protection settings and controller strategies are carefully chosen to find out the reason of voltage instability in each stage. Some voltage dynamic that have never been observed before in the faults of the same kind are analyzed in detail, and an equivalent voltage sensitive dynamic model of DFIG is proposed for the fast computation. The conclusions about the voltage dynamics are validated by the actual PMU observation evidence.

Vision-based technique for bolt-loosening detection in wind turbine tower

  • Park, Jae-Hyung;Huynh, Thanh-Canh;Choi, Sang-Hoon;Kim, Jeong-Tae
    • Wind and Structures
    • /
    • 제21권6호
    • /
    • pp.709-726
    • /
    • 2015
  • In this study, a novel vision-based bolt-loosening monitoring technique is proposed for bolted joints connecting tubular steel segments of the wind turbine tower (WTT) structure. Firstly, a bolt-loosening detection algorithm based on image processing techniques is developed. The algorithm consists of five steps: image acquisition, segmentation of each nut, line detection of each nut, nut angle estimation, and bolt-loosening detection. Secondly, experimental tests are conducted on a lab-scale bolted joint model under various bolt-loosening scenarios. The bolted joint model, which is consisted of a ring flange and 32 sets of bolt and nut, is used for simulating the real bolted joint connecting steel tower segments in the WTT. Finally, the feasibility of the proposed vision-based technique is evaluated by bolt-loosening monitoring in the lab-scale bolted joint model.

Experimental Verification of a Kinetic Model of Zr-Oxidation

  • Yoo, Han-Ill;Park, Sang-Hyun
    • 한국세라믹학회지
    • /
    • 제43권11호
    • /
    • pp.724-727
    • /
    • 2006
  • It has long been known that the oxidation kinetics of Zr-based alloys undergoes a crossover from parabolic to cubic in the pretransition period (before breakaway of the oxide scale). This kinetic crossover, however, is not fully understood yet. We have earlier proposed a model for the Zr-oxidation kinetics, in a closed form for the first time, by taking into account a compressive strain energy gradient as a diffusional driving force in addition to a chemical potential gradient of component oxygen across the ZrO$_2$ scale upon Zr [J. Nucl. Mater., 299 (2001) 235]. In this paper, we experimentally reconfirm the validity of the proposed model by using the thermogravimetric data on mass gain of Zr in a plate and wire form, respectively, in air atmosphere at different temperatures in the range of 500$^{\circ}$ to 800$^{\circ}C$, and subsequently report on the numerical values for oxygen chemical diffusivity and strain energy gradient across the oxide scale.