• Title/Summary/Keyword: LSC method

Search Result 65, Processing Time 0.029 seconds

Tilt Measurement of Drilling Machine Using the Laser Interferometer (레이저 간섭계를 이용한 드릴링 머신의 틸트 측정)

  • 이승수;손영지;김순경;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.479-484
    • /
    • 1996
  • This paper describes a method of measuring tilt motion. This method measures the tilt motion of drilling machines using a laser interferometer, a simple sliding linear bearing, measurement of the probe and the LSC(least square center) method. The next order of business is discussing the procedure of measurement. First, The measured position is considered to be the point of contact between the drill shank and the probe. The revolution of the drill axis delivers the point of contact to the probe. Second, because the laser interferometer is attached on the sliding linear bearing, any movement of probe influences laser reflector. Thus, the laser program displays the moving factor of laser reflector. Namely, this is tilt factor. Third. the points of measurement are a full circle which has 8 points (each are 45$^{\circ}$), After it is finished measuring the 8 points, let the spindle of the drilling machine move down about 5 cm. Repeating this procedure three times, we can get tilt motion's values which are calculated by LSC method. Many error factors affect the accurate measurement of tilt motion. However in this paper we ignore some error factors because they are less significant than tilt motion.

  • PDF

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

A Study on the 3D Modelling and Transference of Scaning Data using LSC Method (LSC를 이용한 스캔데이터 변환 및 3차원 모델 생성에 관한 연구)

  • 김민주;이승수;박정보;김순경;전언찬
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.387-392
    • /
    • 2001
  • This paper is to model a 30-shape product applying mathematically the data acquired from a 3D scanner and using an Automatic Design Program. The research studied in th reverse engineering up to now has been developed continuously and surprisingly. However, forming 3D-shape solid models in CAE and CAM, based on the research, the study leaves much to be desired. Especially, analyses and studies reverse-designing automatically using measured data after manufacturing. Consequently, we are going to acquire geometric data using an 3D scanner in this study with which we will open a new field of reverse engineering by a program which can design a 3D-shape solid model in a CAD-based program automatically.

  • PDF

Comparison of the Quantulus 1220 and 300SL Liquid Scintillation Counters for the Analysis of 222Rn in Groundwater

  • Kim, Hyuncheol;Jung, Yoonhee;Lee, Wanno;Choi, Guen-Sik;Chung, Kun Ho;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.395-401
    • /
    • 2016
  • Background: Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting $^{222}Rn$ in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect $^{222}Rn$ in groundwater. Materials and Methods: The Quantulus 1220 and 300SL were used to detect the presence of $^{222}Rn$. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a $^{222}Rn$ calibration source prepared with a $^{226}Ra$ source. Results and Discussion: The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was $0.08Bq{\cdot}L^{-1}$, while that of the 300SL was $0.20Bq{\cdot}L^{-1}$. The analytical results regarding $^{222}Rn$ in groundwater were less than 10% different between these LSCs. Conclusion: The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting $^{222}Rn$ in groundwater. Both LSCs can be applied to determine the levels of $^{222}Rn$ in groundwater under the management of the Ministry of Environment.

Characteristics of LSC coated Metallic Interconnect for Solid Oxide Fuel Cell (LSC가 코팅된 고체산화물 연료전지용 금속연결재의 특성 연구)

  • Pyo, Seong-Soo;Lee, Seung-Bok;Lim, Tak-Hyoung;Park, Seok-Joo;Song, Rak-Hyun;Shin, Dong-Ryul
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.172-177
    • /
    • 2010
  • This study reports the high-temperature oxidation kinetics, ASR(area specific resistance), and interfacial microstructure of metallic interconnects coated with conductive oxides in oxidation atmosphere at $800^{\circ}C$, The conductive material LSC($La_{0.8}Sr_{0.2}CoO_3$, prepared by Solid State Reaction) was coated on the Crofer22APU. The contact behavior of coating layer/metal substrate was increased by sandblast. The electrical conductivity of the LSC coated Crpfer22APU was measured by a DC two probe four wire method for 4000hr, in air at $800^{\circ}C$. Microstructure and composition of the coated layer interface were investigated by SEM/EDS. These results show that a coated LSC layer prevents the formation and growth of oxide scale such as $Cr_2O_3$ and enhances the long-term stability and electrical performance of metallic interconnects for SOFCs.

Comparison in Seed and Sprout Quality under Different Cropping Patterns in Mungbean (재배방식에 따른 녹두 종실과 나물의 품질변화)

