• Title/Summary/Keyword: LTS

Search Result 183, Processing Time 0.034 seconds

Validity and Reliability of the Life Transition Scale in Parents of Disabled Children Across the Life Transition Process

  • Hong, Sun Woo;Kim, JinShil;Bang, Hwal Lan
    • Child Health Nursing Research
    • /
    • v.26 no.3
    • /
    • pp.338-347
    • /
    • 2020
  • Purpose: The Life Transition Scale (LTS) consists of 24 items that assess the life transition process of parents of autistic children. This study aimed to examine the validity and reliability of the LTS in parents of children with a wide spectrum of disabilities. Methods: Data were collected from 260 parents of children with disabilities through self-report questionnaires. Validity was examined using exploratory and confirmative factor analysis to determine the factor structures of the LTS; socio-demographic differences in LTS scores were examined using the t-test or ANOVA. Reliability was examined using Cronbach's α coefficient. Results: A four-factor structure was validated (χ2=640.0, p<.001, GFI=.81, RMSEA=.07, NNFI=.89, CFI=.89, PNFI=.74, Q [χ2/df]=2.60). The validity of the LTS was verified by exploratory factor analysis, with factor loading ranging from .30 to .80. There were significant differences in the accepting phase according to children's and parents' age and the type of disability, and in the wandering phase according to parental gender, educational level, job, and socioeconomic status. The Cronbach's αs for the reliability of each of the four structures were acceptable, within a range of .80~.90. Conclusion: The LTS is a valid and reliable measurement to assess the life transition process of parents with disabled children.

An Action-based LTS Bounded Model Checker for Analyzing Concurrency (병행성 분석을 위한 액션 기반의 LTS 바운드 모델 체커)

  • Park, Sa-Choun;Kwon, Gi-Hwon
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.9
    • /
    • pp.529-537
    • /
    • 2008
  • Since concurrent software is hard to debug, the verification of such systems inevitably needs automatic tools which support exhaustive searching. Bounded Model Checking (BMC) is one of them. Within a bound k, BMC exhaustively check some errors in execution traces of the given system. In this paper, we introduce the tool that performs BMC for LTS, modeling language for concurrent programs. In this tool, a property is described by a FLTL formula, which is suitable to present the property with actions in a LTS model. To experiment with existential model checkers and out tool, we compare and analysis the performance of the developed tool and others.

Performance Characteristics of a Loop Thermosyphon for Heat Source Cooling (열원 냉각용 루프 써모사이폰의 작동 특성)

  • Choi, Du-Sung;Song, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1475-1483
    • /
    • 2004
  • Loop thermosyphon(LTS) has many good characteristics such as low thermal resistance, no power consumption, noiseless operation and small size. To investigate the overall performance of LTS, we have performed various experiments varying three parameters: input power of the heater, working fluid(water, ethanol, FC3283) and filling ratio of the working fluid. At a combination of these parameters, temperature measurements are made at many locations of the LTS. The temperature difference between the evaporator and the condenser is used to obtain the thermal resistance. In addition, flow visualization using a high speed camera is carried out. The thermal resistance is not constant. It is lower at higher input power, which is one of the distinct merits of LTS. Flow instabilities are frequently observed when changing the working fluid, the input power and the filling ratio. The results show that the LTS can be readily put into practical use. Future practical application in electronic cooling is recommended.

LTS Semantics Model of Event-B Synchronization Control Flow Design Patterns

  • Peng, Han;Du, Chenglie;Rao, Lei;Liu, Zhouzhou
    • Journal of Information Processing Systems
    • /
    • v.15 no.3
    • /
    • pp.570-592
    • /
    • 2019
  • The Event-B design pattern is an excellent way to quickly develop a formal model of the system. Researchers have proposed a number of Event-B design patterns, but they all lack formal behavior semantics. This makes the analysis, verification, and simulation of the behavior of the Event-B model very difficult, especially for the control-intensive systems. In this paper, we propose a novel method to transform the Event-B synchronous control flow design pattern into the labeled transition system (LTS) behavior model. Then we map the design pattern instantiation process of Event-B to the instantiation process of LTS model and get the LTS behavior semantic model of Event-B model of a multi-level complex control system. Finally, we verify the linear temporal logic behavior properties of the LTS model. The experimental results show that the analysis and simulation of system behavior become easier and the verification of the behavior properties of the system become convenient after the Event-B model is converted to the LTS model.

Pre-hospitalization Advanced Airway Management Using The KING LTS-DTM and the LMA ProSealTM (LTS와 LMA를 이용한 병원 전 전문 기도 관리 연구)

  • Choi, Uk-Jin;Shim, Gyu-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5893-5900
    • /
    • 2012
  • It is very critical to promptly maintain airway of cardiac arrest cases or serious traumatic cases. The purpose of this study is to compare intubation rate, successful rate and pre-/post-education self-confidence between laryngeal tube (LTS) and proseal laryngeal mask (PLMA), so that it may contribute to improving the ability of 119 emergency team - a pivotal role in pre-hospitalization process - to carry out advanced airway management. In order to achieve the purpose, total 60 paramedics (Class I) who worked for incumbent 119 emergency team were asked to join a practical experiment and were also divided into two groups (LTS group: 30 people, PLMA group: 30 people). In details, they were all asked to take 3 sessions of practice (5 minutes per session) using dummy model to quantitatively measure the time and success/failure of intubation and the change of their self-confidence. As a result, it was found that there were statistically significant differences in the time of intubation between LTS and PLMA group (p=.000), but there was no significant difference in the rate of successful intubation between these two groups, and self-confidence of two groups tended to significantly increase after experiment (p=.000). Conclusively, if it is necessary to promptly apply intubation to traumatic cases with immobilized cervical vertebral and lingual edema, LTS can be useful as an effective means of intubation. And it is expected that continuing intubation training using LTS will improve the ability of emergency team to perform advanced airway management for traumatic cases.

