• Title/Summary/Keyword: LU2

Search Result 1,164, Processing Time 0.028 seconds

Effects of Flux and Ta5+ Substitution on the Photoluminescence of Lu(Nb,Ta)O4:Eu3+ Phosphors (융제 및 Ta5+ 치환이 Lu(Nb,Ta)O4:Eu3+ 형광체의 발광 특성에 미치는 영향)

  • Kim, Jiwon;Kim, Young Jin
    • Korean Journal of Materials Research
    • /
    • v.29 no.9
    • /
    • pp.559-566
    • /
    • 2019
  • $Lu(Nb,Ta)O_4:Eu^{3+}$ powders are synthesized by a solid-state reaction process using LiCl and $Li_2SO_4$ fluxes. The photoluminescence (PL) excitation spectra of the synthesized powders consist of broad bands at approximately 270 nm and sharp peaks in the near ultraviolet region, which are assigned to the $Nb^{5+}-O^{2-}$ charge transfer of $[NbO_4]^{3-}$ niobates and the f-f transition of $Eu^{3+}$, respectively. The PL emission spectra exhibit red peaks assigned to the $^5D_0{\rightarrow}^7F_J$ transitions of $Eu^{3+}$. The strongest peak is obtained at 614 nm ($^5D_0{\rightarrow}^7F_2$), indicating that the $Eu^{3+}$ ions are incorporated into the $Lu^{3+}$ asymmetric sites. The addition of fluxes causes the increase in emission intensity, and $Li_2SO_4$ flux is more effective for enhancement in emission intensity than is LiCl flux. The substitution of $Ta^{5+}$ for $Nb^{5+}$ results in an increase or decrease in the emission intensity of $LuNb_{1-x}Ta_xO_4:Eu^{3+}$ powders, depending on amount and kind of flux. The findings are explained using particle morphology, modification of the $[NbO_4]^{3-}$ structure, formation of substructure of $LuTaO_4$, and change in the crystal field surrounding the $Eu^{3+}$ ions.

Modeling the Impacts of Increased Urbanization on Local Meteorology in the Greater Seoul Area (수도권지역 도시화가 국지기상에 미치는 영향 모델링)

  • Kang, Yoon-Hee;Kim, Yoo-Keun;Oh, In-Bo;Hwang, Mi-Kyoung;Song, Sang-Keun
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1361-1374
    • /
    • 2010
  • The impact of urbanization on local meteorology (e.g., surface temperature, PBL height, wind speed, etc.) in the Greater Seoul Area (GSA) was quantitatively evaluated based on a numerical modeling approach during a 1-month period of 2001 (9 Sep. through 8 Oct. 2001). The analysis was carried out by two sets of simulation scenarios: (1) with the global land use and topographic data from the U.S. Geological Survey (USGS) in 1990s (i.e., LU-USGS case) and (2) with the land use data from the Environmental Geographic Information System (EGIS) along with the 3 sec elevation data from the Shuttle Radar Topography Mission (SRTM) in 2000s (i.e., LU-EGIS case). The extension of urban areas in the GSA (especially, the southern parts of Seoul) accounted for 1.8% in the LU-USGS case and 6.2% in the LU-EGIS case. For the simulations, the surface temperature and PBL height due to urbanization in the LU-EGIS case was higher (the differences of up to $0.1^{\circ}C$ and 36 m, respectively) than those in the LU-USGS case, whereas the wind speed (up to 0.3 $ms^{-1}$) in the former was lower than that in the latter at 1500 LST. The increase in surface temperature due to urbanization in the GSA (especially, the southern parts of Seoul) was led to the strong convergence of air masses, causing the early sea breeze and its rapid propagation to inland locations. In addition, the vertical mixing motion in the extended urban areas for the LU-EGIS case was predicted to be stronger than that for the LU-USGS case and vice versa for the original urban areas.

