• Title/Summary/Keyword: LSC

Search Result 167, Processing Time 0.029 seconds

The complete plastid genome of Scopolia parviflora (Dunn.) Nakai (Solanaceae)

  • Park, Jin Hee;Lee, Jungho
    • Korean Journal of Plant Taxonomy
    • /
    • v.46 no.1
    • /
    • pp.60-64
    • /
    • 2016
  • Scopolia parviflora of the family Solanaceae is an endemic species of Korea and a traditional Korean medicinal plant. The plastid genome was sequenced by next-generation sequencing (NGS) method. The characterized cp genome is 156,193 bp in size; the large single-copy (LSC) region is 86,364 bp, the inverted repeat (IR) is 25,905 bp, and the small single copy (SSC) region is 18,019 bp. The overall GC content of the plastid genome amounts to 37.61%. The cp genome contains 113 genes and 21 introns, including 80 proteincoding genes, four RNA genes, 30 tRNA genes, 20 group II introns, and one group I intron. A phylogenetic analysis showed that Scopolia parviflora was closely related to Hyoscyamus niger.

Streamlined Rotors Mini Rotorcraft : Trajectory Generation and Tracking

  • Beji Lotfi;Abichou Azgal
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.87-99
    • /
    • 2005
  • We present in this paper the stabilization (tracking) with motion planning of the six independent configurations of a mini unmanned areal vehicle equipped with four streamlined rotors. Naturally, the yaw-dynamic can be stabilized without difficulties and independently of other motions. The remaining dynamics are linearly approximated around a small roll and pitch angles. It will be shown that the system presents a flat output that is likely to be useful in the motion generation problem. The tracking feedback controller is based on receding horizon point to point steering. The resulting controller involves the lift (collective) time derivative for what flatness and feedback linearization are used. Simulation tests are performed to progress in a region with approximatively ten-meter-buildings.

The complete chloroplast genome of Polygonatum falcatum (Asparagaceae)

  • CHOI, Tae-Young;YUN, Se-Hyun;LEE, Soo-Rang
    • Korean Journal of Plant Taxonomy
    • /
    • v.52 no.1
    • /
    • pp.80-83
    • /
    • 2022
  • Polygonatum falcatum is a perennial herb distributed in East Asia. We determined the characteristics of the complete chloroplast genome in P. falcatum for the first time, with a de novo assembly strategy. The chloroplast genome was 154,579bp in length harboring 87 protein coding genes, 38 tRNA genes and eight rRNA genes. It exhibits typical quadripartite structure comprising a large single-copy (LSC) (83,528bp), a small single-copy (SSC) (18,457bp) and a pair of inverted repeats (IRs) (26,297bp). Phylogenetic analysis of 16 chloroplast genomes from Asparagaceae reveals that the genus Polygonatum is a monophyletic group and that P. falcatum is clustered together with the congener, P. odoratum.

The chloroplast genome sequence of Viola kusanoana (큰졸방제비꽃(Viola kusanoana)의 엽록체 염기서열 분석)

  • Ah-reum Go;Ki-Oug Yoo
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2021.04a
    • /
    • pp.22-22
    • /
    • 2021
  • 큰졸방제비꽃(Viola kusanoana)의 엽록체 DNA 염기서열을 밝히고자 차세대염기서열분석법(NGS)을 이용하여 분석하였다. 재료는 경상북도 울릉군 나리분지에 자생하는 개체의 잎을 사용하였다. 염기서열 분석결과, 총 길이는 158,644 bp 였고, GC함량은 36.3%로 분석되었다. 구간별로는 LSC (Large single copy)지역이 86,999 bp (GC content: 33.9%)였고 SSC (Small single copy)지역은 17,439 bp (GC content: 29.9%)으로 분석되었으며 IR (Invertied repeats)지역은 27,103 bp (GC content: 42.2%)로 확인되었다. 유전자는 protein coding gene 77개, tRNA gene 30개, rRNA 4개 등 총 111개로 이는 선행 연구된 제비꽃속 8개 분류군과 유전자의 순서와 방향이 모두 일치하였다. 이를 통해 제비꽃속의 엽록체 게놈의 유전자는 상당히 보존되어 있음을 확인하였다.

  • PDF

Relation of Stream Shape Complexity to Land Use, Water Quality and Benthic Diatoms in the Seom River Watershed (섬강 수계에서 하천 형태복잡도와 토지이용, 수질 및 부착규조류 군집 분포와의 관계)