A design study of a 4.7 T 85 mm low temperature superconductor magnet for a nuclear magnetic resonance spectrometer

  • Bae, Ryunjun;Lee, Jung Tae;Park, Jeonghwan;Choi, Kibum;Hahn, Seungyong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.24-29
    • /
    • 2022
  • One of the recent proposals with nuclear magnetic resonance (NMR) is a multi-bore NMR which consists of array of magnets which could present possibilities to quickly cope with pandemic virus by multiple inspection of virus samples. Low temperature superconductor (LTS) can be a candidate for mass production of the magnet due to its low price in fabrication as well as operation by applying the helium zero boil-off technology. However, training feature of LTS magnet still hinders the low cost operation due to multiple boil-offs during premature quenches. Thus in this paper, LTS magnet with low mechanical stress is designed targeting the "training-free" LTS magnet for mass production of magnet array for multi-bore NMR. A thorough process of an LTS magnet design is conducted, including the analyses as the followings: electromagnetics, mechanical stress, cryogenics, stability, and protection. The magnet specification was set to 4.7 T in a winding bore of 85 mm, corresponding to the MR frequency of 200 MHz. The stress level is tolerable with respect to the wire yield strength and epoxy crack where mechanical disturbance is less than the minimum quench energy.

The design of HTS insert coil and LTS background magnet for NMR research (NMR 연구를 위한 HTS insert coil 및 LTS background magnet 설계)

  • Choi, Suk-Jin;Hwang, Young-Jin;Kim, Young-Jae;Chang, Ki-Sung;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.744_745
    • /
    • 2009
  • 고해상도의 NMR 연구 개발을 위해서는 고자장의 마그넷연구가 선행되어야 한다. 고자장을 구현하기 위해서는 저온초전도체를 이용한 마그넷뿐만이 아니라 고온초전도체를 이용한 인서트 코일의 연구가 필요하다. 연세대학교에서는 국가지정연구실사업으로 단백질 구조 규명의 초고자장 NMR 실현을 위한 고온초전도 인서트 코일 기술연구를 진행하고 있다. 본 논문에서는 고온초전도 인서트 코일 연구를 위해 제작할 LTS background magnet과 HTS 인서트 코일에 대한 전자장 해석을 진행하였다. 균일도나 선재 사양 등의 주요 변수 등을 고려하여 LTS background magnet과 HTS 인서트 코일에 적합한 사양을 결정하도록 하였다.

  • PDF

Laryngotracheal Separation for Chronic Intractable Aspiration (만성 흡인에 대한 후두기관 분리술의 유용성)

  • 이강진;성명훈;박범정;성원진;노종렬;민양기;이철희;이재서;김광현
    • Korean Journal of Bronchoesophagology
    • /
    • v.7 no.2
    • /
    • pp.140-145
    • /
    • 2001
  • Background and Objectives: Intractable aspiration in patients with impaired protective function of the larynx often results in multiple episode of aspiration pneumonia, repeated hospitalizations and expensive nursing care. The purpose of this study was to review the authors’experience and Patient outcome with the laryngotracheal separation (LTS) procedure. Materials and Methods A retrospective review of 9 patients who underwent LTS between 1996 and 2001 was conducted. Ages ranged from 3 to 72 years. Results : Seven patients were expected to have morbid aspiration as a consequence of acquired neurologic injuries and two were congenital neurologic injuries. Two patients had a postoperative fistula, which was well controlled with local wound care and minor procedure. Following LTS, aspiration was effectively controlled in all patients and four were able to tolerate a regular diet. Conclusion : LTS is a low-risk, successful. definitive procedure which decreases the potential for aspiration, pulmonary complication, hospitalizations and increases quality of life, especially in patent with irreversible upper airway dysfunction and Poor speech potential.

  • PDF

FVTD-LTS Method for Electromagnetic Field Analysis by Dielectric with large Permittivity (큰 유전율을 가지는 유전체의 전자계 해석을 위한 FVTD-LTS 기법)

  • Yoon, Kwang-Yeol;Chai, Yong-Yoong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.6
    • /
    • pp.334-338
    • /
    • 2006
  • The finite volume time domain(FVTD) method gives accurate results for the calculation of electromagnetic wave propagation but it should be noted that the number of sampling points per wavelength should be increased when more accurate numerical results are required. Moreover it requires large amount of computer memory resources. In this paper we propose a modified FVTD that employs a time subdivision. The local time-subdivided FVTD(FVTD-LTS) method is enough to divide the space domain grid with a large step size. This method can reduce computation time and memory resources. To validate the proposed method, sever numerical examples are presented. We have then shown that the proposed method yields a reasonable solution.