Characteristics of Acupuncture at LU10 on Abdominal Thermography of Health Subject (어제(魚際)(LU10) 자침(刺鍼)이 복부(腹部) 한열변화(寒熱變化)에 미치는 영향(影響))

  • Jeon Moon-Kee;Kim Jae-Hyo;Byun Kee-Won;Do Jin-Woo;Kim Kyung-Sik;Sohn In-Cheul
    • Korean Journal of Acupuncture
    • /
    • v.20 no.2
    • /
    • pp.1-20
    • /
    • 2003
  • This study was examined for characteristics of acupuncture of LU10 on the abdominal thermography of health subject. The volunteers who participating in this study had taken rest for 20 - 30 mins in room temperature $(23-25^{\circ}C)$ before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day. The thermography of abdomen including a below part of the chest was taken using Infra-Red Imaging System (IR 2000, MEDI-CORE Co., Korea) by time interval of 15 minutes at 15 min before, just before and 15 min after, 30 min after and 45 min after acupuncture stimulation. Acupuncture was applied to both LU10 for 30 mins. The results showed that acupuncture of LU10 for 30 mins had more potencies of changes on all the ROIs of abdominal thermography than those of control group. Also, those responses were significantly clear at the A1, A3, A6, A7 and A9 areas. It was observed that the quantities of thermal changes following acupuncture of LU10 been increased significantly comparing that of control group at the all ROIs (region of interest). These effects have more potencies at the upper (A1 and A2) and below (A7, A8, A9) abdominal areas than midline ones (A4, A5, and A6). These results suggest that acupuncture of LU10 having the characteristics of controls of chill and fever (寒熱) may modulate thermal distributions and changes of abdominal areas including the below of chest.

  • PDF

Advanced Program-to-Program Communication (APPC) 기능 분석

  • Lee, Mi-Seon;Nam, Sang-Woo;Son, Jin-Woo
    • Electronics and Telecommunications Trends
    • /
    • v.5 no.4
    • /
    • pp.120-133
    • /
    • 1990
  • APPC는 프로그램과 프로그램 사이의 통신을 위해 1982년 IBM에 의해 소개되었다. APPC의 구조적인 기초는 logical unit 6.2이다. 두 사용자가 서로 통신을 하려면 먼저 LU 사이의 세션(session)이 이루어져야 한다. LU 6.2에서의 기본은 conversation 개념이다. conversation은 통신하는 두 프로그램 사이의 연결로 두개의 통신하는 프로그램을 대표하는 두 LU 사이의 세션을 이용한다. conversation은 세션의 serial time slice이다.

Literature Study on the Composition of Samanhyeol (사만혈 구성 경혈에 대한 소고)

  • Seungtae Kim
    • Korean Journal of Acupuncture
    • /
    • v.41 no.2
    • /
    • pp.43-50
    • /
    • 2024
  • Objectives : Samanhyeol is a combination of acupoints located in the cubital and popliteal fossa. It is commonly used in clinical practice to treat acute illnesses such as summerheat stroke, vomiting, diarrhea, and hemorrhagic diseases. There are two types of Samanhyeol in literature: BL40 and LU5, and BL40 and PC3. We investigated which acupoint is representative of Samanhyeol, and more closely fits the definition of Samanhyeol between LU5 and PC3. Methods : We searched for literature related to Samanhyeol, compared the anatomical locations of LU5, PC3, and BL40, examined their indications associated with the effectiveness of Samanhyeol, and checked cases in the literature where LU5 or PC3 was used concurrently with BL40. Results : BL40, one of the Samanhyeol, has been used to treat summerheat stroke, vomiting, diarrhea, and epistaxis in acupuncture texts, and there are many references in the literature to BL40 being used for bloodletting. And BL40 is located in the midpoint of the traverse crease of the popliteal fossa. From this perspective, LU5 may be a more suitable than PC3 because it is located in the midpoint of the cubital crease. However, Samanhyeol is a combination of acupoints used to treat heat stroke, vomiting and diarrhea, and hemorrhagic diseases. Upon analyzing the literature, it was found that LU5 and PC3 have similar efficacy. However, PC3 was used more frequently in cases of severe fever, unconsciousness or syncope. Conclusions : Literature suggests that BL40 is the representative acupoint for Samanhyeol. And PC3 is more appropriate than LU5 for Samanhyeol because its effects are more stronger on heat stroke although both LU5 and PC3 can treat symptoms related to Samanhyeol.