  • Min, Han-Na;Kim, Nan-Young;Kim, Mi-Kyung;Lee, Sang-Woo;Hwang, Kil-Soon;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.1
    • /
    • pp.110-122
    • /
    • 2012
  • This study examined the benthic diatom community distribution, land cover/use and water quality in relation to stream shape complexity (SSC) in the Seom River watershed. SSC showed a significant relation to the riparian land cover/use pattern and also water quality variables of the studied streams. Streams with high stream shape complexity (HSC) appeared to have a high proportion of forest and farmland, while streams having a low stream shape complexity (LSC) appeared to have high proportion of city. Streams with lower SSC showed higher nutrients concentration in the stream waters. Benthic diatom species composition and dominant species appeared to be similar regardless of SSC differences among the studied streams, while the variation of diatom density was manifested with SSC. The relative abundance of dominant benthic diatoms varied with SSC. Saprophilic diatoms were dominant in the streams of LSC, while saproxenic diatoms were dominant in the streams of HSC. During the evaluation of biological water quality using the benthic diatom indices, Trophic Diatom Index (TDI) and Diatom Assemblage Index to organic water pollution (DAIpo), the streams of LSC generally showed poorer water quality than those of MSC (Middle stream shape complexity) and HSC. In particular, BOD, TP, and $PO_4$-P showed significant relationships with DAIpo. In conclusion, shape complexity of streams in the Seom River watershed showed a close relation with benthic diatom distribution. This relation seemed to primarily be resulted from the effect of proximate factors, such as water quality, which might be affected by the land use types determining the degree of SSC.

Study on Temporal Decay Characteristics of Naturally Occurring Radionuclides in Groudwater in Two Mica Granite Area (복운모화강암지역 지하수 중 자연방사성 물질의 경시적 붕괴특성 연구)

  • Kim, Moon Su;Kim, Tae Seung;Kim, Hyun Koo;Kim, Dong Su;Jeong, Do Hwan;Ju, Byoung Kyu;Hong, Jung Ki;Kim, Hye Jin;Park, Sun Hwa;Jeong, Chan Ho;Cho, Byong Wook;Han, Jin Seok
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.4
    • /
    • pp.19-31
    • /
    • 2013
  • To figure out the decay characteristics of naturally occurring radionuclides, eight sampled groundwaters from a monitoring borehole having high levels of uranium and radon concentrations in a two mica granitic area have analyzed by liquid scintillation counters (LSC) for over 1 year. In December 2011, three groundwater samples (DJ1, DJ2, DJ3) were obtained from each aquifer system located at -20 m, -40 m, -60 m of the monitoring borehole below the ground surface, respectively. Five samples (DJ4, DJ5, DJ6, DJ7, DJ8) were additionally gained from each aquifer positioned -20 m, -40 m, -60 m, -100 m, -105 m of the borehole in February 2012, respectively. Temporal variation characteristics of uranium and radon concentrations have showed over maximum 2.1 times and 1.4 times fluctuations of the values in the same sampling intervals over time, respectively. The intervals of -40 m and -105 m in the borehole have the highest values of uranium and radon concentrations, respectively. This may imply that the concentrations of naturally occurring radionuclides such as uranium and radon in groundwater have been changed over time and indicate that the qualities of groundwaters from the aquifers developed at each interval in the borehole are different each other. This discrepancy, moreover, could be caused by behaviour differences between uranium which is in ionic status having a half life of 4.6 billion years and is transported along with the flowing groundwater, and radon which is in gaseous status having a 3.82 day's half life in the aquifer systems. Physicochemical characteristics of groundwaters from the aquifer systems could be identified by the results of the on-situ measuring items such as pH and Eh, and the major ionic contents. The CPM values of eight groundwater samples analysed by LSC over one year have shown not to follow the theoretical decay curve of the radon. The CPM values of the samples have ranged from 2 to 7.5 after it had passed two months when the theoretical CPM values of the radon started zero since the initial analysis. Alpha and beta particle spectrums have shown the peaks of radium-226, however they have not revealed any peaks of radon and it's daughter products such as polonium-218 and 214, bismuth-214 for the late stage of the analysis. This implies that the groundwater from the borehole may contain radium-226 having a half life of 1,600 years which decays continuously.

Study on 222Rn reduction rate in boiling groundwater (가열에 의한 지하수 중 222Rn 제거율 고찰)

  • Kim, MoonSu;Kim, Hyun-Koo;Park, Sun-Wha;Kim, Hyoung-Seop;Ju, Byoung-Kyu;Kim, Dong-Su;Cho, Sung-Jin;Yang, Jae-Ha;Kwon, Oh-Sang;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.353-360
    • /
    • 2015
  • Boiling is an efficient removal method to reduce radon in groundwater when ventilating indoor air. 13 groundwater samples with various radon concentrations were used to evaluate the reduction rate of radon with heating temperature and time. The groundwater samples were obtained by Bladder pump and on-situ measurements such as dissolved oxygen (DO) and hydrogen concentration (pH) and so on were carried out by a flow cell system isolated from the ambient atmosphere environment. All samples for measuring radon in groundwater were analyzed by liquid scintillation counter (LSC). The experiment result showed that increasing groundwater temperature enhanced radon removal rate but the initial radon concentration with high level lowered the removal rate. This means that radon reduction in groundwater by heating needs more heating energy and longer heating time with radon concentrations. Radon removal rate in groundwater, therefore, mainly depends on the initial radon concentration, heating temperature, and heating time.