  • Kim, Dong-Kwan;Son, Dong-Mo;Choi, Jin-Gyung;Shin, Hae-Ryong;Chon, Sang-Uk;Lee, Kyung-Dong;Jung, Ki-Yeol;Rim, Yo-Sup
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.56 no.3
    • /
    • pp.212-218
    • /
    • 2011
  • This study was performed to determine the relative quality of mungbeans harvested in bulk after applying a labor-saving cultivation (LSC) method, compared to mungbeans harvested three different times under the conventional cultivation condition. There was no significant difference in starch, crude protein, and vitexin or isovitexin content of seed according to the cropping system or harvest time. The mungbeans grown under the LSC method had the highest crude fat content, followed by mungbeans from the third-, the second- and the first-harvest mungbeans under the conventional cultivation. No significant difference was found in the composite ratio of saturated fatty acids to unsaturated fatty acids according to cropping system or harvest time. The second-harvest mungbeans grown under the conventional cultivation condition had 17 different types of fatty acids, while the third-harvest mungbeans grown under the conventional cultivation and those grown under the LSC condition had the fewest types of fatty acids with 12. Of the major saturated fatty acids, palmitic acid and arachidonic acid had the highest composite ratio in the first conventional cultivation followed by the second, the third and the LSC. However, stearic acid showed the opposite tendency. Of the major unsaturated fatty acids, linoleic acid had the highest composite ratio in the first conventional cultivation, followed by the second and third conventional cultivation and the LSC. Amylogram characteristics of the mungbeans were significantly different according to cropping system and harvest times. The mungbeans harvested after the first conventional cultivation had significantly higher pasting temperature, peak viscosity, holding strength viscosity, final viscosity and breakdown, while mungbeans harvested after the third conventional cultivation had significantly higher setback viscosity. In contrast, the mungbeans harvested under the LSC methods had a significantly lower amylogram value. When harvest rate, color values and amino acid content of sprout were measured, mungbeans grown under the LSC conditions had a low harvest rate of sprout, but had Hunter's color values and amino acid content of sprout similar to those of mungbeans grown under the conventional cultivation condition.

A Comprehensive Harmonic Rejection for DFIG Feeding Non-Linear Loads in Stand-Alone Applications

  • Nguyen, Ngoc-Tung;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.258-259
    • /
    • 2012
  • This paper proposes a new control strategy to eliminate the harmonic components of stator current for stand-alone DFIG system feeding non-linear loads. In this method, the LSC operates as an active filter which is controlled by employing a proportional-integral and a resonant controller. And also, the stator current is used as the feedback signal for the compensator instead of the load current, so that the additional current sensor at the load side can be removed. The experiment is verified to validate the effectiveness of the proposed compensating method.

  • PDF

Property Analysis of Ceramic Interconnect Prepared by Thermal Plasma Spray Coating Method for SOFC (Thermal Plasma Spray Coating 법에 의해 코팅된 SOFC용 세라믹 연결재 특성 분석)

  • Park, Kwang-Yeon;Pi, Seuk-Hoon;Lee, Jong-Won;Lee, Seung-Bok;Lim, Tak-Hyoung;Park, Seok-Joo;Song, Rak-Hyun;Shin, Dong-Ryul
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.710-714
    • /
    • 2011
  • In present work, $La_{0.8}Ca_{0.2}CrO_{3}$(LCC), $La_{0.8}Sr_{0.2}CrO_{3}$(LSC) and $La_{0.8}Ca_{0.2}CrO_{0.9}Co_{0.1}O_{3}$(LCCC) ceramic interconnect layer for SOFC were prepared by using thermal plasma spray coating process. The LCC, LSC and LCCC powders were characterized by x-ray diffraction(XRD), scanning electron microscopy(SEM), particle counter and BET analysis. In addition, basic and essential properties such as the surface morphology, cross section, gas leak rate, and electrical conductivity of LCC, LSC, and LCCC layers coated by thermal plasma spray coating process were analyzed and discussed. Based on these experimental results, it can be concluded that the LCCC layer coated by thermal plasma spray coating process can be suitable as a ceramic interconnect of SOFC.

Developing a Reactive System Model from a Scenario-Based Specification Model (시나리오 기반 명세 모델로부터 반응형 시스템 모델 개발)

  • Kwon, Ryoung-Kwo;Kwon, Gi-Hwon
    • Journal of Internet Computing and Services
    • /
    • v.13 no.1
    • /
    • pp.99-106
    • /
    • 2012
  • It is an important and a difficult task to analyze external inputs and interactions between objects for designing and modeling a reactive system consisting of multiple object. Also the reactive system is required huge efforts on confirm it can satisfy requirements under all possible circumstances. In this paper, we build from requirements to a scenario-based specification model using LSC(Live Sequence Chart) extending MSC(Message Sequence Chart) with richer syntax and semantic. Then the reactive system model satisfying all requirements for each object in this system can be automatically created through LTL Synthesis. Finally, we propose a method of reactive system development by iterative process transforming a reactive system model to codes.

Tritium extraction in aluminum metal by heating method without melting

  • Kang, Ki Joon;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.469-478
    • /
    • 2022
  • Tritium was extracted from tritium-contaminated aluminum samples by heating it in a high-temperature furnace at 200, 300, or 400 ℃ for 15 h. The extracted tritium was analyzed by using a liquid scintillation counter (LSC); the sample thicknesses were 0.4 and 2 mm. The differences in tritium extraction over time were also investigated by cutting aluminum stick samples into several pieces (1, 5, 10, and 15) with the same thickness, and subsequently heating them. The results revealed that there are most of the hydrated material based on tritium on the surface of aluminum. When the temperature was increased from 200 or 300 ℃-400 ℃, there are no large differences in the heating duration required for the radioactivity concentration to be lower than the MDA value. Additionally, at the same thickness, because the surface of aluminum is only contaminated to tritiated water, cutting the aluminum samples into several pieces (5, 10, and 15) did not have a substantial effect on the tritium extraction fraction at any of the applied heating temperatures (200, 300, or 400 ℃). The proportion of each tritium-release materials (aluminum hydrate based on tritium) were investigated via diverse analyses (LSC, XRD, and SEM-EDS).