Hypersonic Chemical Nonequilibrium Flow Analysis with HLLE+ and LU-AF (HLLE+와 LU-AF를 이용한 극초음속 화학적 비평형 유동장 해석)

  • Park Soo-Hyung;Kwon Jang Hyuk
    • Journal of computational fluids engineering
    • /
    • v.5 no.2
    • /
    • pp.47-54
    • /
    • 2000
  • A robust Navier-Stokes code has been developed to efficiently predict hypersonic flows in chemical nonequilibrium. The HLLE+ flux discretization scheme is used to improve accuracy and robustness of hypersonic flow analysis. An efficient LU approximate factorization method is also used to solve the flow equations and species continuity equations in fully coupled fashion to implicitly treat stiff source terms of chemical reactions. The HLLE+ scheme shows lower grid dependency for the wall heating rates than other schemes. The developed code has been used to compute chemical nonequilibrium air flow through expanding hypersonic nozzle and past two and three dimensional blunt-nosed bodies. The results are in good agreement with existing numerical and experimental results.

  • PDF

A Study on the Change of Body Temperature according to the Needle Remaining Time at LU9 - Through the D.I.T.I. Scan - (태연혈(太淵穴)의 유침 시간에 따른 체온 변화 -적외선체열촬영(赤外線體熱撮影)을 중심으로-)

  • Lee, Bong-Hyo;Lee, Kyung-Min;Park, Ji-Ha;Kim, Min-Seo;Kim, San-Deul;Park, Byeong-Gyu;Yang, Hyun-Dong;Yea, Sung-Ho;Lee, Ho-Jung;Choi, Jae-Won;Hong, Hye-Lin;Lee, Eun-Jung;Lim, Sung-Chul;Kim, Jae-Su;Lee, Yun-Kyu;Lee, Hyun-Jong;Jung, Tae-Young;Jung, Hyun-Jung;Kam, Chul-Woo
    • Korean Journal of Acupuncture
    • /
    • v.29 no.2
    • /
    • pp.188-199
    • /
    • 2012
  • Objectives : This study was performed to find the desirable remaining time of needle in the acupuncture treatment. Methods : The 21 volunteers were given acupuncture at LU9 vertically and needles were remained for 2 min, 10 min, 15 min, 30 min, respectively. The thermographic change induced by acupuncture was measured with Digital Infrared Thermographic Image at the following acupoints: LU11, LU10, LU9, LU8, LU5, LU1, and PC7. The statistical significance of thermographic change was evaluated using paired t-test and post hoc Wilcoxon test. Results : The most significant changes after acupuncture were produced when needles were remained for 10 min or 15 min. LU11, LU5, LU1, and PC7 were the point at which all of the remaining time produced significant change commonly. At LU11, the biggest change was produced when needle was remained for 15 min, while at LU5, LU1, and PC7, the biggest change was produced when needle was remained for 30 min, and the smallest change was produced when needle was remained for 10 min at all of acupoints of LU11, LU5, LU1, and PC7. The unbalance between left side and right was decreased the most largely in 15 min group. Conclusions : The results of this study suggest that the desirable remaining time of acupuncture needle might be 15 min.

Grouting Improvement through Correlation Analysis of Hydrogeology and Discontinuity Factors in a Jointed Rock-Mass (절리 암반의 수리지질 및 불연속면 특성 간 상관분석을 통한 그라우팅 계획 수립의 개선 방안)