Follow-up of Exogenous DNA by Sperm-mediated Gene Transfer via Liposome

  • Cho, Hwang-Yun;Chung, Ki-Hwa;Kim, Jin-Hoi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.10
    • /
    • pp.1412-1421
    • /
    • 2002
  • To examine the feasibility of using a sperm vector system for gene transfer, we have investigated the binding and the uptaking of foreign DNA into the sperm nucleus by PCR, in situ hybridization and LSC. We have also examined the transportation of exogenous DNA into oocytes by immunofluorescene via PCR. Sperm cells were incubated with DNA/liposome complexes (1:4 ratio) in fertilization medium with BSA or without BSA. In situ hybridization demonstrated that the transfection rate of sperm cells with and without BSA was 41 and 68% respectively, when the cells were treated with liposome/DNA complexes and 13% for DNA alone. LSC analysis showed that the binding of exogenous DNA was greatly reduced by DNase I treatment which digests DNA bound onto spermatozoa, suggesting that some of the DNA was internalized into the sperm membrane. To find out whether transfected DNA was internalized into sperm intracytomembrane, sperm DNA was amplified by inverse PCR. No PCR products were detected from sperm cells, indicating that the foreign DNA was simply bound onto the sperm membrane. To investigate transfer rates of exogenous DNA into oocytes via sperm cells, we used immunofluorescene method to follow the distribution of foreign DNA via spermatozoa: a few exogenous DNA was located in the cytoplasm of early embryos (13/60, 21.7% for DNA+/liposome+/BSA) and was not located in the pronucleus and/or nucleus. These results suggest that most of the transfected sperm cells could carry the foreign DNA into the egg by in vitro fertilization, but that the transferred DNA is degraded in the developing embryos without stable integration into the zygote genome. Therefore, we have directly injected with transfected sperm cell into oocyte cytoplasm and observed that some of the exogenous DNA was detected in preimplantation embryonic cytoplasm and expressed at preimplantation stages, suggesting that exogenous DNA in early zygote has their integrity. In this study, we have not identified a noble mechanism that interfering transportation of foreign DNA into zygote genome via spermatozoa. Our data, however, demonstrated that inverse PCR and immunofluorescene methods would be used as a new tool for follow-up of gene distribution in oocyte via sperm cells.

A Study of $^{222}Rn\;and\;^{226}Ra$ Analysis in the Groundwater by LSC (액체섬광계수기에 의한 지하수중의 $^{222}Rn$$^{226}Ra$ 분석법 연구)

  • Woo, Hyung-Joo;Yoon, Yoon-Yeol;Cho, Soo-Young;Chun, Sang-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.275-283
    • /
    • 1995
  • PERALS(Photon Electron Rejecting Alpha Liquid Scintillation) spectrometry coupled with solvent extraction method has been set up for the analysis of $^{222}Rn\;and\;^{226}Ra$ in the groundwater. This analytical method offers low background, better energy resolution and lower quenching problem than the other techniques. By the analysis of NIST SRM 4966 $^{226}Ra$ standard, the analytical accuracy and precision were found to be 3% and 1%, respectively, and the relative standard deviation of the recovery of Rn extraction between pH2 and pH10 was 7%. Detection limits of $^{222}Rn$ and $^{226}Ra$ for 10 hours counting were counted to be $0.42 pCi/{\iota}\;and\;0.016 pCi/{\iota}$, respectively. For the test analysis of $^{222}Rn\;and\;^{226}Ra$ in the graundwater, hot spring water samples of 17 regions were analyzed. The concentration of $^{222}Rn$ were in the range of $90{\sim}5200pCi/{\iota}$ and average value was $1470pCi/{\iota}\;^{226}Ra$ concentration showed a peak value of $97.9pCi/{\iota}$ in a Kangwon region, but the average value was $1.14pCi/{\iota}$ except that region.

  • PDF

Effect Evaluation by Activity and Geometry Difference in Calibration on LSC (LSC 장비를 이용한 교정시 Activity 및 Geometry 차이에 의한 영향 평가)

  • Han, Sang-Jun;Lee, Kyung-Jin;Lee, Seung-Jin;Kim, Hee-Gang;Park, Eung-Seop
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.21-26
    • /
    • 2008
  • When the calibration on Liquid Scintillation Counter using the Solid $^3H$ Standard Source of 200,000DPM is executed, the uncertainty due to activity and geometry difference, exists. Therefore, this paper intends to evaluate environmental samples comparatively accurately as decreasing this uncertainty existing in the process of calibration. For this, measurements on samples manufactured by $^3H$ Standard Source and sensitivity study were performed. Also, this paper verified calibration results using Radioactivity-Error-Analysis Method, and evaluated quantitatively the effect by geometry and activity difference based on verification result. According to the result of sensitivity study, in case of using the exposure time of 75 sec and Repeat method, the measuring accuracy and precision of about $1{\sim}3%$ were increased in comparison with the existing method. By analysis result, the effect by activity difference did not appear, and a plastic cell existing into Teflon vial made a role as reflector. The less the effect of plastic cells are decreased, the more activity is high, and the effect of those can be neglected at the activity of 200,000 DPM.