  • Kwangmin Beck;Seonggan Jang;Seongwoo Jeong;Minjune Yang
    • The Journal of Engineering Geology
    • /
    • v.34 no.2
    • /
    • pp.279-294
    • /
    • 2024
  • Large-scale civil engineering structures such as dams require a systematic approach to jointed rock-mass grouting to prevent water leakage into the foundations and to ensure safe operation. In South Korea, rock grouting design often relies on the experience of field engineers that was gained in similar projects, highlighting the need for a more systematic and reliable approach. Rock-mass grouting is affected mainly by hydrogeology and the presence of discontinuities, involving factors such as the rock quality designation (RQD), joint spacing (Js), Lugeon value (Lu), and secondary permeability index (SPI). This study, based on data from field investigations of 14 domestic sites, analyzed the correlation between hydrogeological factors (Lu and SPI), discontinuity characteristics (RQD and Js), and grout take, and systematically established a design method for rock grouting. Analysis of correlation between the variables RQD, Js, Lu, and SPI yielded Pearson correlation (r) values as follows: Lu-SPI, 0.92; RQD-Lu, -0.75; RQD-Js, 0.69; RQD-SPI, -0.65; Js-Lu, -0.47; and SPI-Js, -0.41. The grout take increases with Lu and SPI values, but there is no significant correlation between RQD and Js. The proposed approach for grouting design based on SPI values was verified through analysis and comparison with actual curtain-grouting construction, and is expected to be useful in practical applications and future studies.

An Empirical Analysis on Labor Unions and Occupational Safety and Health Committees' Activity, and Their Relation to the Changes in Occupational Injury and Illness Rate

  • Yi, Kwan-Hyung;Cho, Hm-Hak;Kim, Ji-Yun
    • Safety and Health at Work
    • /
    • v.2 no.4
    • /
    • pp.321-327
    • /
    • 2011
  • Objectives: To find out from an analysis of empirical data the levels of influence, which a labor union (LU) and Occupational Safety and Health Committee (OSHC) have in reducing the occupational injury and illness rate (OIIR) through their accident prevention activities in manufacturing industries with five or more employees. Methods: The empirical data used in this study are the Occupational Safety and Health Tendency survey data, Occupational Accident Compensation data and labor productivity and sales data for the years 2003 to 2007. By matching these three sources of data, a final data set (n = 280) was developed and analyzed using SPSS version 18 (SPSS Inc., Chicago, IL, USA). Results: It was found that a workplace with a LU has a lower OIIR than one without a LU. In manufacturing industries with five or more employees in 2007, the OIIR of the workplaces without a LU was 0.87%, while that of workplaces with a LU was much lower at 0.45%. In addition, workplaces with an established OSHC had a lower OIIR than those without an OSHC. Conclusion: It was found that the OIIR of workplaces with a LU is lower than those without a LU. Moreover, those with the OSHC usually had a lower OIIR than those without. The workplace OIIR may have an impact on management performance because the rate is negatively correlated with labor productivity and sales. In the long run, the OIIR of workplaces will be reduced when workers and employers join forces and recognize that the safety and health activities of the workplace are necessary, not only for securing the health rights of the workers, but also for raising labor productivity.

A Study on the U(VI), Ca(II) and Lu(III) Metal Ions Utilizing Nitrogen-Donator Synthetic Resin (질소-주게 합성수지를 이용한 U(VI), Ca(II) 및 Lu(III) 금속 이온들에 관한 연구)

  • 정만태
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.1
    • /
    • pp.25-33
    • /
    • 2000
  • The new ion exchange resin was synthesized from chloromethylated styrene-1,4-divinylbenzene(DVB) with 1-aza-15-crown-5 macrocyclic ligand by substitution reaction. The effect of pH, time, dielectric constant of solvent and cross-linked of the matrix on the adsorption for $UO_2^{2+}$, $Ca^{2}$ and $Lu^{3+}$ was investigated. The metal ion was not adsorbed on the resins below pH 3 but above pH 4 fast adsorption behavior was showed. The optimum equilibrium time for adsorption of metallic ions was two hours. The adsorption selectivity determined in ethanol matrix was in increasing order $UO_2^{2+}>Ca^{2}>Lu^{3+}$. The adsorption power was in the order of 1%, 2%, 10% and 20% -crosslinked resin, but adsorption properties of resins decreased in proportion to the order of dielectric constant of solvents used. In addition, these metal ions could be separated in the column packed with 1% crosslinked resin by pH2.5 $HNO_3$ as an eluent.

  • PDF